Other resource definitions of iLO 6 v1.64

For each data type provided by the HPE ilO Redfish service, find below its description including the list of possible instances (URIs), links to related other resources, described properties and many other details.

Refer to the data types and collection section for more information on Redfish data types and collections.

AccountService

@odata.type: "#AccountService.v1_15_0.AccountService"

The AccountService resource describes the BMC user account management service. It represents the properties for this service and has links to the list of accounts.

Managing User Accounts with the Accounts Collection

JSONPath: /Accounts/@odata.id

The destination of this link is a collection of user accounts (see ManagerAccount).

  • You may create a new user account by POSTing a new account description the the Accounts collection. See ManagerAccount for details.

    e.g. POST https://{iLO}/redfish/v1/accountservice/accounts/ with new account description

  • You may modify an existing user by PATCHing properties to the user account resource. See ManagerAccount for details.

    e.g. PATCH https://{iLO}/redfish/v1/accountservice/accounts/{item} with different properties

  • You may remove a user account by DELETEing the resources representing the user

    e.g. DELETE https://{iLO}/redfish/v1/accountservice/accounts/{item}

Resource Instances

Uri HTTP Allow
/redfish/v1/accountservice GET PATCH

Links to other Resources

Link Name Destination type
Accounts Collection of ManagerAccount

AccountLockoutCounterResetAfter

Member of AccountService.v1_15_0.AccountService

Description The interval of time in seconds between the last failed login attempt and reset of the lockout threshold counter. This value must be less than or equal to AccountLockoutDuration. Reset sets the counter to zero.
Type integer
Read Only True
Added iLO6 1.05

AccountLockoutCounterResetEnabled

Member of AccountService.v1_15_0.AccountService

Description The value indicates whether the threshold counter will be reset after AccountLockoutCounterResetAfter expires.
Type boolean
Read Only True
Added iLO6 1.05

AccountLockoutDuration

Member of AccountService.v1_15_0.AccountService

Description The time in seconds an account is locked out. The value must be greater than or equal to the value of the AccountLockoutCounterResetAfter property. If set to 0, no lockout occurs.
Type integer or null
Read Only False
Added iLO6 1.05

AccountLockoutThreshold

Member of AccountService.v1_15_0.AccountService

Description The number of failed login attempts allowed before a user account is locked for a specified duration. A value of 0 means it is never locked.
Type integer or null
Read Only False
Added iLO6 1.05

Accounts

This property references a resource of type Collection with a MemberType of ManagerAccount. Accounts is a link ("@odata.id": URI) to another resource.

ActiveDirectory

ActiveDirectory.AccountProviderType Member of AccountService.v1_15_0.AccountService

Description This property contains the type of external account provider this resource references.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
ActiveDirectoryService An external Active Directory Service.

ActiveDirectory.Authentication ActiveDirectory.Authentication.AuthenticationType Member of AccountService.v1_15_0.AccountService

Description This property contains the type of authentication used to connect to the external account provider.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
UsernameAndPassword Username and password combination.

ActiveDirectory.Authentication.Password Member of AccountService.v1_15_0.AccountService

Description This property is used with a PATCH or PUT to write the password for the account service. This property is null on a GET.
Type string or null
Read Only False
Added iLO6 1.05

ActiveDirectory.Authentication.Username Member of AccountService.v1_15_0.AccountService

Description This property contains the distinguished name for the account service.
Type string or null
Read Only False
Added iLO6 1.05

ActiveDirectory.RemoteRoleMapping (array) Member of AccountService.v1_15_0.AccountService

RemoteRoleMapping is an array containing elements of:

RemoteRoleMapping[{item}].LocalRole Member of AccountService.v1_15_0.AccountService

Description The name of the local role in which to map the remote user or group.
Type string or null
Read Only False
Added iLO6 1.05

RemoteRoleMapping[{item}].RemoteGroup Member of AccountService.v1_15_0.AccountService

Description This property is the name of the remote group (or in the case of a Redfish Service, remote role) that will be mapped to the local role referenced by this entity.
Type string or null
Read Only False
Added iLO6 1.05

ActiveDirectory.ServiceAddresses (array) Member of AccountService.v1_15_0.AccountService

ServiceAddresses is an array containing elements of:

ServiceAddresses[{item}] Member of AccountService.v1_15_0.AccountService

Type string or null
Read Only True
Added iLO6 1.05

ActiveDirectory.ServiceEnabled Member of AccountService.v1_15_0.AccountService

Description This indicates whether this service is enabled.
Type boolean or null
Read Only False
Added iLO6 1.05

AuthFailureLoggingThreshold

Member of AccountService.v1_15_0.AccountService

Description The number of authorization failures allowed before the failure attempt is logged to the manager log.
Type integer
Read Only False
Added iLO6 1.05

HTTPBasicAuth

Member of AccountService.v1_15_0.AccountService

Description Indicates if HTTP Basic authentication is enabled for this service.
Type string
Read Only False
Added iLO6 1.62

The following are the supported values:

Value Description
Enabled HTTP Basic authentication is enabled.
Unadvertised HTTP Basic authentication is enabled, but is not advertised with the WWW-Authenticate response header.
Disabled HTTP Basic authentication is disabled.

LDAP

LDAP.AccountProviderType Member of AccountService.v1_15_0.AccountService

Description This property contains the type of external account provider this resource references.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
ActiveDirectoryService An external Active Directory Service.
LDAPService A generic external LDAP Service.

LDAP.Authentication LDAP.Authentication.AuthenticationType Member of AccountService.v1_15_0.AccountService

Description This property contains the type of authentication used to connect to the external account provider.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
UsernameAndPassword Username and password combination.

LDAP.Authentication.Password Member of AccountService.v1_15_0.AccountService

Description This property is used with a PATCH or PUT to write the password for the account service. This property is null on a GET.
Type string or null
Read Only False
Added iLO6 1.05

LDAP.Authentication.Username Member of AccountService.v1_15_0.AccountService

Description This property contains the distinguished name for the account service.
Type string or null
Read Only False
Added iLO6 1.05

LDAP.Certificates A link to a collection of Certificates used for the external account service. Certificates is a link ("@odata.id": URI) to another resource.

LDAP.LDAPService LDAP.LDAPService.SearchSettings LDAP.LDAPService.SearchSettings.BaseDistinguishedNames (array) Member of AccountService.v1_15_0.AccountService

BaseDistinguishedNames is an array containing elements of:

BaseDistinguishedNames[{item}] Member of AccountService.v1_15_0.AccountService

Type string or null
Read Only True
Added iLO6 1.05

LDAP.RemoteRoleMapping (array) Member of AccountService.v1_15_0.AccountService

RemoteRoleMapping is an array containing elements of:

RemoteRoleMapping[{item}].LocalRole Member of AccountService.v1_15_0.AccountService

Description The name of the local role in which to map the remote user or group.
Type string or null
Read Only False
Added iLO6 1.05

RemoteRoleMapping[{item}].RemoteGroup Member of AccountService.v1_15_0.AccountService

Description This property is the name of the remote group (or in the case of a Redfish Service, remote role) that will be mapped to the local role referenced by this entity.
Type string or null
Read Only False
Added iLO6 1.05

LDAP.ServiceAddresses (array) Member of AccountService.v1_15_0.AccountService

ServiceAddresses is an array containing elements of:

ServiceAddresses[{item}] Member of AccountService.v1_15_0.AccountService

Type string or null
Read Only True
Added iLO6 1.05

LDAP.ServiceEnabled Member of AccountService.v1_15_0.AccountService

Description This indicates whether this service is enabled.
Type boolean or null
Read Only False
Added iLO6 1.05

LocalAccountAuth

Member of AccountService.v1_15_0.AccountService

Description Controls when this service will use the accounts defined withing this AccountService as part of authentication.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
Enabled Authentication via accounts defined in this AccountService is enabled.
Disabled Authentication via accounts defined in this AccountService is disabled.

MaxPasswordLength

Member of AccountService.v1_15_0.AccountService

Description The maximum password length for this service.
Type integer
Read Only True
Added iLO6 1.05

MinPasswordLength

Member of AccountService.v1_15_0.AccountService

Description The minimum password length for this account service.
Type integer
Read Only True
Added iLO6 1.05

Oem.Hpe.AuthFailureDelayTimeSeconds

Member of AccountService.v1_15_0.AccountService

Description The time in seconds to delay for each failure after AuthFailuresBeforeDelay authentication attempts have failed. Values of 2, 5, 10, and 30 seconds are valid.
Type integer
Read Only False
Added iLO6 1.05

The following are the supported values:

Value
2
5
10
30

Oem.Hpe.AuthFailureLoggingThreshold

Member of AccountService.v1_15_0.AccountService

Description This property enables you to view and configure logging criteria for failed authentications. A failed login log entry is recorded after the configured number of attempts. 0 = feature disabled; 1-3 and 5 are allowable values.
Type integer
Read Only False
Added iLO6 1.05

The following are the supported values:

Value
Null
1
2
3
5

Oem.Hpe.AuthFailuresBeforeDelay

Member of AccountService.v1_15_0.AccountService

Description The number of failed authentication attempts allowed before authentication is delayed by AuthFailureDelayTimeSeconds. Values of 0, 1, 3, and 5 are valid, with 0 indicating delay after every authentication failure.
Type integer
Read Only False
Added iLO6 1.05

The following are the supported values:

Value
Null
1
3
5

Oem.Hpe.DefaultPassword

Member of AccountService.v1_15_0.AccountService

Description The default password used to log in to the management processor when factory reset is performed.
Type string or null
Read Only False
Added iLO6 1.05

Oem.Hpe.DefaultUserName

Member of AccountService.v1_15_0.AccountService

Description The default name used to log in to the management processor when factory reset is performed.
Type string or null
Read Only False
Added iLO6 1.05

Oem.Hpe.DirectorySettings

Oem.Hpe.DirectorySettings.LdapAuthenticationMode Member of AccountService.v1_15_0.AccountService

Description Represents the LDAP authentication mode.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
Disabled Directory authentication is disabled.
DefaultSchema Directory Default schema or Schema-free option is selected.
ExtendedSchema HPE Extended schema is selected.

Oem.Hpe.DirectorySettings.LdapCaCertificateLoaded Member of AccountService.v1_15_0.AccountService

Description Represents if the directory server CA certificate is loaded or not.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.DirectorySettings.LdapCaCertificates A link to a collection of Certificates. LdapCaCertificates is a link ("@odata.id": URI) to another resource.

Oem.Hpe.DirectorySettings.LdapServerPort Member of AccountService.v1_15_0.AccountService

Description Represents the port number of the directory server.
Type integer
Read Only True
Added iLO6 1.05

Oem.Hpe.DirectoryTest

The value of this property shall be a reference to a resource of type HpeDirectoryTest. DirectoryTest is a link ("@odata.id": URI) to another resource.

Oem.Hpe.EnforcePasswordComplexity

Member of AccountService.v1_15_0.AccountService

Description Enforce complexity rules when a user password is set or changed. Three of four character classes must be present; ASCII UPPERCASE, LOWERCASE, DIGITS, and Other
Type boolean
Read Only False
Added iLO6 1.05

Oem.Hpe.KerberosSettings

Oem.Hpe.KerberosSettings.KDCServerPort Member of AccountService.v1_15_0.AccountService

Description Represents the port number of the KDC server.
Type integer
Read Only True
Added iLO6 1.05

Oem.Hpe.KerberosSettings.KerberosRealm Member of AccountService.v1_15_0.AccountService

Description Represents the Realm of the KDC server.
Type string or null
Read Only False
Added iLO6 1.05

Oem.Hpe.MinPasswordLength

Member of AccountService.v1_15_0.AccountService

Description This property specifies the minimum number of characters allowed when a user password is set or changed. It must be a value from 0 to 39.
Type integer
Read Only False
Added iLO6 1.05

Oem.Hpe.TwoFactorAuth

Member of AccountService.v1_15_0.AccountService

Description This property indicates two factor authentication enabled or not
Type string
Read Only False
Added iLO6 1.50

The following are the supported values:

Value
Enabled
Disabled

Roles

A link to a collection of Roles. Roles is a link ("@odata.id": URI) to another resource.

Actions

HpeiLOAccountService.ImportKerberosKeytab Member of AccountService.v1_15_0.AccountService Import the Kerberos keytab file.

Parameters:

ImportUri (string)

URI of the kerberos keytab file.

Assembly

@odata.type: "#Assembly.v1_5_0.Assembly"

The Assembly schema defines an assembly.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/thermalsubsystem/fans/{item}/assembly GET
/redfish/v1/chassis/{item}/thermalsubsystem/pumps/{item}/assembly GET

Assemblies (array)

Member of Assembly.v1_5_0.Assembly

Assemblies is an array containing elements of:

Assemblies[{item}].@odata.id Member of Assembly.v1_5_0.Assembly

Type string
Read Only True
Added iLO6 1.63
Format uri-reference

Assemblies[{item}].MemberId Member of Assembly.v1_5_0.Assembly

Description The unique identifier for the member within an array.
Type string
Read Only True
Added iLO6 1.63

Assemblies[{item}].PhysicalContext Member of Assembly.v1_5_0.Assembly

Description The area or device to which the assembly data applies.
Type string or null
Read Only True
Added iLO6 1.63

The following are the supported values:

Value Description
Null A value is temporarily unavailable
Room The room
Intake The intake point of the chassis
Exhaust The exhaust point of the chassis
Front The front of the chassis
Back The back of the chassis
Upper The upper portion of the chassis
Lower The lower portion of the chassis
CPU A Processor (CPU)
GPU A Graphics Processor (GPU)
Backplane A backplane within the chassis
SystemBoard The system board (PCB)
PowerSupply A power supply
VoltageRegulator A voltage regulator device
StorageDevice A storage device
NetworkingDevice A networking device
ComputeBay Within a compute bay
StorageBay Within a storage bay
NetworkBay Within a networking bay
ExpansionBay Within an expansion bay
PowerSupplyBay Within a power supply bay

Assemblies[{item}].Status Member of Assembly.v1_5_0.Assembly See the Redfish standard schema and specification for information on common Status object.

