Other resource definitions of iLO 6 v1.64
For each data type provided by the HPE ilO Redfish service, find below its description including the list of possible instances (URIs), links to related other resources, described properties and many other details.
Refer to the data types and collection section for more information on Redfish data types and collections.
AccountService
@odata.type: "#AccountService.v1_15_0.AccountService"
The AccountService resource describes the BMC user account management service. It represents the properties for this service and has links to the list of accounts.
Managing User Accounts with the Accounts Collection
JSONPath: /Accounts/@odata.id
The destination of this link is a collection of user accounts (see ManagerAccount).
-
You may create a new user account by POSTing a new account description the the Accounts collection. See ManagerAccount for details.
e.g.
POST https://{iLO}/redfish/v1/accountservice/accounts/ with new account description
-
You may modify an existing user by PATCHing properties to the user account resource. See ManagerAccount for details.
e.g.
PATCH https://{iLO}/redfish/v1/accountservice/accounts/{item} with different properties
-
You may remove a user account by DELETEing the resources representing the user
e.g.
DELETE https://{iLO}/redfish/v1/accountservice/accounts/{item}
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Accounts |
Collection of ManagerAccount |
AccountLockoutCounterResetAfter
Member of AccountService.v1_15_0.AccountService
Description | The interval of time in seconds between the last failed login attempt and reset of the lockout threshold counter. This value must be less than or equal to AccountLockoutDuration. Reset sets the counter to zero. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
AccountLockoutCounterResetEnabled
Member of AccountService.v1_15_0.AccountService
Description | The value indicates whether the threshold counter will be reset after AccountLockoutCounterResetAfter expires. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
AccountLockoutDuration
Member of AccountService.v1_15_0.AccountService
Description | The time in seconds an account is locked out. The value must be greater than or equal to the value of the AccountLockoutCounterResetAfter property. If set to 0, no lockout occurs. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
AccountLockoutThreshold
Member of AccountService.v1_15_0.AccountService
Description | The number of failed login attempts allowed before a user account is locked for a specified duration. A value of 0 means it is never locked. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Accounts
This property references a resource of type Collection with a MemberType of ManagerAccount.
Accounts is a link ("@odata.id": URI
) to another resource.
ActiveDirectory
ActiveDirectory.AccountProviderType Member of AccountService.v1_15_0.AccountService
Description | This property contains the type of external account provider this resource references. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ActiveDirectoryService |
An external Active Directory Service. |
ActiveDirectory.Authentication ActiveDirectory.Authentication.AuthenticationType Member of AccountService.v1_15_0.AccountService
Description | This property contains the type of authentication used to connect to the external account provider. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
UsernameAndPassword |
Username and password combination. |
ActiveDirectory.Authentication.Password Member of AccountService.v1_15_0.AccountService
Description | This property is used with a PATCH or PUT to write the password for the account service. This property is null on a GET. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
ActiveDirectory.Authentication.Username Member of AccountService.v1_15_0.AccountService
Description | This property contains the distinguished name for the account service. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
ActiveDirectory.RemoteRoleMapping (array) Member of AccountService.v1_15_0.AccountService
RemoteRoleMapping
is an array containing elements of:
RemoteRoleMapping[{item}].LocalRole Member of AccountService.v1_15_0.AccountService
Description | The name of the local role in which to map the remote user or group. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
RemoteRoleMapping[{item}].RemoteGroup Member of AccountService.v1_15_0.AccountService
Description | This property is the name of the remote group (or in the case of a Redfish Service, remote role) that will be mapped to the local role referenced by this entity. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
ActiveDirectory.ServiceAddresses (array) Member of AccountService.v1_15_0.AccountService
ServiceAddresses
is an array containing elements of:
ServiceAddresses[{item}] Member of AccountService.v1_15_0.AccountService
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ActiveDirectory.ServiceEnabled Member of AccountService.v1_15_0.AccountService
Description | This indicates whether this service is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
AuthFailureLoggingThreshold
Member of AccountService.v1_15_0.AccountService
Description | The number of authorization failures allowed before the failure attempt is logged to the manager log. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
HTTPBasicAuth
Member of AccountService.v1_15_0.AccountService
Description | Indicates if HTTP Basic authentication is enabled for this service. |
Type | string |
Read Only | False |
Added | iLO6 1.62 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
HTTP Basic authentication is enabled. |
Unadvertised |
HTTP Basic authentication is enabled, but is not advertised with the WWW-Authenticate response header. |
Disabled |
HTTP Basic authentication is disabled. |
LDAP
LDAP.AccountProviderType Member of AccountService.v1_15_0.AccountService
Description | This property contains the type of external account provider this resource references. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ActiveDirectoryService |
An external Active Directory Service. |
LDAPService |
A generic external LDAP Service. |
LDAP.Authentication LDAP.Authentication.AuthenticationType Member of AccountService.v1_15_0.AccountService
Description | This property contains the type of authentication used to connect to the external account provider. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
UsernameAndPassword |
Username and password combination. |
LDAP.Authentication.Password Member of AccountService.v1_15_0.AccountService
Description | This property is used with a PATCH or PUT to write the password for the account service. This property is null on a GET. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
LDAP.Authentication.Username Member of AccountService.v1_15_0.AccountService
Description | This property contains the distinguished name for the account service. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
LDAP.Certificates
A link to a collection of Certificates used for the external account service.
Certificates is a link ("@odata.id": URI
) to another resource.
LDAP.LDAPService LDAP.LDAPService.SearchSettings LDAP.LDAPService.SearchSettings.BaseDistinguishedNames (array) Member of AccountService.v1_15_0.AccountService
BaseDistinguishedNames
is an array containing elements of:
BaseDistinguishedNames[{item}] Member of AccountService.v1_15_0.AccountService
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
LDAP.RemoteRoleMapping (array) Member of AccountService.v1_15_0.AccountService
RemoteRoleMapping
is an array containing elements of:
RemoteRoleMapping[{item}].LocalRole Member of AccountService.v1_15_0.AccountService
Description | The name of the local role in which to map the remote user or group. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
RemoteRoleMapping[{item}].RemoteGroup Member of AccountService.v1_15_0.AccountService
Description | This property is the name of the remote group (or in the case of a Redfish Service, remote role) that will be mapped to the local role referenced by this entity. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
LDAP.ServiceAddresses (array) Member of AccountService.v1_15_0.AccountService
ServiceAddresses
is an array containing elements of:
ServiceAddresses[{item}] Member of AccountService.v1_15_0.AccountService
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
LDAP.ServiceEnabled Member of AccountService.v1_15_0.AccountService
Description | This indicates whether this service is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
LocalAccountAuth
Member of AccountService.v1_15_0.AccountService
Description | Controls when this service will use the accounts defined withing this AccountService as part of authentication. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Authentication via accounts defined in this AccountService is enabled. |
Disabled |
Authentication via accounts defined in this AccountService is disabled. |
MaxPasswordLength
Member of AccountService.v1_15_0.AccountService
Description | The maximum password length for this service. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
MinPasswordLength
Member of AccountService.v1_15_0.AccountService
Description | The minimum password length for this account service. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.AuthFailureDelayTimeSeconds
Member of AccountService.v1_15_0.AccountService
Description | The time in seconds to delay for each failure after AuthFailuresBeforeDelay authentication attempts have failed. Values of 2, 5, 10, and 30 seconds are valid. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
2 |
5 |
10 |
30 |
Oem.Hpe.AuthFailureLoggingThreshold
Member of AccountService.v1_15_0.AccountService
Description | This property enables you to view and configure logging criteria for failed authentications. A failed login log entry is recorded after the configured number of attempts. 0 = feature disabled; 1-3 and 5 are allowable values. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Null |
1 |
2 |
3 |
5 |
Oem.Hpe.AuthFailuresBeforeDelay
Member of AccountService.v1_15_0.AccountService
Description | The number of failed authentication attempts allowed before authentication is delayed by AuthFailureDelayTimeSeconds. Values of 0, 1, 3, and 5 are valid, with 0 indicating delay after every authentication failure. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Null |
1 |
3 |
5 |
Oem.Hpe.DefaultPassword
Member of AccountService.v1_15_0.AccountService
Description | The default password used to log in to the management processor when factory reset is performed. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DefaultUserName
Member of AccountService.v1_15_0.AccountService
Description | The default name used to log in to the management processor when factory reset is performed. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DirectorySettings
Oem.Hpe.DirectorySettings.LdapAuthenticationMode Member of AccountService.v1_15_0.AccountService
Description | Represents the LDAP authentication mode. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Disabled |
Directory authentication is disabled. |
DefaultSchema |
Directory Default schema or Schema-free option is selected. |
ExtendedSchema |
HPE Extended schema is selected. |
Oem.Hpe.DirectorySettings.LdapCaCertificateLoaded Member of AccountService.v1_15_0.AccountService
Description | Represents if the directory server CA certificate is loaded or not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DirectorySettings.LdapCaCertificates
A link to a collection of Certificates.
LdapCaCertificates is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.DirectorySettings.LdapServerPort Member of AccountService.v1_15_0.AccountService
Description | Represents the port number of the directory server. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DirectoryTest
The value of this property shall be a reference to a resource of type HpeDirectoryTest.
DirectoryTest is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.EnforcePasswordComplexity
Member of AccountService.v1_15_0.AccountService
Description | Enforce complexity rules when a user password is set or changed. Three of four character classes must be present; ASCII UPPERCASE, LOWERCASE, DIGITS, and Other |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.KerberosSettings
Oem.Hpe.KerberosSettings.KDCServerPort Member of AccountService.v1_15_0.AccountService
Description | Represents the port number of the KDC server. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.KerberosSettings.KerberosRealm Member of AccountService.v1_15_0.AccountService
Description | Represents the Realm of the KDC server. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.MinPasswordLength
Member of AccountService.v1_15_0.AccountService
Description | This property specifies the minimum number of characters allowed when a user password is set or changed. It must be a value from 0 to 39. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.TwoFactorAuth
Member of AccountService.v1_15_0.AccountService
Description | This property indicates two factor authentication enabled or not |
Type | string |
Read Only | False |
Added | iLO6 1.50 |
The following are the supported values:
Value |
---|
Enabled |
Disabled |
Roles
A link to a collection of Roles.
Roles is a link ("@odata.id": URI
) to another resource.
Actions
HpeiLOAccountService.ImportKerberosKeytab Member of AccountService.v1_15_0.AccountService Import the Kerberos keytab file.
Parameters:
ImportUri (string)
URI of the kerberos keytab file.
Assembly
@odata.type: "#Assembly.v1_5_0.Assembly"
The Assembly schema defines an assembly.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/thermalsubsystem/fans/{item}/assembly |
GET |
/redfish/v1/chassis/{item}/thermalsubsystem/pumps/{item}/assembly |
GET |
Assemblies (array)
Member of Assembly.v1_5_0.Assembly
Assemblies
is an array containing elements of:
Assemblies[{item}].@odata.id Member of Assembly.v1_5_0.Assembly
Type | string |
Read Only | True |
Added | iLO6 1.63 |
Format | uri-reference |
Assemblies[{item}].MemberId Member of Assembly.v1_5_0.Assembly
Description | The unique identifier for the member within an array. |
Type | string |
Read Only | True |
Added | iLO6 1.63 |
Assemblies[{item}].PhysicalContext Member of Assembly.v1_5_0.Assembly
Description | The area or device to which the assembly data applies. |
Type | string or null |
Read Only | True |
Added | iLO6 1.63 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Room |
The room |
Intake |
The intake point of the chassis |
Exhaust |
The exhaust point of the chassis |
Front |
The front of the chassis |
Back |
The back of the chassis |
Upper |
The upper portion of the chassis |
Lower |
The lower portion of the chassis |
CPU |
A Processor (CPU) |
GPU |
A Graphics Processor (GPU) |
Backplane |
A backplane within the chassis |
SystemBoard |
The system board (PCB) |
PowerSupply |
A power supply |
VoltageRegulator |
A voltage regulator device |
StorageDevice |
A storage device |
NetworkingDevice |
A networking device |
ComputeBay |
Within a compute bay |
StorageBay |
Within a storage bay |
NetworkBay |
Within a networking bay |
ExpansionBay |
Within an expansion bay |
PowerSupplyBay |
Within a power supply bay |
Assemblies[{item}].Status Member of Assembly.v1_5_0.Assembly See the Redfish standard schema and specification for information on common Status object.
BootOption
@odata.type: "#BootOption.v1_0_1.BootOption"
This is the schema definition for the BootOption resource. It represents the properties of a bootable device available in the System.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bootoptions/{item} |
GET |
Alias
Member of BootOption.v1_0_1.BootOption
Description | The alias of this Boot Source. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
BootOptionEnabled
Member of BootOption.v1_0_1.BootOption
Description | A flag that shows if the Boot Option is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
BootOptionReference
Member of BootOption.v1_0_1.BootOption
Description | The unique boot option string that is referenced in the BootOrder. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
DisplayName
Member of BootOption.v1_0_1.BootOption
Description | The user-readable display string of the Boot Option. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
UefiDevicePath
Member of BootOption.v1_0_1.BootOption
Description | The UEFI device path used to access this UEFI Boot Option. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
BootOptionCollection
@odata.type: "#BootOptionCollection.BootOptionCollection"
A Collection of BootOption resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/bootoptions |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
BootOption |
Members (array)
Member of BootOptionCollection.BootOptionCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of BootOptionCollection.BootOptionCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of BootOptionCollection.BootOptionCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Certificate
@odata.type: "#Certificate.v1_6_0.Certificate"
The Certificate resource describes an X509 certificate.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/externalaccountproviders/ldap/certificates/{item} |
GET PATCH DELETE |
/redfish/v1/managers/{item}/securityservice/bmchpeldevid/certificates/{item} |
GET |
/redfish/v1/managers/{item}/securityservice/bmciak/certificates/{item} |
GET |
/redfish/v1/managers/{item}/securityservice/bmcidevidpca/certificates/{item} |
GET |
/redfish/v1/managers/{item}/securityservice/bmclak/certificates/{item} |
GET |
/redfish/v1/managers/{item}/securityservice/iloidevid/certificates/{item} |
GET |
/redfish/v1/managers/{item}/securityservice/iloldevid/certificates/{item} |
GET DELETE |
/redfish/v1/managers/{item}/securityservice/platformcert/certificates/{item} |
GET |
/redfish/v1/managers/{item}/securityservice/systemiak/certificates/{item} |
GET |
/redfish/v1/managers/{item}/securityservice/systemidevid/certificates/{item} |
GET |
/redfish/v1/managers/{item}/securityservice/systemlak/certificates/{item} |
GET |
/redfish/v1/managers/{item}/securityservice/systemldevid/certificates/{item} |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/db/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbdefault/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbr/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbrdefault/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbt/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbtdefault/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbx/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbxdefault/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kek/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kekdefault/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/pk/certificates/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/pkdefault/certificates/{item} |
GET DELETE |
CertificateString
Member of Certificate.v1_6_0.Certificate
Description | Contains PEM formatted X509 certificate or PKCS7 certificate chain (Base64 encoded). |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | text |
CertificateType
Member of Certificate.v1_6_0.Certificate
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
PEM |
A PEM encoded certificate. |
PKCS7 |
A PEM encoded PKCS7 certificate. |
Issuer
Issuer.City Member of Certificate.v1_6_0.Certificate
Description | The city or locality of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Issuer.CommonName Member of Certificate.v1_6_0.Certificate
Description | The fully qualified domain name of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Issuer.Country Member of Certificate.v1_6_0.Certificate
Description | The country of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Issuer.DisplayString Member of Certificate.v1_6_0.Certificate
Description | A human-readable string for this identifier. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Issuer.Email Member of Certificate.v1_6_0.Certificate
Description | The email address of the contact within the organization of the entity. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Issuer.Organization Member of Certificate.v1_6_0.Certificate
Description | The name of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Issuer.OrganizationalUnit Member of Certificate.v1_6_0.Certificate
Description | The name of the unit or division of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Issuer.State Member of Certificate.v1_6_0.Certificate
Description | The state, province, or region of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
SerialNumber
Member of Certificate.v1_6_0.Certificate
Description | The serial number that the Certificate Authority assigned to the certificate. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Subject
Subject.City Member of Certificate.v1_6_0.Certificate
Description | The city or locality of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Subject.CommonName Member of Certificate.v1_6_0.Certificate
Description | The fully qualified domain name of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Subject.Country Member of Certificate.v1_6_0.Certificate
Description | The country of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Subject.DisplayString Member of Certificate.v1_6_0.Certificate
Description | A human-readable string for this identifier. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Subject.Email Member of Certificate.v1_6_0.Certificate
Description | The email address of the contact within the organization of the entity. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Subject.Organization Member of Certificate.v1_6_0.Certificate
Description | The name of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Subject.OrganizationalUnit Member of Certificate.v1_6_0.Certificate
Description | The name of the unit or division of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Subject.State Member of Certificate.v1_6_0.Certificate
Description | The state, province, or region of the organization of the entity. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
UefiSignatureOwner
Member of Certificate.v1_6_0.Certificate
Description | The UEFI signature owner for this certificate. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ValidNotAfter
Member of Certificate.v1_6_0.Certificate
Description | The date on which the certificate validity period ends. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
ValidNotBefore
Member of Certificate.v1_6_0.Certificate
Description | The date on which the certificate validity period begins. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
CertificateCollection
@odata.type: "#CertificateCollection.CertificateCollection"
A Collection of Certificate resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/externalaccountproviders/ldap/certificates |
GET POST |
/redfish/v1/managers/{item}/securityservice/bmchpeldevid/certificates |
GET |
/redfish/v1/managers/{item}/securityservice/bmciak/certificates |
GET |
/redfish/v1/managers/{item}/securityservice/bmcidevidpca/certificates |
GET |
/redfish/v1/managers/{item}/securityservice/bmclak/certificates |
GET |
/redfish/v1/managers/{item}/securityservice/iloidevid/certificates |
GET |
/redfish/v1/managers/{item}/securityservice/iloldevid/certificates |
GET POST |
/redfish/v1/managers/{item}/securityservice/platformcert/certificates |
GET |
/redfish/v1/managers/{item}/securityservice/systemiak/certificates |
GET |
/redfish/v1/managers/{item}/securityservice/systemidevid/certificates |
GET |
/redfish/v1/managers/{item}/securityservice/systemlak/certificates |
GET |
/redfish/v1/managers/{item}/securityservice/systemldevid/certificates |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/db/certificates |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbdefault/certificates |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbr/certificates |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbrdefault/certificates |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbt/certificates |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbtdefault/certificates |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbx/certificates |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbxdefault/certificates |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kek/certificates |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kekdefault/certificates |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/pk/certificates |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/pkdefault/certificates |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Certificate |
Members (array)
Member of CertificateCollection.CertificateCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of CertificateCollection.CertificateCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of CertificateCollection.CertificateCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CertificateLocations
@odata.type: "#CertificateLocations.v1_0_2.CertificateLocations"
The CertificateLocations schema describes a Resource that an administrator can use in order to locate all certificates installed on a given service.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/certificateservice/certificatelocations |
GET |
CertificateService
@odata.type: "#CertificateService.v1_0_3.CertificateService"
The CertificateService schema describes a certificate service that represents the actions available to manage certificates and links to the certificates.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/certificateservice |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Links/CertificateLocations |
CertificateLocations |
CertificateLocations
The information about the location of certificates.
CertificateLocations is a link ("@odata.id": URI
) to another resource.
Actions
CertificateService.GenerateCSR Member of CertificateService.v1_0_3.CertificateService
Parameters:
City (string)
The city or locality of the organization making the request.
GivenName (string)
The given name of the user making the request.
KeyPairAlgorithm (string)
The type of key-pair for use with signing algorithms.
CertificateCollection (object)
The link to the certificate collection where the certificate is installed after the certificate authority (CA) signs the certificate.
Country (string)
The two-letter country code of the organization making the request.
KeyCurveId (string)
The curve ID to use with the key, if needed based on the KeyPairAlgorithm parameter value.
CommonName (string)
The fully qualified domain name of the component to secure.
State (string)
The state, province, or region of the organization making the request.
ContactPerson (string)
The name of the user making the request.
Email (string)
The email address of the contact within the organization making the request.
Surname (string)
The surname of the user making the request.
KeyUsage (array)
The usage of the key contained in the certificate.
UnstructuredName (string)
The unstructured name of the subject.
KeyBitLength (integer)
The length of the key, in bits, if needed based on the KeyPairAlgorithm parameter value.
Organization (string)
The name of the organization making the request.
AlternativeNames (array)
The additional host names of the component to secure.
ChallengePassword (string)
The challenge password to apply to the certificate for revocation requests.
OrganizationalUnit (string)
The name of the unit or division of the organization making the request.
Initials (string)
The initials of the user making the request.
ComponentIntegrity
@odata.type: "#ComponentIntegrity.v1_2_3.ComponentIntegrity"
The ComponentIntegrity resource provides critical and pertinent security information about a specific device, system, software element, or other managed entity.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/ComponentIntegrity/{item} |
GET POST |
ComponentIntegrityEnabled
Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Description | An indication of whether security protocols are enabled for the component. |
Type | boolean |
Read Only | False |
Added | iLO6 1.10 |
ComponentIntegrityType
Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Type | string |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
SPDM |
Security Protocol and Data Model (SPDM) protocol. |
TPM |
Trusted Platform Module (TPM). |
OEM |
OEM-specific. |
ComponentIntegrityTypeVersion
Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Description | The version of the security technology. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Oem.Hpe.ExtendedVerificationStatus
Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Description | Extended Verification Status of the Host Processor Module. |
Type | string or null |
Read Only | True |
Added | iLO6 1.61 |
The following are the supported values:
Value | Description |
---|---|
NotValidated |
Host Processor Moduleis not validated yet, HPM is in factory Mode/HPM auth key slot not yet populated |
Success |
Host Processor Module authentication successful. |
Failed |
Host Processor Module authentication Failed. |
Error |
Host Processor Module authentication internal error occured. Please retry. |
CertificateCheckFailed |
Host Processor Module authentication Certificate check failed. |
SPDM
SPDM.IdentityAuthentication SPDM.IdentityAuthentication.ResponderAuthentication SPDM.IdentityAuthentication.ResponderAuthentication.VerificationStatus Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Description | The status of the verification of the identity of the component. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
Success |
Successful verification. |
Failed |
Unsuccessful verification. |
SPDM.MeasurementSet SPDM.MeasurementSet.MeasurementSpecification Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Type | string |
Read Only | True |
Added | iLO6 1.45 |
The following are the supported values:
Value | Description |
---|---|
DMTF |
DMTF. |
SPDM.MeasurementSet.Measurements (array) Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Measurements
is an array containing elements of:
Measurements[{item}].LastUpdated Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Description | The date and time when information for the measurement was last updated. |
Type | string or null |
Read Only | True |
Added | iLO6 1.40 |
Format | date-time |
Measurements[{item}].Measurement Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Description | The measurement data. |
Type | string or null |
Read Only | True |
Added | iLO6 1.40 |
Measurements[{item}].MeasurementHashAlgorithm Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Description | The hash algorithm used to compute the measurement. |
Type | string or null |
Read Only | True |
Added | iLO6 1.40 |
Measurements[{item}].MeasurementIndex Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Description | The index of the measurement. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.45 |
Measurements[{item}].MeasurementType Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Type | string or null |
Read Only | True |
Added | iLO6 1.45 |
The following are the supported values:
Value | Description |
---|---|
ImmutableROM |
Immutable ROM. |
MutableFirmware |
Mutable firmware or any mutable code. |
HardwareConfiguration |
Hardware configuration, such as straps. |
FirmwareConfiguration |
Firmware configuration, such as configurable firmware policy. |
MutableFirmwareVersion |
Mutable firmware version. |
MutableFirmwareSecurityVersionNumber |
Mutable firmware security version number. |
MeasurementManifest |
Measurement Manifest. |
Measurements[{item}].SecurityVersionNumber Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Description | The security version number the measurement represents. |
Type | string or null |
Read Only | True |
Added | iLO6 1.45 |
SPDM.Requester
The link to the the component that is reporting the integrity information of the target component.
Requester is a link ("@odata.id": URI
) to another resource.
Status
Member of ComponentIntegrity.v1_2_3.ComponentIntegrity See the Redfish standard schema and specification for information on common Status object.
TPM
TPM.ComponentCommunication TPM.ComponentCommunication.Sessions (array) Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Sessions
is an array containing elements of:
Sessions[{item}].SessionId Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Description | The identifier for an active session or communication channel between two components. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.40 |
Sessions[{item}].SessionType Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Type | string |
Read Only | True |
Added | iLO6 1.40 |
The following are the supported values:
Value | Description |
---|---|
Plain |
A plain text session without any protection. |
EncryptedAuthenticated |
An established session where both encryption and authentication are protecting the communication. |
AuthenticatedOnly |
An established session where only authentication is protecting the communication. |
TPM.MeasurementSet TPM.MeasurementSet.Measurements (array) Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Measurements
is an array containing elements of:
Measurements[{item}].LastUpdated Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Description | The date and time when information for the measurement was last updated. |
Type | string or null |
Read Only | True |
Added | iLO6 1.40 |
Format | date-time |
Measurements[{item}].Measurement Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Description | The measurement data. |
Type | string or null |
Read Only | True |
Added | iLO6 1.40 |
Measurements[{item}].MeasurementHashAlgorithm Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Description | The hash algorithm used to compute the measurement. |
Type | string or null |
Read Only | True |
Added | iLO6 1.40 |
Measurements[{item}].PCR Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Description | The Platform Configuration Register (PCR) bank of the measurement. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.40 |
TPM.NonceSizeBytesMaximum Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Description | The maximum number of bytes that can be specified in the Nonce parameter of the TPMGetSignedMeasurements action. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.40 |
TargetComponentURI
Member of ComponentIntegrity.v1_2_3.ComponentIntegrity
Description | The link to the the component whose integrity that this resource reports. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Actions
ComponentIntegrity.TPMGetSignedMeasurements Member of ComponentIntegrity.v1_2_3.ComponentIntegrity This action gets the TPM Signed Measurements.
Parameters:
Nonce (string)
A set of bytes as a hex-encoded string that is signed with the measurements. The value should be unique.
title (string)
Friendly action name
target (string)
Link to invoke action
PCRSelection (string)
An object that identify the PCRs to sign.
ComponentIntegrity.SPDMGetSignedMeasurements Member of ComponentIntegrity.v1_2_3.ComponentIntegrity This action gets the SPDM Signed Measurements.
Parameters:
Nonce (string)
A set of bytes as a hex-encoded string that is signed with the measurements. The value should be unique.
target (string)
Link to invoke action
title (string)
Friendly action name
SlotId (integer)
The slot identifier for the certificate containing the private key to generate the signature over the measurements.
MeasurementIndices (array)
An array of indices that identify the measurement blocks to sign.
ComponentIntegrityCollection
@odata.type: "#ComponentIntegrityCollection.ComponentIntegrityCollection"
A Collection of ComponentIntegrity resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/ComponentIntegrity |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
ComponentIntegrity |
Members (array)
Member of ComponentIntegrityCollection.ComponentIntegrityCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of ComponentIntegrityCollection.ComponentIntegrityCollection
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Format | uri-reference |
Members@odata.count
Member of ComponentIntegrityCollection.ComponentIntegrityCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.10 |
EnvironmentMetrics
@odata.type: "#EnvironmentMetrics.v1_3_2.EnvironmentMetrics"
The EnvironmentMetrics schema represents the environmental metrics of a device.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/environmentmetrics |
GET |
/redfish/v1/systems/{item}/processors/{item}/environmentmetrics |
GET |
EnergyJoules
EnergyJoules.DataSourceUri Member of EnvironmentMetrics.v1_3_2.EnvironmentMetrics
Description | The link to the resource that provides the data for this sensor. |
Type | string or null |
Read Only | True |
Added | iLO6 1.61 |
EnergyJoules.Reading Member of EnvironmentMetrics.v1_3_2.EnvironmentMetrics
Description | The sensor value |
Type | number or null |
Read Only | True |
Added | iLO6 1.61 |
EventDestination
@odata.type: "#EventDestination.v1_13_0.EventDestination"
The EventDestination resource describes the target of an event subscription, including the types of events subscribed and context to provide to the target in the Event payload.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/eventservice/subscriptions/{item} |
GET PATCH DELETE |
Context
Member of EventDestination.v1_13_0.EventDestination
Description | A client-supplied string that is stored with the listener destination subscription. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Destination
Member of EventDestination.v1_13_0.EventDestination
Description | The URI of the destination listener service. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Format | uri-reference |
EventFormatType
Member of EventDestination.v1_13_0.EventDestination
Description | The content types of the message that are sent to the EventDestination. |
Type | string or null |
Read Only | False |
Added | iLO6 1.51 |
The following are the supported values:
Value |
---|
Event |
MetricReport |
HttpHeaders (array)
Member of EventDestination.v1_13_0.EventDestination
HttpHeaders
is an array containing elements of:
HttpHeaders[{item}]
MetricReportDefinitions (array)
Member of EventDestination.v1_13_0.EventDestination
MetricReportDefinitions
is an array containing elements of:
MetricReportDefinitions[{item}].@odata.id Member of EventDestination.v1_13_0.EventDestination
Type | string |
Read Only | True |
Added | iLO6 1.51 |
Format | uri-reference |
Oem.Hpe.DeliveryRetryAttempts
Member of EventDestination.v1_13_0.EventDestination
Description | This is the number of attempts an event posting is retried before the subscription is terminated. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.DeliveryRetryIntervalInSeconds
Member of EventDestination.v1_13_0.EventDestination
Description | This represents the number of seconds between retry attempts for sending any given Event |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.MutualAuthenticationEnabled
Member of EventDestination.v1_13_0.EventDestination
Description | This represents if the subscriber and iLO need to perform mutual authentication when an event is sent. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.RequestedMaxEventsToQueue
Member of EventDestination.v1_13_0.EventDestination
Description | This represents the number of events the service should queue. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.RetireOldEventInMinutes
Member of EventDestination.v1_13_0.EventDestination
Description | This represents the number of minutes until an event is expired. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Protocol
Member of EventDestination.v1_13_0.EventDestination
Description | The protocol type of the event connection. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Redfish |
RegistryPrefixes (array)
Member of EventDestination.v1_13_0.EventDestination
RegistryPrefixes
is an array containing elements of:
RegistryPrefixes[{item}] Member of EventDestination.v1_13_0.EventDestination
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SubscriptionType
Member of EventDestination.v1_13_0.EventDestination
Description | The subscription type for events. |
Type | string or null |
Read Only | True |
Added | iLO6 1.20 |
The following are the supported values:
Value |
---|
RedfishEvent |
EventDestinationCollection
@odata.type: "#EventDestinationCollection.EventDestinationCollection"
A Collection of EventDestination resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/eventservice/subscriptions |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
EventDestination |
Members (array)
Member of EventDestinationCollection.EventDestinationCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of EventDestinationCollection.EventDestinationCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of EventDestinationCollection.EventDestinationCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
EventService
@odata.type: "#EventService.v1_7_2.EventService"
The EventService resource describes the Event Service. It represents the properties for the service itself and has links to the actual list of subscriptions.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/eventservice |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Subscriptions |
Collection of EventDestination |
Oem/Hpe/CACertificates |
Collection of HpeCertificate |
DeliveryRetryAttempts
Member of EventService.v1_7_2.EventService
Description | This is the number of attempts an event posting is retried before the subscription is terminated. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
DeliveryRetryIntervalSeconds
Member of EventService.v1_7_2.EventService
Description | This represents the number of seconds between retry attempts for sending any given Event |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
EventTypesForSubscription (array)
Member of EventService.v1_7_2.EventService
EventTypesForSubscription
is an array containing elements of:
EventTypesForSubscription[{item}] Member of EventService.v1_7_2.EventService
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
StatusChange |
The status of this resource has changed |
ResourceUpdated |
The value of this resource has been updated |
ResourceAdded |
A resource has been added |
ResourceRemoved |
A resource has been removed |
Alert |
A condition exists which requires attention |
Oem.Hpe.CACertificates
The value of this property shall be a reference to a Collection of HpeCertificate resources.