BootOption

@odata.type: "#BootOption.v1_0_1.BootOption"

This is the schema definition for the BootOption resource. It represents the properties of a bootable device available in the System.

Resource Instances

Uri HTTP Allow
/redfish/v1/systems/{item}/bootoptions/{item} GET

Alias

Member of BootOption.v1_0_1.BootOption

Description The alias of this Boot Source.
Type string or null
Read Only True
Added iLO6 1.05

BootOptionEnabled

Member of BootOption.v1_0_1.BootOption

Description A flag that shows if the Boot Option is enabled.
Type boolean or null
Read Only False
Added iLO6 1.05

BootOptionReference

Member of BootOption.v1_0_1.BootOption

Description The unique boot option string that is referenced in the BootOrder.
Type string or null
Read Only True
Added iLO6 1.05

DisplayName

Member of BootOption.v1_0_1.BootOption

Description The user-readable display string of the Boot Option.
Type string or null
Read Only True
Added iLO6 1.05

UefiDevicePath

Member of BootOption.v1_0_1.BootOption

Description The UEFI device path used to access this UEFI Boot Option.
Type string or null
Read Only True
Added iLO6 1.05

BootOptionCollection

@odata.type: "#BootOptionCollection.BootOptionCollection"

A Collection of BootOption resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/systems/{item}/bootoptions GET

Links to other Resources

Link Name Destination type
Members[] BootOption

Members (array)

Member of BootOptionCollection.BootOptionCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of BootOptionCollection.BootOptionCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of BootOptionCollection.BootOptionCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

Certificate

@odata.type: "#Certificate.v1_6_0.Certificate"

The Certificate resource describes an X509 certificate.

Resource Instances

Uri HTTP Allow
/redfish/v1/accountservice/externalaccountproviders/ldap/certificates/{item} GET PATCH DELETE
/redfish/v1/managers/{item}/securityservice/bmchpeldevid/certificates/{item} GET
/redfish/v1/managers/{item}/securityservice/bmciak/certificates/{item} GET
/redfish/v1/managers/{item}/securityservice/bmcidevidpca/certificates/{item} GET
/redfish/v1/managers/{item}/securityservice/bmclak/certificates/{item} GET
/redfish/v1/managers/{item}/securityservice/iloidevid/certificates/{item} GET
/redfish/v1/managers/{item}/securityservice/iloldevid/certificates/{item} GET DELETE
/redfish/v1/managers/{item}/securityservice/platformcert/certificates/{item} GET
/redfish/v1/managers/{item}/securityservice/systemiak/certificates/{item} GET
/redfish/v1/managers/{item}/securityservice/systemidevid/certificates/{item} GET
/redfish/v1/managers/{item}/securityservice/systemlak/certificates/{item} GET
/redfish/v1/managers/{item}/securityservice/systemldevid/certificates/{item} GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/db/certificates/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbdefault/certificates/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbr/certificates/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbrdefault/certificates/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbt/certificates/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbtdefault/certificates/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbx/certificates/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbxdefault/certificates/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kek/certificates/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kekdefault/certificates/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/pk/certificates/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/pkdefault/certificates/{item} GET DELETE

CertificateString

Member of Certificate.v1_6_0.Certificate

Description Contains PEM formatted X509 certificate or PKCS7 certificate chain (Base64 encoded).
Type string
Read Only False
Added iLO6 1.05
Format text

CertificateType

Member of Certificate.v1_6_0.Certificate

Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
PEM A PEM encoded certificate.
PKCS7 A PEM encoded PKCS7 certificate.

Issuer

Issuer.City Member of Certificate.v1_6_0.Certificate

Description The city or locality of the organization of the entity.
Type string
Read Only True
Added iLO6 1.10

Issuer.CommonName Member of Certificate.v1_6_0.Certificate

Description The fully qualified domain name of the entity.
Type string
Read Only True
Added iLO6 1.10

Issuer.Country Member of Certificate.v1_6_0.Certificate

Description The country of the organization of the entity.
Type string
Read Only True
Added iLO6 1.10

Issuer.DisplayString Member of Certificate.v1_6_0.Certificate

Description A human-readable string for this identifier.
Type string or null
Read Only True
Added iLO6 1.10

Issuer.Email Member of Certificate.v1_6_0.Certificate

Description The email address of the contact within the organization of the entity.
Type string or null
Read Only True
Added iLO6 1.10

Issuer.Organization Member of Certificate.v1_6_0.Certificate

Description The name of the organization of the entity.
Type string
Read Only True
Added iLO6 1.10

Issuer.OrganizationalUnit Member of Certificate.v1_6_0.Certificate

Description The name of the unit or division of the organization of the entity.
Type string
Read Only True
Added iLO6 1.10

Issuer.State Member of Certificate.v1_6_0.Certificate

Description The state, province, or region of the organization of the entity.
Type string
Read Only True
Added iLO6 1.10

SerialNumber

Member of Certificate.v1_6_0.Certificate

Description The serial number that the Certificate Authority assigned to the certificate.
Type string
Read Only True
Added iLO6 1.05

Subject

Subject.City Member of Certificate.v1_6_0.Certificate

Description The city or locality of the organization of the entity.
Type string
Read Only True
Added iLO6 1.10

Subject.CommonName Member of Certificate.v1_6_0.Certificate

Description The fully qualified domain name of the entity.
Type string
Read Only True
Added iLO6 1.10

Subject.Country Member of Certificate.v1_6_0.Certificate

Description The country of the organization of the entity.
Type string
Read Only True
Added iLO6 1.10

Subject.DisplayString Member of Certificate.v1_6_0.Certificate

Description A human-readable string for this identifier.
Type string or null
Read Only True
Added iLO6 1.10

Subject.Email Member of Certificate.v1_6_0.Certificate

Description The email address of the contact within the organization of the entity.
Type string or null
Read Only True
Added iLO6 1.10

Subject.Organization Member of Certificate.v1_6_0.Certificate

Description The name of the organization of the entity.
Type string
Read Only True
Added iLO6 1.10

Subject.OrganizationalUnit Member of Certificate.v1_6_0.Certificate

Description The name of the unit or division of the organization of the entity.
Type string
Read Only True
Added iLO6 1.10

Subject.State Member of Certificate.v1_6_0.Certificate

Description The state, province, or region of the organization of the entity.
Type string
Read Only True
Added iLO6 1.10

UefiSignatureOwner

Member of Certificate.v1_6_0.Certificate

Description The UEFI signature owner for this certificate.
Type string or null
Read Only True
Added iLO6 1.05

ValidNotAfter

Member of Certificate.v1_6_0.Certificate

Description The date on which the certificate validity period ends.
Type string or null
Read Only True
Added iLO6 1.05
Format date-time

ValidNotBefore

Member of Certificate.v1_6_0.Certificate

Description The date on which the certificate validity period begins.
Type string or null
Read Only True
Added iLO6 1.05
Format date-time

CertificateCollection

@odata.type: "#CertificateCollection.CertificateCollection"

A Collection of Certificate resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/accountservice/externalaccountproviders/ldap/certificates GET POST
/redfish/v1/managers/{item}/securityservice/bmchpeldevid/certificates GET
/redfish/v1/managers/{item}/securityservice/bmciak/certificates GET
/redfish/v1/managers/{item}/securityservice/bmcidevidpca/certificates GET
/redfish/v1/managers/{item}/securityservice/bmclak/certificates GET
/redfish/v1/managers/{item}/securityservice/iloidevid/certificates GET
/redfish/v1/managers/{item}/securityservice/iloldevid/certificates GET POST
/redfish/v1/managers/{item}/securityservice/platformcert/certificates GET
/redfish/v1/managers/{item}/securityservice/systemiak/certificates GET
/redfish/v1/managers/{item}/securityservice/systemidevid/certificates GET
/redfish/v1/managers/{item}/securityservice/systemlak/certificates GET
/redfish/v1/managers/{item}/securityservice/systemldevid/certificates GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/db/certificates GET POST
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbdefault/certificates GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbr/certificates GET POST
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbrdefault/certificates GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbt/certificates GET POST
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbtdefault/certificates GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbx/certificates GET POST
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbxdefault/certificates GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kek/certificates GET POST
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kekdefault/certificates GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/pk/certificates GET POST
/redfish/v1/systems/{item}/secureboot/securebootdatabases/pkdefault/certificates GET

Links to other Resources

Link Name Destination type
Members[] Certificate

Members (array)

Member of CertificateCollection.CertificateCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of CertificateCollection.CertificateCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of CertificateCollection.CertificateCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

CertificateLocations

@odata.type: "#CertificateLocations.v1_0_2.CertificateLocations"

The CertificateLocations schema describes a Resource that an administrator can use in order to locate all certificates installed on a given service.

Resource Instances

Uri HTTP Allow
/redfish/v1/certificateservice/certificatelocations GET

CertificateService

@odata.type: "#CertificateService.v1_0_3.CertificateService"

The CertificateService schema describes a certificate service that represents the actions available to manage certificates and links to the certificates.

Resource Instances

Uri HTTP Allow
/redfish/v1/certificateservice GET

Links to other Resources

Link Name Destination type
Links/CertificateLocations CertificateLocations

CertificateLocations

The information about the location of certificates. CertificateLocations is a link ("@odata.id": URI) to another resource.

Actions

CertificateService.GenerateCSR Member of CertificateService.v1_0_3.CertificateService

Parameters:

City (string)

The city or locality of the organization making the request.

GivenName (string)

The given name of the user making the request.

KeyPairAlgorithm (string)

The type of key-pair for use with signing algorithms.

CertificateCollection (object)

The link to the certificate collection where the certificate is installed after the certificate authority (CA) signs the certificate.

Country (string)

The two-letter country code of the organization making the request.

KeyCurveId (string)

The curve ID to use with the key, if needed based on the KeyPairAlgorithm parameter value.

CommonName (string)

The fully qualified domain name of the component to secure.

State (string)

The state, province, or region of the organization making the request.

ContactPerson (string)

The name of the user making the request.

Email (string)

The email address of the contact within the organization making the request.

Surname (string)

The surname of the user making the request.

KeyUsage (array)

The usage of the key contained in the certificate.

UnstructuredName (string)

The unstructured name of the subject.

KeyBitLength (integer)

The length of the key, in bits, if needed based on the KeyPairAlgorithm parameter value.

Organization (string)

The name of the organization making the request.

AlternativeNames (array)

The additional host names of the component to secure.

ChallengePassword (string)

The challenge password to apply to the certificate for revocation requests.

OrganizationalUnit (string)

The name of the unit or division of the organization making the request.

Initials (string)

The initials of the user making the request.

ComponentIntegrity

@odata.type: "#ComponentIntegrity.v1_2_3.ComponentIntegrity"

The ComponentIntegrity resource provides critical and pertinent security information about a specific device, system, software element, or other managed entity.

Resource Instances

Uri HTTP Allow
/redfish/v1/ComponentIntegrity/{item} GET POST

ComponentIntegrityEnabled

Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Description An indication of whether security protocols are enabled for the component.
Type boolean
Read Only False
Added iLO6 1.10

ComponentIntegrityType

Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Type string
Read Only True
Added iLO6 1.10

The following are the supported values:

Value Description
SPDM Security Protocol and Data Model (SPDM) protocol.
TPM Trusted Platform Module (TPM).
OEM OEM-specific.

ComponentIntegrityTypeVersion

Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Description The version of the security technology.
Type string
Read Only True
Added iLO6 1.10

Oem.Hpe.ExtendedVerificationStatus

Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Description Extended Verification Status of the Host Processor Module.
Type string or null
Read Only True
Added iLO6 1.61

The following are the supported values:

Value Description
NotValidated Host Processor Moduleis not validated yet, HPM is in factory Mode/HPM auth key slot not yet populated
Success Host Processor Module authentication successful.
Failed Host Processor Module authentication Failed.
Error Host Processor Module authentication internal error occured. Please retry.
CertificateCheckFailed Host Processor Module authentication Certificate check failed.

SPDM

SPDM.IdentityAuthentication SPDM.IdentityAuthentication.ResponderAuthentication SPDM.IdentityAuthentication.ResponderAuthentication.VerificationStatus Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Description The status of the verification of the identity of the component.
Type string or null
Read Only True
Added iLO6 1.10

The following are the supported values:

Value Description
Success Successful verification.
Failed Unsuccessful verification.

SPDM.MeasurementSet SPDM.MeasurementSet.MeasurementSpecification Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Type string
Read Only True
Added iLO6 1.45

The following are the supported values:

Value Description
DMTF DMTF.

SPDM.MeasurementSet.Measurements (array) Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Measurements is an array containing elements of:

Measurements[{item}].LastUpdated Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Description The date and time when information for the measurement was last updated.
Type string or null
Read Only True
Added iLO6 1.40
Format date-time

Measurements[{item}].Measurement Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Description The measurement data.
Type string or null
Read Only True
Added iLO6 1.40

Measurements[{item}].MeasurementHashAlgorithm Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Description The hash algorithm used to compute the measurement.
Type string or null
Read Only True
Added iLO6 1.40

Measurements[{item}].MeasurementIndex Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Description The index of the measurement.
Type integer or null
Read Only True
Added iLO6 1.45

Measurements[{item}].MeasurementType Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Type string or null
Read Only True
Added iLO6 1.45

The following are the supported values:

Value Description
ImmutableROM Immutable ROM.
MutableFirmware Mutable firmware or any mutable code.
HardwareConfiguration Hardware configuration, such as straps.
FirmwareConfiguration Firmware configuration, such as configurable firmware policy.
MutableFirmwareVersion Mutable firmware version.
MutableFirmwareSecurityVersionNumber Mutable firmware security version number.
MeasurementManifest Measurement Manifest.