CACertificates is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.RequestedMaxEventsToQueueDefault
Member of EventService.v1_7_2.EventService
Description | This represents the default number of events the service should queue. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.RetireOldEventInMinutesDefault
Member of EventService.v1_7_2.EventService
Description | This represents the default number of minutes until an event is expired. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.TTLCountDefault
Member of EventService.v1_7_2.EventService
Description | The default number of TTLUnits until this listener destination subscription expires. It may be renewed prior to expire to reset the Time to Live counter. The value 999999 is reserved to mean a perpetual subscription. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.TTLUnitsDefault
Member of EventService.v1_7_2.EventService
Description | The default time unit used to measure the subscription time of this listener destination. This is the units for TTLCount and is used to express the subscription lifetime of the listener destination. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
seconds |
Time to Live (TTL) in Seconds |
minutes |
Time to Live (TTL) in Minutes |
days |
Time to Live (TTL) in Days |
RegistryPrefixes (array)
Member of EventService.v1_7_2.EventService
RegistryPrefixes
is an array containing elements of:
RegistryPrefixes[{item}] Member of EventService.v1_7_2.EventService
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ServiceEnabled
Member of EventService.v1_7_2.EventService
Description | This indicates whether this service is enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of EventService.v1_7_2.EventService See the Redfish standard schema and specification for information on common Status object.
Subscriptions
This is a reference to a collection of ListenerDestination resources.
Subscriptions is a link ("@odata.id": URI
) to another resource.
Actions
EventService.SubmitTestEvent Member of EventService.v1_7_2.EventService
Parameters:
EventId (string)
Severity (string)
Value | Description |
---|---|
OK | |
Warning | |
Critical |
EventType (string)
Value | Description |
---|---|
StatusChange | |
ResourceUpdated | |
ResourceAdded | |
ResourceRemoved | |
Alert |
OriginOfCondition (string)
EventTimestamp (string)
MessageId (string)
Message (string)
MessageArgs (array)
HpeEventService.ClearAllSubscriptions Member of EventService.v1_7_2.EventService There are no parameters for this action.
HpeEventService.ImportCACertificate Member of EventService.v1_7_2.EventService Imports a Trusted CA Certificate
Parameters:
Certificate (string)
Contains PEM formatted X509 certificate or PKCS7 certificate chain (Base64 encoded).
Fabric
@odata.type: "#Fabric.v1_3_0.Fabric"
The Fabric schema represents a simple fabric consisting of one or more switches,
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/fabrics/{item} |
GET POST PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Collection of SwitchCollection |
FabricType
Member of Fabric.v1_3_0.Fabric
Type | string or null |
Read Only | True |
Added | iLO6 1.54 |
The following are the supported values:
Value | Description |
---|---|
PCIe |
PCI Express. |
AHCI |
Advanced Host Controller Interface (AHCI). |
UHCI |
Universal Host Controller Interface (UHCI). |
SAS |
Serial Attached SCSI. |
SATA |
Serial AT Attachment. |
USB |
Universal Serial Bus (USB). |
NVMe |
Non-Volatile Memory Express (NVMe). |
FC |
Fibre Channel. |
iSCSI |
Internet SCSI. |
FCoE |
Fibre Channel over Ethernet (FCoE). |
FCP |
Fibre Channel Protocol for SCSI. |
FICON |
FIbre CONnection (FICON). |
NVMeOverFabrics |
NVMe over Fabrics. |
SMB |
Server Message Block (SMB). Also known as the Common Internet File System (CIFS). |
NFSv3 |
Network File System (NFS) version 3. |
NFSv4 |
Network File System (NFS) version 4. |
HTTP |
Hypertext Transport Protocol (HTTP). |
HTTPS |
Hypertext Transfer Protocol Secure (HTTPS). |
FTP |
File Transfer Protocol (FTP). |
SFTP |
SSH File Transfer Protocol (SFTP). |
iWARP |
Internet Wide Area RDMA Protocol (iWARP). |
RoCE |
RDMA over Converged Ethernet Protocol. |
RoCEv2 |
RDMA over Converged Ethernet Protocol Version 2. |
I2C |
Inter-Integrated Circuit Bus. |
TCP |
Transmission Control Protocol (TCP). |
UDP |
User Datagram Protocol (UDP). |
TFTP |
Trivial File Transfer Protocol (TFTP). |
GenZ |
GenZ. |
MultiProtocol |
Multiple Protocols. |
InfiniBand |
InfiniBand. |
Ethernet |
Ethernet. |
NVLink |
NVLink. |
OEM |
OEM-specific. |
DisplayPort |
DisplayPort. |
HDMI |
HDMI. |
VGA |
VGA. |
DVI |
DVI. |
CXL |
Compute Express Link. |
Switches
The collection of links to the switches that this fabric contains.
Switches is a link ("@odata.id": URI
) to another resource.
FabricCollection
@odata.type: "#FabricCollection.FabricCollection"
A Collection of Fabric Resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/fabrics |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Fabric |
Members (array)
Member of FabricCollection.FabricCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of FabricCollection.FabricCollection
Type | string |
Read Only | True |
Added | iLO6 1.54 |
Format | uri-reference |
Members@odata.count
Member of FabricCollection.FabricCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.54 |
Fan
@odata.type: "#Fan.v1_5_1.Fan"
The Fan schema describes a cooling fan unit for a computer system or similar devices contained within a chassis. It also describes the location, such as a slot, socket, or bay, where a unit can be installed, by populating a resource instance with an absent state if a unit is not present.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/thermalsubsystem/fans/{item} |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Assembly |
Assembly |
Assembly
The link to the summary of assembly for this subsystem.
Assembly is a link ("@odata.id": URI
) to another resource.
HotPluggable
Member of Fan.v1_5_1.Fan
Description | An indication of whether this device can be inserted or removed while the equipment is in operation. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.63 |
PhysicalContext
Member of Fan.v1_5_1.Fan
Description | The area or device associated with this fan. |
Type | string or null |
Read Only | True |
Added | iLO6 1.63 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Room |
The room |
Intake |
The intake point of the chassis |
Exhaust |
The exhaust point of the chassis |
Front |
The front of the chassis |
Back |
The back of the chassis |
Upper |
The upper portion of the chassis |
Lower |
The lower portion of the chassis |
CPU |
A Processor (CPU) |
GPU |
A Graphics Processor (GPU) |
Backplane |
A backplane within the chassis |
SystemBoard |
The system board (PCB) |
PowerSupply |
A power supply |
VoltageRegulator |
A voltage regulator device |
StorageDevice |
A storage device |
NetworkingDevice |
A networking device |
ComputeBay |
Within a compute bay |
StorageBay |
Within a storage bay |
NetworkBay |
Within a networking bay |
ExpansionBay |
Within an expansion bay |
PowerSupplyBay |
Within a power supply bay |
SpeedPercent
SpeedPercent.DataSourceUri Member of Fan.v1_5_1.Fan
Description | The link to the resource that provides the data for this sensor. |
Type | string or null |
Read Only | True |
Added | iLO6 1.63 |
SpeedPercent.Reading Member of Fan.v1_5_1.Fan
Description | The sensor value |
Type | number or null |
Read Only | True |
Added | iLO6 1.63 |
SpeedPercent.SpeedRPM Member of Fan.v1_5_1.Fan
Description | The rotational speed. |
Type | number or null |
Read Only | True |
Added | iLO6 1.63 |
Status
Member of Fan.v1_5_1.Fan See the Redfish standard schema and specification for information on common Status object.
FanCollection
@odata.type: "#FanCollection.FanCollection"
The Collection of Fan resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/thermalsubsystem/fans |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Fan |
Members (array)
Member of FanCollection.FanCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of FanCollection.FanCollection
Type | string |
Read Only | True |
Added | iLO6 1.63 |
Format | uri-reference |
Members@odata.count
Member of FanCollection.FanCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.63 |
HostInterface
@odata.type: "#HostInterface.v1_1_1.HostInterface"
The HostInterface resource describes a Redfish Host Interface, which is a method of accessing the Redfish API from the host computer system.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/hostinterfaces/{item} |
GET PATCH |
AuthenticationModes (array)
Member of HostInterface.v1_1_1.HostInterface
AuthenticationModes
is an array containing elements of:
AuthenticationModes[{item}].AuthenticationMode Member of HostInterface.v1_1_1.HostInterface
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
AuthNone |
Requests without any sort of authentication are allowed. |
BasicAuth |
Requests using HTTP Basic Authentication are allowed. |
RedfishSessionAuth |
Requests using Redfish Session Authentication are allowed. |
OemAuth |
Requests using OEM authentication mechanisms are allowed. |
ExternallyAccessible
Member of HostInterface.v1_1_1.HostInterface
Description | This indicates whether this interface is accessible by external entities. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
FirmwareAuthEnabled
Member of HostInterface.v1_1_1.HostInterface
Description | This indicates whether this firmware authentication is enabled for this interface. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
FirmwareAuthRoleId
Member of HostInterface.v1_1_1.HostInterface
Description | This property contains the Role for firmware authentication on this interface. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
HostEthernetInterfaces
This is a reference to a collection of NICs that Computer Systems use for network communication with this Host Interface.
HostEthernetInterfaces is a link ("@odata.id": URI
) to another resource.
HostEthernetInterfaces
property is not supported in iLO5.
HostInterfaceType
Member of HostInterface.v1_1_1.HostInterface
Description | This indicates the Host Interface type for this interface. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NetworkHostInterface |
This interface is a Network Host Interface. |
InterfaceEnabled
Member of HostInterface.v1_1_1.HostInterface
Description | This indicates whether this interface is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
KernelAuthEnabled
Member of HostInterface.v1_1_1.HostInterface
Description | This indicates whether this kernel authentication is enabled for this interface. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
KernelAuthRoleId
Member of HostInterface.v1_1_1.HostInterface
Description | This property contains the Role for kernel authentication on this interface. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
ManagerEthernetInterface
This is a reference to a single NIC that this Manager uses for network communication with this Host Interface.
ManagerEthernetInterface is a link ("@odata.id": URI
) to another resource.
NetworkProtocol
This is a reference to the network services and their settings that the Manager controls. It is here that clients will find network configuration options as well as network services.
NetworkProtocol is a link ("@odata.id": URI
) to another resource.
Status
Member of HostInterface.v1_1_1.HostInterface See the Redfish standard schema and specification for information on common Status object.
HostInterfaceCollection
@odata.type: "#HostInterfaceCollection.HostInterfaceCollection"
A Collection of HostInterface resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/hostinterfaces |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
HostInterface |
Members (array)
Member of HostInterfaceCollection.HostInterfaceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of HostInterfaceCollection.HostInterfaceCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of HostInterfaceCollection.HostInterfaceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
JsonSchemaFile
@odata.type: "#JsonSchemaFile.v1_0_4.JsonSchemaFile"
The JSON Schema File resource describes the location (URI) of a particular Redfish schema definition being implemented or referenced by a Redfish service.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/jsonschemas/{item} |
GET |
Languages (array)
Member of JsonSchemaFile.v1_0_4.JsonSchemaFile
Languages
is an array containing elements of:
Languages[{item}] Member of JsonSchemaFile.v1_0_4.JsonSchemaFile
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Location (array)
Member of JsonSchemaFile.v1_0_4.JsonSchemaFile
Location
is an array containing elements of:
Location[{item}].Language Member of JsonSchemaFile.v1_0_4.JsonSchemaFile
Description | The RFC 5646 language code for this schema or registry item. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Location[{item}].Uri Member of JsonSchemaFile.v1_0_4.JsonSchemaFile
Description | Link to locally available URI for schema. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Schema
Member of JsonSchemaFile.v1_0_4.JsonSchemaFile
Description | The typename this schema describes. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
JsonSchemaFileCollection
@odata.type: "#JsonSchemaFileCollection.JsonSchemaFileCollection"
A Collection of JsonSchemaFile resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/jsonschemas |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
JsonSchemaFile |
Members (array)
Member of JsonSchemaFileCollection.JsonSchemaFileCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of JsonSchemaFileCollection.JsonSchemaFileCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of JsonSchemaFileCollection.JsonSchemaFileCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Key
@odata.type: "#Key.v1_4_1.Key"
The Key
schema describes sensitive data for accessing devices or services.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/accounts/{item}/keys/{item} |
GET PATCH DELETE |
KeyString
Member of Key.v1_4_1.Key
Description | The string for the key. |
Type | string or null |
Read Only | False |
Added | iLO6 1.63 |
KeyType
Member of Key.v1_4_1.Key
Type | string |
Read Only | False |
Added | iLO6 1.63 |
The following are the supported values:
Value | Description |
---|---|
NVMeoF |
An NVMe-oF key. |
SSH |
An SSH public key. |
SSH
SSH.Comment Member of Key.v1_4_1.Key
Description | The user-specified comment associated with this key, which typically contains the client's username and host name. |
Type | string or null |
Read Only | True |
Added | iLO6 1.63 |
SSH.Fingerprint Member of Key.v1_4_1.Key
Description | A fingerprint of the key. |
Type | string or null |
Read Only | True |
Added | iLO6 1.63 |
KeyCollection
@odata.type: "#KeyCollection.KeyCollection"
The collection of Key
resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/accounts/{item}/keys |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Key |
Members (array)
Member of KeyCollection.KeyCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of KeyCollection.KeyCollection
Type | string |
Read Only | True |
Added | iLO6 1.63 |
Format | uri-reference |
Members@odata.count
Member of KeyCollection.KeyCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.63 |
LogEntry
@odata.type: "#LogEntry.v1_11_0.LogEntry"
This resource defines the record format for a log. It is designed to be used for SEL logs (from IPMI) as well as Event Logs and OEM-specific log formats. The EntryType field indicates the type of log and the resource includes several additional properties dependent on the EntryType.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/logservices/iel/entries/{item} |
GET |
/redfish/v1/managers/{item}/remotesupportservice/serviceeventlogs/{item} |
GET |
/redfish/v1/systems/{item}/logservices/dpu/entries/{item} |
GET PATCH |
/redfish/v1/systems/{item}/logservices/event/entries/{item} |
GET |
/redfish/v1/systems/{item}/logservices/iml/entries/{item} |
GET PATCH |
/redfish/v1/systems/{item}/logservices/sl/entries/{item} |
GET |
Created
Member of LogEntry.v1_11_0.LogEntry
Description | The date and time when the log entry was created, for example, 2014-04-15T00:38:00Z. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
EntryType
Member of LogEntry.v1_11_0.LogEntry
Description | The log entry type. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Oem |
EventId
Member of LogEntry.v1_11_0.LogEntry
Description | The unique instance identifier for an event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
EventTimestamp
Member of LogEntry.v1_11_0.LogEntry
Description | The date and time when the event occurred. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Message
Member of LogEntry.v1_11_0.LogEntry
Description | The log entry details. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
MessageArgs (array)
Member of LogEntry.v1_11_0.LogEntry
MessageArgs
is an array containing elements of:
MessageArgs[{item}] Member of LogEntry.v1_11_0.LogEntry
Type | string |
Read Only | True |
Added | iLO6 1.05 |
MessageId
Member of LogEntry.v1_11_0.LogEntry
Description | The MessageId, event data, or OEM-specific information. This property decodes from the entry type. If the entry type is Event , this property contains a Redfish Specification-defined MessageId. If the entry type is SEL , this property contains the Event Data. Otherwise, this property contains OEM-specific information. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Categories (array)
Member of LogEntry.v1_11_0.LogEntry
Categories
is an array containing elements of:
Categories[{item}] Member of LogEntry.v1_11_0.LogEntry
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Security |
Hardware |
Firmware |
Maintenance |
Administration |
Power |
Cooling |
Invalid User Input |
Other |
Configuration |
Oem.Hpe.Class
Member of LogEntry.v1_11_0.LogEntry
Description | The log entry event class. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ClassDescription
Member of LogEntry.v1_11_0.LogEntry
Description | The log entry event class description. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Code
Member of LogEntry.v1_11_0.LogEntry
Description | The log entry event code. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Count
Member of LogEntry.v1_11_0.LogEntry
Description | The occurrence count of the log entry. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Destination
Member of LogEntry.v1_11_0.LogEntry
Description | The destination host name or IP address of the remote server that recevied the service event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EventNumber
Member of LogEntry.v1_11_0.LogEntry
Description | The event log identification number. Events are numbered in the order in which they are generated. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Identifier
Member of LogEntry.v1_11_0.LogEntry
Description | The unique identifier of the service event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LearnMoreLink
Member of LogEntry.v1_11_0.LogEntry
Description | The link to troubleshooting information. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Oem.Hpe.RecommendedAction
Member of LogEntry.v1_11_0.LogEntry
Description | The recommended action for the event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Repaired
Member of LogEntry.v1_11_0.LogEntry
Description | The repaired status of the IML event. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.ServiceEvent
Member of LogEntry.v1_11_0.LogEntry
Description | This indicates a service ticket to be raised for the corresponding event log. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ServiceEventMessageID
Member of LogEntry.v1_11_0.LogEntry
Description | This property represents the Embedded Remote Support Message ID. It is applicable only for a Service Event log. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Severity
Member of LogEntry.v1_11_0.LogEntry
Description | The log entry event Severity. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Informational |
Informational event |
Caution |
Caution event |
Critical |
Critical event |
Repaired |
Critical or Caution event repaired |
Oem.Hpe.SubmitStatus
Member of LogEntry.v1_11_0.LogEntry
Description | The service event log submission status . |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Updated
Member of LogEntry.v1_11_0.LogEntry
Description | The date and time of the latest log entry update, for example, 2014-04-15T00:38:00Z. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Oem.Hpe.UserAction
Member of LogEntry.v1_11_0.LogEntry
Description | The User action for the event. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Repaired |
The event repaired by user. |
Ignored |
The event ignored by user. |
None |
No user action taken on the event. |
Not Applicable |
User action not applicable for the event. |
OemRecordFormat
Member of LogEntry.v1_11_0.LogEntry
Description | The format of an OEM record. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Hpe-IML |
Hpe-iLOEventLog |
Hpe-SL |
Hpe-Event |
Severity
Member of LogEntry.v1_11_0.LogEntry
Description | The log entry severity. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
OK |
Warning |
Critical |
LogEntryCollection
@odata.type: "#LogEntryCollection.LogEntryCollection"
A Collection of LogEntry resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/logservices/iel/entries |
GET POST |
/redfish/v1/managers/{item}/remotesupportservice/serviceeventlogs |
GET |
/redfish/v1/systems/{item}/logservices/dpu/entries |
GET POST |
/redfish/v1/systems/{item}/logservices/event/entries |
GET POST |
/redfish/v1/systems/{item}/logservices/iml/entries |
GET POST |
/redfish/v1/systems/{item}/logservices/sl/entries |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
LogEntry |
Members (array)
Member of LogEntryCollection.LogEntryCollection
Members
is an array containing elements of:
Members[{item}].@odata.context Member of LogEntryCollection.LogEntryCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members[{item}].@odata.etag Member of LogEntryCollection.LogEntryCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].@odata.id Member of LogEntryCollection.LogEntryCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members[{item}].@odata.type Member of LogEntryCollection.LogEntryCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Created Member of LogEntryCollection.LogEntryCollection
Description | The date and time when the log entry was created, for example, 2014-04-15T00:38:00Z. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Members[{item}].EntryType Member of LogEntryCollection.LogEntryCollection
Description | The log entry type. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Oem |
Members[{item}].EventId Member of LogEntryCollection.LogEntryCollection
Description | The unique instance identifier for an event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].EventTimestamp Member of LogEntryCollection.LogEntryCollection
Description | The date and time when the event occurred. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Members[{item}].Links
Members[{item}].Links.OriginOfCondition
The link to the resource that caused the log entry.
OriginOfCondition is a link ("@odata.id": URI
) to another resource.
Members[{item}].Message Member of LogEntryCollection.LogEntryCollection
Description | The log entry details. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].MessageArgs (array) Member of LogEntryCollection.LogEntryCollection
MessageArgs
is an array containing elements of:
MessageArgs[{item}] Member of LogEntryCollection.LogEntryCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].MessageId Member of LogEntryCollection.LogEntryCollection
Description | The MessageId, event data, or OEM-specific information. This property decodes from the entry type. If the entry type is Event , this property contains a Redfish Specification-defined MessageId. If the entry type is SEL , this property contains the Event Data. Otherwise, this property contains OEM-specific information. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.Categories (array) Member of LogEntryCollection.LogEntryCollection
Categories
is an array containing elements of:
Categories[{item}] Member of LogEntryCollection.LogEntryCollection
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Security |
Hardware |
Firmware |
Maintenance |
Administration |
Power |
Cooling |
Invalid User Input |
Other |
Configuration |
Members[{item}].Oem.Hpe.Class Member of LogEntryCollection.LogEntryCollection
Description | The log entry event class. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.ClassDescription Member of LogEntryCollection.LogEntryCollection
Description | The log entry event class description. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.Code Member of LogEntryCollection.LogEntryCollection
Description | The log entry event code. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.Count Member of LogEntryCollection.LogEntryCollection
Description | The occurrence count of the log entry. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.Destination Member of LogEntryCollection.LogEntryCollection
Description | The destination host name or IP address of the remote server that recevied the service event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.EventNumber Member of LogEntryCollection.LogEntryCollection
Description | The event log identification number. Events are numbered in the order in which they are generated. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.Identifier Member of LogEntryCollection.LogEntryCollection
Description | The unique identifier of the service event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.LearnMoreLink Member of LogEntryCollection.LogEntryCollection
Description | The link to troubleshooting information. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members[{item}].Oem.Hpe.RecommendedAction Member of LogEntryCollection.LogEntryCollection
Description | The recommended action for the event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.Repaired Member of LogEntryCollection.LogEntryCollection
Description | The repaired status of the IML event. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.ServiceEvent Member of LogEntryCollection.LogEntryCollection
Description | This indicates a service ticket to be raised for the corresponding event log. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.ServiceEventMessageID Member of LogEntryCollection.LogEntryCollection
Description | This property represents the Embedded Remote Support Message ID. It is applicable only for a Service Event log. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.Severity Member of LogEntryCollection.LogEntryCollection
Description | The log entry event Severity. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Informational |
Informational event |
Caution |
Caution event |
Critical |
Critical event |
Repaired |
Critical or Caution event repaired |
Members[{item}].Oem.Hpe.SubmitStatus Member of LogEntryCollection.LogEntryCollection
Description | The service event log submission status . |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Members[{item}].Oem.Hpe.Updated Member of LogEntryCollection.LogEntryCollection
Description | The date and time of the latest log entry update, for example, 2014-04-15T00:38:00Z. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Members[{item}].Oem.Hpe.UserAction Member of LogEntryCollection.LogEntryCollection
Description | The User action for the event. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Repaired |
The event repaired by user. |
Ignored |
The event ignored by user. |
None |
No user action taken on the event. |
Not Applicable |
User action not applicable for the event. |
Members[{item}].OemRecordFormat Member of LogEntryCollection.LogEntryCollection
Description | The format of an OEM record. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Hpe-IML |
Hpe-iLOEventLog |
Hpe-SL |
Hpe-Event |
Members[{item}].Severity Member of LogEntryCollection.LogEntryCollection
Description | The log entry severity. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
OK |
Warning |
Critical |
Members@odata.count
Member of LogEntryCollection.LogEntryCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
LogService
@odata.type: "#LogService.v1_1_0.LogService"
This resource contains properties for monitoring and configuring an event log service for the resource or service to which it is associated.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/logservices/iel |
GET |
/redfish/v1/systems/{item}/logservices/dpu |
GET POST |
/redfish/v1/systems/{item}/logservices/event |
GET |
/redfish/v1/systems/{item}/logservices/iml |
GET |
/redfish/v1/systems/{item}/logservices/sl |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Entries |
Collection of LogEntry |
DateTime
Member of LogService.v1_1_0.LogService
Description | The current date and time, with UTC offset, that the Log Service uses to set or read time. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Format | date-time |
DateTimeLocalOffset
Member of LogService.v1_1_0.LogService
Description | The UTC offset that the current DateTime property value contains in the +HH:MM format. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
Entries
The URI to this log entries collection resource.
Entries is a link ("@odata.id": URI
) to another resource.
MaxNumberOfRecords
Member of LogService.v1_1_0.LogService
Description | The maximum number of log entries. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
OverWritePolicy
Member of LogService.v1_1_0.LogService
Description | When the log is full, the overwrite policy is enforced. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Unknown |
The overwrite policy is not known or is undefined. |
WrapsWhenFull |
When the log is full, new entries will overwrite previous entries. |
NeverOverwrites |
When the log is full, new entries are discarded. |
ServiceEnabled
Member of LogService.v1_1_0.LogService
Description | An indication of whether this service is enabled. |
Type | boolean |
Read Only | True |
Added | iLO6 1.10 |
Status
Member of LogService.v1_1_0.LogService See the Redfish standard schema and specification for information on common Status object.
Actions
LogService.ClearLog Member of LogService.v1_1_0.LogService There are no parameters for this action.