Measurements[{item}].SecurityVersionNumber Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Description The security version number the measurement represents.
Type string or null
Read Only True
Added iLO6 1.45

SPDM.Requester The link to the the component that is reporting the integrity information of the target component. Requester is a link ("@odata.id": URI) to another resource.

Status

Member of ComponentIntegrity.v1_2_3.ComponentIntegrity See the Redfish standard schema and specification for information on common Status object.

TPM

TPM.ComponentCommunication TPM.ComponentCommunication.Sessions (array) Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Sessions is an array containing elements of:

Sessions[{item}].SessionId Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Description The identifier for an active session or communication channel between two components.
Type integer or null
Read Only True
Added iLO6 1.40

Sessions[{item}].SessionType Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Type string
Read Only True
Added iLO6 1.40

The following are the supported values:

Value Description
Plain A plain text session without any protection.
EncryptedAuthenticated An established session where both encryption and authentication are protecting the communication.
AuthenticatedOnly An established session where only authentication is protecting the communication.

TPM.MeasurementSet TPM.MeasurementSet.Measurements (array) Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Measurements is an array containing elements of:

Measurements[{item}].LastUpdated Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Description The date and time when information for the measurement was last updated.
Type string or null
Read Only True
Added iLO6 1.40
Format date-time

Measurements[{item}].Measurement Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Description The measurement data.
Type string or null
Read Only True
Added iLO6 1.40

Measurements[{item}].MeasurementHashAlgorithm Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Description The hash algorithm used to compute the measurement.
Type string or null
Read Only True
Added iLO6 1.40

Measurements[{item}].PCR Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Description The Platform Configuration Register (PCR) bank of the measurement.
Type integer or null
Read Only True
Added iLO6 1.40

TPM.NonceSizeBytesMaximum Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Description The maximum number of bytes that can be specified in the Nonce parameter of the TPMGetSignedMeasurements action.
Type integer or null
Read Only True
Added iLO6 1.40

TargetComponentURI

Member of ComponentIntegrity.v1_2_3.ComponentIntegrity

Description The link to the the component whose integrity that this resource reports.
Type string
Read Only True
Added iLO6 1.10

Actions

ComponentIntegrity.TPMGetSignedMeasurements Member of ComponentIntegrity.v1_2_3.ComponentIntegrity This action gets the TPM Signed Measurements.

Parameters:

Nonce (string)

A set of bytes as a hex-encoded string that is signed with the measurements. The value should be unique.

title (string)

Friendly action name

target (string)

Link to invoke action

PCRSelection (string)

An object that identify the PCRs to sign.

ComponentIntegrity.SPDMGetSignedMeasurements Member of ComponentIntegrity.v1_2_3.ComponentIntegrity This action gets the SPDM Signed Measurements.

Parameters:

Nonce (string)

A set of bytes as a hex-encoded string that is signed with the measurements. The value should be unique.

target (string)

Link to invoke action

title (string)

Friendly action name

SlotId (integer)

The slot identifier for the certificate containing the private key to generate the signature over the measurements.

MeasurementIndices (array)

An array of indices that identify the measurement blocks to sign.

ComponentIntegrityCollection

@odata.type: "#ComponentIntegrityCollection.ComponentIntegrityCollection"

A Collection of ComponentIntegrity resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/ComponentIntegrity GET PATCH

Links to other Resources

Link Name Destination type
Members[] ComponentIntegrity

Members (array)

Member of ComponentIntegrityCollection.ComponentIntegrityCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of ComponentIntegrityCollection.ComponentIntegrityCollection

Type string
Read Only True
Added iLO6 1.10
Format uri-reference

Members@odata.count

Member of ComponentIntegrityCollection.ComponentIntegrityCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.10

EnvironmentMetrics

@odata.type: "#EnvironmentMetrics.v1_3_2.EnvironmentMetrics"

The EnvironmentMetrics schema represents the environmental metrics of a device.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/environmentmetrics GET
/redfish/v1/systems/{item}/processors/{item}/environmentmetrics GET

EnergyJoules

EnergyJoules.DataSourceUri Member of EnvironmentMetrics.v1_3_2.EnvironmentMetrics

Description The link to the resource that provides the data for this sensor.
Type string or null
Read Only True
Added iLO6 1.61

EnergyJoules.Reading Member of EnvironmentMetrics.v1_3_2.EnvironmentMetrics

Description The sensor value
Type number or null
Read Only True
Added iLO6 1.61

EventDestination

@odata.type: "#EventDestination.v1_13_0.EventDestination"

The EventDestination resource describes the target of an event subscription, including the types of events subscribed and context to provide to the target in the Event payload.

Resource Instances

Uri HTTP Allow
/redfish/v1/eventservice/subscriptions/{item} GET PATCH DELETE

Context

Member of EventDestination.v1_13_0.EventDestination

Description A client-supplied string that is stored with the listener destination subscription.
Type string
Read Only False
Added iLO6 1.05

Destination

Member of EventDestination.v1_13_0.EventDestination

Description The URI of the destination listener service.
Type string
Read Only False
Added iLO6 1.05
Format uri-reference

EventFormatType

Member of EventDestination.v1_13_0.EventDestination

Description The content types of the message that are sent to the EventDestination.
Type string or null
Read Only False
Added iLO6 1.51

The following are the supported values:

Value
Event
MetricReport

HttpHeaders (array)

Member of EventDestination.v1_13_0.EventDestination

HttpHeaders is an array containing elements of:

HttpHeaders[{item}]

MetricReportDefinitions (array)

Member of EventDestination.v1_13_0.EventDestination

MetricReportDefinitions is an array containing elements of:

MetricReportDefinitions[{item}].@odata.id Member of EventDestination.v1_13_0.EventDestination

Type string
Read Only True
Added iLO6 1.51
Format uri-reference

Oem.Hpe.DeliveryRetryAttempts

Member of EventDestination.v1_13_0.EventDestination

Description This is the number of attempts an event posting is retried before the subscription is terminated.
Type integer
Read Only False
Added iLO6 1.05

Oem.Hpe.DeliveryRetryIntervalInSeconds

Member of EventDestination.v1_13_0.EventDestination

Description This represents the number of seconds between retry attempts for sending any given Event
Type integer
Read Only False
Added iLO6 1.05

Oem.Hpe.MutualAuthenticationEnabled

Member of EventDestination.v1_13_0.EventDestination

Description This represents if the subscriber and iLO need to perform mutual authentication when an event is sent.
Type boolean
Read Only False
Added iLO6 1.05

Oem.Hpe.RequestedMaxEventsToQueue

Member of EventDestination.v1_13_0.EventDestination

Description This represents the number of events the service should queue.
Type integer
Read Only False
Added iLO6 1.05

Oem.Hpe.RetireOldEventInMinutes

Member of EventDestination.v1_13_0.EventDestination

Description This represents the number of minutes until an event is expired.
Type integer
Read Only False
Added iLO6 1.05

Protocol

Member of EventDestination.v1_13_0.EventDestination

Description The protocol type of the event connection.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
Redfish

RegistryPrefixes (array)

Member of EventDestination.v1_13_0.EventDestination

RegistryPrefixes is an array containing elements of:

RegistryPrefixes[{item}] Member of EventDestination.v1_13_0.EventDestination

Type string or null
Read Only True
Added iLO6 1.05

SubscriptionType

Member of EventDestination.v1_13_0.EventDestination

Description The subscription type for events.
Type string or null
Read Only True
Added iLO6 1.20

The following are the supported values:

Value
RedfishEvent

EventDestinationCollection

@odata.type: "#EventDestinationCollection.EventDestinationCollection"

A Collection of EventDestination resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/eventservice/subscriptions GET POST

Links to other Resources

Link Name Destination type
Members[] EventDestination

Members (array)

Member of EventDestinationCollection.EventDestinationCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of EventDestinationCollection.EventDestinationCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of EventDestinationCollection.EventDestinationCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

EventService

@odata.type: "#EventService.v1_7_2.EventService"

The EventService resource describes the Event Service. It represents the properties for the service itself and has links to the actual list of subscriptions.

Resource Instances

Uri HTTP Allow
/redfish/v1/eventservice GET

Links to other Resources

Link Name Destination type
Subscriptions Collection of EventDestination
Oem/Hpe/CACertificates Collection of HpeCertificate

DeliveryRetryAttempts

Member of EventService.v1_7_2.EventService

Description This is the number of attempts an event posting is retried before the subscription is terminated.
Type integer
Read Only False
Added iLO6 1.05

DeliveryRetryIntervalSeconds

Member of EventService.v1_7_2.EventService

Description This represents the number of seconds between retry attempts for sending any given Event
Type integer
Read Only False
Added iLO6 1.05

EventTypesForSubscription (array)

Member of EventService.v1_7_2.EventService

EventTypesForSubscription is an array containing elements of:

EventTypesForSubscription[{item}] Member of EventService.v1_7_2.EventService

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
StatusChange The status of this resource has changed
ResourceUpdated The value of this resource has been updated
ResourceAdded A resource has been added
ResourceRemoved A resource has been removed
Alert A condition exists which requires attention

Oem.Hpe.CACertificates

The value of this property shall be a reference to a Collection of HpeCertificate resources. CACertificates is a link ("@odata.id": URI) to another resource.

Oem.Hpe.RequestedMaxEventsToQueueDefault

Member of EventService.v1_7_2.EventService

Description This represents the default number of events the service should queue.
Type integer
Read Only True
Added iLO6 1.05

Oem.Hpe.RetireOldEventInMinutesDefault

Member of EventService.v1_7_2.EventService

Description This represents the default number of minutes until an event is expired.
Type integer
Read Only True
Added iLO6 1.05

Oem.Hpe.TTLCountDefault

Member of EventService.v1_7_2.EventService

Description The default number of TTLUnits until this listener destination subscription expires. It may be renewed prior to expire to reset the Time to Live counter. The value 999999 is reserved to mean a perpetual subscription.
Type integer
Read Only True
Added iLO6 1.05

Oem.Hpe.TTLUnitsDefault

Member of EventService.v1_7_2.EventService

Description The default time unit used to measure the subscription time of this listener destination. This is the units for TTLCount and is used to express the subscription lifetime of the listener destination.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
seconds Time to Live (TTL) in Seconds
minutes Time to Live (TTL) in Minutes
days Time to Live (TTL) in Days

RegistryPrefixes (array)

Member of EventService.v1_7_2.EventService

RegistryPrefixes is an array containing elements of:

RegistryPrefixes[{item}] Member of EventService.v1_7_2.EventService

Type string or null
Read Only True
Added iLO6 1.05

ServiceEnabled

Member of EventService.v1_7_2.EventService

Description This indicates whether this service is enabled.
Type boolean or null
Read Only True
Added iLO6 1.05

Status

Member of EventService.v1_7_2.EventService See the Redfish standard schema and specification for information on common Status object.

Subscriptions

This is a reference to a collection of ListenerDestination resources. Subscriptions is a link ("@odata.id": URI) to another resource.

Actions

EventService.SubmitTestEvent Member of EventService.v1_7_2.EventService

Parameters:

EventId (string)

Severity (string)

Value Description
OK
Warning
Critical

EventType (string)

Value Description
StatusChange
ResourceUpdated
ResourceAdded
ResourceRemoved
Alert

OriginOfCondition (string)

EventTimestamp (string)

MessageId (string)

Message (string)

MessageArgs (array)

HpeEventService.ClearAllSubscriptions Member of EventService.v1_7_2.EventService There are no parameters for this action.

HpeEventService.ImportCACertificate Member of EventService.v1_7_2.EventService Imports a Trusted CA Certificate

Parameters:

Certificate (string)

Contains PEM formatted X509 certificate or PKCS7 certificate chain (Base64 encoded).

Fabric

@odata.type: "#Fabric.v1_3_0.Fabric"

The Fabric schema represents a simple fabric consisting of one or more switches,

Resource Instances

Uri HTTP Allow
/redfish/v1/fabrics/{item} GET POST PATCH

Links to other Resources

Link Name Destination type
Members[] Collection of SwitchCollection

FabricType

Member of Fabric.v1_3_0.Fabric

Type string or null
Read Only True
Added iLO6 1.54

The following are the supported values:

Value Description
PCIe PCI Express.
AHCI Advanced Host Controller Interface (AHCI).
UHCI Universal Host Controller Interface (UHCI).
SAS Serial Attached SCSI.
SATA Serial AT Attachment.
USB Universal Serial Bus (USB).
NVMe Non-Volatile Memory Express (NVMe).
FC Fibre Channel.
iSCSI Internet SCSI.
FCoE Fibre Channel over Ethernet (FCoE).
FCP Fibre Channel Protocol for SCSI.
FICON FIbre CONnection (FICON).
NVMeOverFabrics NVMe over Fabrics.
SMB Server Message Block (SMB). Also known as the Common Internet File System (CIFS).
NFSv3 Network File System (NFS) version 3.
NFSv4 Network File System (NFS) version 4.
HTTP Hypertext Transport Protocol (HTTP).
HTTPS Hypertext Transfer Protocol Secure (HTTPS).
FTP File Transfer Protocol (FTP).
SFTP SSH File Transfer Protocol (SFTP).
iWARP Internet Wide Area RDMA Protocol (iWARP).
RoCE RDMA over Converged Ethernet Protocol.
RoCEv2 RDMA over Converged Ethernet Protocol Version 2.
I2C Inter-Integrated Circuit Bus.
TCP Transmission Control Protocol (TCP).
UDP User Datagram Protocol (UDP).
TFTP Trivial File Transfer Protocol (TFTP).
GenZ GenZ.
MultiProtocol Multiple Protocols.
InfiniBand InfiniBand.
Ethernet Ethernet.
NVLink NVLink.
OEM OEM-specific.
DisplayPort DisplayPort.
HDMI HDMI.
VGA VGA.
DVI DVI.
CXL Compute Express Link.