LogServiceCollection
@odata.type: "#LogServiceCollection.LogServiceCollection"
A Collection of LogService resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/logservices |
GET |
/redfish/v1/systems/{item}/logservices |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
LogService |
Members (array)
Member of LogServiceCollection.LogServiceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of LogServiceCollection.LogServiceCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of LogServiceCollection.LogServiceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Memory
@odata.type: "#Memory.v1_14_0.Memory"
The Memory resource describes a memory module.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memory/{item} |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
MemoryMetrics |
AllocationAlignmentMiB
Member of Memory.v1_14_0.Memory
Description | The boundary which memory regions are allocated on, measured in MiB. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
AllocationIncrementMiB
Member of Memory.v1_14_0.Memory
Description | The size of the smallest unit of allocation for a memory region, thus it is the multiple in which regions are actually reserved. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
BaseModuleType
Member of Memory.v1_14_0.Memory
Description | The base module type of the memory. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
RDIMM |
Registered DIMM |
UDIMM |
UDIMM |
SO_DIMM |
SO_DIMM |
LRDIMM |
Load Reduced |
Mini_RDIMM |
Mini_RDIMM |
Mini_UDIMM |
Mini_UDIMM |
SO_RDIMM_72b |
SORDIMM72b |
SO_UDIMM_72b |
SOUDIMM72b |
SO_DIMM_16b |
SODIMM16b |
SO_DIMM_32b |
SODIMM32b |
Die |
A die within a package. |
BusWidthBits
Member of Memory.v1_14_0.Memory
Description | Bus Width in bits. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
CacheSizeMiB
Member of Memory.v1_14_0.Memory
Description | Total size of the cache portion memory in MiB. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
CapacityMiB
Member of Memory.v1_14_0.Memory
Description | Memory Capacity in MiB. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
ConfigurationLocked
Member of Memory.v1_14_0.Memory
Description | Indicates that the configuration of this memory has been locked |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
DataWidthBits
Member of Memory.v1_14_0.Memory
Description | Data Width in bits. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
DeviceID
Member of Memory.v1_14_0.Memory
Description | Device ID |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
DeviceLocator
Member of Memory.v1_14_0.Memory
Description | Location of the Memory in the platform |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ErrorCorrection
Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NoECC |
No ECC available |
SingleBitECC |
Single bit Data error can be corrected by ECC |
MultiBitECC |
Multi-bit Data errors can be corrected by ECC |
AddressParity |
Address Parity errors can be corrected |
FirmwareApiVersion
Member of Memory.v1_14_0.Memory
Description | Version of API supported by the firmware |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
FirmwareRevision
Member of Memory.v1_14_0.Memory
Description | The firmware revision of this device |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
LogicalSizeMiB
Member of Memory.v1_14_0.Memory
Description | Total size of the logical memory in MiB. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Manufacturer
Member of Memory.v1_14_0.Memory
Description | The Memory manufacturer |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryDeviceType
Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
DDR |
DDR |
DDR2 |
DDR2 |
DDR3 |
DDR3 |
DDR4 |
DDR4 |
DDR4_SDRAM |
DDR4 SDRAM |
DDR4E_SDRAM |
DDR4E SDRAM |
LPDDR4_SDRAM |
LPDDR4 SDRAM |
DDR3_SDRAM |
DDR3 SDRAM |
LPDDR3_SDRAM |
LPDDR3 SDRAM |
DDR2_SDRAM |
DDR2 SDRAM |
DDR2_SDRAM_FB_DIMM |
DDR2 SDRAM FB_DIMM |
DDR2_SDRAM_FB_DIMM_PROBE |
DDR2 SDRAM FB_DIMM PROBE |
DDR_SGRAM |
DDR SGRAM |
DDR_SDRAM |
DDR SDRAM |
ROM |
ROM |
SDRAM |
SDRAM |
EDO |
EDO |
FastPageMode |
Fast Page Mode |
PipelinedNibble |
Pipelined Nibble |
Logical |
Logical Non-volatile device. |
DDR5 |
DDR5 |
MemoryLocation
MemoryLocation.Channel Member of Memory.v1_14_0.Memory
Description | Channel number in which Memory is connected |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryLocation.MemoryController Member of Memory.v1_14_0.Memory
Description | Memory controller number in which Memory is connected |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryLocation.Slot Member of Memory.v1_14_0.Memory
Description | Slot number in which Memory is connected |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryLocation.Socket Member of Memory.v1_14_0.Memory
Description | Socket number in which Memory is connected |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryMedia (array)
Member of Memory.v1_14_0.Memory
MemoryMedia
is an array containing elements of:
MemoryMedia[{item}] Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
DRAM |
DRAM media |
NAND |
NAND media |
Intel3DXPoint |
Intel 3D XPoint media |
Proprietary |
Proprietary media |
MemorySubsystemControllerManufacturerID
Member of Memory.v1_14_0.Memory
Description | The manufacturer ID of the memory subsystem controller of this memory module. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MemorySubsystemControllerProductID
Member of Memory.v1_14_0.Memory
Description | The product ID of the memory subsystem controller of this memory module. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryType
Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
DRAM |
DRAM |
NVDIMM_N |
NVDIMM_N as defined by JEDEC. |
NVDIMM_F |
NVDIMM_F as defined by JEDEC. |
NVDIMM_P |
NVDIMM_P as defined by JEDEC. |
IntelOptane |
The memory module is Intel Optane DC Persistent Memory and composed of a combination of non-volatile and volatile memory. |
ModuleManufacturerID
Member of Memory.v1_14_0.Memory
Description | The manufacturer ID of this memory module. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ModuleProductID
Member of Memory.v1_14_0.Memory
Description | The product ID of this memory module. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
NonVolatileSizeMiB
Member of Memory.v1_14_0.Memory
Description | Total size of the non-volatile portion memory in MiB. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Armed
Member of Memory.v1_14_0.Memory
Description | Specifies the current backup-ready status of the NVDIMM_N if available. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Attributes (array)
Member of Memory.v1_14_0.Memory
Attributes
is an array containing elements of:
Attributes[{item}] Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
HpeSmartMemory |
This DIMM is HPE Smart Memory |
HpeStandardMemory |
This DIMM is HPE Standard Memory |
HpeLogicalNVDIMM |
This DIMM is HPE Logical Memory. |
Oem.Hpe.BaseModuleType
Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
BurstEDO |
FastPage |
Synchronous |
EDO |
LRDIMM |
RDRAM |
RDIMM |
UDIMM |
NVDIMM |
NVDIMM-N |
LRNVDIMM |
SO_RDIMM_72b |
SO_UDIMM_72b |
PMM |
Oem.Hpe.BlocksRead
Member of Memory.v1_14_0.Memory
Description | Number of blocks read for the lifetime of the Memory. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.BlocksWritten
Member of Memory.v1_14_0.Memory
Description | Number of blocks written for the lifetime of the Memory. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DIMMManufacturingDate
Member of Memory.v1_14_0.Memory
Description | Module manufacturing date in YYWW format. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DIMMStatus
Member of Memory.v1_14_0.Memory
Description | Specifies memory module status and whether the module in use. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The status of the DIMM is unknown. |
Other |
DIMM status that does not fit any of these definitions. |
NotPresent |
DIMM is not present. |
PresentUnused |
DIMM is present but unused. |
GoodInUse |
DIMM is functioning properly and currently in use. |
AddedButUnused |
DIMM is added but currently unused. |
UpgradedButUnused |
DIMM is upgraded but currently unused. |
ExpectedButMissing |
DIMM is expected but missing. |
DoesNotMatch |
DIMM type does not match. |
NotSupported |
DIMM is not supported. |
ConfigurationError |
Configuration error in DIMM. |
Degraded |
DIMM state is degraded. |
PresentSpare |
DIMM is present but used as spare. |
GoodPartiallyInUse |
DIMM is functioning properly but partially in use. |
MapOutConfiguration |
DIMM mapped out due to configuration error. |
MapOutError |
DIMM mapped out due to training failure. |
Oem.Hpe.MaxOperatingSpeedMTs
Member of Memory.v1_14_0.Memory
Description | Maximum capable speed of the device, in megatransfers per second (MT/s). |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.MinimumVoltageVoltsX10
Member of Memory.v1_14_0.Memory
Description | The minimum DIMM voltage multiplied by 10, for example, 1.2v = 12. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PartNumber
Member of Memory.v1_14_0.Memory
Description | The HPE product part number of this device |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PredictedMediaLifeLeftPercent
Member of Memory.v1_14_0.Memory
Description | The percentage of media life left. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ProductName
Member of Memory.v1_14_0.Memory
Description | friendly product name from SMBIOS 202 record |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.RelatedBackupStores (array)
Member of Memory.v1_14_0.Memory
RelatedBackupStores
is an array containing elements of:
RelatedBackupStores[{item}].@odata.id Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Oem.Hpe.RelatedPhysicalDIMMs (array)
Member of Memory.v1_14_0.Memory
RelatedPhysicalDIMMs
is an array containing elements of:
RelatedPhysicalDIMMs[{item}].@odata.id Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Oem.Hpe.RelatedPowerBackupUnitBays (array)
Member of Memory.v1_14_0.Memory
RelatedPowerBackupUnitBays
is an array containing elements of:
RelatedPowerBackupUnitBays[{item}] Member of Memory.v1_14_0.Memory
Description | Battery backup unit bay number. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SPDBytes (array)
Member of Memory.v1_14_0.Memory
SPDBytes
is an array containing elements of:
SPDBytes[{item}] Member of Memory.v1_14_0.Memory
Description | The SPD Bytes in the DIMM |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SpareBlockLeftPercent
Member of Memory.v1_14_0.Memory
Description | The percentage of the number of spare blocks remaining. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.VendorName
Member of Memory.v1_14_0.Memory
Description | Vendor Name decoded from VendorID |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
OperatingMemoryModes (array)
Member of Memory.v1_14_0.Memory
OperatingMemoryModes
is an array containing elements of:
OperatingMemoryModes[{item}] Member of Memory.v1_14_0.Memory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Volatile |
Volatile memory |
PMEM |
Persistent memory, byte accesible through system address space |
Block |
Block accessible system memory |
OperatingSpeedMhz
Member of Memory.v1_14_0.Memory
Description | Operating speed of Memory in MHz |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PartNumber
Member of Memory.v1_14_0.Memory
Description | The product part number of this device |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PersistentRegionNumberLimit
Member of Memory.v1_14_0.Memory
Description | Total number of persistent regions this Memory can support. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PersistentRegionSizeLimitMiB
Member of Memory.v1_14_0.Memory
Description | Total size of persistent regions in MiB |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PersistentRegionSizeMaxMiB
Member of Memory.v1_14_0.Memory
Description | Maximum size of a single persistent region in MiB. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
RankCount
Member of Memory.v1_14_0.Memory
Description | Number of ranks available in the Memory |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Regions (array)
Member of Memory.v1_14_0.Memory
Regions
is an array containing elements of:
Regions[{item}].MemoryClassification Member of Memory.v1_14_0.Memory
Description | Classification of memory occupied by the given memory region |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Volatile |
Volatile memory |
ByteAccessiblePersistent |
Byte accessible persistent memory |
Block |
Block accesible memory |
Regions[{item}].PassphraseEnabled Member of Memory.v1_14_0.Memory
Description | State of the passphrase for this region |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Regions[{item}].RegionId Member of Memory.v1_14_0.Memory
Description | Unique region ID representing a specific region within the Memory |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Regions[{item}].SizeMiB Member of Memory.v1_14_0.Memory
Description | Size of this memory region in MiB |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
SecurityCapabilities
SecurityCapabilities.ConfigurationLockCapable Member of Memory.v1_14_0.Memory
Description | Support for configuration locking |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
SecurityCapabilities.DataLockCapable Member of Memory.v1_14_0.Memory
Description | Support for data locking |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
SecurityCapabilities.PassphraseCapable Member of Memory.v1_14_0.Memory
Description | Memory passphrase set capability |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
SecurityCapabilities.PassphraseLockLimit Member of Memory.v1_14_0.Memory
Description | Maximum number of incorrect passphrase attempts allowed before memory is locked. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
SecurityState
Member of Memory.v1_14_0.Memory
Description | The current security state of this Memory |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Secure mode is enabled and access to the data is unlocked |
Disabled |
Secure mode is disabled |
Locked |
Secure mode is enabled and access to the data is locked |
Passphraselimit |
Number of attempts to unlock the Memory exceeded limit |
SerialNumber
Member of Memory.v1_14_0.Memory
Description | The serial number of this device |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of Memory.v1_14_0.Memory See the Redfish standard schema and specification for information on common Status object.
SubsystemDeviceID
Member of Memory.v1_14_0.Memory
Description | Subsystem Device ID |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SubsystemVendorID
Member of Memory.v1_14_0.Memory
Description | SubSystem Vendor ID |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
VendorID
Member of Memory.v1_14_0.Memory
Description | Vendor ID |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
VolatileRegionNumberLimit
Member of Memory.v1_14_0.Memory
Description | Total number of volatile regions this Memory can support. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
VolatileRegionSizeLimitMiB
Member of Memory.v1_14_0.Memory
Description | Total size of volatile regions in MiB |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
VolatileRegionSizeMaxMiB
Member of Memory.v1_14_0.Memory
Description | Maximum size of a single volatile region in MiB. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
VolatileSizeMiB
Member of Memory.v1_14_0.Memory
Description | Total size of the volitile portion memory in MiB. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryChunks
@odata.type: "#MemoryChunks.v1_2_3.MemoryChunks"
The MemoryChunks resource describes a Memory Chunk and its configuration.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memorydomains/{item}/memorychunks/{item} |
GET DELETE |
AddressRangeType
Member of MemoryChunks.v1_2_3.MemoryChunks
Description | Memory type of this memory chunk |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
PMEM |
Byte accessible persistent memory |
InterleaveSets (array)
Member of MemoryChunks.v1_2_3.MemoryChunks
InterleaveSets
is an array containing elements of:
InterleaveSets[{item}].Memory
Describes a memory device of the interleave set.
Memory is a link ("@odata.id": URI
) to another resource.
InterleaveSets[{item}].MemoryLevel Member of MemoryChunks.v1_2_3.MemoryChunks
Description | Level of the interleave set for multi-level tiered memory. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
InterleaveSets[{item}].OffsetMiB Member of MemoryChunks.v1_2_3.MemoryChunks
Description | Offset within the DIMM that corresponds to the start of this memory region, with units in MiB |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
InterleaveSets[{item}].RegionId Member of MemoryChunks.v1_2_3.MemoryChunks
Description | DIMM region identifier |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
InterleaveSets[{item}].SizeMiB Member of MemoryChunks.v1_2_3.MemoryChunks
Description | Size of this memory region in MiB |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
IsMirrorEnabled
Member of MemoryChunks.v1_2_3.MemoryChunks
Description | Mirror Enabled status |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
IsSpare
Member of MemoryChunks.v1_2_3.MemoryChunks
Description | Spare enabled status |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryChunkSizeMiB
Member of MemoryChunks.v1_2_3.MemoryChunks
Description | Size of the memory chunk in MiB |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.MemoryChunkSizePercentage
Member of MemoryChunks.v1_2_3.MemoryChunks
Description | Size of chunk in percent of total capacity. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Status
Member of MemoryChunks.v1_2_3.MemoryChunks See the Redfish standard schema and specification for information on common Status object.
MemoryChunksCollection
@odata.type: "#MemoryChunksCollection.MemoryChunksCollection"
A Collection of MemoryChunks resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memorydomains/{item}/memorychunks |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
MemoryChunks |
Members (array)
Member of MemoryChunksCollection.MemoryChunksCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MemoryChunksCollection.MemoryChunksCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of MemoryChunksCollection.MemoryChunksCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
MemoryCollection
@odata.type: "#MemoryCollection.MemoryCollection"
A Collection of Memory resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memory |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Memory |
Members (array)
Member of MemoryCollection.MemoryCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MemoryCollection.MemoryCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of MemoryCollection.MemoryCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.AmpModeActive
Member of MemoryCollection.MemoryCollection
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Unknown |
The management software cannot determine the AMP, host OS may not have provided it yet. |
Other |
|
None |
The management software cannot determine the AMP, or the system is not configured for AMP. |
Mirroring |
The system is configured for mirrored memory protection. All memory banks are duplicated in mirrored memory, as opposed to only one for online spare memory. If enough ECC errors occur, the spare memory is activated and the memory that is experiencing the errors is disabled. |
OnlineSpare |
A single spare bank of memory is set aside at boot time. If enough ECC errors occur, the spare memory is activated and the memory that is experiencing the errors is disabled. |
RAIDXOR |
The system is configured for AMP with the XOR engine. |
AdvancedECC |
The system is configured for AMP with the Advanced ECC engine. |
Lockstep |
|
A3DC |
The system is configured for AMP with A3DC. |
DIMMECC |
The system is configured for AMP with DIMM ECC (Error Correcting Code) only. |
Oem.Hpe.AmpModeStatus
Member of MemoryCollection.MemoryCollection
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Unknown |
The management software cannot determine the status, host OS may not have provided it yet. |
Other |
The system does not support AMP, or the management software cannot determine the status. |
NotProtected |
The system supports AMP, but the feature is disabled. |
Protected |
The system supports AMP. The feature is enabled but not engaged. |
Degraded |
The system was protected, but AMP is engaged. Therefore, AMP is no longer available. |
DIMMECC |
The system is protected by DIMM ECC (Error Correcting Code) only. |
Mirroring |
The system is protected by AMP in the mirrored mode. No DIMM faults have been detected. |
DegradedMirroring |
The system is protected by AMP in the mirrored mode. One or more DIMM faults have been detected. |
OnlineSpare |
The system is protected by AMP in the hot spare mode. No DIMM faults have been detected. |
DegradedOnlineSpare |
|
RAIDXOR |
The system is protected by AMP in the XOR memory mode. No DIMM faults have been detected. |
DegradedRAIDXOR |
The system is protected by AMP in the XOR memory mode. One or more DIMM faults have been detected. |
AdvancedECC |
The system is protected by AMP in the Advanced ECC mode. |
DegradedAdvancedECC |
The system is protected by AMP in the Advanced ECC mode. One or more DIMM faults have been detected. |
Lockstep |
|
DegradedLockstep |
|
A3DC |
The system is protected by AMP in the A3DC mode. |
DegradedA3DC |
The system is protected by AMP in the A3DC mode. One or more DIMM faults have been deteced. |
Unsupported |
Oem.Hpe.AmpModeSupported (array)
Member of MemoryCollection.MemoryCollection
AmpModeSupported
is an array containing elements of:
AmpModeSupported[{item}] Member of MemoryCollection.MemoryCollection
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
RAIDXOR |
The system can be configured for AMP using the XOR engine. |
DualBoardMirroring |
The system can be configured for mirrored advanced memory protection in a dual memory board configuration. The mirrored memory can be swapped with memory on the same memory board or with memory on the second memory board. |
SingleBoardMirroring |
The system can be configured for mirrored advanced memory protection in a single memory board. |
AdvancedECC |
The system can be configured for Advanced ECC. |
Mirroring |
The system can be configured for mirrored AMP. |
OnlineSpare |
The system can be configured for online spare AMP. |
OnlineSpareRank |
The system can be configured for Online Spare Rank AMP. |
OnlineSpareChannel |
The system can be configured for Online Spare Channel AMP. |
IntersocketMirroring |
The system can be configured for mirrored intersocket AMP between the memory of two processors or boards. |
IntrasocketMirroring |
The system can be configured for mirrored intrasocket AMP between the memory of a single processor or board. |
Lockstep |
|
A3DC |
The system can be configured for A3DC. |
None |
The system cannot be configured for AMP. |
DIMMECC |
The system can be configured for DIMM ECC (Error Correcting Code) only. |
Oem.Hpe.MemoryList (array)
Member of MemoryCollection.MemoryCollection
MemoryList
is an array containing elements of:
MemoryList[{item}].BoardCpuNumber Member of MemoryCollection.MemoryCollection
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryList[{item}].BoardMemoryType Member of MemoryCollection.MemoryCollection
Description | Board Memory Type - DIMM/HBM. |
Type | string or null |
Read Only | True |
Added | iLO6 1.40 |
MemoryList[{item}].BoardNumberOfSockets Member of MemoryCollection.MemoryCollection
Description | The number of present memory module sockets. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryList[{item}].BoardOperationalFrequency Member of MemoryCollection.MemoryCollection
Description | The frequency at which memory on the board is operating in MHz. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryList[{item}].BoardOperationalVoltage Member of MemoryCollection.MemoryCollection
Description | The voltage at which memory on the board is operating in mV. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryList[{item}].BoardTotalMemorySize Member of MemoryCollection.MemoryCollection
Description | The total size of the memory populated on the board in MB. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MemoryDomain
@odata.type: "#MemoryDomain.v1_2_1.MemoryDomain"
The MemoryDomain resource describes a Memory Domain and its configuration. Memory Domains are used to indicate to the client which Memory (DIMMs) can be grouped together in Memory Chunks to form interleave sets or otherwise grouped together.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memorydomains/{item} |
GET |
AllowsBlockProvisioning
Member of MemoryDomain.v1_2_1.MemoryDomain
Description | Indicates if this Memory Domain supports the provisioning of blocks of memory. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
AllowsMemoryChunkCreation
Member of MemoryDomain.v1_2_1.MemoryDomain
Description | Indicates if this Memory Domain supports the creation of Memory Chunks. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
AllowsMirroring
Member of MemoryDomain.v1_2_1.MemoryDomain
Description | Indicates if this Memory Domain supports the creation of Memory Chunks with mirroring enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
AllowsSparing
Member of MemoryDomain.v1_2_1.MemoryDomain
Description | Indicates if this Memory Domain supports the creation of Memory Chunks with sparing enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
InterleavableMemorySets (array)
Member of MemoryDomain.v1_2_1.MemoryDomain
InterleavableMemorySets
is an array containing elements of:
InterleavableMemorySets[{item}].MemorySet (array) Member of MemoryDomain.v1_2_1.MemoryDomain
MemorySet
is an array containing elements of:
MemorySet[{item}].@odata.id Member of MemoryDomain.v1_2_1.MemoryDomain
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
InterleavableMemorySets[{item}].MemorySet@odata.count Member of MemoryDomain.v1_2_1.MemoryDomain
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
MemoryChunks
A reference to the collection of Memory Chunks associated with this Memory Domain.
MemoryChunks is a link ("@odata.id": URI
) to another resource.
MemoryDomainCollection
@odata.type: "#MemoryDomainCollection.MemoryDomainCollection"
A Collection of MemoryDomain resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memorydomains |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
MemoryDomain |
Members (array)
Member of MemoryDomainCollection.MemoryDomainCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MemoryDomainCollection.MemoryDomainCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of MemoryDomainCollection.MemoryDomainCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
MemoryMetrics
@odata.type: "#MemoryMetrics.v1_7_3.MemoryMetrics"
The MemoryMetrics schema shall contain the memory metrics for a memory device or system memory summary in a Redfish implementation.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/memory/{item}/memorymetrics |
GET |
Oem.Hpe.PageRetirementCounts
Member of MemoryMetrics.v1_7_3.MemoryMetrics
Description | This property shall contain Memory page counters for this resource. |
Type | integer |
Read Only | True |
Added | iLO6 1.61 |
OperatingSpeedMHz
Member of MemoryMetrics.v1_7_3.MemoryMetrics
Description | Operating speed of memory in MHz or MT/s as appropriate. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.61 |
MessageRegistryFile
@odata.type: "#MessageRegistryFile.v1_0_4.MessageRegistryFile"
The MessageRegistryFile resource describes the Schema File locator resource.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/registries/{item} |
GET |
Languages (array)
Member of MessageRegistryFile.v1_0_4.MessageRegistryFile
Languages
is an array containing elements of:
Languages[{item}] Member of MessageRegistryFile.v1_0_4.MessageRegistryFile
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Location (array)
Member of MessageRegistryFile.v1_0_4.MessageRegistryFile
Location
is an array containing elements of:
Location[{item}].Language Member of MessageRegistryFile.v1_0_4.MessageRegistryFile
Description | The RFC 5646 language code for this schema or registry item. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Location[{item}].Uri Member of MessageRegistryFile.v1_0_4.MessageRegistryFile
Description | Link to locally available URI for schema. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Registry
Member of MessageRegistryFile.v1_0_4.MessageRegistryFile
Description | The Registry Name, Major and Minor version used in MessageID construction. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
MessageRegistryFileCollection
@odata.type: "#MessageRegistryFileCollection.MessageRegistryFileCollection"
A Collection of MessageRegistryFile resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/registries |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
MessageRegistryFile |
Members (array)
Member of MessageRegistryFileCollection.MessageRegistryFileCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MessageRegistryFileCollection.MessageRegistryFileCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of MessageRegistryFileCollection.MessageRegistryFileCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
MetricDefinition
@odata.type: "#MetricDefinition.v1_0_0.MetricDefinition"
The metadata information about a metric.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricdefinitions/{item} |
GET |
Calculable
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | The types of calculations which can be applied to the metric reading. This property provides information to the client on the suitability of calculatiion using the metric reading. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NonCalculatable |
No calculations should be performed on the metric reading. |
Summable |
The sum of the metric reading across multiple instances is meaningful. |
NonSummable |
The sum of the metric reading across multiple instances is not meaningful. |
CalculationAlgorithm
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | The calculation which is performed on a source metric to obtain the metric being defined. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Average |
The metric is calculated as the average of a metric reading over a sliding time interval. |
Maximum |
The metric is calculated as the maximum value of a metric reading over during a time interval. |
Minimum |
The metric is calculated as the minimum value of a metric reading over a sliding time interval. |
Implementation
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | The implementation of the metric. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
PhysicalSensor |
The metric is implemented as a physical sensor. |
Calculated |
The metric is implemented by applying a calculation on another metric property. The calculation is specified in the CalculationAlgorithm property. |
Synthesized |
The metric is implemented by applying a calculation on one or more metric properties. (The calculation is not specified. For expressing generalized formula, see MathSON). |
DigitalMeter |
The metric is implemented as digital meter. |
IsLinear
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | Indicates whether the metric values are linear (vs non-linear). |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
MaxReadingRange
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | Maximum value for metric reading. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MetricDataType
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | The data type of the related metric values. The property provides information to the client on the nature of the metric reading. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Boolean |
The data type follows the JSON Boolean definition. |
DateTime |
The data type follows the JSON String definition with the Date-Time format applied. |
Decimal |
The data type follows the JSON Decimal definition. |
Integer |
The data type follows the JSON Integer definition. |
String |
The data type follows the JSON String definition. |
Enumeration |
The data type follows the JSON String definition with a set of enumerations defined. |
MetricProperties (array)
Member of MetricDefinition.v1_0_0.MetricDefinition
MetricProperties
is an array containing elements of:
MetricProperties[{item}] Member of MetricDefinition.v1_0_0.MetricDefinition
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MetricType
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | Specifies the type of metric provided. The property provides information to the client on how the metric can be handled. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Numeric |
The metric is a numeric metric. The metric value is any real number. |
Discrete |
The metric is a discrete metric. The metric value is discrete. The possible values are listed in the DiscreteValues property. |
Gauge |
The metric is a gauge metric. The metric value is a real number. When the metric value reaches the gauges extrema, it stays at that value, until the reading falls within the extrema. |
Counter |
The metric is a counter metric. The metric reading is a non-negative integer which increases monotonically. When a counter reaches its maximum, the value resets to 0 and resumes counting. |
Countdown |
The metric is a countdown metric. The metric reading is a non-negative integer which decreases monotonically. When a counter reaches its minimum, the value resets to preset value and resumes counting down. |
MinReadingRange
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | Minimum value for metric reading. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Units
Member of MetricDefinition.v1_0_0.MetricDefinition
Description | The units of measure for this metric. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
MetricDefinitionCollection
@odata.type: "#MetricDefinitionCollection.MetricDefinitionCollection"
A Collection of MetricDefinition resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricdefinitions |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
MetricDefinition |
Members (array)
Member of MetricDefinitionCollection.MetricDefinitionCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MetricDefinitionCollection.MetricDefinitionCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of MetricDefinitionCollection.MetricDefinitionCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
MetricReport
@odata.type: "#MetricReport.v1_0_0.MetricReport"
The metric definitions used to create a metric report.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricreports/{item} |
GET |
MetricReportDefinition
The metric definitions used to create a metric report.
MetricReportDefinition is a link ("@odata.id": URI
) to another resource.
MetricValues (array)
Member of MetricReport.v1_0_0.MetricReport
MetricValues
is an array containing elements of:
MetricValues[{item}].MetricDefinition
A link to the Metric Definition.
MetricDefinition is a link ("@odata.id": URI
) to another resource.
MetricValues[{item}].MetricId Member of MetricReport.v1_0_0.MetricReport
Description | The metric definitions identifier for this metric. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MetricValues[{item}].MetricValue Member of MetricReport.v1_0_0.MetricReport
Description | The value identifies this resource. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MetricValues[{item}].Timestamp Member of MetricReport.v1_0_0.MetricReport
Description | The time when the value of the metric is obtained. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
MetricReportCollection
@odata.type: "#MetricReportCollection.MetricReportCollection"
A Collection of MetricReport resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricreports |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
MetricReport |
Members (array)
Member of MetricReportCollection.MetricReportCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MetricReportCollection.MetricReportCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of MetricReportCollection.MetricReportCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
MetricReportDefinition
@odata.type: "#MetricReportDefinition.v1_4_2.MetricReportDefinition"
A set of metrics that are collected into a metric report.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricreportdefinitions/{item} |
GET |
MetricProperties (array)
Member of MetricReportDefinition.v1_4_2.MetricReportDefinition
MetricProperties
is an array containing elements of:
MetricProperties[{item}] Member of MetricReportDefinition.v1_4_2.MetricReportDefinition
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MetricReport
Specifies the location where the resultant metric report is placed.
MetricReport is a link ("@odata.id": URI
) to another resource.
MetricReportDefinitionType
Member of MetricReportDefinition.v1_4_2.MetricReportDefinition
Description | Indicates when the metric report is generated. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Periodic |
The metric report is generated at a periodic time interval, specified in the Schedule property. |
OnChange |
The metric report is generated when any of the metric values change. |
OnRequest |
The metric report is generated when a HTTP GET is performed on the specified metric report. |
Metrics (array)
Member of MetricReportDefinition.v1_4_2.MetricReportDefinition
Metrics
is an array containing elements of:
Metrics[{item}].CollectionDuration Member of MetricReportDefinition.v1_4_2.MetricReportDefinition
Description | Specifies the duration over which the function is computed. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Metrics[{item}].CollectionFunction Member of MetricReportDefinition.v1_4_2.MetricReportDefinition
Description | Specifies the function to apply to the list of metric properties. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Average |
The metric is calculated as the average of a metric reading over a sliding time interval. |
Maximum |
The metric is calculated as the maximum value of a metric reading over during a time interval. |
Minimum |
The metric is calculated as the minimum value of a metric reading over a sliding time interval. |
Summation |
The metric is calculated as the sum of the values over a sliding time interval. |
Metrics[{item}].CollectionTimeScope Member of MetricReportDefinition.v1_4_2.MetricReportDefinition
Description | The time scope of the related metric values. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Point |
The corresponding metric values apply to a point in time. On the corresponding metric value instances, the value of Timestamp shall specify the point in time. |
Interval |
The corresponding metric values apply to a time interval. On the corresponding metric value instances, the value of Timestamp shall specify the end of the time interval and Duration shall specify its duration. |
StartupInterval |
The corresponding metric values apply to a time interval that began at the startup of the measured resource (i.e. the Resources associated by Links.MetricDefinitionForResources). On the corresponding metric value instances, the value of Timestamp shall specify the end of the time interval. The value of Duration shall specifies the duration between startup of the resource and TimeStamp. |
Metrics[{item}].MetricId Member of MetricReportDefinition.v1_4_2.MetricReportDefinition
Description | Specifies the label for the metric definition which is derived by applying the CollectionFunction to the metric property. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Metrics[{item}].MetricProperties (array) Member of MetricReportDefinition.v1_4_2.MetricReportDefinition
MetricProperties
is an array containing elements of:
MetricProperties[{item}] Member of MetricReportDefinition.v1_4_2.MetricReportDefinition
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Schedule
Schedule.EnabledDaysOfMonth (array) Member of MetricReportDefinition.v1_4_2.MetricReportDefinition
EnabledDaysOfMonth
is an array containing elements of:
EnabledDaysOfMonth[{item}] Member of MetricReportDefinition.v1_4_2.MetricReportDefinition
Type | integer or null |
Read Only | True |
Added | iLO6 1.51 |
Schedule.InitialStartTime Member of MetricReportDefinition.v1_4_2.MetricReportDefinition
Description | The date and time when the initial occurrence is scheduled to occur. |
Type | string or null |
Read Only | False |
Added | iLO6 1.51 |
Format | date-time |
Schedule.RecurrenceInterval Member of MetricReportDefinition.v1_4_2.MetricReportDefinition
Description | The duration between consecutive occurrences. |
Type | string or null |
Read Only | False |
Added | iLO6 1.51 |
Status
Member of MetricReportDefinition.v1_4_2.MetricReportDefinition See the Redfish standard schema and specification for information on common Status object.