Switches

The collection of links to the switches that this fabric contains. Switches is a link ("@odata.id": URI) to another resource.

FabricCollection

@odata.type: "#FabricCollection.FabricCollection"

A Collection of Fabric Resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/fabrics GET

Links to other Resources

Link Name Destination type
Members[] Fabric

Members (array)

Member of FabricCollection.FabricCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of FabricCollection.FabricCollection

Type string
Read Only True
Added iLO6 1.54
Format uri-reference

Members@odata.count

Member of FabricCollection.FabricCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.54

Fan

@odata.type: "#Fan.v1_5_1.Fan"

The Fan schema describes a cooling fan unit for a computer system or similar devices contained within a chassis. It also describes the location, such as a slot, socket, or bay, where a unit can be installed, by populating a resource instance with an absent state if a unit is not present.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/thermalsubsystem/fans/{item} GET

Links to other Resources

Link Name Destination type
Assembly Assembly

Assembly

The link to the summary of assembly for this subsystem. Assembly is a link ("@odata.id": URI) to another resource.

HotPluggable

Member of Fan.v1_5_1.Fan

Description An indication of whether this device can be inserted or removed while the equipment is in operation.
Type boolean or null
Read Only True
Added iLO6 1.63

PhysicalContext

Member of Fan.v1_5_1.Fan

Description The area or device associated with this fan.
Type string or null
Read Only True
Added iLO6 1.63

The following are the supported values:

Value Description
Null A value is temporarily unavailable
Room The room
Intake The intake point of the chassis
Exhaust The exhaust point of the chassis
Front The front of the chassis
Back The back of the chassis
Upper The upper portion of the chassis
Lower The lower portion of the chassis
CPU A Processor (CPU)
GPU A Graphics Processor (GPU)
Backplane A backplane within the chassis
SystemBoard The system board (PCB)
PowerSupply A power supply
VoltageRegulator A voltage regulator device
StorageDevice A storage device
NetworkingDevice A networking device
ComputeBay Within a compute bay
StorageBay Within a storage bay
NetworkBay Within a networking bay
ExpansionBay Within an expansion bay
PowerSupplyBay Within a power supply bay

SpeedPercent

SpeedPercent.DataSourceUri Member of Fan.v1_5_1.Fan

Description The link to the resource that provides the data for this sensor.
Type string or null
Read Only True
Added iLO6 1.63

SpeedPercent.Reading Member of Fan.v1_5_1.Fan

Description The sensor value
Type number or null
Read Only True
Added iLO6 1.63

SpeedPercent.SpeedRPM Member of Fan.v1_5_1.Fan

Description The rotational speed.
Type number or null
Read Only True
Added iLO6 1.63

Status

Member of Fan.v1_5_1.Fan See the Redfish standard schema and specification for information on common Status object.

FanCollection

@odata.type: "#FanCollection.FanCollection"

The Collection of Fan resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/thermalsubsystem/fans GET

Links to other Resources

Link Name Destination type
Members[] Fan

Members (array)

Member of FanCollection.FanCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of FanCollection.FanCollection

Type string
Read Only True
Added iLO6 1.63
Format uri-reference

Members@odata.count

Member of FanCollection.FanCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.63

HostInterface

@odata.type: "#HostInterface.v1_1_1.HostInterface"

The HostInterface resource describes a Redfish Host Interface, which is a method of accessing the Redfish API from the host computer system.

Resource Instances

Uri HTTP Allow
/redfish/v1/managers/{item}/hostinterfaces/{item} GET PATCH

AuthenticationModes (array)

Member of HostInterface.v1_1_1.HostInterface

AuthenticationModes is an array containing elements of:

AuthenticationModes[{item}].AuthenticationMode Member of HostInterface.v1_1_1.HostInterface

Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
AuthNone Requests without any sort of authentication are allowed.
BasicAuth Requests using HTTP Basic Authentication are allowed.
RedfishSessionAuth Requests using Redfish Session Authentication are allowed.
OemAuth Requests using OEM authentication mechanisms are allowed.

ExternallyAccessible

Member of HostInterface.v1_1_1.HostInterface

Description This indicates whether this interface is accessible by external entities.
Type boolean or null
Read Only True
Added iLO6 1.05

FirmwareAuthEnabled

Member of HostInterface.v1_1_1.HostInterface

Description This indicates whether this firmware authentication is enabled for this interface.
Type boolean or null
Read Only False
Added iLO6 1.05

FirmwareAuthRoleId

Member of HostInterface.v1_1_1.HostInterface

Description This property contains the Role for firmware authentication on this interface.
Type string
Read Only False
Added iLO6 1.05

HostEthernetInterfaces

This is a reference to a collection of NICs that Computer Systems use for network communication with this Host Interface. HostEthernetInterfaces is a link ("@odata.id": URI) to another resource.

HostEthernetInterfaces property is not supported in iLO5.

HostInterfaceType

Member of HostInterface.v1_1_1.HostInterface

Description This indicates the Host Interface type for this interface.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
NetworkHostInterface This interface is a Network Host Interface.

InterfaceEnabled

Member of HostInterface.v1_1_1.HostInterface

Description This indicates whether this interface is enabled.
Type boolean
Read Only False
Added iLO6 1.05

KernelAuthEnabled

Member of HostInterface.v1_1_1.HostInterface

Description This indicates whether this kernel authentication is enabled for this interface.
Type boolean or null
Read Only False
Added iLO6 1.05

KernelAuthRoleId

Member of HostInterface.v1_1_1.HostInterface

Description This property contains the Role for kernel authentication on this interface.
Type string
Read Only False
Added iLO6 1.05

ManagerEthernetInterface

This is a reference to a single NIC that this Manager uses for network communication with this Host Interface. ManagerEthernetInterface is a link ("@odata.id": URI) to another resource.

NetworkProtocol

This is a reference to the network services and their settings that the Manager controls. It is here that clients will find network configuration options as well as network services. NetworkProtocol is a link ("@odata.id": URI) to another resource.

Status

Member of HostInterface.v1_1_1.HostInterface See the Redfish standard schema and specification for information on common Status object.

HostInterfaceCollection

@odata.type: "#HostInterfaceCollection.HostInterfaceCollection"

A Collection of HostInterface resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/managers/{item}/hostinterfaces GET

Links to other Resources

Link Name Destination type
Members[] HostInterface

Members (array)

Member of HostInterfaceCollection.HostInterfaceCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of HostInterfaceCollection.HostInterfaceCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of HostInterfaceCollection.HostInterfaceCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

JsonSchemaFile

@odata.type: "#JsonSchemaFile.v1_0_4.JsonSchemaFile"

The JSON Schema File resource describes the location (URI) of a particular Redfish schema definition being implemented or referenced by a Redfish service.

Resource Instances

Uri HTTP Allow
/redfish/v1/jsonschemas/{item} GET

Languages (array)

Member of JsonSchemaFile.v1_0_4.JsonSchemaFile

Languages is an array containing elements of:

Languages[{item}] Member of JsonSchemaFile.v1_0_4.JsonSchemaFile

Type string
Read Only True
Added iLO6 1.05

Location (array)

Member of JsonSchemaFile.v1_0_4.JsonSchemaFile

Location is an array containing elements of:

Location[{item}].Language Member of JsonSchemaFile.v1_0_4.JsonSchemaFile

Description The RFC 5646 language code for this schema or registry item.
Type string
Read Only True
Added iLO6 1.05

Location[{item}].Uri Member of JsonSchemaFile.v1_0_4.JsonSchemaFile

Description Link to locally available URI for schema.
Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Schema

Member of JsonSchemaFile.v1_0_4.JsonSchemaFile

Description The typename this schema describes.
Type string
Read Only True
Added iLO6 1.05

JsonSchemaFileCollection

@odata.type: "#JsonSchemaFileCollection.JsonSchemaFileCollection"

A Collection of JsonSchemaFile resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/jsonschemas GET

Links to other Resources

Link Name Destination type
Members[] JsonSchemaFile

Members (array)

Member of JsonSchemaFileCollection.JsonSchemaFileCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of JsonSchemaFileCollection.JsonSchemaFileCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of JsonSchemaFileCollection.JsonSchemaFileCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

Key

@odata.type: "#Key.v1_4_1.Key"

The Key schema describes sensitive data for accessing devices or services.

Resource Instances

Uri HTTP Allow
/redfish/v1/accountservice/accounts/{item}/keys/{item} GET PATCH DELETE

KeyString

Member of Key.v1_4_1.Key

Description The string for the key.
Type string or null
Read Only False
Added iLO6 1.63

KeyType

Member of Key.v1_4_1.Key

Type string
Read Only False
Added iLO6 1.63

The following are the supported values:

Value Description
NVMeoF An NVMe-oF key.
SSH An SSH public key.

SSH

SSH.Comment Member of Key.v1_4_1.Key

Description The user-specified comment associated with this key, which typically contains the client's username and host name.
Type string or null
Read Only True
Added iLO6 1.63

SSH.Fingerprint Member of Key.v1_4_1.Key

Description A fingerprint of the key.
Type string or null
Read Only True
Added iLO6 1.63

KeyCollection

@odata.type: "#KeyCollection.KeyCollection"

The collection of Key resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/accountservice/accounts/{item}/keys GET POST

Links to other Resources

Link Name Destination type
Members[] Key

Members (array)

Member of KeyCollection.KeyCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of KeyCollection.KeyCollection

Type string
Read Only True
Added iLO6 1.63
Format uri-reference

Members@odata.count

Member of KeyCollection.KeyCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.63

LogEntry

@odata.type: "#LogEntry.v1_11_0.LogEntry"

This resource defines the record format for a log. It is designed to be used for SEL logs (from IPMI) as well as Event Logs and OEM-specific log formats. The EntryType field indicates the type of log and the resource includes several additional properties dependent on the EntryType.

Resource Instances

Uri HTTP Allow
/redfish/v1/managers/{item}/logservices/iel/entries/{item} GET
/redfish/v1/managers/{item}/remotesupportservice/serviceeventlogs/{item} GET
/redfish/v1/systems/{item}/logservices/dpu/entries/{item} GET PATCH
/redfish/v1/systems/{item}/logservices/event/entries/{item} GET
/redfish/v1/systems/{item}/logservices/iml/entries/{item} GET PATCH
/redfish/v1/systems/{item}/logservices/sl/entries/{item} GET

Created

Member of LogEntry.v1_11_0.LogEntry

Description The date and time when the log entry was created, for example, 2014-04-15T00:38:00Z.
Type string
Read Only True
Added iLO6 1.05
Format date-time

EntryType

Member of LogEntry.v1_11_0.LogEntry

Description The log entry type.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
Oem

EventId

Member of LogEntry.v1_11_0.LogEntry

Description The unique instance identifier for an event.
Type string
Read Only True
Added iLO6 1.05

EventTimestamp

Member of LogEntry.v1_11_0.LogEntry

Description The date and time when the event occurred.
Type string
Read Only True
Added iLO6 1.05
Format date-time

Message

Member of LogEntry.v1_11_0.LogEntry

Description The log entry details.
Type string
Read Only True
Added iLO6 1.05

MessageArgs (array)

Member of LogEntry.v1_11_0.LogEntry

MessageArgs is an array containing elements of:

MessageArgs[{item}] Member of LogEntry.v1_11_0.LogEntry

Type string
Read Only True
Added iLO6 1.05

MessageId

Member of LogEntry.v1_11_0.LogEntry

Description The MessageId, event data, or OEM-specific information. This property decodes from the entry type. If the entry type is Event, this property contains a Redfish Specification-defined MessageId. If the entry type is SEL, this property contains the Event Data. Otherwise, this property contains OEM-specific information.
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.Categories (array)

Member of LogEntry.v1_11_0.LogEntry

Categories is an array containing elements of:

Categories[{item}] Member of LogEntry.v1_11_0.LogEntry

Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
Security
Hardware
Firmware
Maintenance
Administration
Power
Cooling
Invalid User Input
Other
Configuration

Oem.Hpe.Class

Member of LogEntry.v1_11_0.LogEntry

Description The log entry event class.
Type integer
Read Only True
Added iLO6 1.05

Oem.Hpe.ClassDescription

Member of LogEntry.v1_11_0.LogEntry

Description The log entry event class description.
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.Code

Member of LogEntry.v1_11_0.LogEntry

Description The log entry event code.
Type integer
Read Only True
Added iLO6 1.05

Oem.Hpe.Count

Member of LogEntry.v1_11_0.LogEntry

Description The occurrence count of the log entry.
Type integer
Read Only True
Added iLO6 1.05

Oem.Hpe.Destination

Member of LogEntry.v1_11_0.LogEntry

Description The destination host name or IP address of the remote server that recevied the service event.
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.EventNumber

Member of LogEntry.v1_11_0.LogEntry

Description The event log identification number. Events are numbered in the order in which they are generated.
Type integer
Read Only True
Added iLO6 1.05

Oem.Hpe.Identifier

Member of LogEntry.v1_11_0.LogEntry

Description The unique identifier of the service event.
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.LearnMoreLink

Member of LogEntry.v1_11_0.LogEntry

Description The link to troubleshooting information.
Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Oem.Hpe.RecommendedAction

Member of LogEntry.v1_11_0.LogEntry

Description The recommended action for the event.
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.Repaired

Member of LogEntry.v1_11_0.LogEntry

Description The repaired status of the IML event.
Type boolean
Read Only False
Added iLO6 1.05

Oem.Hpe.ServiceEvent

Member of LogEntry.v1_11_0.LogEntry

Description This indicates a service ticket to be raised for the corresponding event log.
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.ServiceEventMessageID

Member of LogEntry.v1_11_0.LogEntry

Description This property represents the Embedded Remote Support Message ID. It is applicable only for a Service Event log.
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.Severity

Member of LogEntry.v1_11_0.LogEntry

Description The log entry event Severity.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Informational Informational event
Caution Caution event
Critical Critical event
Repaired Critical or Caution event repaired

Oem.Hpe.SubmitStatus

Member of LogEntry.v1_11_0.LogEntry

Description The service event log submission status .
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.Updated

Member of LogEntry.v1_11_0.LogEntry

Description The date and time of the latest log entry update, for example, 2014-04-15T00:38:00Z.
Type string
Read Only True
Added iLO6 1.05
Format date-time

Oem.Hpe.UserAction

Member of LogEntry.v1_11_0.LogEntry

Description The User action for the event.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
Repaired The event repaired by user.
Ignored The event ignored by user.
None No user action taken on the event.
Not Applicable User action not applicable for the event.

OemRecordFormat

Member of LogEntry.v1_11_0.LogEntry

Description The format of an OEM record.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
Hpe-IML
Hpe-iLOEventLog
Hpe-SL
Hpe-Event

Severity

Member of LogEntry.v1_11_0.LogEntry

Description The log entry severity.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
OK
Warning
Critical

LogEntryCollection

@odata.type: "#LogEntryCollection.LogEntryCollection"

A Collection of LogEntry resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/managers/{item}/logservices/iel/entries GET POST
/redfish/v1/managers/{item}/remotesupportservice/serviceeventlogs GET
/redfish/v1/systems/{item}/logservices/dpu/entries GET POST
/redfish/v1/systems/{item}/logservices/event/entries GET POST
/redfish/v1/systems/{item}/logservices/iml/entries GET POST
/redfish/v1/systems/{item}/logservices/sl/entries GET POST

Links to other Resources

Link Name Destination type
Members[] LogEntry

Members (array)

Member of LogEntryCollection.LogEntryCollection

Members is an array containing elements of:

Members[{item}].@odata.context Member of LogEntryCollection.LogEntryCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members[{item}].@odata.etag Member of LogEntryCollection.LogEntryCollection

Type string
Read Only True
Added iLO6 1.05

Members[{item}].@odata.id Member of LogEntryCollection.LogEntryCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members[{item}].@odata.type Member of LogEntryCollection.LogEntryCollection

Type string
Read Only True
Added iLO6 1.05

Members[{item}].Created Member of LogEntryCollection.LogEntryCollection

Description The date and time when the log entry was created, for example, 2014-04-15T00:38:00Z.
Type string
Read Only True
Added iLO6 1.05
Format date-time

Members[{item}].EntryType Member of LogEntryCollection.LogEntryCollection

Description The log entry type.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
Oem

Members[{item}].EventId Member of LogEntryCollection.LogEntryCollection

Description The unique instance identifier for an event.
Type string
Read Only True
Added iLO6 1.05

Members[{item}].EventTimestamp Member of LogEntryCollection.LogEntryCollection

Description The date and time when the event occurred.
Type string
Read Only True
Added iLO6 1.05
Format date-time

Members[{item}].Links Members[{item}].Links.OriginOfCondition The link to the resource that caused the log entry. OriginOfCondition is a link ("@odata.id": URI) to another resource.

Members[{item}].Message Member of LogEntryCollection.LogEntryCollection

Description The log entry details.
Type string
Read Only True
Added iLO6 1.05

Members[{item}].MessageArgs (array) Member of LogEntryCollection.LogEntryCollection

MessageArgs is an array containing elements of:

MessageArgs[{item}] Member of LogEntryCollection.LogEntryCollection

Type string
Read Only True
Added iLO6 1.05

Members[{item}].MessageId Member of LogEntryCollection.LogEntryCollection

Description The MessageId, event data, or OEM-specific information. This property decodes from the entry type. If the entry type is Event, this property contains a Redfish Specification-defined MessageId. If the entry type is SEL, this property contains the Event Data. Otherwise, this property contains OEM-specific information.
Type string
Read Only True
Added iLO6 1.05

Members[{item}].Oem.Hpe.Categories (array) Member of LogEntryCollection.LogEntryCollection

Categories is an array containing elements of:

Categories[{item}] Member of LogEntryCollection.LogEntryCollection

Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
Security
Hardware
Firmware
Maintenance
Administration
Power
Cooling
Invalid User Input
Other
Configuration

Members[{item}].Oem.Hpe.Class Member of LogEntryCollection.LogEntryCollection

Description The log entry event class.
Type integer
Read Only True
Added iLO6 1.05

Members[{item}].Oem.Hpe.ClassDescription Member of LogEntryCollection.LogEntryCollection

Description The log entry event class description.
Type string
Read Only True
Added iLO6 1.05

Members[{item}].Oem.Hpe.Code Member of LogEntryCollection.LogEntryCollection

Description The log entry event code.
Type integer
Read Only True
Added iLO6 1.05

Members[{item}].Oem.Hpe.Count Member of LogEntryCollection.LogEntryCollection

Description The occurrence count of the log entry.
Type integer
Read Only True
Added iLO6 1.05

Members[{item}].Oem.Hpe.Destination Member of LogEntryCollection.LogEntryCollection

Description The destination host name or IP address of the remote server that recevied the service event.
Type string
Read Only True
Added iLO6 1.05

Members[{item}].Oem.Hpe.EventNumber Member of LogEntryCollection.LogEntryCollection

Description The event log identification number. Events are numbered in the order in which they are generated.
Type integer
Read Only True
Added iLO6 1.05

Members[{item}].Oem.Hpe.Identifier Member of LogEntryCollection.LogEntryCollection

Description The unique identifier of the service event.
Type string
Read Only True
Added iLO6 1.05

Members[{item}].Oem.Hpe.LearnMoreLink Member of LogEntryCollection.LogEntryCollection

Description The link to troubleshooting information.
Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members[{item}].Oem.Hpe.RecommendedAction Member of LogEntryCollection.LogEntryCollection

Description The recommended action for the event.
Type string
Read Only True
Added iLO6 1.05

Members[{item}].Oem.Hpe.Repaired Member of LogEntryCollection.LogEntryCollection

Description The repaired status of the IML event.
Type boolean
Read Only False
Added iLO6 1.05

Members[{item}].Oem.Hpe.ServiceEvent Member of LogEntryCollection.LogEntryCollection

Description This indicates a service ticket to be raised for the corresponding event log.
Type string
Read Only True
Added iLO6 1.05

Members[{item}].Oem.Hpe.ServiceEventMessageID Member of LogEntryCollection.LogEntryCollection

Description This property represents the Embedded Remote Support Message ID. It is applicable only for a Service Event log.
Type string
Read Only True
Added iLO6 1.05

Members[{item}].Oem.Hpe.Severity Member of LogEntryCollection.LogEntryCollection

Description The log entry event Severity.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Informational Informational event
Caution Caution event
Critical Critical event
Repaired Critical or Caution event repaired

Members[{item}].Oem.Hpe.SubmitStatus Member of LogEntryCollection.LogEntryCollection

Description The service event log submission status .
Type string
Read Only True
Added iLO6 1.05

Members[{item}].Oem.Hpe.Updated Member of LogEntryCollection.LogEntryCollection

Description The date and time of the latest log entry update, for example, 2014-04-15T00:38:00Z.
Type string
Read Only True
Added iLO6 1.05
Format date-time

Members[{item}].Oem.Hpe.UserAction Member of LogEntryCollection.LogEntryCollection

Description The User action for the event.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
Repaired The event repaired by user.
Ignored The event ignored by user.
None No user action taken on the event.
Not Applicable User action not applicable for the event.

Members[{item}].OemRecordFormat Member of LogEntryCollection.LogEntryCollection

Description The format of an OEM record.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
Hpe-IML
Hpe-iLOEventLog
Hpe-SL
Hpe-Event

Members[{item}].Severity Member of LogEntryCollection.LogEntryCollection

Description The log entry severity.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
OK
Warning
Critical

Members@odata.count

Member of LogEntryCollection.LogEntryCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

LogService

@odata.type: "#LogService.v1_1_0.LogService"

This resource contains properties for monitoring and configuring an event log service for the resource or service to which it is associated.

Resource Instances

Uri HTTP Allow
/redfish/v1/managers/{item}/logservices/iel GET
/redfish/v1/systems/{item}/logservices/dpu GET POST
/redfish/v1/systems/{item}/logservices/event GET
/redfish/v1/systems/{item}/logservices/iml GET
/redfish/v1/systems/{item}/logservices/sl GET

Links to other Resources

Link Name Destination type
Entries Collection of LogEntry

DateTime

Member of LogService.v1_1_0.LogService

Description The current date and time, with UTC offset, that the Log Service uses to set or read time.
Type string or null
Read Only True
Added iLO6 1.10
Format date-time

DateTimeLocalOffset

Member of LogService.v1_1_0.LogService

Description The UTC offset that the current DateTime property value contains in the +HH:MM format.
Type string or null
Read Only True
Added iLO6 1.10

Entries

The URI to this log entries collection resource. Entries is a link ("@odata.id": URI) to another resource.

MaxNumberOfRecords

Member of LogService.v1_1_0.LogService

Description The maximum number of log entries.
Type integer
Read Only True
Added iLO6 1.05

OverWritePolicy

Member of LogService.v1_1_0.LogService

Description When the log is full, the overwrite policy is enforced.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Unknown The overwrite policy is not known or is undefined.
WrapsWhenFull When the log is full, new entries will overwrite previous entries.
NeverOverwrites When the log is full, new entries are discarded.

ServiceEnabled

Member of LogService.v1_1_0.LogService

Description An indication of whether this service is enabled.
Type boolean
Read Only True
Added iLO6 1.10

Status

Member of LogService.v1_1_0.LogService See the Redfish standard schema and specification for information on common Status object.

Actions

LogService.ClearLog Member of LogService.v1_1_0.LogService There are no parameters for this action.

LogServiceCollection

@odata.type: "#LogServiceCollection.LogServiceCollection"

A Collection of LogService resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/managers/{item}/logservices GET
/redfish/v1/systems/{item}/logservices GET

Links to other Resources

Link Name Destination type
Members[] LogService

Members (array)

Member of LogServiceCollection.LogServiceCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of LogServiceCollection.LogServiceCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of LogServiceCollection.LogServiceCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

Memory

@odata.type: "#Memory.v1_14_0.Memory"

The Memory resource describes a memory module.

Resource Instances

Uri HTTP Allow
/redfish/v1/systems/{item}/memory/{item} GET

Links to other Resources

Link Name Destination type
Members[] MemoryMetrics

AllocationAlignmentMiB

Member of Memory.v1_14_0.Memory

Description The boundary which memory regions are allocated on, measured in MiB.
Type integer or null
Read Only True
Added iLO6 1.05

AllocationIncrementMiB

Member of Memory.v1_14_0.Memory

Description The size of the smallest unit of allocation for a memory region, thus it is the multiple in which regions are actually reserved.
Type integer or null
Read Only True
Added iLO6 1.05

BaseModuleType

Member of Memory.v1_14_0.Memory

Description The base module type of the memory.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
RDIMM Registered DIMM
UDIMM UDIMM
SO_DIMM SO_DIMM
LRDIMM Load Reduced
Mini_RDIMM Mini_RDIMM
Mini_UDIMM Mini_UDIMM
SO_RDIMM_72b SORDIMM72b
SO_UDIMM_72b SOUDIMM72b
SO_DIMM_16b SODIMM16b
SO_DIMM_32b SODIMM32b
Die A die within a package.

BusWidthBits

Member of Memory.v1_14_0.Memory

Description Bus Width in bits.
Type integer or null
Read Only True
Added iLO6 1.05

CacheSizeMiB

Member of Memory.v1_14_0.Memory

Description Total size of the cache portion memory in MiB.
Type integer or null
Read Only True
Added iLO6 1.05

CapacityMiB

Member of Memory.v1_14_0.Memory

Description Memory Capacity in MiB.
Type integer or null
Read Only True
Added iLO6 1.05

ConfigurationLocked

Member of Memory.v1_14_0.Memory

Description Indicates that the configuration of this memory has been locked
Type boolean or null
Read Only True
Added iLO6 1.05

DataWidthBits

Member of Memory.v1_14_0.Memory

Description Data Width in bits.
Type integer or null
Read Only True
Added iLO6 1.05

DeviceID

Member of Memory.v1_14_0.Memory

Description Device ID
Type string or null
Read Only True
Added iLO6 1.05

DeviceLocator

Member of Memory.v1_14_0.Memory

Description Location of the Memory in the platform
Type string or null
Read Only True
Added iLO6 1.05

ErrorCorrection

Member of Memory.v1_14_0.Memory

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
NoECC No ECC available
SingleBitECC Single bit Data error can be corrected by ECC
MultiBitECC Multi-bit Data errors can be corrected by ECC
AddressParity Address Parity errors can be corrected

FirmwareApiVersion

Member of Memory.v1_14_0.Memory

Description Version of API supported by the firmware
Type string or null
Read Only True
Added iLO6 1.05

FirmwareRevision

Member of Memory.v1_14_0.Memory

Description The firmware revision of this device
Type string or null
Read Only True
Added iLO6 1.05

LogicalSizeMiB

Member of Memory.v1_14_0.Memory

Description Total size of the logical memory in MiB.
Type integer or null
Read Only True
Added iLO6 1.05

Manufacturer

Member of Memory.v1_14_0.Memory

Description The Memory manufacturer
Type string or null
Read Only True
Added iLO6 1.05

MemoryDeviceType

Member of Memory.v1_14_0.Memory

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
DDR DDR
DDR2 DDR2
DDR3 DDR3
DDR4 DDR4
DDR4_SDRAM DDR4 SDRAM
DDR4E_SDRAM DDR4E SDRAM
LPDDR4_SDRAM LPDDR4 SDRAM
DDR3_SDRAM DDR3 SDRAM
LPDDR3_SDRAM LPDDR3 SDRAM
DDR2_SDRAM DDR2 SDRAM
DDR2_SDRAM_FB_DIMM DDR2 SDRAM FB_DIMM
DDR2_SDRAM_FB_DIMM_PROBE DDR2 SDRAM FB_DIMM PROBE
DDR_SGRAM DDR SGRAM
DDR_SDRAM DDR SDRAM
ROM ROM
SDRAM SDRAM
EDO EDO
FastPageMode Fast Page Mode
PipelinedNibble Pipelined Nibble
Logical Logical Non-volatile device.
DDR5 DDR5