MetricReportDefinitionCollection
@odata.type: "#MetricReportDefinitionCollection.MetricReportDefinitionCollection"
A Collection of MetricReportDefinition resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/metricreportdefinitions |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
MetricReportDefinition |
Members (array)
Member of MetricReportDefinitionCollection.MetricReportDefinitionCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of MetricReportDefinitionCollection.MetricReportDefinitionCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of MetricReportDefinitionCollection.MetricReportDefinitionCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PCIeDevice
@odata.type: "#PCIeDevice.v1_5_0.PCIeDevice"
This is the schema definition for the PCIeDevice resource. It represents the properties of a PCIe Device attached to a System.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/pciedevices/{item} |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
PCIeFunctions |
PCIeFunction |
AssetTag
Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The user-assigned asset tag for this PCIe device. |
Type | string or null |
Read Only | False |
Added | iLO6 1.20 |
DeviceType
Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The device type for this PCIe device. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
SingleFunction |
A single-function PCIe device. |
MultiFunction |
A multi-function PCIe device. |
Simulated |
A PCIe device which is not currently physically present, but is being simulated by the PCIe infrastructure. |
FirmwareVersion
Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The version of firmware for this PCIe device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Manufacturer
Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The manufacturer of this PCIe device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Model
Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The model number for the PCIe device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.FirmwareVersion (array)
Member of PCIeDevice.v1_5_0.PCIeDevice
FirmwareVersion
is an array containing elements of:
FirmwareVersion[{item}].ComponentName Member of PCIeDevice.v1_5_0.PCIeDevice
Description | Name of GPU cores |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
FirmwareVersion[{item}].VersionString Member of PCIeDevice.v1_5_0.PCIeDevice
Description | Version string of GPU cores |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
PCIeFunctions
The link to the collection of PCIe functions associated with this PCIe device.
PCIeFunctions is a link ("@odata.id": URI
) to another resource.
PCIeInterface
PCIeInterface.LanesInUse Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The number of PCIe lanes in use by this device. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PCIeInterface.MaxLanes Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The number of PCIe lanes supported by this device. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PCIeInterface.MaxPCIeType Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The highest version of the PCIe specification supported by this device. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Gen1 |
A PCIe v1.0 slot. |
Gen2 |
A PCIe v2.0 slot. |
Gen3 |
A PCIe v3.0 slot. |
Gen4 |
A PCIe v4.0 slot. |
Gen5 |
A PCIe v5.0 slot. |
PCIeInterface.PCIeType Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The version of the PCIe specification in use by this device. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Gen1 |
A PCIe v1.0 slot. |
Gen2 |
A PCIe v2.0 slot. |
Gen3 |
A PCIe v3.0 slot. |
Gen4 |
A PCIe v4.0 slot. |
Gen5 |
A PCIe v5.0 slot. |
PartNumber
Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The part number for this PCIe device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SKU
Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The SKU for this PCIe device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SerialNumber
Member of PCIeDevice.v1_5_0.PCIeDevice
Description | The serial number for this PCIe device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of PCIeDevice.v1_5_0.PCIeDevice See the Redfish standard schema and specification for information on common Status object.
PCIeDeviceCollection
@odata.type: "#PCIeDeviceCollection.PCIeDeviceCollection"
The collection of PCIeDevice Resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/pciedevices |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
PCIeDevice |
Members (array)
Member of PCIeDeviceCollection.PCIeDeviceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of PCIeDeviceCollection.PCIeDeviceCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of PCIeDeviceCollection.PCIeDeviceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PCIeFunction
@odata.type: "#PCIeFunction.v1_2_3.PCIeFunction"
The schema definition for the PCIeFunction Resource. It represents the properties of a PCIeFunction attached to a System.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/pciedevices/{item}/pciefunctions/{item} |
GET |
ClassCode
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The Class Code of this PCIe function. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
DeviceClass
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The class for this PCIe function. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
UnclassifiedDevice |
An unclassified device. |
MassStorageController |
A mass storage controller. |
NetworkController |
A network controller. |
DisplayController |
A display controller. |
MultimediaController |
A multimedia controller. |
MemoryController |
A memory controller. |
Bridge |
A bridge. |
CommunicationController |
A communication controller. |
GenericSystemPeripheral |
A generic system peripheral. |
InputDeviceController |
An input device controller. |
DockingStation |
A docking station. |
Processor |
A processor. |
SerialBusController |
A serial bus controller. |
WirelessController |
A wireless controller. |
IntelligentController |
An intelligent controller. |
SatelliteCommunicationsController |
A satellite communications controller. |
EncryptionController |
An encryption controller. |
SignalProcessingController |
A signal processing controller. |
ProcessingAccelerators |
A processing accelerators. |
NonEssentialInstrumentation |
A non-essential instrumentation. |
Coprocessor |
A coprocessor. |
UnassignedClass |
An unassigned class. |
Other |
A other class. The function Device Class Id needs to be verified. |
DeviceId
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The Device ID of this PCIe function. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
FunctionId
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The PCIe Function Number. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
FunctionType
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The type of the PCIe function. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Physical |
A physical PCIe function. |
Virtual |
A virtual PCIe function. |
RevisionId
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The Revision ID of this PCIe function. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of PCIeFunction.v1_2_3.PCIeFunction See the Redfish standard schema and specification for information on common Status object.
SubsystemId
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The Subsystem ID of this PCIe function. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SubsystemVendorId
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The Subsystem Vendor ID of this PCIe function. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
VendorId
Member of PCIeFunction.v1_2_3.PCIeFunction
Description | The Vendor ID of this PCIe function. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PCIeFunctionCollection
@odata.type: "#PCIeFunctionCollection.PCIeFunctionCollection"
The collection of PCIeFunction Resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/pciedevices/{item}/pciefunctions |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
PCIeFunction |
Members (array)
Member of PCIeFunctionCollection.PCIeFunctionCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of PCIeFunctionCollection.PCIeFunctionCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of PCIeFunctionCollection.PCIeFunctionCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PCIeSlots
@odata.type: "#PCIeSlots.v1_3_0.PCIeSlots"
The PCIeSlots schema describes PCIe slot properties.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/pcieslots |
GET |
Slots (array)
Member of PCIeSlots.v1_3_0.PCIeSlots
Slots
is an array containing elements of:
Slots[{item}].HotPluggable Member of PCIeSlots.v1_3_0.PCIeSlots
Description | An indication of whether this PCIe slot supports hotplug. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Slots[{item}].Lanes Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The number of PCIe lanes supported by this slot. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Slots[{item}].Location Slots[{item}].Location.PartLocation Slots[{item}].Location.PartLocation.LocationOrdinalValue Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The number that represents the location of the part. If LocationType is slot and this unit is in slot 2, the LocationOrdinalValue is 2. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Slots[{item}].Location.PartLocation.LocationType Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The location types for PartLocation. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Slot |
The slot as the type of location. |
Bay |
The bay as the type of location. |
Connector |
The connector as the type of location. |
Socket |
The socket as the type of location. |
Embedded |
Embedded within a part. |
Slots[{item}].Location.PartLocation.Orientation Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The orientation for the ordering of the part location ordinal value. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
FrontToBack |
The ordering for LocationOrdinalValue is front to back. |
BackToFront |
The ordering for the LocationOrdinalValue is back to front. |
TopToBottom |
The ordering for the LocationOrdinalValue is top to bottom. |
BottomToTop |
The ordering for LocationOrdinalValue is bottom to top. |
LeftToRight |
The ordering for the LocationOrdinalValue is left to right. |
RightToLeft |
The ordering for the LocationOrdinalValue is right to left. |
Slots[{item}].Location.PartLocation.Reference Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The reference area for the location of the part. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Top |
The part is in the top of the unit. |
Bottom |
The part is in the bottom of the unit. |
Front |
The part is in the front of the unit. |
Rear |
The part is in the rear of the unit. |
Left |
The part is on the left side of of the unit. |
Right |
The part is on the right side of the unit. |
Middle |
The part is in the middle of the unit. |
Slots[{item}].Location.PartLocation.ServiceLabel Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The label of the part location, such as a silk-screened name or a printed label. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Slots[{item}].Location.Placement Slots[{item}].Location.Placement.AdditionalInfo Member of PCIeSlots.v1_3_0.PCIeSlots
Description | Area designation or other additional info. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Slots[{item}].Location.Placement.Rack Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The name of a rack location within a row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Slots[{item}].Location.Placement.RackOffset Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The vertical location of the item, in terms of RackOffsetUnits. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Slots[{item}].Location.Placement.RackOffsetUnits Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The type of rack unit in use. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OpenU |
A rack unit that is equal to 48 mm (1.89 in). |
EIA_310 |
A rack unit that is equal to 1.75 in (44.45 mm). |
Slots[{item}].Location.Placement.Row Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The name of the row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Slots[{item}].PCIeType Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The PCIe specification supported by this slot. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Gen1 |
A PCIe v1.0 slot. |
Gen2 |
A PCIe v2.0 slot. |
Gen3 |
A PCIe v3.0 slot. |
Gen4 |
A PCIe v4.0 slot. |
Gen5 |
A PCIe v5.0 slot. |
Slots[{item}].SlotType Member of PCIeSlots.v1_3_0.PCIeSlots
Description | The PCIe slot type for this slot. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
FullLength |
Full-Length PCIe slot. |
HalfLength |
Half-Length PCIe slot. |
LowProfile |
Low-Profile or Slim PCIe slot. |
Mini |
Mini PCIe slot. |
M2 |
PCIe M.2 slot. |
OEM |
An OEM-specific slot. |
OCP3Small |
Open Compute Project 3.0 small form factor slot. |
OCP3Large |
Open Compute Project 3.0 large form factor slot. |
U2 |
PCIe U.2 slot or bay |
Slots[{item}].Status Member of PCIeSlots.v1_3_0.PCIeSlots See the Redfish standard schema and specification for information on common Status object.
Port
@odata.type: "#Port.v1_12_0.Port"
A Port represents a discrete physical port capable of connecting to a network.
The Data Source is either DCi or RDE. HPE OEM section shall be present only for DCi Data Source.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/networkadapters/{item}/ports/{item} |
GET POST PATCH |
/redfish/v1/chassis/{item}/networkadapters/{item}/ports/{item}/settings |
GET PATCH |
/redfish/v1/fabrics/{item}/switches/{item}/Ports/{item} |
GET POST |
/redfish/v1/managers/{item}/dedicatednetworkports/{item} |
GET PATCH |
/redfish/v1/managers/{item}/sharednetworkports/{item} |
GET PATCH |
/redfish/v1/systems/{item}/networkinterfaces/{item}/ports/{item} |
GET POST PATCH |
/redfish/v1/systems/{item}/networkinterfaces/{item}/ports/{item}/settings |
GET PATCH |
/redfish/v1/systems/{item}/storage/{item}/controllers/{item}/ports/{item} |
GET PATCH |
/redfish/v1/systems/{item}/storage/{item}/storagecontrollers/{item}/ports/{item} |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
settings |
Port |
@Redfish.Settings
Member of Port.v1_12_0.Port See the Redfish standard schema and specification for information on common @Redfish properties.
ActiveWidth
Member of Port.v1_12_0.Port
Description | The number of active lanes for this interface. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
CapableProtocolVersions (array)
Member of Port.v1_12_0.Port
CapableProtocolVersions
is an array containing elements of:
CapableProtocolVersions[{item}] Member of Port.v1_12_0.Port
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
CurrentProtocolVersion
Member of Port.v1_12_0.Port
Description | The protocol version being sent over this port. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
CurrentSpeedGbps
Member of Port.v1_12_0.Port
Description | The current speed of this port. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Enabled
Member of Port.v1_12_0.Port
Description | An indication of whether this port is enabled. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Ethernet
Ethernet.AssociatedMACAddresses (array) Member of Port.v1_12_0.Port
AssociatedMACAddresses
is an array containing elements of:
AssociatedMACAddresses[{item}] Member of Port.v1_12_0.Port
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Ethernet.EEEEnabled Member of Port.v1_12_0.Port
Description | Indicates whether IEEE 802.3az Energy-Efficient Ethernet (EEE) is enabled on this port. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.FlowControlConfiguration Member of Port.v1_12_0.Port
Description | The locally configured 802.3x flow control setting for this port. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
None |
No IEEE 802.3x flow control is enabled on this port. |
TX |
IEEE 802.3x flow control may be initiated by this station. |
RX |
IEEE 802.3x flow control may be initiated by the link partner. |
TX_RX |
IEEE 802.3x flow control may be initiated by this station or the link partner. |
Ethernet.FlowControlStatus Member of Port.v1_12_0.Port
Description | The 802.3x flow control behavior negotiated with the link partner for this port. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
None |
No IEEE 802.3x flow control is enabled on this port. |
TX |
IEEE 802.3x flow control may be initiated by this station. |
RX |
IEEE 802.3x flow control may be initiated by the link partner. |
TX_RX |
IEEE 802.3x flow control may be initiated by this station or the link partner. |
Ethernet.LLDPEnabled Member of Port.v1_12_0.Port
Description | Enable/disable LLDP for this port. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.LLDPReceive Ethernet.LLDPReceive.ChassisId Member of Port.v1_12_0.Port
Description | Link Layer Data Protocol (LLDP) chassis ID received from the remote partner across this link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Ethernet.LLDPReceive.ChassisIdSubtype Member of Port.v1_12_0.Port
Description | The type of identifier used for the chassis ID received from the remote partner across this link. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ChassisComp |
Chassis component, based in the value of entPhysicalAlias in RFC4133. |
IfAlias |
Interface alias, based on the ifAlias MIB object. |
PortComp |
Port component, based in the value of entPhysicalAlias in RFC4133. |
MacAddr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
NetworkAddr |
Network address, based on an agent detected network address. |
IfName |
Interface name, based on the ifName MIB object. |
AgentId |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC3046. |
LocalAssign |
Locally assigned, based on a alpha-numeric value locally assigned. |
NotTransmitted |
No data to be sent to/received from remote partner. |
Ethernet.LLDPReceive.ManagementAddressIPv4 Member of Port.v1_12_0.Port
Description | The IPv4 management address received from the remote partner across this link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Ethernet.LLDPReceive.ManagementAddressIPv6 Member of Port.v1_12_0.Port
Description | The IPv6 management address received from the remote partner across this link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Ethernet.LLDPReceive.ManagementAddressMAC Member of Port.v1_12_0.Port
Description | The management MAC address received from the remote partner across this link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Ethernet.LLDPReceive.ManagementVlanId Member of Port.v1_12_0.Port
Description | The management VLAN ID received from the remote partner across this link. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Ethernet.LLDPReceive.PortId Member of Port.v1_12_0.Port
Description | A colon delimited string of hexadecimal octets identifying a port. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Ethernet.LLDPReceive.PortIdSubtype Member of Port.v1_12_0.Port
Description | The port ID subtype received from the remote partner across this link. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ChassisComp |
Chassis component, based in the value of entPhysicalAlias in RFC4133. |
IfAlias |
Interface alias, based on the ifAlias MIB object. |
PortComp |
Port component, based in the value of entPhysicalAlias in RFC4133. |
MacAddr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
NetworkAddr |
Network address, based on an agent detected network address. |
IfName |
Interface name, based on the ifName MIB object. |
AgentId |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC3046. |
LocalAssign |
Locally assigned, based on a alpha-numeric value locally assigned. |
NotTransmitted |
No data to be sent to/received from remote partner. |
Ethernet.LLDPReceive.SystemCapabilities (array) Member of Port.v1_12_0.Port
SystemCapabilities
is an array containing elements of:
SystemCapabilities[{item}] Member of Port.v1_12_0.Port
Type | string |
Read Only | True |
Added | iLO6 1.63 |
The following are the supported values:
Value |
---|
None |
Bridge |
DOCSISCableDevice |
Other |
Repeater |
Router |
Station |
Telephone |
WLANAccessPoint |
Ethernet.LLDPReceive.SystemDescription Member of Port.v1_12_0.Port
Description | The system description received from the remote partner across this link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.63 |
Ethernet.LLDPReceive.SystemName Member of Port.v1_12_0.Port
Description | The system name received from the remote partner across this link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.63 |
Ethernet.LLDPTransmit Ethernet.LLDPTransmit.ChassisId Member of Port.v1_12_0.Port
Description | Link Layer Data Protocol (LLDP) chassis ID. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.LLDPTransmit.ChassisIdSubtype Member of Port.v1_12_0.Port
Description | The type of identifier used for the chassis ID. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ChassisComp |
Chassis component, based in the value of entPhysicalAlias in RFC4133. |
IfAlias |
Interface alias, based on the ifAlias MIB object. |
PortComp |
Port component, based in the value of entPhysicalAlias in RFC4133. |
MacAddr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
NetworkAddr |
Network address, based on an agent detected network address. |
IfName |
Interface name, based on the ifName MIB object. |
AgentId |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC3046. |
LocalAssign |
Locally assigned, based on a alpha-numeric value locally assigned. |
NotTransmitted |
No data to be sent to/received from remote partner. |
Ethernet.LLDPTransmit.ManagementAddressIPv4 Member of Port.v1_12_0.Port
Description | The IPv4 management address to be transmitted from this endpoint. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.LLDPTransmit.ManagementAddressIPv6 Member of Port.v1_12_0.Port
Description | The IPv6 management address to be transmitted from this endpoint. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.LLDPTransmit.ManagementAddressMAC Member of Port.v1_12_0.Port
Description | The management MAC address to be transmitted from this endpoint. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.LLDPTransmit.ManagementVlanId Member of Port.v1_12_0.Port
Description | The management VLAN ID to be transmitted from this endpoint. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.LLDPTransmit.PortId Member of Port.v1_12_0.Port
Description | A colon delimited string of hexadecimal octets identifying a port to be transmitted from this endpoint. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Ethernet.LLDPTransmit.PortIdSubtype Member of Port.v1_12_0.Port
Description | The port ID subtype to be transmitted from this endpoint. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ChassisComp |
Chassis component, based in the value of entPhysicalAlias in RFC4133. |
IfAlias |
Interface alias, based on the ifAlias MIB object. |
PortComp |
Port component, based in the value of entPhysicalAlias in RFC4133. |
MacAddr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
NetworkAddr |
Network address, based on an agent detected network address. |
IfName |
Interface name, based on the ifName MIB object. |
AgentId |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC3046. |
LocalAssign |
Locally assigned, based on a alpha-numeric value locally assigned. |
NotTransmitted |
No data to be sent to/received from remote partner. |
Ethernet.LLDPTransmit.SystemCapabilities (array) Member of Port.v1_12_0.Port
SystemCapabilities
is an array containing elements of:
SystemCapabilities[{item}] Member of Port.v1_12_0.Port
Type | string |
Read Only | True |
Added | iLO6 1.63 |
The following are the supported values:
Value |
---|
None |
Bridge |
DOCSISCableDevice |
Other |
Repeater |
Router |
Station |
Telephone |
WLANAccessPoint |
Ethernet.LLDPTransmit.SystemDescription Member of Port.v1_12_0.Port
Description | The system description to be transmitted from this endpoint. |
Type | string or null |
Read Only | False |
Added | iLO6 1.63 |
Ethernet.LLDPTransmit.SystemName Member of Port.v1_12_0.Port
Description | The system name to be transmitted from this endpoint. |
Type | string or null |
Read Only | False |
Added | iLO6 1.63 |
Ethernet.WakeOnLANEnabled Member of Port.v1_12_0.Port
Description | Indicates whether Wake on LAN (WoL) is enabled on this port. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
FibreChannel
FibreChannel.AssociatedWorldWideNames (array) Member of Port.v1_12_0.Port
AssociatedWorldWideNames
is an array containing elements of:
AssociatedWorldWideNames[{item}] Member of Port.v1_12_0.Port
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
FibreChannel.FabricName Member of Port.v1_12_0.Port
Description | The Fibre Channel Fabric Name provided by the switch. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
FibreChannel.NumberDiscoveredRemotePorts Member of Port.v1_12_0.Port
Description | The number of ports not on the associated device that the associated device has discovered through this port. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
FibreChannel.PortConnectionType Member of Port.v1_12_0.Port
Description | The connection type of this port. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NotConnected |
This port is not connected. |
NPort |
This port connects through an N-Port to a switch. |
PointToPoint |
This port connects in a Point-to-point configuration. |
PrivateLoop |
This port connects in a private loop configuration. |
PublicLoop |
This port connects in a public configuration. |
Generic |
This port connection type is a generic fabric port. |
ExtenderFabric |
This port connection type is an extender fabric port. |
FPort |
This port connection type is a fabric port. |
EPort |
This port connection type is an extender fabric port. |
TEPort |
This port connection type is an trunking extender fabric port. |
NPPort |
This port connection type is a proxy N port for N-Port virtualization. |
GPort |
This port connection type is a generic fabric port. |
NLPort |
This port connects in a node loop configuration. |
FLPort |
This port connects in a fabric loop configuration. |
EXPort |
This port connection type is an external fabric port. |
UPort |
This port connection type is unassigned. |
DPort |
This port connection type is a diagnostic port. |
FunctionMaxBandwidth (array)
Member of Port.v1_12_0.Port
FunctionMaxBandwidth
is an array containing elements of:
FunctionMaxBandwidth[{item}].AllocationPercent Member of Port.v1_12_0.Port
Description | The maximum bandwidth allocation percentage allocated to the corresponding network device function instance. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
FunctionMaxBandwidth[{item}].NetworkDeviceFunction
The link to the network device function associated with this bandwidth setting of this network port.
NetworkDeviceFunction is a link ("@odata.id": URI
) to another resource.
FunctionMinBandwidth (array)
Member of Port.v1_12_0.Port
FunctionMinBandwidth
is an array containing elements of:
FunctionMinBandwidth[{item}].AllocationPercent Member of Port.v1_12_0.Port
Description | The minimum bandwidth allocation percentage allocated to the corresponding network device function instance. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
FunctionMinBandwidth[{item}].NetworkDeviceFunction
The link to the network device function associated with this bandwidth setting of this network port.
NetworkDeviceFunction is a link ("@odata.id": URI
) to another resource.
InterfaceEnabled
Member of Port.v1_12_0.Port
Description | An indication of whether the interface is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
LinkConfiguration (array)
Member of Port.v1_12_0.Port
LinkConfiguration
is an array containing elements of:
LinkConfiguration[{item}].AutoSpeedNegotiationCapable Member of Port.v1_12_0.Port
Description | An indication of whether the port is capable of autonegotiating speed. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
LinkConfiguration[{item}].AutoSpeedNegotiationEnabled Member of Port.v1_12_0.Port
Description | Controls whether this port is configured to enable autonegotiating speed. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
LinkConfiguration[{item}].CapableLinkSpeedGbps (array) Member of Port.v1_12_0.Port
CapableLinkSpeedGbps
is an array containing elements of:
CapableLinkSpeedGbps[{item}] Member of Port.v1_12_0.Port
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
LinkConfiguration[{item}].ConfiguredNetworkLinks (array) Member of Port.v1_12_0.Port
ConfiguredNetworkLinks
is an array containing elements of:
ConfiguredNetworkLinks[{item}].ConfiguredLinkSpeedGbps Member of Port.v1_12_0.Port
Description | The link speed per lane this port is configured to use for autonegotiation. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
ConfiguredNetworkLinks[{item}].ConfiguredWidth Member of Port.v1_12_0.Port
Description | The link width this port is configured to use for autonegotiation in conjunction with the link speed. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
LinkNetworkTechnology
Member of Port.v1_12_0.Port
Description | The link network technology capabilities of this port. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Ethernet |
The port is capable of connecting to an Ethernet network. |
InfiniBand |
The port is capable of connecting to an InfiniBand network. |
FibreChannel |
The port is capable of connecting to a Fibre Channel network. |
GenZ |
The port is capable of connecting to a Gen-Z fabric. |
LinkState
Member of Port.v1_12_0.Port
Description | The desired link state for this interface. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
This link is enabled. |
Disabled |
This link is disabled. |
LinkStatus
Member of Port.v1_12_0.Port
Description | The desired link status for this interface. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
LinkUp |
This link on this interface is up. |
Starting |
This link on this interface is starting. A physical link has been established, but the port is not able to transfer data. |
Training |
This physical link on this interface is training. |
LinkDown |
The link on this interface is down. |
NoLink |
No physical link detected on this interface. |
LinkTransitionIndicator
Member of Port.v1_12_0.Port
Description | The number of link state transitions for this interface. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Location
Location.PartLocation Location.PartLocation.LocationOrdinalValue Member of Port.v1_12_0.Port
Description | The number that represents the location of the part. If LocationType is slot and this unit is in slot 2, the LocationOrdinalValue is 2. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Location.PartLocation.LocationType Member of Port.v1_12_0.Port
Description | The location types for PartLocation. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Slot |
The slot as the type of location. |
Bay |
The bay as the type of location. |
Connector |
The connector as the type of location. |
Socket |
The socket as the type of location. |
Embedded |
Embedded within a part. |
Location.PartLocation.Orientation Member of Port.v1_12_0.Port
Description | The orientation for the ordering of the part location ordinal value. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
FrontToBack |
The ordering for LocationOrdinalValue is front to back. |
BackToFront |
The ordering for the LocationOrdinalValue is back to front. |
TopToBottom |
The ordering for the LocationOrdinalValue is top to bottom. |
BottomToTop |
The ordering for LocationOrdinalValue is bottom to top. |
LeftToRight |
The ordering for the LocationOrdinalValue is left to right. |
RightToLeft |
The ordering for the LocationOrdinalValue is right to left. |
Location.PartLocation.Reference Member of Port.v1_12_0.Port
Description | The reference area for the location of the part. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Top |
The part is in the top of the unit. |
Bottom |
The part is in the bottom of the unit. |
Front |
The part is in the front of the unit. |
Rear |
The part is in the rear of the unit. |
Left |
The part is on the left side of of the unit. |
Right |
The part is on the right side of the unit. |
Middle |
The part is in the middle of the unit. |
Location.PartLocation.ServiceLabel Member of Port.v1_12_0.Port
Description | The label of the part location, such as a silk-screened name or a printed label. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Location.Placement Location.Placement.AdditionalInfo Member of Port.v1_12_0.Port
Description | Area designation or other additional info. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Location.Placement.Rack Member of Port.v1_12_0.Port
Description | The name of a rack location within a row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Location.Placement.RackOffset Member of Port.v1_12_0.Port
Description | The vertical location of the item, in terms of RackOffsetUnits. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Location.Placement.RackOffsetUnits Member of Port.v1_12_0.Port
Description | The type of rack unit in use. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OpenU |
A rack unit that is equal to 48 mm (1.89 in). |
EIA_310 |
A rack unit that is equal to 1.75 in (44.45 mm). |
Location.Placement.Row Member of Port.v1_12_0.Port
Description | The name of the row. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
LocationIndicatorActive
Member of Port.v1_12_0.Port
Description | An indicator allowing an operator to physically locate this resource. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
MaxFrameSize
Member of Port.v1_12_0.Port
Description | The maximum frame size supported by the port. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MaxSpeedGbps
Member of Port.v1_12_0.Port
Description | The maximum speed of this port as currently configured. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.AutoNegotiationCapable
Member of Port.v1_12_0.Port
Description | Indicates the ability of this network port to autonegotiate link speed. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ConfiguredNetworkLinks (array)
Member of Port.v1_12_0.Port
ConfiguredNetworkLinks
is an array containing elements of:
ConfiguredNetworkLinks[{item}].ConfiguredLinkSpeedGbps Member of Port.v1_12_0.Port
Description | The link speed per lane this port is configured to use for autonegotiation. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
ConfiguredNetworkLinks[{item}].ConfiguredWidth Member of Port.v1_12_0.Port
Description | The number of lanes this port is configured to use for autonegotiation. If this property is omitted, the lane count shall default to one. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.EvbData
Oem.Hpe.EvbData.Receiving Oem.Hpe.EvbData.Receiving.CdcpActive Member of Port.v1_12_0.Port
Description | True if a currently active IEEE 802.1Qbg CDCP TLV has been received from the link partner. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.ChannelActive Member of Port.v1_12_0.Port
Description | A currently unexpired HPE Channel Link Control or HPE Channel Description TLV has been received from the link partner. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.ChannelDescriptionLocalSequenceNumber Member of Port.v1_12_0.Port
Description | The link partner's HPE Channel Description sequence number that was last successfully received and processed. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.ChannelDescriptionRemoteSequenceNumber Member of Port.v1_12_0.Port
Description | The last HPE Channel Decsription sequence number sent on this link that was successfully received and processed by the link partner. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.ChannelDescriptionSubtype Member of Port.v1_12_0.Port
Description | The header subtype field of the last received HPE Channel Description TLV. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.ChannelLinkControlLocalSequenceNumber Member of Port.v1_12_0.Port
Description | The link partner's HPE Channel Link Control sequence number that was last successfully received and processed. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.ChannelLinkControlMCEnable Member of Port.v1_12_0.Port
Description | The Feature Indicators field, Management Controller (MC) Channel (SCID 4094) enabled state in the HPE CLC TLV being received from the link partner on this port. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.ChannelLinkControlRemoteSequenceNumber Member of Port.v1_12_0.Port
Description | The last HPE Channel Link control sequence number sent on this link that was successfully received and processed by the link partner. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.ChannelLinkControlSubtype Member of Port.v1_12_0.Port
Description | The header subtype field of the last received HPE Channel Link Control TLV. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.Role Member of Port.v1_12_0.Port
Description | The link partner's IEEE 802.1Qbg operating role. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
bridge |
Indicates the link partner is operating as a Bridge. |
station |
Indicates the link partner is operating as a Station. |
Oem.Hpe.EvbData.Receiving.SChannelAssignments (array) Member of Port.v1_12_0.Port
SChannelAssignments
is an array containing elements of:
SChannelAssignments[{item}].Scid Member of Port.v1_12_0.Port
Description | SCID value for this <SCID,SVID> S-Channel identifier pairreceived from the link partner on this port. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
SChannelAssignments[{item}].Svid Member of Port.v1_12_0.Port
Description | SVID assignment value for this <SCID,SVID> S-Channel identifier pair received from the link partner on this port. When 0 it indicates an assignment request is in progress. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.SChannelMaxCount Member of Port.v1_12_0.Port
Description | Indicates the number of S-Channels the link partner can support on this physical link. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.SChannelsSupported Member of Port.v1_12_0.Port
Description | When true this link supports S-Channels. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Receiving.VirtualLinkStatusVector Member of Port.v1_12_0.Port
Description | A bit vector indicating S-Channel status received from the link partner, 1=up, 0=down. S-Channel status bits are ordered by SCID from lowest numbered (first) to highest (last). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting Oem.Hpe.EvbData.Transmitting.ChannelDescriptionData (array) Member of Port.v1_12_0.Port
ChannelDescriptionData
is an array containing elements of:
ChannelDescriptionData[{item}].Descriptor0BandwidthCirMbps Member of Port.v1_12_0.Port
Description | The bandwidth Commited Information Rate (CIR) for this S-Channel, in Mbps. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor0BandwidthPirMbps Member of Port.v1_12_0.Port
Description | The bandwidth Peak Information Rate (PIR) for this S-Channel, in Mbps. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor0ChannelTerminationType Member of Port.v1_12_0.Port
Description | Indicates the termination provided for this S-Channel. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
primary-physical |
This S-Channel is presented to the host OS as a primary PCI physical function. |
SR-IOV-virtual |
This S-Channel is presented to the host OS as a PCI SR-IOV virtual function. |
secondary-physical |
This S-Channel is presented to the host OS as a secondary PCI physical function, i.e. a PCI physical function behind a bridge on the device. |
vSwitch-port |
This S-Channel is mapped to a Virtual Switch port. |
NCSI-port |
This S-Channel is mapped to the NCSI internal port for management. |
ChannelDescriptionData[{item}].Descriptor0EthernetSupport Member of Port.v1_12_0.Port
Description | When true, this S-Channel supports Ethernet. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor0FCoESupport Member of Port.v1_12_0.Port
Description | When true, this S-Channel supports Fibre Channel over Ethernet (FCoE). |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor0PcpSupport Member of Port.v1_12_0.Port
Description | Indicates which IEEE 802.1Q Ethernet Priority Code Point (PCP) classes are supported on this S-Channel. When no PCPs are supported, the S-Channel makes no attempt to filter or control traffic class. A string of 1/0 characters indicating 1=enabled, 0=disabled. PCP classes are ordered from highest numbered 7 (first) to lowest 0 (last). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor0RoCEESupport Member of Port.v1_12_0.Port
Description | When true, this S-Channel supports RDMA over Converged Enhanced Ethernet (RoCEE). |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor0Scid Member of Port.v1_12_0.Port
Description | The S-Channel identifier for this Descriptor0 instance. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor0iSCSISupport Member of Port.v1_12_0.Port
Description | When true, this S-Channel supports Internet SCSI (iSCSI). |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor1ConnectionID Member of Port.v1_12_0.Port
Description | A unique S-Channel identifer in UUID format. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ChannelDescriptionData[{item}].Descriptor1Scid Member of Port.v1_12_0.Port
Description | The S-Channel identifier for this Descriptor1 instance. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.ChannelDescriptionLocalSequenceNumber Member of Port.v1_12_0.Port
Description | This station's channel discovery local sequence number which will be transmitted to the link partner on this port. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.ChannelDescriptionRemoteSequenceNumber Member of Port.v1_12_0.Port
Description | The link partner's channel discovery local sequence number that was last successfully received and processed. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.ChannelDescriptorCount Member of Port.v1_12_0.Port
Description | The number of channel descriptor pairs being transmitted to the link partner on this port. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.ChannelLinkControlLocalSequenceNumber Member of Port.v1_12_0.Port
Description | This station's channel link control local sequence number which will be transmitted to the link partner on this port. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.ChannelLinkControlMCEnable Member of Port.v1_12_0.Port
Description | The Feature Indicators field, Management Controller (MC) Channel (SCID 4094) enabled state in the HPE CLC TLV being transmitted to the link partner on this port. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.ChannelLinkControlRemoteSequenceNumber Member of Port.v1_12_0.Port
Description | The link partner's channel link control local sequence number that was last successfully received and processed. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.Role Member of Port.v1_12_0.Port
Description | This port's IEEE 802.1Qbg role being advertised on the link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
bridge |
Indicates this link is operating locally as a Bridge. |
station |
Indicates this link is operating locally as a Station. |
Oem.Hpe.EvbData.Transmitting.SChannelAssignments (array) Member of Port.v1_12_0.Port
SChannelAssignments
is an array containing elements of:
SChannelAssignments[{item}].Scid Member of Port.v1_12_0.Port
Description | SCID value for this <SCID,SVID> S-Channel identifier pair being transmitted to the link partner on this port. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
SChannelAssignments[{item}].Svid Member of Port.v1_12_0.Port
Description | SVID assignment value for this <SCID,SVID> S-Channel identifier pair being transmitted to the link partner on this port. When 0 it indicates an SVID assignment request to the link partner is in progress. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.SChannelMaxCount Member of Port.v1_12_0.Port
Description | The Channel Capacity value being advertised to the link partner. It indicates the number of S-Channels this station can support on this physical link. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.SChannelsSupported Member of Port.v1_12_0.Port
Description | When true, indicates that this physical link has S-Channel capability. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.EvbData.Transmitting.VirtualLinkStatusVector Member of Port.v1_12_0.Port
Description | A bit vector indicating S-Channel status being transmitted on this link, 1=up, 0=down. S-Channel status bits are ordered by SCID from lowest numbered (first) to highest (last). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData
Oem.Hpe.LldpData.Receiving Oem.Hpe.LldpData.Receiving.ChassisID Member of Port.v1_12_0.Port
Description | The LLDP chassis ID received from the link partner. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.ChassisIDSubtype Member of Port.v1_12_0.Port
Description | The IEEE 802.1AB-2009 chassis ID subtype received from the link partner. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
ChassisComp |
Chassis component, based in the value of entPhysicalAlias in IETF RFC 4133. |
IfAlias |
Interface alias, based on the IfAlias MIB object. |
PortComp |
Port component, based in the value of entPhysicalAlias in IETF RFC 4133. |
MacAddr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
NetworkAddr |
Network address, based on an agent detected network address. |
IfName |
Interface name, based on the IfName MIB object. |
AgentId |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC 3046. |
LocalAssign |
Locally assigned, based on a alpha-numeric value locally assigned. |
Oem.Hpe.LldpData.Receiving.Dcb Oem.Hpe.LldpData.Receiving.Dcb.ApplicationPriorityReceived Member of Port.v1_12_0.Port
Description | True when an unexpired Data Center Bridging (DCB) Application Priority Table TLV has been received. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.ApplicationPriorityTable (array) Member of Port.v1_12_0.Port
ApplicationPriorityTable
is an array containing elements of:
ApplicationPriorityTable[{item}].ApplicationPriority Member of Port.v1_12_0.Port
Description | Indicates which priority level is assigned for this application protocol. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
ApplicationPriorityTable[{item}].ApplicationProtocol Member of Port.v1_12_0.Port
Description | An integer value indicating application protocol identity, of the type described by DCBApplicationSelect. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
ApplicationPriorityTable[{item}].ApplicationSelect Member of Port.v1_12_0.Port
Description | Indentifies the type of the DCBApplicationProtocol property. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
reserved |
Reserved select value. |
default-Ethertype |
Default priority. Use when priority not otherwise specified. |
TCP-SCTP |
DCBApplicationProtocol value is a well known port over TCP or SCTP. |
UDP-DCCP |
DCBApplicationProtocol value is a well known port over UDP or DCCP. |
TCP-SCTP-UDP-DCCP |
DCBApplicationProtocol is a well known port over TCP, SCTP, SCTP, or DCCP. |
Oem.Hpe.LldpData.Receiving.Dcb.Ets Oem.Hpe.LldpData.Receiving.Dcb.Ets.BandwidthAssignmentTable (array) Member of Port.v1_12_0.Port
BandwidthAssignmentTable
is an array containing elements of:
BandwidthAssignmentTable[{item}] Member of Port.v1_12_0.Port
Description | One entry in the DCB ETS Traffic Class (TC) Bandwidth Assignment Table. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Ets.CreditBasedShaper Member of Port.v1_12_0.Port
Description | True if the link partner supports the Credit-based Shaper (CBS) transmmission selection algortithm. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Ets.MaximumTrafficClassCount Member of Port.v1_12_0.Port
Description | The maximum number of traffic classes supported by the link partner. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Ets.PriorityAssignmentTable (array) Member of Port.v1_12_0.Port
PriorityAssignmentTable
is an array containing elements of:
PriorityAssignmentTable[{item}] Member of Port.v1_12_0.Port
Description | One entry in the DCB ETS Priority Assignment Table indicating this priority's Traffic Class assignment. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Ets.TlvReceived Member of Port.v1_12_0.Port
Description | True when an unexpired DCB Enhanced Transmission Selection (ETS) TLV has been received. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Ets.TrafficSelectionAlgorithmTable (array) Member of Port.v1_12_0.Port
TrafficSelectionAlgorithmTable
is an array containing elements of:
TrafficSelectionAlgorithmTable[{item}] Member of Port.v1_12_0.Port
Description | An assignment of a Traffic Selection Algorithm (TSA) to a traffic class. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
strict |
Strict priority algorithm. |
CBS |
Credit-Based Shaper algorithm. |
ETS |
Enhanced Traffic Selection algorithm. |
vendor |
Vendor specific algorithm for use with DCB. |
Oem.Hpe.LldpData.Receiving.Dcb.Ets.Willing Member of Port.v1_12_0.Port
Description | True if the link partner is willing to accept ETS configurations. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.LocalEqualRemote Member of Port.v1_12_0.Port
Description | True when the transmitted and received contents match for both DCB ETS and PFC TLVs. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Pfc Oem.Hpe.LldpData.Receiving.Dcb.Pfc.EnabledTrafficClasses Member of Port.v1_12_0.Port
Description | A bit string indicating which priority levels have PFC enabled, 1=enabled. PFC levels are bit ordered from 7 (first) to 0 (last). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Pfc.MacSecurityBypassCapability Member of Port.v1_12_0.Port
Description | True when the link partner has the ability to bypass MAC security in order to improve PFC responsiveness. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Pfc.MaximumTrafficClassCount Member of Port.v1_12_0.Port
Description | Indicates the maximum number of traffic classes that the link partner can simultaneously support. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Pfc.TlvReceived Member of Port.v1_12_0.Port
Description | True when an unexpired DCB Priority Flow Control (PFC) TLV has been received. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Pfc.Willing Member of Port.v1_12_0.Port
Description | True if the LLDP link partner is willing to accept PFC configurations. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.Dcb.Version Member of Port.v1_12_0.Port
Description | The DCB version supported by the link partner. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
unknown |
Unknown |
CEE |
Converged Enhanced Ethernet |
IEEE |
IEEE 802.1Q |
Oem.Hpe.LldpData.Receiving.ManagementAddress Member of Port.v1_12_0.Port
Description | The management address received from the link partner. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.ManagementAddressOID Member of Port.v1_12_0.Port
Description | An object identifier for the hardware or protocol entity associated with the management address. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.ManagementAddressReceived Member of Port.v1_12_0.Port
Description | True when a currently unexpired management address TLV has been received from the link partner. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.ManagementAddressType Member of Port.v1_12_0.Port
Description | The type of management address received from the link partner. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
IPv4 |
Type 1 (IP version 4). |
IPv6 |
Type 2 (IP version 6). |
all802 |
Type 6 (All 802 media plus Ethernet 'canonical format'). |
Oem.Hpe.LldpData.Receiving.ManagementIFNumSubtype Member of Port.v1_12_0.Port
Description | Management interface number subtype. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
unknown |
Interface number is not known. |
ifIndex |
Interface number is based on the ifIndex MIB object. |
sysPortNum |
Interface number is based on the system port numbering convention. |
Oem.Hpe.LldpData.Receiving.ManagementIFNumber Member of Port.v1_12_0.Port
Description | Management interface number received from the link partner represented as a colon delimited string of hexadecimal octets. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.ManagementVlanReceived Member of Port.v1_12_0.Port
Description | True when a currently unexpired management address VID TLV has been received from the link partner. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.NearestBridgeTtlExpired Member of Port.v1_12_0.Port
Description | True when the LLDP PDU most recently received from the link partner has expired. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.PortDescription Member of Port.v1_12_0.Port
Description | The remote link partner's port description. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.PortID Member of Port.v1_12_0.Port
Description | A colon delimited string of hexadecimal octets received from the link partner identifying its port. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Receiving.PortIDSubtype Member of Port.v1_12_0.Port
Description | The port ID subtype enumeration from IEEE 802.1AB-2009 Table 8-3, which indicates the format for the PortID property. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
ChassisComp |
Chassis component, based in the value of entPhysicalAlias in IETF RFC 4133. |
IfAlias |
Interface alias, based on the IfAlias MIB object. |
PortComp |
Port component, based in the value of entPhysicalAlias in IETF RFC 4133. |
MacAddr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
NetworkAddr |
Network address, based on an agent detected network address. |
IfName |
Interface name, based on the IfName MIB object. |
AgentId |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC 3046. |
LocalAssign |
Locally assigned, based on a alpha-numeric value locally assigned. |
Oem.Hpe.LldpData.Receiving.SystemDescription Member of Port.v1_12_0.Port
Description | The system description received from the link partner. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Transmitting Oem.Hpe.LldpData.Transmitting.ChassisID Member of Port.v1_12_0.Port
Description | The Link Layer Data Protocol (LLDP) chassis ID being transmitted on this link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Transmitting.ChassisIDSubtype Member of Port.v1_12_0.Port
Description | The IEEE 802.1AB-2009 chassis ID subtype being transmitted on this link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
ChassisComp |
Chassis component, based in the value of entPhysicalAlias in IETF RFC 4133. |
IfAlias |
Interface alias, based on the IfAlias MIB object. |
PortComp |
Port component, based in the value of entPhysicalAlias in IETF RFC 4133. |
MacAddr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
NetworkAddr |
Network address, based on an agent detected network address. |
IfName |
Interface name, based on the IfName MIB object. |
AgentId |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC 3046. |
LocalAssign |
Locally assigned, based on a alpha-numeric value locally assigned. |
Oem.Hpe.LldpData.Transmitting.ManagementAddresses (array) Member of Port.v1_12_0.Port
ManagementAddresses
is an array containing elements of:
ManagementAddresses[{item}].ManagementIPAddress Member of Port.v1_12_0.Port
Description | A management address. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ManagementAddresses[{item}].ManagementIPAddressType Member of Port.v1_12_0.Port
Description | The IANA type of this management address. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
IPv4 |
Type 1 (IP version 4). |
IPv6 |
Type 2 (IP version 6). |
all802 |
Type 6 (All 802 media plus Ethernet 'canonical format'). |
Oem.Hpe.LldpData.Transmitting.ManagementCvlanIDTransmitted Member of Port.v1_12_0.Port
Description | When true, indicates that a management CVLAN ID is being transmitted on this link. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Transmitting.PortDescription Member of Port.v1_12_0.Port
Description | An alphanumeric string describing this link. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Transmitting.PortID Member of Port.v1_12_0.Port
Description | A colon delimited string of hexadecimal octets identifying this port. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.LldpData.Transmitting.PortIDSubtype Member of Port.v1_12_0.Port
Description | The port ID subtype from IEEE 802.1AB-2009 Table 8-3. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
ChassisComp |
Chassis component, based in the value of entPhysicalAlias in IETF RFC 4133. |
IfAlias |
Interface alias, based on the IfAlias MIB object. |
PortComp |
Port component, based in the value of entPhysicalAlias in IETF RFC 4133. |
MacAddr |
MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802. |
NetworkAddr |
Network address, based on an agent detected network address. |
IfName |
Interface name, based on the IfName MIB object. |
AgentId |
Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC 3046. |
LocalAssign |
Locally assigned, based on a alpha-numeric value locally assigned. |
Oem.Hpe.LldpData.Transmitting.SystemDescription Member of Port.v1_12_0.Port
Description | A textual description of this system. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PortDiagnosticEnableLocalLoopback
Member of Port.v1_12_0.Port
Description | When true, local loopback is active on this port. PortDiagnosticsEnabled must first be true in order to set this property to true. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.PortDiagnosticEnableRemoteLoopback
Member of Port.v1_12_0.Port
Description | When true, remote loopback is active on this port. PortDiagnosticsEnabled must first be true in order to set this property to true. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.PortDiagnosticLocalLoopbackCapable
Member of Port.v1_12_0.Port
Description | When true, the port has local loopback capability. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PortDiagnosticRemoteLoopbackCapable
Member of Port.v1_12_0.Port
Description | When true, the port has remote loopback capability. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PortDiagnosticsEnabled
Member of Port.v1_12_0.Port
Description | When true, diagnostic features are enabled on this port. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.VirtualFunctionAllocations (array)
Member of Port.v1_12_0.Port
VirtualFunctionAllocations
is an array containing elements of:
VirtualFunctionAllocations[{item}].NetworkDeviceFunction
The logical network device function to which this virtual function allocation applies.
NetworkDeviceFunction is a link ("@odata.id": URI
) to another resource.
VirtualFunctionAllocations[{item}].VirtualFunctionsAllocated Member of Port.v1_12_0.Port
Description | The number of virtual functions allocated to this logical network device function instance. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
PortId
Member of Port.v1_12_0.Port
Description | The label of this port on the physical package for this port. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PortMedium
Member of Port.v1_12_0.Port
Description | The physical connection medium for this port. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Electrical |
This port has an electrical cable connection. |
Optical |
This port has an optical cable connection. |
PortProtocol
Member of Port.v1_12_0.Port
Description | The protocol being sent over this port. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Ethernet |
Ethernet. |
FC |
Fibre Channel. |
FCoE |
Fibre Channel over Ethernet (FCoE). |
GenZ |
GenZ. |
InfiniBand |
InfiniBand. |
SAS |
Serial Attached SCSI. |
MultiProtocol |
Multiple Protocols. |
PCIe |
PCI Express. |
AHCI |
Advanced Host Controller Interface (AHCI). |
UHCI |
Universal Host Controller Interface (UHCI). |
SATA |
Serial AT Attachment. |
USB |
Universal Serial Bus (USB). |
NVMe |
Non-Volatile Memory Express (NVMe). |
iSCSI |
Internet SCSI. |
FCP |
Fibre Channel Protocol for SCSI. |
FICON |
FIbre CONnection (FICON). |
NVMeOverFabrics |
NVMe over Fabrics. |
SMB |
Server Message Block (SMB). Also known as the Common Internet File System (CIFS). |
NFSv3 |
Network File System (NFS) version 3. |
NFSv4 |
Network File System (NFS) version 4. |
HTTP |
Hypertext Transport Protocol (HTTP). |
HTTPS |
Hypertext Transfer Protocol Secure (HTTPS). |
FTP |
File Transfer Protocol (FTP). |
SFTP |
SSH File Transfer Protocol (SFTP). |
iWARP |
Internet Wide Area RDMA Protocol (iWARP). |
RoCE |
RDMA over Converged Ethernet Protocol. |
RoCEv2 |
RDMA over Converged Ethernet Protocol Version 2. |
I2C |
Inter-Integrated Circuit Bus. |
TCP |
Transmission Control Protocol (TCP). |
UDP |
User Datagram Protocol (UDP). |
TFTP |
Trivial File Transfer Protocol (TFTP). |
NVLink |
NVLink. |
OEM |
OEM-specific. |
DisplayPort |
DisplayPort. |
HDMI |
HDMI. |
VGA |
VGA. |
DVI |
DVI. |
PortType
Member of Port.v1_12_0.Port
Description | The type of this port. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
UpstreamPort |
This port connects to a host device. |
DownstreamPort |
This port connects to a target device. |
InterswitchPort |
This port connects to another switch. |
ManagementPort |
This port connects to a switch manager. |
BidirectionalPort |
This port connects to any type of device. |
UnconfiguredPort |
This port has not yet been configured. |
SignalDetected
Member of Port.v1_12_0.Port
Description | An indication of whether a signal is detected on this interface. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of Port.v1_12_0.Port See the Redfish standard schema and specification for information on common Status object.
Width
Member of Port.v1_12_0.Port
Description | The number of lanes, phys, or other physical transport links that this port contains. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Actions
Port.Reset Member of Port.v1_12_0.Port
Parameters:
target (string)
Link to invoke action
ResetValue (string)
Reset Port
Value | Description |
---|---|
GracefulRestart | Shut down gracefully and restart the system. |
GracefulShutdown | Shut down gracefully and power off. |
PowerCycle | Power cycle the unit. Behaves like a full power removal, followed by a power restore to the resource. |
On | Turn on the unit. |
ForceOff | Turn off the unit immediately (non-graceful shutdown). |
PushPowerButton | Simulate the pressing of the physical power button on this unit. |
ForceOn | Turn on the unit immediately. |
ForceRestart | Shut down immediately and non-gracefully and restart the system. |
Nmi | Generate a diagnostic interrupt, which is usually an NMI on x86 systems, to stop normal operations, complete diagnostic actions, and, typically, halt the system. |
PortCollection
@odata.type: "#PortCollection.PortCollection"
A Collection of Port resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/networkadapters/{item}/ports |
GET |
/redfish/v1/fabrics/{item}/switches/{item}/Ports |
GET |
/redfish/v1/managers/{item}/dedicatednetworkports |
GET |
/redfish/v1/managers/{item}/sharednetworkports |
GET |
/redfish/v1/systems/{item}/networkinterfaces/{item}/ports |
GET POST PATCH |
/redfish/v1/systems/{item}/storage/{item}/storagecontrollers/{item}/ports |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Port |
Members (array)
Member of PortCollection.PortCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of PortCollection.PortCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of PortCollection.PortCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Power
@odata.type: "#Power.v1_7_1.Power"
The Power resource describes the Power Metrics. It represents the properties for Power Consumption and Power Limiting.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/power |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Oem/Hpe/Links/FederatedGroupCapping |
HpeiLOFederatedGroupCapping |
Oem/Hpe/Links/PowerMeter |
HpePowerMeter |
Redundancy[]/RedundancySet[] |
Power |
Oem/Hpe/Links/FastPowerMeter |
HpePowerMeter |
Oem.Hpe.BatteryBackedUnits (array)
Member of Power.v1_7_1.Power
BatteryBackedUnits
is an array containing elements of:
BatteryBackedUnits[{item}].BBUStatus BatteryBackedUnits[{item}].BBUStatus.Health Member of Power.v1_7_1.Power
Description | This represents the health state of this resource in the absence of its dependent resources. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
BatteryBackedUnits[{item}].BBUStatus.HealthRollup Member of Power.v1_7_1.Power
Description | This represents the overall health state from the view of this resource. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
BatteryBackedUnits[{item}].BBUStatus.State Member of Power.v1_7_1.Power
Description | This indicates the known state of the resource, such as if it is enabled. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Enabled |
This function or resource has been enabled. |
Disabled |
This function or resource has been disabled. |
StandbyOffline |
This function or resource is enabled, but awaiting an external action to activate it. |
StandbySpare |
This function or resource is part of a redundancy set and is awaiting a failover or other external action to activate it. |
InTest |
This function or resource is undergoing testing. |
Starting |
This function or resource is starting. |
Absent |
This function or resource is not present or not detected. |
UnavailableOffline |
This function or resource is present but cannot be used. |
Deferring |
The element will not process any commands but will queue new requests. |
Quiesced |
The element is enabled but only processes a restricted set of commands. |
Updating |
The element is updating and may be unavailable or degraded. |
BatteryBackedUnits[{item}].BayNumber Member of Power.v1_7_1.Power
Description | Bay number of the battery backed unit. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].CapacityWatts Member of Power.v1_7_1.Power
Description | Total capacity (in Watts) of the battery backed unit. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].CutOffSetPointmAh Member of Power.v1_7_1.Power
Description | Cut off threshold (mAh) where battery backed unit stops supplying power to the server. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].FirmwareVersion Member of Power.v1_7_1.Power
Description | Firmware version of the battery backed unit. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].PercentCharge Member of Power.v1_7_1.Power
Description | Percentage charge remaining for the battery backed unit. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].RemainingCapacitymAh Member of Power.v1_7_1.Power
Description | Remaining capacity (mAh) of the battery backed unit. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].SerialNumber Member of Power.v1_7_1.Power
Description | Serial number of the battery backed unit. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].TimeToCutOffSeconds Member of Power.v1_7_1.Power
Description | Run time (in seconds) available with the battery backed unit until cut off. This is detected only when battery is charging or discharging, otherwise set to 0. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].TimeToFullChargeMinutes Member of Power.v1_7_1.Power
Description | Time required (in minutes) to fully charge the battery backed unit. This is detected only when battery is charging or discharging, otherwise set to 0. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
BatteryBackedUnits[{item}].UsableCapacitymAh Member of Power.v1_7_1.Power
Description | Usable capacity (mAh) of the battery backed unit. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.BbuPowerSupply
Member of Power.v1_7_1.Power
Description | Battery Backup Unit Power Supply action determines what will occur when a server is running on battery power. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
DoNothing |
No action will be taken when a server switches to battery power. |
MomentaryPowerButtonPress |
Momentary virtual power button press which should shutdown host operating system when pressed. |
HostShutdown |
Shutdown message sent to host operating system with installed management software to initiate a shutdown. |
Oem.Hpe.BrownoutRecoveryEnabled
Member of Power.v1_7_1.Power
Description | When a brownout condition occurs in the server, this setting will determine if the server should recover from it. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.Domains (array)
Member of Power.v1_7_1.Power
Domains
is an array containing elements of:
Domains[{item}].DomainName Member of Power.v1_7_1.Power
Description | Power Supply Domain Name. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value |
---|
System |
GPU |
GPU1 |
GPU2 |
Domains[{item}].HighEfficiencyMode Member of Power.v1_7_1.Power
Description | The redundant power supply mode that will be used when redundant power supplies are configured. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value |
---|
Null |
Auto |
Balanced |
Even |
Odd |
NoSupport |
Domains[{item}].PowerSupplies (array) Member of Power.v1_7_1.Power
PowerSupplies
is an array containing elements of:
PowerSupplies[{item}].@odata.id Member of Power.v1_7_1.Power
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Domains[{item}].PowerSupplyRedundancy Member of Power.v1_7_1.Power
Description | This indicates if the Power Supply is redundant or not. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
Redundant |
The power supplies are Redundant. |
NonRedundant |
The power supplies are not Redundant. |
FailedRedundant |
The Redundant power supply has failed. |
Unknown |
The Redundant state is unknown. |
Domains[{item}].Status Member of Power.v1_7_1.Power See the Redfish standard schema and specification for information on common Status object.