MemoryLocation

MemoryLocation.Channel Member of Memory.v1_14_0.Memory

Description Channel number in which Memory is connected
Type integer or null
Read Only True
Added iLO6 1.05

MemoryLocation.MemoryController Member of Memory.v1_14_0.Memory

Description Memory controller number in which Memory is connected
Type integer or null
Read Only True
Added iLO6 1.05

MemoryLocation.Slot Member of Memory.v1_14_0.Memory

Description Slot number in which Memory is connected
Type integer or null
Read Only True
Added iLO6 1.05

MemoryLocation.Socket Member of Memory.v1_14_0.Memory

Description Socket number in which Memory is connected
Type integer or null
Read Only True
Added iLO6 1.05

MemoryMedia (array)

Member of Memory.v1_14_0.Memory

MemoryMedia is an array containing elements of:

MemoryMedia[{item}] Member of Memory.v1_14_0.Memory

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
DRAM DRAM media
NAND NAND media
Intel3DXPoint Intel 3D XPoint media
Proprietary Proprietary media

MemorySubsystemControllerManufacturerID

Member of Memory.v1_14_0.Memory

Description The manufacturer ID of the memory subsystem controller of this memory module.
Type string or null
Read Only True
Added iLO6 1.05

MemorySubsystemControllerProductID

Member of Memory.v1_14_0.Memory

Description The product ID of the memory subsystem controller of this memory module.
Type string or null
Read Only True
Added iLO6 1.05

MemoryType

Member of Memory.v1_14_0.Memory

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
DRAM DRAM
NVDIMM_N NVDIMM_N as defined by JEDEC.
NVDIMM_F NVDIMM_F as defined by JEDEC.
NVDIMM_P NVDIMM_P as defined by JEDEC.
IntelOptane The memory module is Intel Optane DC Persistent Memory and composed of a combination of non-volatile and volatile memory.

ModuleManufacturerID

Member of Memory.v1_14_0.Memory

Description The manufacturer ID of this memory module.
Type string or null
Read Only True
Added iLO6 1.05

ModuleProductID

Member of Memory.v1_14_0.Memory

Description The product ID of this memory module.
Type string or null
Read Only True
Added iLO6 1.05

NonVolatileSizeMiB

Member of Memory.v1_14_0.Memory

Description Total size of the non-volatile portion memory in MiB.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.Armed

Member of Memory.v1_14_0.Memory

Description Specifies the current backup-ready status of the NVDIMM_N if available.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.Attributes (array)

Member of Memory.v1_14_0.Memory

Attributes is an array containing elements of:

Attributes[{item}] Member of Memory.v1_14_0.Memory

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
HpeSmartMemory This DIMM is HPE Smart Memory
HpeStandardMemory This DIMM is HPE Standard Memory
HpeLogicalNVDIMM This DIMM is HPE Logical Memory.

Oem.Hpe.BaseModuleType

Member of Memory.v1_14_0.Memory

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
BurstEDO
FastPage
Synchronous
EDO
LRDIMM
RDRAM
RDIMM
UDIMM
NVDIMM
NVDIMM-N
LRNVDIMM
SO_RDIMM_72b
SO_UDIMM_72b
PMM

Oem.Hpe.BlocksRead

Member of Memory.v1_14_0.Memory

Description Number of blocks read for the lifetime of the Memory.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.BlocksWritten

Member of Memory.v1_14_0.Memory

Description Number of blocks written for the lifetime of the Memory.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.DIMMManufacturingDate

Member of Memory.v1_14_0.Memory

Description Module manufacturing date in YYWW format.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.DIMMStatus

Member of Memory.v1_14_0.Memory

Description Specifies memory module status and whether the module in use.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
Unknown The status of the DIMM is unknown.
Other DIMM status that does not fit any of these definitions.
NotPresent DIMM is not present.
PresentUnused DIMM is present but unused.
GoodInUse DIMM is functioning properly and currently in use.
AddedButUnused DIMM is added but currently unused.
UpgradedButUnused DIMM is upgraded but currently unused.
ExpectedButMissing DIMM is expected but missing.
DoesNotMatch DIMM type does not match.
NotSupported DIMM is not supported.
ConfigurationError Configuration error in DIMM.
Degraded DIMM state is degraded.
PresentSpare DIMM is present but used as spare.
GoodPartiallyInUse DIMM is functioning properly but partially in use.
MapOutConfiguration DIMM mapped out due to configuration error.
MapOutError DIMM mapped out due to training failure.

Oem.Hpe.MaxOperatingSpeedMTs

Member of Memory.v1_14_0.Memory

Description Maximum capable speed of the device, in megatransfers per second (MT/s).
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.MinimumVoltageVoltsX10

Member of Memory.v1_14_0.Memory

Description The minimum DIMM voltage multiplied by 10, for example, 1.2v = 12.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.PartNumber

Member of Memory.v1_14_0.Memory

Description The HPE product part number of this device
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.PredictedMediaLifeLeftPercent

Member of Memory.v1_14_0.Memory

Description The percentage of media life left.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.ProductName

Member of Memory.v1_14_0.Memory

Description friendly product name from SMBIOS 202 record
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.RelatedBackupStores (array)

Member of Memory.v1_14_0.Memory

RelatedBackupStores is an array containing elements of:

RelatedBackupStores[{item}].@odata.id Member of Memory.v1_14_0.Memory

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Oem.Hpe.RelatedPhysicalDIMMs (array)

Member of Memory.v1_14_0.Memory

RelatedPhysicalDIMMs is an array containing elements of:

RelatedPhysicalDIMMs[{item}].@odata.id Member of Memory.v1_14_0.Memory

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Oem.Hpe.RelatedPowerBackupUnitBays (array)

Member of Memory.v1_14_0.Memory

RelatedPowerBackupUnitBays is an array containing elements of:

RelatedPowerBackupUnitBays[{item}] Member of Memory.v1_14_0.Memory

Description Battery backup unit bay number.
Type integer
Read Only True
Added iLO6 1.05

Oem.Hpe.SPDBytes (array)

Member of Memory.v1_14_0.Memory

SPDBytes is an array containing elements of:

SPDBytes[{item}] Member of Memory.v1_14_0.Memory

Description The SPD Bytes in the DIMM
Type integer
Read Only True
Added iLO6 1.05

Oem.Hpe.SpareBlockLeftPercent

Member of Memory.v1_14_0.Memory

Description The percentage of the number of spare blocks remaining.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.VendorName

Member of Memory.v1_14_0.Memory

Description Vendor Name decoded from VendorID
Type string or null
Read Only True
Added iLO6 1.05

OperatingMemoryModes (array)

Member of Memory.v1_14_0.Memory

OperatingMemoryModes is an array containing elements of:

OperatingMemoryModes[{item}] Member of Memory.v1_14_0.Memory

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Volatile Volatile memory
PMEM Persistent memory, byte accesible through system address space
Block Block accessible system memory

OperatingSpeedMhz

Member of Memory.v1_14_0.Memory

Description Operating speed of Memory in MHz
Type integer or null
Read Only True
Added iLO6 1.05

PartNumber

Member of Memory.v1_14_0.Memory

Description The product part number of this device
Type string or null
Read Only True
Added iLO6 1.05

PersistentRegionNumberLimit

Member of Memory.v1_14_0.Memory

Description Total number of persistent regions this Memory can support.
Type integer or null
Read Only True
Added iLO6 1.05

PersistentRegionSizeLimitMiB

Member of Memory.v1_14_0.Memory

Description Total size of persistent regions in MiB
Type integer or null
Read Only True
Added iLO6 1.05

PersistentRegionSizeMaxMiB

Member of Memory.v1_14_0.Memory

Description Maximum size of a single persistent region in MiB.
Type integer or null
Read Only True
Added iLO6 1.05

RankCount

Member of Memory.v1_14_0.Memory

Description Number of ranks available in the Memory
Type integer or null
Read Only True
Added iLO6 1.05

Regions (array)

Member of Memory.v1_14_0.Memory

Regions is an array containing elements of:

Regions[{item}].MemoryClassification Member of Memory.v1_14_0.Memory

Description Classification of memory occupied by the given memory region
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Volatile Volatile memory
ByteAccessiblePersistent Byte accessible persistent memory
Block Block accesible memory

Regions[{item}].PassphraseEnabled Member of Memory.v1_14_0.Memory

Description State of the passphrase for this region
Type boolean or null
Read Only True
Added iLO6 1.05

Regions[{item}].RegionId Member of Memory.v1_14_0.Memory

Description Unique region ID representing a specific region within the Memory
Type string or null
Read Only True
Added iLO6 1.05

Regions[{item}].SizeMiB Member of Memory.v1_14_0.Memory

Description Size of this memory region in MiB
Type integer or null
Read Only True
Added iLO6 1.05

SecurityCapabilities

SecurityCapabilities.ConfigurationLockCapable Member of Memory.v1_14_0.Memory

Description Support for configuration locking
Type boolean or null
Read Only True
Added iLO6 1.05

SecurityCapabilities.DataLockCapable Member of Memory.v1_14_0.Memory

Description Support for data locking
Type boolean or null
Read Only True
Added iLO6 1.05

SecurityCapabilities.PassphraseCapable Member of Memory.v1_14_0.Memory

Description Memory passphrase set capability
Type boolean or null
Read Only True
Added iLO6 1.05

SecurityCapabilities.PassphraseLockLimit Member of Memory.v1_14_0.Memory

Description Maximum number of incorrect passphrase attempts allowed before memory is locked.
Type integer or null
Read Only True
Added iLO6 1.05

SecurityState

Member of Memory.v1_14_0.Memory

Description The current security state of this Memory
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Enabled Secure mode is enabled and access to the data is unlocked
Disabled Secure mode is disabled
Locked Secure mode is enabled and access to the data is locked
Passphraselimit Number of attempts to unlock the Memory exceeded limit

SerialNumber

Member of Memory.v1_14_0.Memory

Description The serial number of this device
Type string or null
Read Only True
Added iLO6 1.05

Status

Member of Memory.v1_14_0.Memory See the Redfish standard schema and specification for information on common Status object.

SubsystemDeviceID

Member of Memory.v1_14_0.Memory

Description Subsystem Device ID
Type string or null
Read Only True
Added iLO6 1.05

SubsystemVendorID

Member of Memory.v1_14_0.Memory

Description SubSystem Vendor ID
Type string or null
Read Only True
Added iLO6 1.05

VendorID

Member of Memory.v1_14_0.Memory

Description Vendor ID
Type string or null
Read Only True
Added iLO6 1.05

VolatileRegionNumberLimit

Member of Memory.v1_14_0.Memory

Description Total number of volatile regions this Memory can support.
Type integer or null
Read Only True
Added iLO6 1.05

VolatileRegionSizeLimitMiB

Member of Memory.v1_14_0.Memory

Description Total size of volatile regions in MiB
Type integer or null
Read Only True
Added iLO6 1.05

VolatileRegionSizeMaxMiB

Member of Memory.v1_14_0.Memory

Description Maximum size of a single volatile region in MiB.
Type integer or null
Read Only True
Added iLO6 1.05

VolatileSizeMiB

Member of Memory.v1_14_0.Memory

Description Total size of the volitile portion memory in MiB.
Type integer or null
Read Only True
Added iLO6 1.05

MemoryChunks

@odata.type: "#MemoryChunks.v1_2_3.MemoryChunks"

The MemoryChunks resource describes a Memory Chunk and its configuration.

Resource Instances

Uri HTTP Allow
/redfish/v1/systems/{item}/memorydomains/{item}/memorychunks/{item} GET DELETE

AddressRangeType

Member of MemoryChunks.v1_2_3.MemoryChunks

Description Memory type of this memory chunk
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
PMEM Byte accessible persistent memory

InterleaveSets (array)

Member of MemoryChunks.v1_2_3.MemoryChunks

InterleaveSets is an array containing elements of:

InterleaveSets[{item}].Memory Describes a memory device of the interleave set. Memory is a link ("@odata.id": URI) to another resource.

InterleaveSets[{item}].MemoryLevel Member of MemoryChunks.v1_2_3.MemoryChunks

Description Level of the interleave set for multi-level tiered memory.
Type integer or null
Read Only True
Added iLO6 1.05

InterleaveSets[{item}].OffsetMiB Member of MemoryChunks.v1_2_3.MemoryChunks

Description Offset within the DIMM that corresponds to the start of this memory region, with units in MiB
Type integer or null
Read Only True
Added iLO6 1.05

InterleaveSets[{item}].RegionId Member of MemoryChunks.v1_2_3.MemoryChunks

Description DIMM region identifier
Type string or null
Read Only True
Added iLO6 1.05

InterleaveSets[{item}].SizeMiB Member of MemoryChunks.v1_2_3.MemoryChunks

Description Size of this memory region in MiB
Type integer or null
Read Only True
Added iLO6 1.05

IsMirrorEnabled

Member of MemoryChunks.v1_2_3.MemoryChunks

Description Mirror Enabled status
Type boolean or null
Read Only True
Added iLO6 1.05

IsSpare

Member of MemoryChunks.v1_2_3.MemoryChunks

Description Spare enabled status
Type boolean or null
Read Only True
Added iLO6 1.05

MemoryChunkSizeMiB

Member of MemoryChunks.v1_2_3.MemoryChunks

Description Size of the memory chunk in MiB
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.MemoryChunkSizePercentage

Member of MemoryChunks.v1_2_3.MemoryChunks

Description Size of chunk in percent of total capacity.
Type integer or null
Read Only False
Added iLO6 1.05

Status

Member of MemoryChunks.v1_2_3.MemoryChunks See the Redfish standard schema and specification for information on common Status object.