Oem.Hpe.FanPowerRequirement
Member of Power.v1_7_1.Power
Description | Cooling challenge bucket definition. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.FanPowerRequirementErrors
Member of Power.v1_7_1.Power
Description | Cooling challenge errors. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.FanPowerRequirementVersion
Member of Power.v1_7_1.Power
Description | Version of the Synergy cooling table bucket definitions. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.HasCpuPowerMetering
Member of Power.v1_7_1.Power
Description | Indicates if the system has CPU power metering. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.HasDimmPowerMetering
Member of Power.v1_7_1.Power
Description | Indicates if the system has DIMM power metering. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.HasFanPowerMetering
Member of Power.v1_7_1.Power
Description | Indicates if the system has fan power metering. |
Type | boolean |
Read Only | True |
Added | iLO6 1.63 |
Oem.Hpe.HasGpuPowerMetering
Member of Power.v1_7_1.Power
Description | Indicates if the system has GPU power metering. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.HasPowerMetering
Member of Power.v1_7_1.Power
Description | Indicates if the system has power metering. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.HighEfficiencyMode
Member of Power.v1_7_1.Power
Description | The redundant power supply mode that will be used when redundant power supplies are configured. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Null |
Auto |
Balanced |
Even |
Odd |
NoSupport |
Oem.Hpe.MinimumSafelyAchievableCap
Member of Power.v1_7_1.Power
Description | Minimum Safely Achievable Cap is the lowest cap value that is safe for a group power manager to apply to a particular server. It can either be identical to or slightly greater than the 0 percent cap value calculated during ROM power burn. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.MinimumSafelyAchievableCapValid
Member of Power.v1_7_1.Power
Description | Indicates if the msac is valid. msac is valid only if this is true. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.PowerMetric
Oem.Hpe.PowerMetric.AmbTemp Member of Power.v1_7_1.Power
Description | Ambient temperature, in degrees Celsius. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.51 |
Oem.Hpe.PowerMetric.Cap Member of Power.v1_7_1.Power
Description | The applicable power cap in Watts at the time of this power sample. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.51 |
Oem.Hpe.PowerMetric.CpuCapLim Member of Power.v1_7_1.Power
Description | Measures the effect of the power cap on performance in percent. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.51 |
Oem.Hpe.PowerMetric.CpuMax Member of Power.v1_7_1.Power
Description | The percentage of time the CPU spent in its maximum power mode. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.51 |
Oem.Hpe.PowerMetric.CpuPwrSavLim Member of Power.v1_7_1.Power
Description | Measures the effect of CPU Power Regulator state switching on performance in percent. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.51 |
Oem.Hpe.PowerMetric.CpuWatts Member of Power.v1_7_1.Power
Description | The power consumed by the system CPUs in Watts. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.51 |
Oem.Hpe.PowerMetric.DimmWatts Member of Power.v1_7_1.Power
Description | The power consumed by the system memory DIMMs in Watts. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.51 |
Oem.Hpe.PowerMetric.GpuWatts Member of Power.v1_7_1.Power
Description | The power consumed by the GPU(s) in Watts. This will be 0 if no GPUs are installed or if the drivers are not loaded. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.51 |
Oem.Hpe.PowerMetric.PrMode Member of Power.v1_7_1.Power
Description | Power Regulator mode, which can be OS Control, Static High, Static Low or Dynamic. |
Type | string or null |
Read Only | True |
Added | iLO6 1.51 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
dyn |
Dynamic Mode - CPU power regulation is managed dynamically by the firmware. |
min |
Minimum Mode - CPU power regulation is configured to save as much power as possible at the possible expense of performance. |
max |
Maximum Mode - CPU power regulation is configured for maximum performance at the possible expense of power efficiency. |
osc |
OS Control Mode - CPU power regulation is managed by the Operating System. |
Oem.Hpe.PowerMetric.PunCap Member of Power.v1_7_1.Power
Description | If true, CPU performance is being penalized by the current power cap. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.51 |
Oem.Hpe.PowerMetric.UnachCap Member of Power.v1_7_1.Power
Description | If true, the configured power cap could not be achieved due to system power requirements. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.51 |
Oem.Hpe.SNMPPowerThresholdAlert
Oem.Hpe.SNMPPowerThresholdAlert.DurationInMin Member of Power.v1_7_1.Power
Description | Sets the length of time, in minutes, that power consumption must remain above the warning threshold before an SNMP alert is triggered. The maximum duration is 240 minutes, and the duration must be a multiple of 5. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.SNMPPowerThresholdAlert.ThresholdWatts Member of Power.v1_7_1.Power
Description | Sets the power consumption threshold (watts). If power consumption exceeds this value for the specified time duration, an SNMP alert is triggered. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.SNMPPowerThresholdAlert.Trigger Member of Power.v1_7_1.Power
Description | Trigger determines whether alerts are based on peak power consumption, average power consumption, or if they are disabled. Trigger property can only be enabled if the ThresholdWatts and DurationInMin values are specified/configured. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Disabled |
AveragePowerConsumption |
PeakPowerConsumption |
PowerControl (array)
Member of Power.v1_7_1.Power
PowerControl
is an array containing elements of:
PowerControl[{item}].@odata.id Member of Power.v1_7_1.Power
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
PowerControl[{item}].MemberId Member of Power.v1_7_1.Power
Description | This is the identifier for the member within the collection. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerAllocatedWatts Member of Power.v1_7_1.Power
Description | The total amount of power that has been allocated (or budegeted)to chassis resources. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerAvailableWatts Member of Power.v1_7_1.Power
Description | The amount of power not already budgeted and therefore available for additional allocation. (powerCapacity - powerAllocated). This indicates how much reserve power capacity is left. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerCapacityWatts Member of Power.v1_7_1.Power
Description | The total amount of power available to the chassis for allocation. This may the power supply capacity, or power budget assigned to the chassis from an up-stream chassis. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerConsumedWatts Member of Power.v1_7_1.Power
Description | The actual power being consumed by the chassis. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerLimit PowerControl[{item}].PowerLimit.CorrectionInMs Member of Power.v1_7_1.Power
Description | The time required for the limiting process to reduce power consumption to below the limit. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerLimit.LimitException Member of Power.v1_7_1.Power
Description | The action that is taken if the power cannot be maintained below the LimitInWatts. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NoAction |
Take no action when the limit is exceeded. |
HardPowerOff |
Turn the power off immediately when the limit is exceeded. |
LogEventOnly |
Log an event when the limit is exceeded, but take no further action. |
Oem |
Take an OEM-defined action. |
PowerControl[{item}].PowerLimit.LimitInWatts Member of Power.v1_7_1.Power
Description | The Power limit in watts. Set to null to disable power capping. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
PowerControl[{item}].PowerMetrics PowerControl[{item}].PowerMetrics.AverageConsumedWatts Member of Power.v1_7_1.Power
Description | The average power level over the measurement window (the last IntervalInMin minutes). |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerMetrics.IntervalInMin Member of Power.v1_7_1.Power
Description | The time interval (or window) in which the PowerMetrics are measured over. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerMetrics.MaxConsumedWatts Member of Power.v1_7_1.Power
Description | The highest power consumption level that has occured over the measurement window (the last IntervalInMin minutes). |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerMetrics.MinConsumedWatts Member of Power.v1_7_1.Power
Description | The lowest power consumption level over the measurement window (the last IntervalInMin minutes). |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].PowerRequestedWatts Member of Power.v1_7_1.Power
Description | The potential power that the chassis resources are requesting which may be higher than the current level being consumed since requested power includes budget that the chassis resource wants for future use. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PowerControl[{item}].RelatedItem (array) Member of Power.v1_7_1.Power
RelatedItem
is an array containing elements of:
RelatedItem[{item}].@odata.id Member of Power.v1_7_1.Power
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
PowerControl[{item}].Status Member of Power.v1_7_1.Power See the Redfish standard schema and specification for information on common Status object.
PowerSupplies (array)
Member of Power.v1_7_1.Power
PowerSupplies
is an array containing elements of:
PowerSupplies[{item}].@odata.id Member of Power.v1_7_1.Power
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
PowerSupplies[{item}].FirmwareVersion Member of Power.v1_7_1.Power
Description | The firmware version for this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].LastPowerOutputWatts Member of Power.v1_7_1.Power
Description | The average power output of this Power Supply |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].LineInputVoltage Member of Power.v1_7_1.Power
Description | The line input voltage at which the Power Supply is operating |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].LineInputVoltageType Member of Power.v1_7_1.Power
Description | The line voltage type supported as an input to this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The power supply line input voltage type cannot be determined. |
ACLowLine |
100-127V AC input. |
ACMidLine |
200-240V AC input. |
ACHighLine |
277V AC input. |
DCNeg48V |
-48V DC input. |
HighVoltageDC |
High Voltage DC input (380V). |
PowerSupplies[{item}].Manufacturer Member of Power.v1_7_1.Power
Description | This is the manufacturer of this power supply. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].MemberId Member of Power.v1_7_1.Power
Description | This is the identifier for the member within the collection. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Model Member of Power.v1_7_1.Power
Description | The model number for this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.AveragePowerOutputWatts Member of Power.v1_7_1.Power
Description | The latest observed average power being drawn by the power supply (Watts). This is usually updated every 10 seconds but the period can vary in some circumstances. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.BayNumber Member of Power.v1_7_1.Power
Description | The power supply bay number. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.Domain Member of Power.v1_7_1.Power
Description | This indicates the domain of the specific power supply. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value |
---|
System |
GPU |
PowerSupplies[{item}].Oem.Hpe.HotplugCapable Member of Power.v1_7_1.Power
Description | If true, this power supply (and power supply bay) is capable of being hot-plugged. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.MaxPowerOutputWatts Member of Power.v1_7_1.Power
Description | The latest observed maximum output power being drawn by the power supply (Watts). This is usually updated every 10 seconds but the period can vary in some circumstances. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.Mismatched Member of Power.v1_7_1.Power
Description | If true, this power supply is mismatched with others in the system. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.PowerSupplyStatus PowerSupplies[{item}].Oem.Hpe.PowerSupplyStatus.State Member of Power.v1_7_1.Power
Description | Indicates the known state of the resource. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Unknown |
Ok |
Degraded |
Failed |
OverVoltage |
OverCurrent |
OverTemperature |
ACPowerLost |
FanFailure |
WarningHighInputVoltage |
WarningLowInputVoltage |
WarningHighOutputVoltage |
WarningLowOutputVoltage |
WarningInletTemperature |
WarningInternalTemperature |
WarningHighAuxiliaryVoltage |
WarningLowAuxiliaryVoltage |
PowerSupplyMismatch |
GoodInStandby |
PowerSupplies[{item}].Oem.Hpe.iPDU PowerSupplies[{item}].Oem.Hpe.iPDU.IPAddress Member of Power.v1_7_1.Power
Description | The IP address of the iPDU connected to this power supply. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.iPDU.MacAddress Member of Power.v1_7_1.Power
Description | The Ethernet MAC address of the iPDU connected to this power supply. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.iPDU.Model Member of Power.v1_7_1.Power
Description | The model number of the iPDU connected to this power supply. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.iPDU.SerialNumber Member of Power.v1_7_1.Power
Description | The serial number of the iPDU connected to this power supply. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Oem.Hpe.iPDU.iPDUStatus PowerSupplies[{item}].Oem.Hpe.iPDU.iPDUStatus.State Member of Power.v1_7_1.Power
Description | Indicates the known state of the resource. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Unknown |
Ok |
Degraded |
Failed |
OverVoltage |
OverCurrent |
OverTemperature |
ACPowerLost |
FanFailure |
WarningHighInputVoltage |
WarningLowInputVoltage |
WarningHighOutputVoltage |
WarningLowOutputVoltage |
WarningInletTemperature |
WarningInternalTemperature |
WarningHighAuxiliaryVoltage |
WarningLowAuxiliaryVoltage |
PowerSupplyMismatch |
GoodInStandby |
PowerSupplies[{item}].Oem.Hpe.iPDUCapable Member of Power.v1_7_1.Power
Description | If true, this power supply is capable of being connected to an iPDUs. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].PartNumber Member of Power.v1_7_1.Power
Description | The part number for this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].PowerCapacityWatts Member of Power.v1_7_1.Power
Description | The maximum capacity of this Power Supply |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].PowerSupplyType Member of Power.v1_7_1.Power
Description | The Power Supply type (AC or DC) |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Unknown |
The power supply type cannot be determined |
AC |
Alternating Current (AC) power supply |
DC |
Direct Current (DC) power supply |
PowerSupplies[{item}].Redundancy Member of Power.v1_7_1.Power See the Redfish standard schema and specification for information on common Redundancy object.
PowerSupplies[{item}].RelatedItem (array) Member of Power.v1_7_1.Power
RelatedItem
is an array containing elements of:
RelatedItem[{item}].@odata.id Member of Power.v1_7_1.Power
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
PowerSupplies[{item}].SerialNumber Member of Power.v1_7_1.Power
Description | The serial number for this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].SparePartNumber Member of Power.v1_7_1.Power
Description | The spare part number for this Power Supply |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
PowerSupplies[{item}].Status Member of Power.v1_7_1.Power See the Redfish standard schema and specification for information on common Status object.
Redundancy
Member of Power.v1_7_1.Power See the Redfish standard schema and specification for information on common Redundancy object.
Status
Member of Power.v1_7_1.Power See the Redfish standard schema and specification for information on common Status object.
Voltages (array)
Member of Power.v1_7_1.Power
Voltages
is an array containing elements of:
Voltages[{item}].@odata.id Member of Power.v1_7_1.Power
Type | string |
Read Only | True |
Added | iLO6 1.57 |
Format | uri-reference |
Voltages[{item}].LowerThresholdCritical Member of Power.v1_7_1.Power
Description | Below normal range but not yet fatal. |
Type | number or null |
Read Only | True |
Added | iLO6 1.57 |
Voltages[{item}].LowerThresholdFatal Member of Power.v1_7_1.Power
Description | Below normal range and is fatal |
Type | number or null |
Read Only | True |
Added | iLO6 1.57 |
Voltages[{item}].LowerThresholdNonCritical Member of Power.v1_7_1.Power
Description | Below normal range |
Type | number or null |
Read Only | True |
Added | iLO6 1.57 |
Voltages[{item}].MaxReadingRange Member of Power.v1_7_1.Power
Description | Maximum value for CurrentReading |
Type | integer or null |
Read Only | True |
Added | iLO6 1.57 |
Voltages[{item}].MemberId Member of Power.v1_7_1.Power
Description | This is the identifier for the member within the collection. |
Type | string |
Read Only | True |
Added | iLO6 1.57 |
Voltages[{item}].MinReadingRange Member of Power.v1_7_1.Power
Description | Minimum value for CurrentReading |
Type | integer or null |
Read Only | True |
Added | iLO6 1.57 |
Voltages[{item}].PhysicalContext Member of Power.v1_7_1.Power
Description | Describes the area or device to which this voltage measurement applies. |
Type | string or null |
Read Only | True |
Added | iLO6 1.57 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Room |
The room |
Intake |
The intake point of the chassis |
Exhaust |
The exhaust point of the chassis |
Front |
The front of the chassis |
Back |
The back of the chassis |
Upper |
The upper portion of the chassis |
Lower |
The lower portion of the chassis |
CPU |
A Processor (CPU) |
GPU |
A Graphics Processor (GPU) |
Backplane |
A backplane within the chassis |
SystemBoard |
The system board (PCB) |
PowerSupply |
A power supply |
VoltageRegulator |
A voltage regulator device |
StorageDevice |
A storage device |
NetworkingDevice |
A networking device |
ComputeBay |
Within a compute bay |
StorageBay |
Within a storage bay |
NetworkBay |
Within a networking bay |
ExpansionBay |
Within an expansion bay |
PowerSupplyBay |
Within a power supply bay |
Voltages[{item}].ReadingVolts Member of Power.v1_7_1.Power
Description | The current value of the voltage sensor. |
Type | number or null |
Read Only | True |
Added | iLO6 1.57 |
Voltages[{item}].RelatedItem (array) Member of Power.v1_7_1.Power
RelatedItem
is an array containing elements of:
RelatedItem[{item}].@odata.id Member of Power.v1_7_1.Power
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Voltages[{item}].SensorNumber Member of Power.v1_7_1.Power
Description | A numerical identifier to represent the voltage sensor |
Type | integer or null |
Read Only | True |
Added | iLO6 1.57 |
Voltages[{item}].Status Member of Power.v1_7_1.Power See the Redfish standard schema and specification for information on common Status object.
Voltages[{item}].UpperThresholdCritical Member of Power.v1_7_1.Power
Description | Above normal range but not yet fatal. |
Type | number or null |
Read Only | True |
Added | iLO6 1.57 |
Voltages[{item}].UpperThresholdFatal Member of Power.v1_7_1.Power
Description | Above normal range and is fatal |
Type | number or null |
Read Only | True |
Added | iLO6 1.57 |
Voltages[{item}].UpperThresholdNonCritical Member of Power.v1_7_1.Power
Description | Above normal range |
Type | number or null |
Read Only | True |
Added | iLO6 1.57 |
Processor
@odata.type: "#Processor.v1_8_2.Processor"
The Processor resource describes the Processor resource. It represents the properties of a processor attached to a System.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/processors/{item} |
GET |
EnvironmentMetrics
The link to the environment metrics for this processor.
EnvironmentMetrics is a link ("@odata.id": URI
) to another resource.
InstructionSet
Member of Processor.v1_8_2.Processor
Description | The instruction set of the processor |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
x86 |
x86 32-bit |
x86-64 |
x86 64-bit |
IA-64 |
Intel IA-64 |
ARM-A32 |
ARM 32-bit |
ARM-A64 |
ARM 64-bit |
MIPS32 |
MIPS 32-bit |
MIPS64 |
MIPS 64-bit |
OEM |
OEM-defined |
Manufacturer
Member of Processor.v1_8_2.Processor
Description | The processor manufacturer |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MaxSpeedMHz
Member of Processor.v1_8_2.Processor
Description | The maximum clock speed of the processor |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Metrics
This property shall contain a link to a resource of type ProcessorMetrics that contains the metrics associated with this processor.
Metrics is a link ("@odata.id": URI
) to another resource.
Model
Member of Processor.v1_8_2.Processor
Description | The product model number of this device |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.AssetTag
Member of Processor.v1_8_2.Processor
Description | The processor asset tag. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Cache (array)
Member of Processor.v1_8_2.Processor
Cache
is an array containing elements of:
Cache[{item}].Associativity Member of Processor.v1_8_2.Processor
Description | The associativity of the cache. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
DirectMapped |
Direct Mapped |
2waySetAssociative |
2-way Set-Associative |
4waySetAssociative |
4-way Set-Associative |
FullyAssociative |
Fully Associative |
8waySetAssociative |
8-way Set-Associative |
16waySetAssociative |
16-way Set-Associative |
12waySetAssociative |
12-way Set-Associative |
24waySetAssociative |
24-way Set-Associative |
32waySetAssociative |
32-way Set-Associative |
48waySetAssociative |
48-way Set-Associative |
64waySetAssociative |
64-way Set-Associative |
20waySetAssociative |
20-way Set-Associative |
None |
Cache[{item}].CacheSpeedns Member of Processor.v1_8_2.Processor
Description | The cache speed (ns). |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Cache[{item}].CurrentSRAMType (array) Member of Processor.v1_8_2.Processor
CurrentSRAMType
is an array containing elements of:
CurrentSRAMType[{item}] Member of Processor.v1_8_2.Processor
Description | The array of supported SRAM attributes currently used by the cache. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NonBurst |
Non-Burst |
Burst |
Burst |
PipelineBurst |
Pipeline Burst |
Synchronous |
Synchronous |
Asynchronous |
Asynchronous |
Cache[{item}].EccType Member of Processor.v1_8_2.Processor
Description | The cache memory ECC type. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
None |
None |
Parity |
Parity |
SingleBitECC |
Single-bit ECC |
MultiBitECC |
Multi-bit ECC |
Cache[{item}].InstalledSizeKB Member of Processor.v1_8_2.Processor
Description | The installed cache size (KB). |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Cache[{item}].Location Member of Processor.v1_8_2.Processor
Description | The cache location (internal or external). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Internal |
Internal |
External |
External |
Cache[{item}].MaximumSizeKB Member of Processor.v1_8_2.Processor
Description | The maximum cache size (KB). |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Cache[{item}].Policy Member of Processor.v1_8_2.Processor
Description | The caching policy. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
WriteThrough |
Write through |
WriteBack |
Write back |
Varies |
Varies with memory address |
Cache[{item}].Socketed Member of Processor.v1_8_2.Processor
Description | If true, the cache is a socketed component. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Cache[{item}].Status Member of Processor.v1_8_2.Processor See the Redfish standard schema and specification for information on common Status object.
Cache[{item}].SupportedSRAMType (array) Member of Processor.v1_8_2.Processor
SupportedSRAMType
is an array containing elements of:
SupportedSRAMType[{item}] Member of Processor.v1_8_2.Processor
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
NonBurst |
Non-Burst |
Burst |
Burst |
PipelineBurst |
Pipeline Burst |
Synchronous |
Synchronous |
Asynchronous |
Asynchronous |
Cache[{item}].SystemCacheType Member of Processor.v1_8_2.Processor
Description | The cache type (unified, instructions, or data). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Instruction |
Instruction |
Data |
Data |
Unified |
Unified |
Oem.Hpe.Characteristics (array)
Member of Processor.v1_8_2.Processor
Characteristics
is an array containing elements of:
Characteristics[{item}] Member of Processor.v1_8_2.Processor
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
64Bit |
64-bit Capable |
MultiCore |
Multi-Core |
HwThread |
Hardware Thread |
ExecuteProtection |
Execute Protection |
EnhancedVirtualization |
Enhanced Virtualization |
PowerPerfControl |
Power/Performance Control |
Oem.Hpe.ConfigStatus
Oem.Hpe.ConfigStatus.Populated Member of Processor.v1_8_2.Processor
Description | True if the processor socket is populated with a CPU. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ConfigStatus.State Member of Processor.v1_8_2.Processor
Description | The current state of the processor. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
CPU Enabled |
DisabledByUser |
CPU Disabled by User through BIOS Setup |
DisabledByBios |
CPU Disabled By BIOS (POST Error) |
Idle |
CPU is Idle, waiting to be enabled. |
Oem.Hpe.CoresEnabled
Member of Processor.v1_8_2.Processor
Description | The number of enabled cores in the processor. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DOTState
Member of Processor.v1_8_2.Processor
Description | Provides current ownership state of NVidia CPU ERoT |
Type | string or null |
Read Only | True |
Added | iLO6 1.62 |
The following are the supported values:
Value | Description |
---|---|
Unknown |
CAK Keys are not yet installed on the module or the CAK Test failed |
Unlocked |
The NVidia CPU ERoT is not locked with LAK Keys |
Locked |
The NVidia CPU ERoT has been locked with CAK & LAK Keys |
Oem.Hpe.ExternalClockMHz
Member of Processor.v1_8_2.Processor
Description | The processor external clock frequency (MHZ), for example, 1000 = 1 GHZ. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.MicrocodePatches (array)
Member of Processor.v1_8_2.Processor
MicrocodePatches
is an array containing elements of:
MicrocodePatches[{item}].CpuId Member of Processor.v1_8_2.Processor
Description | The microcode patch CPUID. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
MicrocodePatches[{item}].Date Member of Processor.v1_8_2.Processor
Description | The microcode patch date. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
MicrocodePatches[{item}].PatchId Member of Processor.v1_8_2.Processor
Description | The microcode patch ID. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.NVLinkState
Member of Processor.v1_8_2.Processor
Description | The Link between CPU and GPU . |
Type | string or null |
Read Only | True |
Added | iLO6 1.61 |
The following are the supported values:
Value | Description |
---|---|
Inactive |
The link between CPU and GPU is inactive |
Active |
The link between CPU and GPU is active |
Error |
There is an error while establishing link between CPU and GPU |
Oem.Hpe.PartNumber
Member of Processor.v1_8_2.Processor
Description | The processor part number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.RatedSpeedMHz
Member of Processor.v1_8_2.Processor
Description | The speed of the processor (in MHz) as of the last system boot, for example, 1000 = 1GHz. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.SerialNumber
Member of Processor.v1_8_2.Processor
Description | The processor serial number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.VoltageVoltsX10
Member of Processor.v1_8_2.Processor
Description | The processor voltage multiplied by 10, for example, 3.3v = 33. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
PartNumber
Member of Processor.v1_8_2.Processor
Description | The processor part number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorArchitecture
Member of Processor.v1_8_2.Processor
Description | The architecture of the processor |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
x86 |
x86 or x86-64 |
IA-64 |
Intel Itanium |
ARM |
ARM |
MIPS |
MIPS |
OEM |
OEM-defined |
ProcessorId
ProcessorId.EffectiveFamily Member of Processor.v1_8_2.Processor
Description | The effective Family for this processor |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorId.EffectiveModel Member of Processor.v1_8_2.Processor
Description | The effective Model for this processor |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorId.IdentificationRegisters Member of Processor.v1_8_2.Processor
Description | The contents of the Identification Registers (CPUID) for this processor |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorId.MicrocodeInfo Member of Processor.v1_8_2.Processor
Description | The Microcode Information for this processor |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorId.Step Member of Processor.v1_8_2.Processor
Description | The Step value for this processor |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorId.VendorId Member of Processor.v1_8_2.Processor
Description | The Vendor Identification for this processor |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorType
Member of Processor.v1_8_2.Processor
Description | The type of processor |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
CPU |
A Central Processing Unit |
GPU |
A Graphics Processing Unit |
FPGA |
A Field Programmable Gate Array |
DSP |
A Digital Signal Processor |
Accelerator |
An Accelerator |
OEM |
An OEM-defined Processing Unit |
SerialNumber
Member of Processor.v1_8_2.Processor
Description | The processor serial number. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Socket
Member of Processor.v1_8_2.Processor
Description | The socket or location of the processor |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of Processor.v1_8_2.Processor See the Redfish standard schema and specification for information on common Status object.
TotalCores
Member of Processor.v1_8_2.Processor
Description | The total number of cores contained in this processor |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
TotalThreads
Member of Processor.v1_8_2.Processor
Description | The total number of execution threads supported by this processor |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
ProcessorCollection
@odata.type: "#ProcessorCollection.ProcessorCollection"
A Collection of Processor resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/processors |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Processor |
Members (array)
Member of ProcessorCollection.ProcessorCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of ProcessorCollection.ProcessorCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of ProcessorCollection.ProcessorCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
ProcessorMetrics
@odata.type: "#ProcessorMetrics.v1_6_4.ProcessorMetrics"
The ProcessorMetrics schema contains usage and health statistics for a processor.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/processors/{item}/processormetrics |
GET |
BandwidthPercent
Member of ProcessorMetrics.v1_6_4.ProcessorMetrics
Description | The bandwidth usage of this processor as a percentage. |
Type | number or null |
Read Only | True |
Added | iLO6 1.61 |
Oem.Hpe.EDPViolationStateType
Member of ProcessorMetrics.v1_6_4.ProcessorMetrics
Description | EDP violation. |
Type | string or null |
Read Only | True |
Added | iLO6 1.61 |
The following are the supported values:
Value | Description |
---|---|
Normal |
The value is within the range |
OutOfRange |
The value is outside the range |
Oem.Hpe.MemorySpareChannelPresence
Member of ProcessorMetrics.v1_6_4.ProcessorMetrics
Description | The memory spare channel presence state. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.61 |
Oem.Hpe.PCIeConnectionLinksStatus (array)
Member of ProcessorMetrics.v1_6_4.ProcessorMetrics
PCIeConnectionLinksStatus
is an array containing elements of:
PCIeConnectionLinksStatus[{item}] Member of ProcessorMetrics.v1_6_4.ProcessorMetrics
Type | string or null |
Read Only | True |
Added | iLO6 1.61 |
The following are the supported values:
Value | Description |
---|---|
Connected |
This channel between GPU and CPU is connected |
Disconnected |
This channel between GPU and CPU is not connected |
Oem.Hpe.PerformanceState
Member of ProcessorMetrics.v1_6_4.ProcessorMetrics
Description | The performance state |
Type | string or null |
Read Only | True |
Added | iLO6 1.61 |
The following are the supported values:
Value | Description |
---|---|
Degraded |
The entity is operating at a degraded functional level |
Normal |
The entity is operating at a full functional level at full speed |
Throttled |
The entity is operating at a full functional level at reduced speed |
Oem.Hpe.PowerBreakPerformanceState
Member of ProcessorMetrics.v1_6_4.ProcessorMetrics
Description | The power break performance state |
Type | string or null |
Read Only | True |
Added | iLO6 1.61 |
The following are the supported values:
Value | Description |
---|---|
Degraded |
The entity is operating at a degraded functional level |
Normal |
The value is within the range |
Throttled |
The value is outside the range |
Pump
@odata.type: "#Pump.v1_1_0.Pump"
The Pump schema describes a pump unit for a cooling system or similar device.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/thermalsubsystem/pumps/{item} |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Assembly |
Assembly |
Assembly
The link to the summary of assembly for this subsystem.
Assembly is a link ("@odata.id": URI
) to another resource.
PhysicalContext
Member of Pump.v1_1_0.Pump
Description | The area or device associated with this pump. |
Type | string or null |
Read Only | True |
Added | iLO6 1.63 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Room |
The room |
Intake |
The intake point of the chassis |
Exhaust |
The exhaust point of the chassis |
Front |
The front of the chassis |
Back |
The back of the chassis |
Upper |
The upper portion of the chassis |
Lower |
The lower portion of the chassis |
CPU |
A Processor (CPU) |
GPU |
A Graphics Processor (GPU) |
Backplane |
A backplane within the chassis |
SystemBoard |
The system board (PCB) |
PowerSupply |
A power supply |
VoltageRegulator |
A voltage regulator device |
StorageDevice |
A storage device |
NetworkingDevice |
A networking device |
ComputeBay |
Within a compute bay |
StorageBay |
Within a storage bay |
NetworkBay |
Within a networking bay |
ExpansionBay |
Within an expansion bay |
PowerSupplyBay |
Within a power supply bay |
PumpSpeedPercent
PumpSpeedPercent.DataSourceUri Member of Pump.v1_1_0.Pump
Description | The link to the resource that provides the data for this sensor. |
Type | string or null |
Read Only | True |
Added | iLO6 1.63 |
PumpSpeedPercent.Reading Member of Pump.v1_1_0.Pump
Description | The sensor value. |
Type | number or null |
Read Only | True |
Added | iLO6 1.63 |
PumpSpeedPercent.SpeedRPM Member of Pump.v1_1_0.Pump
Description | The rotational speed. |
Type | number or null |
Read Only | True |
Added | iLO6 1.63 |
Status
Member of Pump.v1_1_0.Pump See the Redfish standard schema and specification for information on common Status object.
PumpCollection
@odata.type: "#PumpCollection.PumpCollection"
The collection of Pump resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/thermalsubsystem/pumps |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Pump |
Members (array)
Member of PumpCollection.PumpCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of PumpCollection.PumpCollection
Type | string |
Read Only | True |
Added | iLO6 1.63 |
Format | uri-reference |
Members@odata.count
Member of PumpCollection.PumpCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.63 |
Role
@odata.type: "#Role.v1_2_1.Role"
This resource defines a user role to be used in conjunction with a Manager Account.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/roles/{item} |
GET PATCH |
AssignedPrivileges (array)
Member of Role.v1_2_1.Role
AssignedPrivileges
is an array containing elements of:
AssignedPrivileges[{item}] Member of Role.v1_2_1.Role
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Login |
Able to log into the service and read resources. |
ConfigureManager |
Able to configure Manager resources. |
ConfigureUsers |
Able to configure Users and their Accounts. |
ConfigureSelf |
Able to change the password for the current user Account. |
ConfigureComponents |
Able to configure components managed by this service. |
IsPredefined
Member of Role.v1_2_1.Role
Description | This property is used to indicate if the Role is one of the Redfish Predefined Roles vs a Custom role. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.GroupDn
Member of Role.v1_2_1.Role
Description | The complete or shortened distinguished name of the directory group. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.GroupSid
Member of Role.v1_2_1.Role
Description | The security identifier of the directory group (for kerberos authentication and Active Directory integration only). |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
OemPrivileges (array)
Member of Role.v1_2_1.Role
OemPrivileges
is an array containing elements of:
OemPrivileges[{item}] Member of Role.v1_2_1.Role
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
RemoteConsolePriv |
Able to remotely access the host system Remote Console, including video, keyboard, and mouse control. |
VirtualMediaPriv |
Able to use the Virtual Media feature on the host system. |
VirtualPowerAndResetPriv |
Able to power-cycle or reset the host system. These activities interrupt system availability. A user with this privilege can diagnose the system by using the Generate NMI to System button. |
HostBIOSConfigPriv |
Able to configure Host BIOS Settings. |
HostNICConfigPriv |
Able to configure Host NIC Settings. |
HostStorageConfigPriv |
Able to configure Host Storage Settings. |
SystemRecoveryConfigPriv |
Able to manage the critical recovery firmware images on the Manager's Repository. |
RoleId
Member of Role.v1_2_1.Role
Description | This property contains the name of the Role. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
RoleCollection
@odata.type: "#RoleCollection.RoleCollection"
A Collection of Role resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/accountservice/roles |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Role |
Members (array)
Member of RoleCollection.RoleCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of RoleCollection.RoleCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of RoleCollection.RoleCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
SecureBoot
@odata.type: "#SecureBoot.v1_1_0.SecureBoot"
This resource contains UEFI Secure Boot information. It represents properties for managing the UEFI Secure Boot functionality of a system.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/secureboot |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
securebootdatabases |
Collection of SecureBootDatabase |
SecureBootCurrentBoot
Member of SecureBoot.v1_1_0.SecureBoot
Description | Secure Boot state during the current boot cycle. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Enabled |
Secure Boot is currently enabled. |
Disabled |
Secure Boot is currently disabled. |
SecureBootDatabases
A link to the collection of UEFI Secure Boot databases.
SecureBootDatabases is a link ("@odata.id": URI
) to another resource.
SecureBootEnable
Member of SecureBoot.v1_1_0.SecureBoot
Description | Enable or disable UEFI Secure Boot (takes effect on next boot). |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
SecureBootMode
Member of SecureBoot.v1_1_0.SecureBoot
Description | Current Secure Boot Mode. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
SetupMode |
Secure Boot is currently in Setup Mode. |
UserMode |
Secure Boot is currently in User Mode. |
AuditMode |
Secure Boot is currently in Audit Mode. |
DeployedMode |
Secure Boot is currently in Deployed Mode. |
Actions
SecureBoot.ResetKeys Member of SecureBoot.v1_1_0.SecureBoot Action to perform reset of the Secure Boot Keys.
Parameters:
ResetKeysType (string)
This parameter specifies what type of reset action to perform.
Value | Description |
---|---|
ResetAllKeysToDefault | Reset to default Secure Boot keys on next boot. |
DeletePK | Delete Secure Boot platform keys on next boot. |
DeleteAllKeys | Delete all Secure Boot keys on next boot. |
SecureBootDatabase
@odata.type: "#SecureBootDatabase.v1_0_0.SecureBootDatabase"
The SecureBootDatabase schema describes a UEFI Secure Boot database used to store certificates or hashes.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/PK |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/db |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbdefault |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbr |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbrdefault |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbt |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbtdefault |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbx |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbxdefault |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kek |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kekdefault |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/pkdefault |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Certificates |
Collection of Certificate |
Signatures |
Collection of Signature |
Certificates
A link to the collection of certificates contained in this UEFI Secure Boot database.
Certificates is a link ("@odata.id": URI
) to another resource.
DatabaseId
Member of SecureBootDatabase.v1_0_0.SecureBootDatabase
Description | This property contains the name of the UEFI Secure Boot database. |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Signatures
A link to the collection of signatures contained in this UEFI Secure Boot database.
Signatures is a link ("@odata.id": URI
) to another resource.
Actions
SecureBootDatabase.ResetKeys Member of SecureBootDatabase.v1_0_0.SecureBootDatabase Action to perform reset of the Secure Boot Database Keys.
Parameters:
ResetKeysType (string)
This parameter specifies what type of reset action to perform.
Value | Description |
---|---|
ResetAllKeysToDefault | Reset to default Secure Boot Database keys on next boot. |
DeleteAllKeys | Delete all Secure Boot Database keys on next boot. |
SecureBootDatabaseCollection
@odata.type: "#SecureBootDatabaseCollection.SecureBootDatabaseCollection"
The collection of SecureBootDatabase resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/secureboot/securebootdatabases |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
SecureBootDatabase |
Members (array)
Member of SecureBootDatabaseCollection.SecureBootDatabaseCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of SecureBootDatabaseCollection.SecureBootDatabaseCollection
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Format | uri-reference |
Members@odata.count
Member of SecureBootDatabaseCollection.SecureBootDatabaseCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.10 |
Sensor
@odata.type: "#Sensor.v1_10_0.Sensor"
The Sensor schema describes a sensor and its properties.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/sensors/{item} |
GET PATCH |
Oem.Hpe.LocationXmm
Member of Sensor.v1_10_0.Sensor
Description | The location of the sensor, in millimeters, along the X axis from the logical reference point. |
Type | integer |
Read Only | True |
Added | iLO6 1.63 |
Oem.Hpe.LocationYmm
Member of Sensor.v1_10_0.Sensor
Description | The location of the sensor, in millimeters, along the Y axis from the logical reference point. |
Type | integer |
Read Only | True |
Added | iLO6 1.63 |
PhysicalContext
Member of Sensor.v1_10_0.Sensor
Description | The area or device to which this sensor measurement applies. |
Type | string or null |
Read Only | True |
Added | iLO6 1.63 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Room |
The room |
Intake |
The intake point of the chassis |
Exhaust |
The exhaust point of the chassis |
Front |
The front of the chassis |
Back |
The back of the chassis |
Upper |
The upper portion of the chassis |
Lower |
The lower portion of the chassis |
CPU |
A Processor (CPU) |
GPU |
A Graphics Processor (GPU) |
Backplane |
A backplane within the chassis |
SystemBoard |
The system board (PCB) |
PowerSupply |
A power supply |
VoltageRegulator |
A voltage regulator device |
StorageDevice |
A storage device |
NetworkingDevice |
A networking device |
ComputeBay |
Within a compute bay |
StorageBay |
Within a storage bay |
NetworkBay |
Within a networking bay |
ExpansionBay |
Within an expansion bay |
PowerSupplyBay |
Within a power supply bay |
Reading
Member of Sensor.v1_10_0.Sensor
Description | The sensor value. |
Type | number or null |
Read Only | True |
Added | iLO6 1.61 |
Status
Member of Sensor.v1_10_0.Sensor See the Redfish standard schema and specification for information on common Status object.
Thresholds
Thresholds.LowerCaution Thresholds.LowerCaution.Activation Member of Sensor.v1_10_0.Sensor
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO6 1.63 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
Thresholds.LowerCaution.DwellTime Member of Sensor.v1_10_0.Sensor
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO6 1.63 |
Thresholds.LowerCaution.Reading Member of Sensor.v1_10_0.Sensor
Description | The threshold value. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.63 |
Thresholds.LowerCritical Thresholds.LowerCritical.Activation Member of Sensor.v1_10_0.Sensor
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO6 1.63 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
Thresholds.LowerCritical.DwellTime Member of Sensor.v1_10_0.Sensor
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO6 1.63 |
Thresholds.LowerCritical.Reading Member of Sensor.v1_10_0.Sensor
Description | The threshold value. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.63 |
Thresholds.UpperCaution Thresholds.UpperCaution.Activation Member of Sensor.v1_10_0.Sensor
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO6 1.63 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
Thresholds.UpperCaution.DwellTime Member of Sensor.v1_10_0.Sensor
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO6 1.63 |
Thresholds.UpperCaution.Reading Member of Sensor.v1_10_0.Sensor
Description | The threshold value. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.63 |
Thresholds.UpperCautionUser Thresholds.UpperCautionUser.Reading Member of Sensor.v1_10_0.Sensor
Description | The threshold value. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.63 |
Thresholds.UpperCritical Thresholds.UpperCritical.Activation Member of Sensor.v1_10_0.Sensor
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO6 1.63 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
Thresholds.UpperCritical.DwellTime Member of Sensor.v1_10_0.Sensor
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO6 1.63 |
Thresholds.UpperCritical.Reading Member of Sensor.v1_10_0.Sensor
Description | The threshold value. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.63 |
Thresholds.UpperCriticalUser Thresholds.UpperCriticalUser.Reading Member of Sensor.v1_10_0.Sensor
Description | The threshold value. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.63 |
Thresholds.UpperFatal Thresholds.UpperFatal.Activation Member of Sensor.v1_10_0.Sensor
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO6 1.63 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
Thresholds.UpperFatal.DwellTime Member of Sensor.v1_10_0.Sensor
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO6 1.63 |
Thresholds.UpperFatal.Reading Member of Sensor.v1_10_0.Sensor
Description | The threshold value. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.63 |
SensorCollection
@odata.type: "#SensorCollection.SensorCollection"
The collection of Sensor resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/sensors |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Sensor |
Members (array)
Member of SensorCollection.SensorCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of SensorCollection.SensorCollection
Type | string |
Read Only | True |
Added | iLO6 1.61 |
Format | uri-reference |
Members@odata.count
Member of SensorCollection.SensorCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.61 |
SerialInterface
@odata.type: "#SerialInterface.v1_1_7.SerialInterface"
This is the schema definition for the Serial Interface.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/serialinterfaces/{item} |
GET PATCH |
BitRate
Member of SerialInterface.v1_1_7.SerialInterface
Description | The receive and transmit rate of data flow, typically in bits per second (bit/s), over the serial connection. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
9600 |
A bit rate of 9600 bit/s. |
19200 |
A bit rate of 19200 bit/s. |
38400 |
A bit rate of 38400 bit/s. |
57600 |
A bit rate of 57600 bit/s. |
115200 |
A bit rate of 115200 bit/s. |
InterfaceEnabled
Member of SerialInterface.v1_1_7.SerialInterface
Description | An indication of whether this interface is enabled. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
SerialInterfaceCollection
@odata.type: "#SerialInterfaceCollection.SerialInterfaceCollection"
A Collection of SerialInterface resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/serialinterfaces |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
SerialInterface |
Members (array)
Member of SerialInterfaceCollection.SerialInterfaceCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of SerialInterfaceCollection.SerialInterfaceCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of SerialInterfaceCollection.SerialInterfaceCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Session
@odata.type: "#Session.v1_0_0.Session"
The Session resource describes a single connection (session) between a client and a Redfish service instance.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/sessionservice/sessions/{item} |
GET DELETE |
Oem.Hpe.AccessTime
Member of Session.v1_0_0.Session
Description | User session last-access time |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Oem.Hpe.LoginTime
Member of Session.v1_0_0.Session
Description | User session login time |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Oem.Hpe.MySession
Member of Session.v1_0_0.Session
Description | Indicates whether this is a session I own. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges
Oem.Hpe.Privileges.HostBIOSConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to configure Host Bios Settings. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.HostNICConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to configure Host NIC Settings. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.HostStorageConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to configure Host Storage Settings. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.LoginPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to log in to the management processor. All local accounts have the login privilege. This privilege is added automatically if it is not specified. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.RemoteConsolePriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to remotely access the host system Remote Console, including video, keyboard, and mouse control. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.SystemRecoveryConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to manage the critical recovery firmware images on the iLO Repository. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.UserConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to add, edit, and delete local management processor user accounts. A user with this privilege can change privileges for all users. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.VirtualMediaPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to use the Virtual Media feature on the host system. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.VirtualPowerAndResetPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to power-cycle or reset the host system. These activities interrupt system availability. A user with this privilege can diagnose the system by using the Generate NMI to System button. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Privileges.iLOConfigPriv Member of Session.v1_0_0.Session
Description | This privilege enables a user to configure most management processor settings, including security settings, and to remotely update the management processor firmware. This privilege does not enable local user account administration. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.UserAccount
Member of Session.v1_0_0.Session
Description | Login details of the user |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.UserDistinguishedName
Member of Session.v1_0_0.Session
Description | LDAP user is identified by its distinguished name (DN). |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.UserExpires
Member of Session.v1_0_0.Session
Description | User session expire time |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Oem.Hpe.UserIP
Member of Session.v1_0_0.Session
Description | IP address of the user |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.UserTag
Member of Session.v1_0_0.Session
Description | Session source |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Web UI |
RBSU |
Remote Console |
SSH |
IPMI/RMCP |
SM-CLP |
RIBCL |
RESTHost |
RIBCLHost |
WSMgmt |
Telnet |
Federation |
USBFrontPort |
REST |
Unknown |
Oem.Hpe.UserType
Member of Session.v1_0_0.Session
Description | User type |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Local |
Directory |
Single Sign On |
Kerberos |
Trusted Key |
Security Override |
System |
Federation |
UserName
Member of Session.v1_0_0.Session
Description | Name to use to log in to the management processor. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
SessionCollection
@odata.type: "#SessionCollection.SessionCollection"
A Collection of Session resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/sessionservice/sessions |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Oem/Hpe/Links/MySession |
Session |
Members[] |
Session |
Members (array)
Member of SessionCollection.SessionCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of SessionCollection.SessionCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of SessionCollection.SessionCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
SessionService
@odata.type: "#SessionService.v1_0_0.SessionService"
The SessionService resource describes the BMC Redfish Session Service. It represents the properties for the service itself and has links to the actual list of sessions.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/sessionservice |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Sessions |
Collection of Session |
ServiceEnabled
Member of SessionService.v1_0_0.SessionService
Description | This indicates whether this service is enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
SessionTimeout
Member of SessionService.v1_0_0.SessionService
Description | This is the number of seconds of inactivity that a session may have before the session service closes the session due to inactivity. Here the value 0 means no timeout or infinite timeout. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Sessions
This property references a Collection resource of Sessions.
Sessions is a link ("@odata.id": URI
) to another resource.
Status
Member of SessionService.v1_0_0.SessionService See the Redfish standard schema and specification for information on common Status object.
Signature
@odata.type: "#Signature.v1_0_2.Signature"
The Signature schema describes a signature or a hash.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/secureboot/securebootdatabases/db/signatures/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbdefault/signatures/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbr/signatures/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbrdefault/signatures/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbt/signatures/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbtdefault/signatures/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbx/signatures/{item} |
GET DELETE |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbxdefault/signatures/{item} |
GET DELETE |
SignatureString
Member of Signature.v1_0_2.Signature
Description | The string for the signature. |
Type | string |
Read Only | False |
Added | iLO6 1.10 |
SignatureType
Member of Signature.v1_0_2.Signature
Description | The format of the signature. |
Type | string |
Read Only | False |
Added | iLO6 1.10 |
SignatureTypeRegistry
Member of Signature.v1_0_2.Signature
Type | string |
Read Only | False |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
UEFI |
A signature defined in the UEFI Specification. |
UefiSignatureOwner
Member of Signature.v1_0_2.Signature
Description | The UEFI signature owner for this signature. |
Type | string or null |
Read Only | True |
Added | iLO6 1.10 |
SignatureCollection
@odata.type: "#SignatureCollection.SignatureCollection"
The collection of Signature resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/systems/{item}/secureBoot/securebootdatabases/dbdefault/signatures |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/db/signatures |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbr/signatures |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbrdefault/signatures |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbt/signatures |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbtdefault/signatures |
GET |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbx/signatures |
GET POST |
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbxdefault/signatures |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Signature |
Members (array)
Member of SignatureCollection.SignatureCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of SignatureCollection.SignatureCollection
Type | string |
Read Only | True |
Added | iLO6 1.10 |
Format | uri-reference |
Members@odata.count
Member of SignatureCollection.SignatureCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.10 |
SoftwareInventory
@odata.type: "#SoftwareInventory.v1_2_0.SoftwareInventory"
The SoftwareInventory resource describes the inventory of software or firmware components.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/firmwareinventory/{item} |
GET |
/redfish/v1/updateservice/softwareinventory/{item} |
GET |
LowestSupportedVersion
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | The lowest supported version of this software. |
Type | string or null |
Read Only | True |
Added | iLO6 1.61 |
Manufacturer
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | The manufacturer or producer of this software. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DeviceClass
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | DeviceType GUID rendered by iLO for certain items iLO knows how to flash, and omitted for all other items. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DeviceContext
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | Friendly text string - same as 'Location' in fw inventory - omitted if not available. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.DeviceInstance
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | UEFI Device Path if a PCI Device - omitted otherwise. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Targets (array)
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Targets
is an array containing elements of:
Targets[{item}] Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | A GUID indicating iLO's knowledge of a possible correlation GUIDs vs. components. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Version
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | NVIDIA CEC Firmware version |
Type | string or null |
Read Only | True |
Added | iLO6 1.30 |
RelatedItem (array)
Member of SoftwareInventory.v1_2_0.SoftwareInventory
RelatedItem
is an array containing elements of:
RelatedItem[{item}].@odata.id Member of SoftwareInventory.v1_2_0.SoftwareInventory
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
RelatedItem@odata.count
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | The number of items in a collection. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
SoftwareId
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | The implementation-specific label that identifies this software. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of SoftwareInventory.v1_2_0.SoftwareInventory See the Redfish standard schema and specification for information on common Status object.
Updateable
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | This is true if the item is updatable. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Version
Member of SoftwareInventory.v1_2_0.SoftwareInventory
Description | same as 'VersionString' in existing FwSwVersionInventory |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
SoftwareInventoryCollection
@odata.type: "#SoftwareInventoryCollection.SoftwareInventoryCollection"
A Collection of SoftwareInventory resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice/firmwareinventory |
GET |
/redfish/v1/updateservice/softwareinventory |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
SoftwareInventory |
Members (array)
Member of SoftwareInventoryCollection.SoftwareInventoryCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of SoftwareInventoryCollection.SoftwareInventoryCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of SoftwareInventoryCollection.SoftwareInventoryCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Switch
@odata.type: "#Switch.v1_9_1.Switch"
The Switch schema contains properties that describe a fabric switch.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/fabrics/{item}/switches/{item} |
GET POST |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
PortCollection |
DomainID
Member of Switch.v1_9_1.Switch
Description | The domain ID for this switch. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.54 |
FirmwareVersion
Member of Switch.v1_9_1.Switch
Description | The firmware version of this switch. |
Type | string or null |
Read Only | True |
Added | iLO6 1.54 |
Manufacturer
Member of Switch.v1_9_1.Switch
Description | The manufacturer of this switch. |
Type | string or null |
Read Only | True |
Added | iLO6 1.55 |
Model
Member of Switch.v1_9_1.Switch
Description | The product manufacturer-provided model number of this switch. |
Type | string or null |
Read Only | True |
Added | iLO6 1.54 |
Ports
The link to the collection ports for this switch.
Ports is a link ("@odata.id": URI
) to another resource.
SerialNumber
Member of Switch.v1_9_1.Switch
Description | The serial number for this switch. |
Type | string or null |
Read Only | True |
Added | iLO6 1.55 |
SupportedProtocols (array)
Member of Switch.v1_9_1.Switch
SupportedProtocols
is an array containing elements of:
SupportedProtocols[{item}] Member of Switch.v1_9_1.Switch
Type | string or null |
Read Only | True |
Added | iLO6 1.54 |
The following are the supported values:
Value | Description |
---|---|
PCIe |
PCI Express. |
AHCI |
Advanced Host Controller Interface (AHCI). |
UHCI |
Universal Host Controller Interface (UHCI). |
SAS |
Serial Attached SCSI. |
SATA |
Serial AT Attachment. |
USB |
Universal Serial Bus (USB). |
NVMe |
Non-Volatile Memory Express (NVMe). |
FC |
Fibre Channel. |
iSCSI |
Internet SCSI. |
FCoE |
Fibre Channel over Ethernet (FCoE). |
FCP |
Fibre Channel Protocol for SCSI. |
FICON |
FIbre CONnection (FICON). |
NVMeOverFabrics |
NVMe over Fabrics. |
SMB |
Server Message Block (SMB). Also known as the Common Internet File System (CIFS). |
NFSv3 |
Network File System (NFS) version 3. |
NFSv4 |
Network File System (NFS) version 4. |
HTTP |
Hypertext Transport Protocol (HTTP). |
HTTPS |
Hypertext Transfer Protocol Secure (HTTPS). |
FTP |
File Transfer Protocol (FTP). |
SFTP |
SSH File Transfer Protocol (SFTP). |
iWARP |
Internet Wide Area RDMA Protocol (iWARP). |
RoCE |
RDMA over Converged Ethernet Protocol. |
RoCEv2 |
RDMA over Converged Ethernet Protocol Version 2. |
I2C |
Inter-Integrated Circuit Bus. |
TCP |
Transmission Control Protocol (TCP). |
UDP |
User Datagram Protocol (UDP). |
TFTP |
Trivial File Transfer Protocol (TFTP). |
GenZ |
GenZ. |
MultiProtocol |
Multiple Protocols. |
InfiniBand |
InfiniBand. |
Ethernet |
Ethernet. |
NVLink |
NVLink. |
OEM |
OEM-specific. |
DisplayPort |
DisplayPort. |
HDMI |
HDMI. |
VGA |
VGA. |
DVI |
DVI. |
CXL |
Compute Express Link. |
SwitchType
Member of Switch.v1_9_1.Switch
Description | The protocol being sent over this switch. |
Type | string or null |
Read Only | True |
Added | iLO6 1.55 |
SwitchCollection
@odata.type: "#SwitchCollection.SwitchCollection"
A Collection of Switch Resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/fabrics/{item}/switches |
GET DELETE |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Collection of SwitchCollection |
Members (array)
Member of SwitchCollection.SwitchCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of SwitchCollection.SwitchCollection
Type | string |
Read Only | True |
Added | iLO6 1.54 |
Format | uri-reference |
Members@odata.count
Member of SwitchCollection.SwitchCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.54 |
Task
@odata.type: "#Task.v1_3_0.Task"
The Task resource describes a specific Task scheduled by or being executed by a Redfish service's Task Service.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/taskservice/tasks/{item} |
GET |
EndTime
Member of Task.v1_3_0.Task
Description | The date-time stamp that the task was last completed. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Messages (array)
Member of Task.v1_3_0.Task
Messages
is an array containing elements of:
Messages[{item}].Message Member of Task.v1_3_0.Task
Description | This is the human readable message, if provided. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Messages[{item}].MessageArgs (array) Member of Task.v1_3_0.Task
MessageArgs
is an array containing elements of:
MessageArgs[{item}] Member of Task.v1_3_0.Task
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Messages[{item}].MessageId Member of Task.v1_3_0.Task
Description | This is the key for this message which can be used to look up the message in a message registry. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Messages[{item}].RelatedProperties (array) Member of Task.v1_3_0.Task
RelatedProperties
is an array containing elements of:
RelatedProperties[{item}] Member of Task.v1_3_0.Task
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Messages[{item}].Resolution Member of Task.v1_3_0.Task
Description | Used to provide suggestions on how to resolve the situation that caused the error. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Messages[{item}].Severity Member of Task.v1_3_0.Task
Description | This is the severity of the event. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
OK |
Normal |
Warning |
A condition exists that requires attention |
Critical |
A critical condition exists that requires immediate attention |
Payload
Payload.HttpHeaders (array) Member of Task.v1_3_0.Task
HttpHeaders
is an array containing elements of:
HttpHeaders[{item}] Member of Task.v1_3_0.Task
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Payload.HttpOperation Member of Task.v1_3_0.Task
Description | The HTTP operation to perform to execute this Task. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Payload.JsonBody Member of Task.v1_3_0.Task
Description | This property contains the JSON payload to use in the execution of this Task. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Payload.TargetUri Member of Task.v1_3_0.Task
Description | The URI of the target for this task. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
StartTime
Member of Task.v1_3_0.Task
Description | The date-time stamp that the task was last started. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
TaskMonitor
Member of Task.v1_3_0.Task
Description | The URI of the Task Monitor for this task. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
TaskState
Member of Task.v1_3_0.Task
Description | The state of the task. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
New |
A new task. |
Starting |
Task is starting. |
Running |
Task is running normally. |
Suspended |
Task has been suspended. |
Interrupted |
Task has been interrupted. |
Pending |
Task is pending and has not started. |
Stopping |
Task is in the process of stopping. |
Completed |
Task has completed. |
Killed |
Task was terminated. |
Exception |
Task has stopped due to an exception condition. |
Service |
Task is running as a service. |
TaskStatus
Member of Task.v1_3_0.Task
Description | This is the completion status of the task. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
OK |
Normal. |
Warning |
A condition exists that requires attention. |
Critical |
A critical condition exists that requires immediate attention. |
TaskCollection
@odata.type: "#TaskCollection.TaskCollection"
A Collection of Task resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/taskservice/tasks |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Task |
Members (array)
Member of TaskCollection.TaskCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of TaskCollection.TaskCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of TaskCollection.TaskCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
TaskService
@odata.type: "#TaskService.v1_1_1.TaskService"
The TaskService resource describes the Task service. It represents the properties for the service itself and has links to the actual list of tasks.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/taskservice |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Tasks |
Collection of Task |
CompletedTaskOverWritePolicy
Member of TaskService.v1_1_1.TaskService
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Manual |
Completed tasks are not automatically overwritten. |
Oldest |
Oldest completed tasks are overwritten. |
DateTime
Member of TaskService.v1_1_1.TaskService
Description | The current DateTime (with offset) setting that the task service is using. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
LifeCycleEventOnTaskStateChange
Member of TaskService.v1_1_1.TaskService
Description | Send an Event upon Task State Change. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
ServiceEnabled
Member of TaskService.v1_1_1.TaskService
Description | This indicates whether this service is enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of TaskService.v1_1_1.TaskService See the Redfish standard schema and specification for information on common Status object.
Tasks
This property references a resource of type Collection with a MemberType of TaskCollection.
Tasks is a link ("@odata.id": URI
) to another resource.
TelemetryService
@odata.type: "#TelemetryService.v1_0_0.TelemetryService"
The TelemetryService resource describes the Metrics Service.
Telemetry not supported on AMD platforms
Telemetry Service is supported only on Intel platform. On AMD systems, performing GET
on /redfish/v1/TelemetryService
will return 400 Error Operation not supported.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
MetricReports |
Collection of MetricReport |
MetricReportDefinitions |
Collection of MetricDefinition |
Triggers |
Collection of Triggers |
MaxReports
Member of TelemetryService.v1_0_0.TelemetryService
Description | The maximum number of metric reports supported by this service. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
MetricDefinitions
A link to the collection of Metric Definitions.
MetricDefinitions is a link ("@odata.id": URI
) to another resource.
MetricReportDefinitions
A link to the collection of Metric Reports.
MetricReportDefinitions is a link ("@odata.id": URI
) to another resource.
MetricReports
A link to the collection of Metric Reports.
MetricReports is a link ("@odata.id": URI
) to another resource.
MinCollectionInterval
Member of TelemetryService.v1_0_0.TelemetryService
Description | The minimum time interval between collections supported by this service. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Status
Member of TelemetryService.v1_0_0.TelemetryService See the Redfish standard schema and specification for information on common Status object.
SupportedCollectionFunctions (array)
Member of TelemetryService.v1_0_0.TelemetryService
SupportedCollectionFunctions
is an array containing elements of:
SupportedCollectionFunctions[{item}] Member of TelemetryService.v1_0_0.TelemetryService
Description | An operation to perform over the sample. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Average |
An averaging function. |
Maximum |
A maximum function. |
Minimum |
A minimum function. |
Summation |
A summation function. |
Triggers
A link to the collection of Triggers, which apply to metrics.
Triggers is a link ("@odata.id": URI
) to another resource.
Thermal
@odata.type: "#Thermal.v1_7_1.Thermal"
The Thermal resource describes the system thermal metrics. It represents the properties for temperature and cooling.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/thermal |
GET PATCH |
Fans (array)
Member of Thermal.v1_7_1.Thermal
Fans
is an array containing elements of:
Fans[{item}].@odata.id Member of Thermal.v1_7_1.Thermal
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Fans[{item}].CorrelatableID Member of Thermal.v1_7_1.Thermal
Description | The CorrelatableID for this fan. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].LowerThresholdCritical Member of Thermal.v1_7_1.Thermal
Description | Below normal range but not yet fatal. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].LowerThresholdFatal Member of Thermal.v1_7_1.Thermal
Description | Below normal range and is fatal. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].LowerThresholdNonCritical Member of Thermal.v1_7_1.Thermal
Description | Below normal range. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].MaximumValue Member of Thermal.v1_7_1.Thermal
Description | Maximum value for CurrentReading. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].MemberId Member of Thermal.v1_7_1.Thermal
Description | This is the identifier for the member within the collection. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].MinimumValue Member of Thermal.v1_7_1.Thermal
Description | Minimum value for CurrentReading. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].Oem.Hpe.HotPluggable Member of Thermal.v1_7_1.Thermal
Description | Indicates if the fan can be replaced while server is running. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].Oem.Hpe.IsLiquidCooling Member of Thermal.v1_7_1.Thermal
Description | Indicates that the device is Liquid cooling device or not. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].Oem.Hpe.Location Member of Thermal.v1_7_1.Thermal
Description | Indicates the component (i.e. CPU, Memory, and Storage) that the fan is being used to cool. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
System |
System Board |
I/O Board |
CPU |
Memory |
Storage |
Removable Media |
Power Supply |
Ambient |
Chassis |
Bridge Board |
Exhaust |
Processor Bay |
IO Bay |
Blade Slot |
Virtual |
Fans[{item}].Oem.Hpe.Redundant Member of Thermal.v1_7_1.Thermal
Description | Indicates if the fan is in a redundant configuration. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].PhysicalContext Member of Thermal.v1_7_1.Thermal
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Room |
The room |
Intake |
The intake point of the chassis |
Exhaust |
The exhaust point of the chassis |
Front |
The front of the chassis |
Back |
The back of the chassis |
Upper |
The upper portion of the chassis |
Lower |
The lower portion of the chassis |
CPU |
A Processor (CPU) |
GPU |
A Graphics Processor (GPU) |
Backplane |
A backplane within the chassis |
SystemBoard |
The system board (PCB) |
PowerSupply |
A power supply |
VoltageRegulator |
A voltage regulator device |
StorageDevice |
A storage device |
NetworkingDevice |
A networking device |
ComputeBay |
Within a compute bay |
StorageBay |
Within a storage bay |
NetworkBay |
Within a networking bay |
ExpansionBay |
Within an expansion bay |
PowerSupplyBay |
Within a power supply bay |
Fans[{item}].Reading Member of Thermal.v1_7_1.Thermal
Description | The current speed of the fan. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].ReadingUnits Member of Thermal.v1_7_1.Thermal
Description | Units for the CurrentReading. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value |
---|
Null |
Percent |
Fans[{item}].Status Member of Thermal.v1_7_1.Thermal See the Redfish standard schema and specification for information on common Status object.