MemoryChunksCollection

@odata.type: "#MemoryChunksCollection.MemoryChunksCollection"

A Collection of MemoryChunks resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/systems/{item}/memorydomains/{item}/memorychunks GET POST

Links to other Resources

Link Name Destination type
Members[] MemoryChunks

Members (array)

Member of MemoryChunksCollection.MemoryChunksCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of MemoryChunksCollection.MemoryChunksCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of MemoryChunksCollection.MemoryChunksCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

MemoryCollection

@odata.type: "#MemoryCollection.MemoryCollection"

A Collection of Memory resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/systems/{item}/memory GET

Links to other Resources

Link Name Destination type
Members[] Memory

Members (array)

Member of MemoryCollection.MemoryCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of MemoryCollection.MemoryCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of MemoryCollection.MemoryCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

Oem.Hpe.AmpModeActive

Member of MemoryCollection.MemoryCollection

Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Unknown The management software cannot determine the AMP, host OS may not have provided it yet.
Other
None The management software cannot determine the AMP, or the system is not configured for AMP.
Mirroring The system is configured for mirrored memory protection. All memory banks are duplicated in mirrored memory, as opposed to only one for online spare memory. If enough ECC errors occur, the spare memory is activated and the memory that is experiencing the errors is disabled.
OnlineSpare A single spare bank of memory is set aside at boot time. If enough ECC errors occur, the spare memory is activated and the memory that is experiencing the errors is disabled.
RAIDXOR The system is configured for AMP with the XOR engine.
AdvancedECC The system is configured for AMP with the Advanced ECC engine.
Lockstep
A3DC The system is configured for AMP with A3DC.
DIMMECC The system is configured for AMP with DIMM ECC (Error Correcting Code) only.

Oem.Hpe.AmpModeStatus

Member of MemoryCollection.MemoryCollection

Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Unknown The management software cannot determine the status, host OS may not have provided it yet.
Other The system does not support AMP, or the management software cannot determine the status.
NotProtected The system supports AMP, but the feature is disabled.
Protected The system supports AMP. The feature is enabled but not engaged.
Degraded The system was protected, but AMP is engaged. Therefore, AMP is no longer available.
DIMMECC The system is protected by DIMM ECC (Error Correcting Code) only.
Mirroring The system is protected by AMP in the mirrored mode. No DIMM faults have been detected.
DegradedMirroring The system is protected by AMP in the mirrored mode. One or more DIMM faults have been detected.
OnlineSpare The system is protected by AMP in the hot spare mode. No DIMM faults have been detected.
DegradedOnlineSpare
RAIDXOR The system is protected by AMP in the XOR memory mode. No DIMM faults have been detected.
DegradedRAIDXOR The system is protected by AMP in the XOR memory mode. One or more DIMM faults have been detected.
AdvancedECC The system is protected by AMP in the Advanced ECC mode.
DegradedAdvancedECC The system is protected by AMP in the Advanced ECC mode. One or more DIMM faults have been detected.
Lockstep
DegradedLockstep
A3DC The system is protected by AMP in the A3DC mode.
DegradedA3DC The system is protected by AMP in the A3DC mode. One or more DIMM faults have been deteced.
Unsupported

Oem.Hpe.AmpModeSupported (array)

Member of MemoryCollection.MemoryCollection

AmpModeSupported is an array containing elements of:

AmpModeSupported[{item}] Member of MemoryCollection.MemoryCollection

Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
RAIDXOR The system can be configured for AMP using the XOR engine.
DualBoardMirroring The system can be configured for mirrored advanced memory protection in a dual memory board configuration. The mirrored memory can be swapped with memory on the same memory board or with memory on the second memory board.
SingleBoardMirroring The system can be configured for mirrored advanced memory protection in a single memory board.
AdvancedECC The system can be configured for Advanced ECC.
Mirroring The system can be configured for mirrored AMP.
OnlineSpare The system can be configured for online spare AMP.
OnlineSpareRank The system can be configured for Online Spare Rank AMP.
OnlineSpareChannel The system can be configured for Online Spare Channel AMP.
IntersocketMirroring The system can be configured for mirrored intersocket AMP between the memory of two processors or boards.
IntrasocketMirroring The system can be configured for mirrored intrasocket AMP between the memory of a single processor or board.
Lockstep
A3DC The system can be configured for A3DC.
None The system cannot be configured for AMP.
DIMMECC The system can be configured for DIMM ECC (Error Correcting Code) only.

Oem.Hpe.MemoryList (array)

Member of MemoryCollection.MemoryCollection

MemoryList is an array containing elements of:

MemoryList[{item}].BoardCpuNumber Member of MemoryCollection.MemoryCollection

Type integer or null
Read Only True
Added iLO6 1.05

MemoryList[{item}].BoardMemoryType Member of MemoryCollection.MemoryCollection

Description Board Memory Type - DIMM/HBM.
Type string or null
Read Only True
Added iLO6 1.40

MemoryList[{item}].BoardNumberOfSockets Member of MemoryCollection.MemoryCollection

Description The number of present memory module sockets.
Type integer or null
Read Only True
Added iLO6 1.05

MemoryList[{item}].BoardOperationalFrequency Member of MemoryCollection.MemoryCollection

Description The frequency at which memory on the board is operating in MHz.
Type integer or null
Read Only True
Added iLO6 1.05

MemoryList[{item}].BoardOperationalVoltage Member of MemoryCollection.MemoryCollection

Description The voltage at which memory on the board is operating in mV.
Type integer or null
Read Only True
Added iLO6 1.05

MemoryList[{item}].BoardTotalMemorySize Member of MemoryCollection.MemoryCollection

Description The total size of the memory populated on the board in MB.
Type integer or null
Read Only True
Added iLO6 1.05

MemoryDomain

@odata.type: "#MemoryDomain.v1_2_1.MemoryDomain"

The MemoryDomain resource describes a Memory Domain and its configuration. Memory Domains are used to indicate to the client which Memory (DIMMs) can be grouped together in Memory Chunks to form interleave sets or otherwise grouped together.

Resource Instances

Uri HTTP Allow
/redfish/v1/systems/{item}/memorydomains/{item} GET

AllowsBlockProvisioning

Member of MemoryDomain.v1_2_1.MemoryDomain

Description Indicates if this Memory Domain supports the provisioning of blocks of memory.
Type boolean or null
Read Only True
Added iLO6 1.05

AllowsMemoryChunkCreation

Member of MemoryDomain.v1_2_1.MemoryDomain

Description Indicates if this Memory Domain supports the creation of Memory Chunks.
Type boolean or null
Read Only True
Added iLO6 1.05

AllowsMirroring

Member of MemoryDomain.v1_2_1.MemoryDomain

Description Indicates if this Memory Domain supports the creation of Memory Chunks with mirroring enabled.
Type boolean or null
Read Only True
Added iLO6 1.05

AllowsSparing

Member of MemoryDomain.v1_2_1.MemoryDomain

Description Indicates if this Memory Domain supports the creation of Memory Chunks with sparing enabled.
Type boolean or null
Read Only True
Added iLO6 1.05

InterleavableMemorySets (array)

Member of MemoryDomain.v1_2_1.MemoryDomain

InterleavableMemorySets is an array containing elements of:

InterleavableMemorySets[{item}].MemorySet (array) Member of MemoryDomain.v1_2_1.MemoryDomain

MemorySet is an array containing elements of:

MemorySet[{item}].@odata.id Member of MemoryDomain.v1_2_1.MemoryDomain

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

InterleavableMemorySets[{item}].MemorySet@odata.count Member of MemoryDomain.v1_2_1.MemoryDomain

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

MemoryChunks

A reference to the collection of Memory Chunks associated with this Memory Domain. MemoryChunks is a link ("@odata.id": URI) to another resource.

MemoryDomainCollection

@odata.type: "#MemoryDomainCollection.MemoryDomainCollection"

A Collection of MemoryDomain resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/systems/{item}/memorydomains GET

Links to other Resources

Link Name Destination type
Members[] MemoryDomain

Members (array)

Member of MemoryDomainCollection.MemoryDomainCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of MemoryDomainCollection.MemoryDomainCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of MemoryDomainCollection.MemoryDomainCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

MemoryMetrics

@odata.type: "#MemoryMetrics.v1_7_3.MemoryMetrics"

The MemoryMetrics schema shall contain the memory metrics for a memory device or system memory summary in a Redfish implementation.

Resource Instances

Uri HTTP Allow
/redfish/v1/systems/{item}/memory/{item}/memorymetrics GET

Oem.Hpe.PageRetirementCounts

Member of MemoryMetrics.v1_7_3.MemoryMetrics

Description This property shall contain Memory page counters for this resource.
Type integer
Read Only True
Added iLO6 1.61

OperatingSpeedMHz

Member of MemoryMetrics.v1_7_3.MemoryMetrics

Description Operating speed of memory in MHz or MT/s as appropriate.
Type integer or null
Read Only True
Added iLO6 1.61

MessageRegistryFile

@odata.type: "#MessageRegistryFile.v1_0_4.MessageRegistryFile"

The MessageRegistryFile resource describes the Schema File locator resource.

Resource Instances

Uri HTTP Allow
/redfish/v1/registries/{item} GET

Languages (array)

Member of MessageRegistryFile.v1_0_4.MessageRegistryFile

Languages is an array containing elements of:

Languages[{item}] Member of MessageRegistryFile.v1_0_4.MessageRegistryFile

Type string
Read Only True
Added iLO6 1.05

Location (array)

Member of MessageRegistryFile.v1_0_4.MessageRegistryFile

Location is an array containing elements of:

Location[{item}].Language Member of MessageRegistryFile.v1_0_4.MessageRegistryFile

Description The RFC 5646 language code for this schema or registry item.
Type string
Read Only True
Added iLO6 1.05

Location[{item}].Uri Member of MessageRegistryFile.v1_0_4.MessageRegistryFile

Description Link to locally available URI for schema.
Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Registry

Member of MessageRegistryFile.v1_0_4.MessageRegistryFile

Description The Registry Name, Major and Minor version used in MessageID construction.
Type string
Read Only True
Added iLO6 1.05

MessageRegistryFileCollection

@odata.type: "#MessageRegistryFileCollection.MessageRegistryFileCollection"

A Collection of MessageRegistryFile resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/registries GET

Links to other Resources

Link Name Destination type
Members[] MessageRegistryFile

Members (array)

Member of MessageRegistryFileCollection.MessageRegistryFileCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of MessageRegistryFileCollection.MessageRegistryFileCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of MessageRegistryFileCollection.MessageRegistryFileCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

MetricDefinition

@odata.type: "#MetricDefinition.v1_0_0.MetricDefinition"

The metadata information about a metric.

Resource Instances

Uri HTTP Allow
/redfish/v1/telemetryservice/metricdefinitions/{item} GET

Calculable

Member of MetricDefinition.v1_0_0.MetricDefinition

Description The types of calculations which can be applied to the metric reading. This property provides information to the client on the suitability of calculatiion using the metric reading.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
NonCalculatable No calculations should be performed on the metric reading.
Summable The sum of the metric reading across multiple instances is meaningful.
NonSummable The sum of the metric reading across multiple instances is not meaningful.

CalculationAlgorithm

Member of MetricDefinition.v1_0_0.MetricDefinition

Description The calculation which is performed on a source metric to obtain the metric being defined.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Average The metric is calculated as the average of a metric reading over a sliding time interval.
Maximum The metric is calculated as the maximum value of a metric reading over during a time interval.
Minimum The metric is calculated as the minimum value of a metric reading over a sliding time interval.

Implementation

Member of MetricDefinition.v1_0_0.MetricDefinition

Description The implementation of the metric.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
PhysicalSensor The metric is implemented as a physical sensor.
Calculated The metric is implemented by applying a calculation on another metric property. The calculation is specified in the CalculationAlgorithm property.
Synthesized The metric is implemented by applying a calculation on one or more metric properties. (The calculation is not specified. For expressing generalized formula, see MathSON).
DigitalMeter The metric is implemented as digital meter.

IsLinear

Member of MetricDefinition.v1_0_0.MetricDefinition

Description Indicates whether the metric values are linear (vs non-linear).
Type boolean or null
Read Only False
Added iLO6 1.05

MaxReadingRange

Member of MetricDefinition.v1_0_0.MetricDefinition

Description Maximum value for metric reading.
Type integer or null
Read Only True
Added iLO6 1.05

MetricDataType

Member of MetricDefinition.v1_0_0.MetricDefinition

Description The data type of the related metric values. The property provides information to the client on the nature of the metric reading.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Boolean The data type follows the JSON Boolean definition.
DateTime The data type follows the JSON String definition with the Date-Time format applied.
Decimal The data type follows the JSON Decimal definition.
Integer The data type follows the JSON Integer definition.
String The data type follows the JSON String definition.
Enumeration The data type follows the JSON String definition with a set of enumerations defined.

MetricProperties (array)

Member of MetricDefinition.v1_0_0.MetricDefinition

MetricProperties is an array containing elements of:

MetricProperties[{item}] Member of MetricDefinition.v1_0_0.MetricDefinition

Type string or null
Read Only True
Added iLO6 1.05

MetricType

Member of MetricDefinition.v1_0_0.MetricDefinition

Description Specifies the type of metric provided. The property provides information to the client on how the metric can be handled.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Numeric The metric is a numeric metric. The metric value is any real number.
Discrete The metric is a discrete metric. The metric value is discrete. The possible values are listed in the DiscreteValues property.
Gauge The metric is a gauge metric. The metric value is a real number. When the metric value reaches the gauges extrema, it stays at that value, until the reading falls within the extrema.
Counter The metric is a counter metric. The metric reading is a non-negative integer which increases monotonically. When a counter reaches its maximum, the value resets to 0 and resumes counting.
Countdown The metric is a countdown metric. The metric reading is a non-negative integer which decreases monotonically. When a counter reaches its minimum, the value resets to preset value and resumes counting down.