Fans[{item}].UpperThresholdCritical Member of Thermal.v1_7_1.Thermal
Description | Above normal range but not yet fatal. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].UpperThresholdFatal Member of Thermal.v1_7_1.Thermal
Description | Above normal range and is fatal. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Fans[{item}].UpperThresholdNonCritical Member of Thermal.v1_7_1.Thermal
Description | Above normal range. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.FanPercentAdjust
Member of Thermal.v1_7_1.Thermal
Description | System-wide setting for fan +/- percentage adjustment. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.FanPercentMinimum
Member of Thermal.v1_7_1.Thermal
Description | System-wide setting for fan speed minimum percentage. |
Type | integer |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.ThermalConfiguration
Member of Thermal.v1_7_1.Thermal
Description | The value of this property selects the fan cooling method for the system. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
OptimalCooling |
Provides the most efficient solution by configuring fan speeds to the minimum required to provide adequate cooling |
IncreasedCooling |
Operates fans at a higher speed. |
MaximumCooling |
Provides the maximum cooling available for the system. |
EnhancedCooling |
Provides additional cooling to the processors, which can improve performance. |
AcousticMode |
Edgeline-only option. Prioritizes minimizing noise from the enclosure. |
Status
Member of Thermal.v1_7_1.Thermal See the Redfish standard schema and specification for information on common Status object.
Temperatures (array)
Member of Thermal.v1_7_1.Thermal
Temperatures
is an array containing elements of:
Temperatures[{item}].@odata.id Member of Thermal.v1_7_1.Thermal
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Temperatures[{item}].CorrelatableID Member of Thermal.v1_7_1.Thermal
Description | The CorrelatableID for this temperature sensor. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].LowerThresholdCritical Member of Thermal.v1_7_1.Thermal
Description | Below normal range but not yet fatal. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].LowerThresholdFatal Member of Thermal.v1_7_1.Thermal
Description | Below normal range and is fatal. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].LowerThresholdNonCritical Member of Thermal.v1_7_1.Thermal
Description | Below normal range. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].MaximumValue Member of Thermal.v1_7_1.Thermal
Description | Maximum value for CurrentReading. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].MemberId Member of Thermal.v1_7_1.Thermal
Description | This is the identifier for the member within the collection. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].MinimumValue Member of Thermal.v1_7_1.Thermal
Description | Minimum value for CurrentReading. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].Oem.Hpe.CriticalTempUserThreshold Member of Thermal.v1_7_1.Thermal
Description | User provided temperature threshold value for the sensor that results in a critical alert. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].Oem.Hpe.LocationXmm Member of Thermal.v1_7_1.Thermal
Description | The location of the sensor, in millimeters, along the X axis from the logical reference point. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].Oem.Hpe.LocationYmm Member of Thermal.v1_7_1.Thermal
Description | The location of the sensor, in millimeters, along the Y axis from the logical reference point. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].Oem.Hpe.LocationZmm Member of Thermal.v1_7_1.Thermal
Description | The location of the sensor, in millimeters, along the Z axis from the logical reference point. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].Oem.Hpe.MainSensorName Member of Thermal.v1_7_1.Thermal
Description | Sensor name of main temperature sensor that has atleast one sub sensor |
Type | string |
Read Only | True |
Added | iLO6 1.20 |
Temperatures[{item}].Oem.Hpe.WarningTempUserThreshold Member of Thermal.v1_7_1.Thermal
Description | User provided temperature threshold value for the sensor that results in a warning alert. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].PhysicalContext Member of Thermal.v1_7_1.Thermal
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Room |
The room. |
Intake |
The air intake point or points or region of the chassis. |
Exhaust |
The air exhaust point or points or region of the chassis. |
LiquidInlet |
The liquid inlet point of the chassis. |
LiquidOutlet |
The liquid outlet point of the chassis. |
Front |
The front of the chassis. |
Back |
The back of the chassis. |
Upper |
The upper portion of the chassis. |
Lower |
The lower portion of the chassis. |
CPU |
A processor (CPU). |
CPUSubsystem |
The entire processor (CPU) subsystem. |
GPU |
A graphics processor (GPU). |
GPUSubsystem |
The entire graphics processor (GPU) subsystem. |
FPGA |
An FPGA. |
Accelerator |
An accelerator. |
ASIC |
An ASIC device, such as a networking chip or chipset component. |
Backplane |
A backplane within the chassis. |
SystemBoard |
The system board (PCB). |
PowerSupply |
A power supply. |
PowerSubsystem |
The entire power subsystem. |
VoltageRegulator |
A voltage regulator device. |
Rectifier |
A rectifier device. |
StorageDevice |
A storage device. |
NetworkingDevice |
A networking device. |
ComputeBay |
Within a compute bay. |
StorageBay |
Within a storage bay. |
NetworkBay |
Within a networking bay. |
ExpansionBay |
Within an expansion bay. |
PowerSupplyBay |
Within a power supply bay. |
Memory |
A memory device. |
MemorySubsystem |
The entire memory subsystem. |
Chassis |
The entire chassis. |
Fan |
A fan. |
CoolingSubsystem |
The entire cooling, or air and liquid, subsystem. |
Motor |
A motor. |
Transformer |
A transformer. |
ACUtilityInput |
An AC utility input. |
ACStaticBypassInput |
An AC static bypass input. |
ACMaintenanceBypassInput |
An AC maintenance bypass input. |
DCBus |
A DC bus. |
ACOutput |
An AC output. |
ACInput |
An AC input. |
TrustedModule |
A trusted module. |
Board |
A circuit board. |
Transceiver |
A transceiver. |
Battery |
A battery. |
Pump |
A pump. |
Temperatures[{item}].ReadingCelsius Member of Thermal.v1_7_1.Thermal
Description | The current reading of the temperature sensor. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].SensorNumber Member of Thermal.v1_7_1.Thermal
Description | A numerical identifier to represent the temperature sensor. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].Status Member of Thermal.v1_7_1.Thermal See the Redfish standard schema and specification for information on common Status object.
Temperatures[{item}].UpperThresholdCritical Member of Thermal.v1_7_1.Thermal
Description | Above normal range but not yet fatal. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].UpperThresholdFatal Member of Thermal.v1_7_1.Thermal
Description | Above normal range and is fatal. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Temperatures[{item}].UpperThresholdNonCritical Member of Thermal.v1_7_1.Thermal
Description | The noncritical temperature threshold. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Actions
HpeThermalExt.SetUserTempThreshold Member of Thermal.v1_7_1.Thermal The action to set a user defined threshold for a PCIe slot temperature sensor.
Parameters:
AlertType (string)
Alert type thrown when user defined temperature threshold is exceeded.
Value | Description |
---|
|Warning|Generate a warning alert when user threshold exceeded.|
SensorNumber (integer)
Sensor number of the sensor to be monitored.
ThresholdValue (integer)
Temperature thershold that once passed will issue an alert.
ThermalMetrics
@odata.type: "#ThermalMetrics.v1_3_1.ThermalMetrics"
The ThermalMetrics schema represents the thermal metrics of a chassis.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/thermalsubsystem/thermalmetrics |
GET |
PowerWatts
PowerWatts.Reading Member of ThermalMetrics.v1_3_1.ThermalMetrics
Description | The sensor value |
Type | number or null |
Read Only | True |
Added | iLO6 1.63 |
TemperatureReadingsCelsius (array)
Member of ThermalMetrics.v1_3_1.ThermalMetrics
TemperatureReadingsCelsius
is an array containing elements of:
TemperatureReadingsCelsius[{item}].DeviceName Member of ThermalMetrics.v1_3_1.ThermalMetrics
Description | The name of the device. |
Type | string or null |
Read Only | True |
Added | iLO6 1.63 |
TemperatureReadingsCelsius[{item}].PhysicalContext Member of ThermalMetrics.v1_3_1.ThermalMetrics
Description | Describes the area or device to which this voltage measurement applies. |
Type | string or null |
Read Only | True |
Added | iLO6 1.63 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
Room |
The room |
Intake |
The intake point of the chassis |
Exhaust |
The exhaust point of the chassis |
Front |
The front of the chassis |
Back |
The back of the chassis |
Upper |
The upper portion of the chassis |
Lower |
The lower portion of the chassis |
CPU |
A Processor (CPU) |
GPU |
A Graphics Processor (GPU) |
Backplane |
A backplane within the chassis |
SystemBoard |
The system board (PCB) |
PowerSupply |
A power supply |
VoltageRegulator |
A voltage regulator device |
StorageDevice |
A storage device |
NetworkingDevice |
A networking device |
ComputeBay |
Within a compute bay |
StorageBay |
Within a storage bay |
NetworkBay |
Within a networking bay |
ExpansionBay |
Within an expansion bay |
PowerSupplyBay |
Within a power supply bay |
TemperatureReadingsCelsius[{item}].Reading Member of ThermalMetrics.v1_3_1.ThermalMetrics
Description | The sensor value. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.63 |
TemperatureReadingsCelsius@odata.count
Member of ThermalMetrics.v1_3_1.ThermalMetrics
Description | The number of items in a collection. |
Type | integer |
Read Only | True |
Added | iLO6 1.63 |
TemperatureSummaryCelsius
TemperatureSummaryCelsius.Ambient TemperatureSummaryCelsius.Ambient.DataSourceUri Member of ThermalMetrics.v1_3_1.ThermalMetrics
Description | The link to the resource that provides the data for this sensor. |
Type | string or null |
Read Only | True |
Added | iLO6 1.63 |
TemperatureSummaryCelsius.Ambient.Reading Member of ThermalMetrics.v1_3_1.ThermalMetrics
Description | The sensor value |
Type | integer or null |
Read Only | True |
Added | iLO6 1.63 |
ThermalSubsystem
@odata.type: "#ThermalSubsystem.v1_3_2.ThermalSubsystem"
This ThermalSubsystem schema contains the definition for the thermal subsystem of a chassis.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/chassis/{item}/thermalsubsystem |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Fans |
Collection of Fan |
Fans
The link to the summary of Fan Collection for this subsystem.
Fans is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.FanPercentAdjust
Member of ThermalSubsystem.v1_3_2.ThermalSubsystem
Description | System-wide setting for fan +/- percentage adjustment. |
Type | integer |
Read Only | False |
Added | iLO6 1.63 |
Oem.Hpe.FanPercentMinimum
Member of ThermalSubsystem.v1_3_2.ThermalSubsystem
Description | System-wide setting for fan speed minimum percentage. |
Type | integer |
Read Only | False |
Added | iLO6 1.63 |
Oem.Hpe.ThermalConfiguration
Member of ThermalSubsystem.v1_3_2.ThermalSubsystem
Description | The value of this property selects the fan cooling method for the system. |
Type | string |
Read Only | False |
Added | iLO6 1.63 |
The following are the supported values:
Value | Description |
---|---|
OptimalCooling |
Provides the most efficient solution by configuring fan speeds to the minimum required to provide adequate cooling |
IncreasedCooling |
Operates fans at a higher speed. |
MaximumCooling |
Provides the maximum cooling available for the system. |
EnhancedCooling |
Provides additional cooling to the processors, which can improve performance. |
AcousticMode |
Edgeline-only option. Prioritizes minimizing noise from the enclosure. |
Pumps
A link to the pumps for this equipment.
Pumps is a link ("@odata.id": URI
) to another resource.
ThermalMetrics
The link to the summary of thermal metrics for this subsystem.
ThermalMetrics is a link ("@odata.id": URI
) to another resource.
Triggers
@odata.type: "#Triggers.v1_0_0.Triggers"
The Triggers resource describes the a metric trigger, which apply to metrics.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/triggers/{item} |
GET PATCH |
MetricProperties (array)
Member of Triggers.v1_0_0.Triggers
MetricProperties
is an array containing elements of:
MetricProperties[{item}] Member of Triggers.v1_0_0.Triggers
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
MetricType
Member of Triggers.v1_0_0.Triggers
Description | Specifies the type of metric for which the trigger is configured. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Numeric |
The trigger is for numeric sensor. |
Discrete |
The trigger is for a discrete sensor. |
NumericThresholds
NumericThresholds.LowerCritical NumericThresholds.LowerCritical.Activation Member of Triggers.v1_0_0.Triggers
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
NumericThresholds.LowerCritical.DwellTime Member of Triggers.v1_0_0.Triggers
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
NumericThresholds.LowerCritical.Reading Member of Triggers.v1_0_0.Triggers
Description | The threshold value. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
NumericThresholds.LowerWarning NumericThresholds.LowerWarning.Activation Member of Triggers.v1_0_0.Triggers
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
NumericThresholds.LowerWarning.DwellTime Member of Triggers.v1_0_0.Triggers
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
NumericThresholds.LowerWarning.Reading Member of Triggers.v1_0_0.Triggers
Description | The threshold value. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
NumericThresholds.UpperCritical NumericThresholds.UpperCritical.Activation Member of Triggers.v1_0_0.Triggers
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
NumericThresholds.UpperCritical.DwellTime Member of Triggers.v1_0_0.Triggers
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
NumericThresholds.UpperCritical.Reading Member of Triggers.v1_0_0.Triggers
Description | The threshold value. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
NumericThresholds.UpperWarning NumericThresholds.UpperWarning.Activation Member of Triggers.v1_0_0.Triggers
Description | The direction of crossing that activates this threshold. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Increasing |
Value increases above the threshold. |
Decreasing |
Value decreases below the threshold. |
Either |
Value crosses the threshold in either direction. |
NumericThresholds.UpperWarning.DwellTime Member of Triggers.v1_0_0.Triggers
Description | The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
NumericThresholds.UpperWarning.Reading Member of Triggers.v1_0_0.Triggers
Description | The threshold value. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Status
Member of Triggers.v1_0_0.Triggers See the Redfish standard schema and specification for information on common Status object.
TriggerActions (array)
Member of Triggers.v1_0_0.Triggers
TriggerActions
is an array containing elements of:
TriggerActions[{item}] Member of Triggers.v1_0_0.Triggers
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
LogToLogService |
Upon a trigger, record in a log. |
RedfishEvent |
Upon a trigger, send a Redfish Event message of type MetricReport. |
TriggersCollection
@odata.type: "#TriggersCollection.TriggersCollection"
A Collection of Triggers resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/telemetryservice/triggers |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
Triggers |
Members (array)
Member of TriggersCollection.TriggersCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of TriggersCollection.TriggersCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of TriggersCollection.TriggersCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |
UpdateService
@odata.type: "#UpdateService.v1_2_1.UpdateService"
The UpdateService resource describes the Update Service. It represents the properties for the service itself and has links to collections of firmware and software inventory.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/updateservice |
GET PATCH |
Links to other Resources
Link Name | Destination type |
---|---|
Oem/Hpe/InstallSets |
Collection of HpeComponentInstallSet |
Oem/Hpe/ComponentRepository |
Collection of HpeComponent |
FirmwareInventory |
Collection of SoftwareInventory |
SoftwareInventory |
Collection of SoftwareInventory |
Oem/Hpe/UpdateTaskQueue |
Collection of HpeComponentUpdateTask |
FirmwareInventory
Link to Firmware Inventory.
FirmwareInventory is a link ("@odata.id": URI
) to another resource.
HttpPushUri
Member of UpdateService.v1_2_1.UpdateService
Description | The URI to which a client may POST an update image. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Oem.Hpe.Accept3rdPartyFirmware
Member of UpdateService.v1_2_1.UpdateService
Description | Enable or disable support for 3rd party firmware update packages. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.BundleUpdateReport
Link to the Bundle Update report.
BundleUpdateReport is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.Capabilities
Oem.Hpe.Capabilities.BundleDowngradeSupport Member of UpdateService.v1_2_1.UpdateService
Description | Indicates whether iLO supports downgrade capability for cloud based updates. |
Type | boolean |
Read Only | True |
Added | iLO6 1.10 |
Oem.Hpe.Capabilities.COMBootToUefiShellSupport Member of UpdateService.v1_2_1.UpdateService
Description | Indicates whether iLO supports booting to Uefi shell for cloud based updates. |
Type | boolean |
Read Only | True |
Added | iLO6 1.40 |
Oem.Hpe.Capabilities.COMVCSupport Member of UpdateService.v1_2_1.UpdateService
Description | Indicates whether iLO supports pending reset for bundle update. |
Type | boolean |
Read Only | True |
Added | iLO6 1.40 |
Oem.Hpe.Capabilities.HostPoweroffSupport Member of UpdateService.v1_2_1.UpdateService
Description | Indicates whether iLO supports HOST power off. |
Type | boolean |
Read Only | True |
Added | iLO6 1.56 |
Oem.Hpe.Capabilities.OfflineRuntimeBundleUpdate Member of UpdateService.v1_2_1.UpdateService
Description | Indicates whether iLO supports offline type D installation. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
ProductionMode |
iLO supports offline type D installation in production security state only. |
ProductionAndHighSecurityMode |
iLO supports offline type D installation in Production and High security state only. |
AllModes |
iLO supports offline type D installation in all security states viz, Production, High security, FIPS and CNSA. |
Oem.Hpe.Capabilities.PLDMFirmwareUpdate Member of UpdateService.v1_2_1.UpdateService
Description | Indicates whether iLO supports PLDM firmware updates. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Capabilities.UpdateFWPKG Member of UpdateService.v1_2_1.UpdateService
Description | Indicates whether iLO supports FWPKG 2.0 firmware images. |
Type | boolean |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.ComponentRepository
Link to the Component Repository.
ComponentRepository is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.CurrentTime
Member of UpdateService.v1_2_1.UpdateService
Description | ISO 8601 Redfish-style time string of the current iLO time (the reference for all scheduling) |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Oem.Hpe.DowngradePolicy
Member of UpdateService.v1_2_1.UpdateService
Description | Can be used to restrict the firmware downgrade. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
AllowDowngrade |
Downgrading firmware is allowed. |
RecoveryDowngrade |
Downgrading firmware is allowed by a user with the Recovery Set privilege. |
NoDowngrade |
Downgrading firmware is not allowed. This is a permanent setting and cannot be undone. |
Oem.Hpe.FirmwareIntegrity
Oem.Hpe.FirmwareIntegrity.EnableBackgroundScan Member of UpdateService.v1_2_1.UpdateService
Description | Enables or disables background scan of critical firmware. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.FirmwareIntegrity.LastFailedImageUri Member of UpdateService.v1_2_1.UpdateService
Description | This is a link to the binary image of the firmware that failed an integrity check and is intended for diagnostic purposes. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Oem.Hpe.FirmwareIntegrity.LastScanResult Member of UpdateService.v1_2_1.UpdateService
Description | The firmware integrity scan engine status. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
OK |
The last firmware integrity scan completed without finding any issues. |
Repaired |
The last firmware integrity scan successfully repaired an issue. Refer to the event log for details. |
Failure |
The last firmware integrity scan failed to complete or repair an issue. Refer to the event log for details. |
Stopped |
The last firmware integrity scan was stopped prior to completion. Refer to the event log for details. |
Oem.Hpe.FirmwareIntegrity.LastScanTime Member of UpdateService.v1_2_1.UpdateService
Description | The time stamp of the last firmware integrity scan. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Format | date-time |
Oem.Hpe.FirmwareIntegrity.OnIntegrityFailure Member of UpdateService.v1_2_1.UpdateService
Description | Sets the policy for how the firmware integrity check handles integrity failures. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
LogOnly |
Log failures to the iLO event log but do not automatically attempt to repair. |
LogAndRepairAutomatically |
Log failures to the iLO event log and automatically attempt to repair. |
Oem.Hpe.FirmwareIntegrity.ScanEveryDays Member of UpdateService.v1_2_1.UpdateService
Description | Sets the interval between firmware integrity scans in 24 hour increments. |
Type | integer or null |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.FlashProgressPercent
Member of UpdateService.v1_2_1.UpdateService
Description | This is the percent complete for an iLO flash operation. It is only valid when State is Updating. |
Type | integer or null |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.InstallSets
Link to the Install Sets collection.
InstallSets is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.InvalidImageRepository
Link to the Invalid Image Repository.
InvalidImageRepository is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.MaintenanceWindows
Link to the Maintenance Windows.
MaintenanceWindows is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.Result
Oem.Hpe.Result.MessageArgs (array) Member of UpdateService.v1_2_1.UpdateService
MessageArgs
is an array containing elements of:
MessageArgs[{item}] Member of UpdateService.v1_2_1.UpdateService
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Oem.Hpe.Result.MessageId Member of UpdateService.v1_2_1.UpdateService
Description | The key for this message that can be used to look up the message in a message registry. |
Type | string |
Read Only | False |
Added | iLO6 1.05 |
Oem.Hpe.State
Member of UpdateService.v1_2_1.UpdateService
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Idle |
The update service is idle. |
Uploading |
The update service is receiving a new component. |
Verifying |
The update service is verifying the integrity of a new component. |
Writing |
The update service is writing a new component to the iLO Repository. |
Updating |
The update service is updating (flashing) firmware. |
Complete |
The update service has completed up upload or update operation. |
Error |
The upload service encountered an error. See Result for detail. |
Oem.Hpe.UpdateTaskQueue
Link to the Update Task Queue.
UpdateTaskQueue is a link ("@odata.id": URI
) to another resource.
Oem.Hpe.UploadCurrentEtag
Member of UpdateService.v1_2_1.UpdateService
Description | client-supplied etag (during component upload) indicating to what UploadStatus is reporting upon. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
ServiceEnabled
Member of UpdateService.v1_2_1.UpdateService
Description | Indicates if the Update Service is enabled. |
Type | boolean or null |
Read Only | True |
Added | iLO6 1.05 |
SoftwareInventory
Link to Software Inventory. This is only available when the Agentless Management Service is running.
SoftwareInventory is a link ("@odata.id": URI
) to another resource.
Actions
UpdateService.SimpleUpdate Member of UpdateService.v1_2_1.UpdateService
Parameters:
Username (string)
The username credential required for authentication to fetch image.
TransferProtocol (string)
Value | Description |
---|---|
HTTP | Hypertext Transfer Protocol |
HTTPS | HTTP Secure protocol |
ImageURI (string)
Password (string)
The password credential required for authentication to fetch image.
Targets (array)
Target Redfish URI
HpeiLOUpdateServiceExt.DeleteInstallSets Member of UpdateService.v1_2_1.UpdateService
Parameters:
IncludeRecoverySet (boolean)
HpeiLOUpdateServiceExt.DeleteUnlockedComponents Member of UpdateService.v1_2_1.UpdateService There are no parameters for this action.
HpeiLOUpdateServiceExt.DeleteMaintenanceWindows Member of UpdateService.v1_2_1.UpdateService There are no parameters for this action.
HpeiLOUpdateServiceExt.AddFromUri Member of UpdateService.v1_2_1.UpdateService
Parameters:
UpdateTarget (boolean)
If true the action will flash the target.
UpdateRecoverySet (boolean)
If true the action will update the system recovery set if it contains a matching target after the repository is updated.
UploadCurrentEtag (string)
client-supplied etag (during component upload) indicating to what UploadStatus is reporting upon.
VirtualMedia
@odata.type: "#VirtualMedia.v1_3_0.VirtualMedia"
The VirtualMedia resource describes the BMC virtual media feature.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/virtualmedia/{item} |
GET PATCH |
ConnectedVia
Member of VirtualMedia.v1_3_0.VirtualMedia
Description | Specifies how the virtual media is connected to the server. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
Null |
A value is temporarily unavailable |
NotConnected |
No current connection. |
URI |
Connected to a URI location. |
Applet |
Connected to a client application. |
Image
Member of VirtualMedia.v1_3_0.VirtualMedia
Description | The valid URI indicating the image that is mounted on this server. A null value indicates that no image exists. |
Type | string or null |
Read Only | False |
Added | iLO6 1.05 |
Format | uri-reference |
ImageName
Member of VirtualMedia.v1_3_0.VirtualMedia
Description | The name of the image that is mounted on this server. This is usually provided when a URL image is mounted through scripted virtual media. |
Type | string or null |
Read Only | True |
Added | iLO6 1.05 |
Inserted
Member of VirtualMedia.v1_3_0.VirtualMedia
Description | Indicates whether the virtual media is mounted on the server. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
MediaTypes (array)
Member of VirtualMedia.v1_3_0.VirtualMedia
MediaTypes
is an array containing elements of:
MediaTypes[{item}] Member of VirtualMedia.v1_3_0.VirtualMedia
Description | The array of supported media types for this connection. |
Type | string |
Read Only | True |
Added | iLO6 1.05 |
The following are the supported values:
Value | Description |
---|---|
CD |
A CD-ROM format (ISO) image. |
Floppy |
A floppy disk image. |
USBStick |
An emulation of a USB storage device. |
DVD |
A DVD-ROM format image. |
Oem.Hpe.BootOnNextServerReset
Member of VirtualMedia.v1_3_0.VirtualMedia
Description | If set to true, the server will boot to this image on the next server reboot. The image will be ejected automatically on the second server reboot so that the server does not boot to this image twice. |
Type | boolean |
Read Only | False |
Added | iLO6 1.05 |
TransferProtocolType
Member of VirtualMedia.v1_3_0.VirtualMedia
Description | Network Protocol to use with the image |
Type | string |
Read Only | True |
Added | iLO6 1.10 |
The following are the supported values:
Value | Description |
---|---|
CIFS |
Common Internet File System protocol. |
FTP |
File Transfer Protocol. |
SFTP |
Secure File Transfer Protocol. |
HTTP |
Hypertext Transfer Protocol. |
HTTPS |
HTTP Secure protocol. |
NFS |
Network File System protocol. |
SCP |
Secure File Copy protocol. |
TFTP |
Trivial File Transfer Protocol. |
OEM |
A protocol defined by the manufacturer. |
WriteProtected
Member of VirtualMedia.v1_3_0.VirtualMedia
Description | Indicates whether the virtual media is protected against write operations. |
Type | boolean or null |
Read Only | False |
Added | iLO6 1.05 |
Actions
VirtualMedia.InsertMedia Member of VirtualMedia.v1_3_0.VirtualMedia
Parameters:
TransferProtocolType (string)
Network Protocol to use with the image
Value | Description |
---|---|
FTP | File Transfer Protocol. |
HTTP | Hypertext Transfer Protocol. |
CIFS | Common Internet File System protocol. |
HTTPS | HTTP Secure protocol. |
SFTP | Secure File Transfer Protocol. |
NFS | Network File System protocol. |
OEM | A protocol defined by the manufacturer. |
TFTP | Trivial File Transfer Protocol. |
SCP | Secure File Copy protocol. |
Image (string)
The URI of the remote media to attach to the virtual media.
WriteProtected (boolean)
Indicates whether the virtual media is protected against write operations. If this parameter is not provided by the client, the service shall default this value to be true.
Inserted (boolean)
Indicates if the image is to be treated as inserted upon completion of the action. If this parameter is not provided by the client, the service shall default this value to be true.
VirtualMedia.EjectMedia Member of VirtualMedia.v1_3_0.VirtualMedia There are no parameters for this action.
HpeiLOVirtualMedia.InsertVirtualMedia Member of VirtualMedia.v1_3_0.VirtualMedia
Parameters:
Certificate (string)
A PEM encoded X509 certificate used to validate the https server.
Image (string)
A URL for an ISO, BIN, or IMG file locating the virtual media image.
Intent (string)
A text description of the reason for this action invocation.
Signature (string)
A RSA2048 SHA-256 signature validating the provided Intent (Base64 encoded).
WriteProtected (boolean)
Indicates whether the virtual media is protected against write operations.
HpeiLOVirtualMedia.EjectVirtualMedia Member of VirtualMedia.v1_3_0.VirtualMedia
Parameters:
Intent (string)
A text description of the reason for this action invocation.
Signature (string)
A RSA2048 SHA-256 signature validating the provided Intent (Base64 encoded).
VirtualMediaCollection
@odata.type: "#VirtualMediaCollection.VirtualMediaCollection"
A Collection of VirtualMedia resource instances.
Resource Instances
Uri | HTTP Allow |
---|---|
/redfish/v1/managers/{item}/virtualmedia |
GET |
Links to other Resources
Link Name | Destination type |
---|---|
Members[] |
VirtualMedia |
Members (array)
Member of VirtualMediaCollection.VirtualMediaCollection
Members
is an array containing elements of:
Members[{item}].@odata.id Member of VirtualMediaCollection.VirtualMediaCollection
Type | string |
Read Only | True |
Added | iLO6 1.05 |
Format | uri-reference |
Members@odata.count
Member of VirtualMediaCollection.VirtualMediaCollection
Description | The total number of collection members. |
Type | integer |
Read Only | True |
Added | iLO6 1.05 |