MinReadingRange

Member of MetricDefinition.v1_0_0.MetricDefinition

Description Minimum value for metric reading.
Type integer or null
Read Only True
Added iLO6 1.05

Units

Member of MetricDefinition.v1_0_0.MetricDefinition

Description The units of measure for this metric.
Type string or null
Read Only False
Added iLO6 1.05

MetricDefinitionCollection

@odata.type: "#MetricDefinitionCollection.MetricDefinitionCollection"

A Collection of MetricDefinition resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/telemetryservice/metricdefinitions GET

Links to other Resources

Link Name Destination type
Members[] MetricDefinition

Members (array)

Member of MetricDefinitionCollection.MetricDefinitionCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of MetricDefinitionCollection.MetricDefinitionCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of MetricDefinitionCollection.MetricDefinitionCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

MetricReport

@odata.type: "#MetricReport.v1_0_0.MetricReport"

The metric definitions used to create a metric report.

Resource Instances

Uri HTTP Allow
/redfish/v1/telemetryservice/metricreports/{item} GET

MetricReportDefinition

The metric definitions used to create a metric report. MetricReportDefinition is a link ("@odata.id": URI) to another resource.

MetricValues (array)

Member of MetricReport.v1_0_0.MetricReport

MetricValues is an array containing elements of:

MetricValues[{item}].MetricDefinition A link to the Metric Definition. MetricDefinition is a link ("@odata.id": URI) to another resource.

MetricValues[{item}].MetricId Member of MetricReport.v1_0_0.MetricReport

Description The metric definitions identifier for this metric.
Type string or null
Read Only True
Added iLO6 1.05

MetricValues[{item}].MetricValue Member of MetricReport.v1_0_0.MetricReport

Description The value identifies this resource.
Type string or null
Read Only True
Added iLO6 1.05

MetricValues[{item}].Timestamp Member of MetricReport.v1_0_0.MetricReport

Description The time when the value of the metric is obtained.
Type string or null
Read Only True
Added iLO6 1.05
Format date-time

MetricReportCollection

@odata.type: "#MetricReportCollection.MetricReportCollection"

A Collection of MetricReport resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/telemetryservice/metricreports GET

Links to other Resources

Link Name Destination type
Members[] MetricReport

Members (array)

Member of MetricReportCollection.MetricReportCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of MetricReportCollection.MetricReportCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of MetricReportCollection.MetricReportCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

MetricReportDefinition

@odata.type: "#MetricReportDefinition.v1_4_2.MetricReportDefinition"

A set of metrics that are collected into a metric report.

Resource Instances

Uri HTTP Allow
/redfish/v1/telemetryservice/metricreportdefinitions/{item} GET

MetricProperties (array)

Member of MetricReportDefinition.v1_4_2.MetricReportDefinition

MetricProperties is an array containing elements of:

MetricProperties[{item}] Member of MetricReportDefinition.v1_4_2.MetricReportDefinition

Type string or null
Read Only True
Added iLO6 1.05

MetricReport

Specifies the location where the resultant metric report is placed. MetricReport is a link ("@odata.id": URI) to another resource.

MetricReportDefinitionType

Member of MetricReportDefinition.v1_4_2.MetricReportDefinition

Description Indicates when the metric report is generated.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
Periodic The metric report is generated at a periodic time interval, specified in the Schedule property.
OnChange The metric report is generated when any of the metric values change.
OnRequest The metric report is generated when a HTTP GET is performed on the specified metric report.

Metrics (array)

Member of MetricReportDefinition.v1_4_2.MetricReportDefinition

Metrics is an array containing elements of:

Metrics[{item}].CollectionDuration Member of MetricReportDefinition.v1_4_2.MetricReportDefinition

Description Specifies the duration over which the function is computed.
Type string or null
Read Only False
Added iLO6 1.05

Metrics[{item}].CollectionFunction Member of MetricReportDefinition.v1_4_2.MetricReportDefinition

Description Specifies the function to apply to the list of metric properties.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
Average The metric is calculated as the average of a metric reading over a sliding time interval.
Maximum The metric is calculated as the maximum value of a metric reading over during a time interval.
Minimum The metric is calculated as the minimum value of a metric reading over a sliding time interval.
Summation The metric is calculated as the sum of the values over a sliding time interval.

Metrics[{item}].CollectionTimeScope Member of MetricReportDefinition.v1_4_2.MetricReportDefinition

Description The time scope of the related metric values.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
Point The corresponding metric values apply to a point in time. On the corresponding metric value instances, the value of Timestamp shall specify the point in time.
Interval The corresponding metric values apply to a time interval. On the corresponding metric value instances, the value of Timestamp shall specify the end of the time interval and Duration shall specify its duration.
StartupInterval The corresponding metric values apply to a time interval that began at the startup of the measured resource (i.e. the Resources associated by Links.MetricDefinitionForResources). On the corresponding metric value instances, the value of Timestamp shall specify the end of the time interval. The value of Duration shall specifies the duration between startup of the resource and TimeStamp.

Metrics[{item}].MetricId Member of MetricReportDefinition.v1_4_2.MetricReportDefinition

Description Specifies the label for the metric definition which is derived by applying the CollectionFunction to the metric property.
Type string or null
Read Only True
Added iLO6 1.05

Metrics[{item}].MetricProperties (array) Member of MetricReportDefinition.v1_4_2.MetricReportDefinition

MetricProperties is an array containing elements of:

MetricProperties[{item}] Member of MetricReportDefinition.v1_4_2.MetricReportDefinition

Type string or null
Read Only True
Added iLO6 1.05

Schedule

Schedule.EnabledDaysOfMonth (array) Member of MetricReportDefinition.v1_4_2.MetricReportDefinition

EnabledDaysOfMonth is an array containing elements of:

EnabledDaysOfMonth[{item}] Member of MetricReportDefinition.v1_4_2.MetricReportDefinition

Type integer or null
Read Only True
Added iLO6 1.51

Schedule.InitialStartTime Member of MetricReportDefinition.v1_4_2.MetricReportDefinition

Description The date and time when the initial occurrence is scheduled to occur.
Type string or null
Read Only False
Added iLO6 1.51
Format date-time

Schedule.RecurrenceInterval Member of MetricReportDefinition.v1_4_2.MetricReportDefinition

Description The duration between consecutive occurrences.
Type string or null
Read Only False
Added iLO6 1.51

Status

Member of MetricReportDefinition.v1_4_2.MetricReportDefinition See the Redfish standard schema and specification for information on common Status object.

MetricReportDefinitionCollection

@odata.type: "#MetricReportDefinitionCollection.MetricReportDefinitionCollection"

A Collection of MetricReportDefinition resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/telemetryservice/metricreportdefinitions GET

Links to other Resources

Link Name Destination type
Members[] MetricReportDefinition

Members (array)

Member of MetricReportDefinitionCollection.MetricReportDefinitionCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of MetricReportDefinitionCollection.MetricReportDefinitionCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of MetricReportDefinitionCollection.MetricReportDefinitionCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

PCIeDevice

@odata.type: "#PCIeDevice.v1_5_0.PCIeDevice"

This is the schema definition for the PCIeDevice resource. It represents the properties of a PCIe Device attached to a System.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/pciedevices/{item} GET PATCH

Links to other Resources

Link Name Destination type
PCIeFunctions PCIeFunction

AssetTag

Member of PCIeDevice.v1_5_0.PCIeDevice

Description The user-assigned asset tag for this PCIe device.
Type string or null
Read Only False
Added iLO6 1.20

DeviceType

Member of PCIeDevice.v1_5_0.PCIeDevice

Description The device type for this PCIe device.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
SingleFunction A single-function PCIe device.
MultiFunction A multi-function PCIe device.
Simulated A PCIe device which is not currently physically present, but is being simulated by the PCIe infrastructure.

FirmwareVersion

Member of PCIeDevice.v1_5_0.PCIeDevice

Description The version of firmware for this PCIe device.
Type string or null
Read Only True
Added iLO6 1.05

Manufacturer

Member of PCIeDevice.v1_5_0.PCIeDevice

Description The manufacturer of this PCIe device.
Type string or null
Read Only True
Added iLO6 1.05

Model

Member of PCIeDevice.v1_5_0.PCIeDevice

Description The model number for the PCIe device.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.FirmwareVersion (array)

Member of PCIeDevice.v1_5_0.PCIeDevice

FirmwareVersion is an array containing elements of:

FirmwareVersion[{item}].ComponentName Member of PCIeDevice.v1_5_0.PCIeDevice

Description Name of GPU cores
Type string or null
Read Only True
Added iLO6 1.10

FirmwareVersion[{item}].VersionString Member of PCIeDevice.v1_5_0.PCIeDevice

Description Version string of GPU cores
Type string or null
Read Only True
Added iLO6 1.10

PCIeFunctions

The link to the collection of PCIe functions associated with this PCIe device. PCIeFunctions is a link ("@odata.id": URI) to another resource.

PCIeInterface

PCIeInterface.LanesInUse Member of PCIeDevice.v1_5_0.PCIeDevice

Description The number of PCIe lanes in use by this device.
Type integer or null
Read Only True
Added iLO6 1.05

PCIeInterface.MaxLanes Member of PCIeDevice.v1_5_0.PCIeDevice

Description The number of PCIe lanes supported by this device.
Type integer or null
Read Only True
Added iLO6 1.05

PCIeInterface.MaxPCIeType Member of PCIeDevice.v1_5_0.PCIeDevice

Description The highest version of the PCIe specification supported by this device.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Gen1 A PCIe v1.0 slot.
Gen2 A PCIe v2.0 slot.
Gen3 A PCIe v3.0 slot.
Gen4 A PCIe v4.0 slot.
Gen5 A PCIe v5.0 slot.

PCIeInterface.PCIeType Member of PCIeDevice.v1_5_0.PCIeDevice

Description The version of the PCIe specification in use by this device.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Gen1 A PCIe v1.0 slot.
Gen2 A PCIe v2.0 slot.
Gen3 A PCIe v3.0 slot.
Gen4 A PCIe v4.0 slot.
Gen5 A PCIe v5.0 slot.

PartNumber

Member of PCIeDevice.v1_5_0.PCIeDevice

Description The part number for this PCIe device.
Type string or null
Read Only True
Added iLO6 1.05

SKU

Member of PCIeDevice.v1_5_0.PCIeDevice

Description The SKU for this PCIe device.
Type string or null
Read Only True
Added iLO6 1.05

SerialNumber

Member of PCIeDevice.v1_5_0.PCIeDevice

Description The serial number for this PCIe device.
Type string or null
Read Only True
Added iLO6 1.05

Status

Member of PCIeDevice.v1_5_0.PCIeDevice See the Redfish standard schema and specification for information on common Status object.

PCIeDeviceCollection

@odata.type: "#PCIeDeviceCollection.PCIeDeviceCollection"

The collection of PCIeDevice Resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/pciedevices GET

Links to other Resources

Link Name Destination type
Members[] PCIeDevice

Members (array)

Member of PCIeDeviceCollection.PCIeDeviceCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of PCIeDeviceCollection.PCIeDeviceCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of PCIeDeviceCollection.PCIeDeviceCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

PCIeFunction

@odata.type: "#PCIeFunction.v1_2_3.PCIeFunction"

The schema definition for the PCIeFunction Resource. It represents the properties of a PCIeFunction attached to a System.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/pciedevices/{item}/pciefunctions/{item} GET

ClassCode

Member of PCIeFunction.v1_2_3.PCIeFunction

Description The Class Code of this PCIe function.
Type string or null
Read Only True
Added iLO6 1.05

DeviceClass

Member of PCIeFunction.v1_2_3.PCIeFunction

Description The class for this PCIe function.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
UnclassifiedDevice An unclassified device.
MassStorageController A mass storage controller.
NetworkController A network controller.
DisplayController A display controller.
MultimediaController A multimedia controller.
MemoryController A memory controller.
Bridge A bridge.
CommunicationController A communication controller.
GenericSystemPeripheral A generic system peripheral.
InputDeviceController An input device controller.
DockingStation A docking station.
Processor A processor.
SerialBusController A serial bus controller.
WirelessController A wireless controller.
IntelligentController An intelligent controller.
SatelliteCommunicationsController A satellite communications controller.
EncryptionController An encryption controller.
SignalProcessingController A signal processing controller.
ProcessingAccelerators A processing accelerators.
NonEssentialInstrumentation A non-essential instrumentation.
Coprocessor A coprocessor.
UnassignedClass An unassigned class.
Other A other class. The function Device Class Id needs to be verified.

DeviceId

Member of PCIeFunction.v1_2_3.PCIeFunction

Description The Device ID of this PCIe function.
Type string or null
Read Only True
Added iLO6 1.05

FunctionId

Member of PCIeFunction.v1_2_3.PCIeFunction

Description The PCIe Function Number.
Type integer or null
Read Only True
Added iLO6 1.05

FunctionType

Member of PCIeFunction.v1_2_3.PCIeFunction

Description The type of the PCIe function.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Physical A physical PCIe function.
Virtual A virtual PCIe function.

RevisionId

Member of PCIeFunction.v1_2_3.PCIeFunction

Description The Revision ID of this PCIe function.
Type string or null
Read Only True
Added iLO6 1.05

Status

Member of PCIeFunction.v1_2_3.PCIeFunction See the Redfish standard schema and specification for information on common Status object.

SubsystemId

Member of PCIeFunction.v1_2_3.PCIeFunction

Description The Subsystem ID of this PCIe function.
Type string or null
Read Only True
Added iLO6 1.05

SubsystemVendorId

Member of PCIeFunction.v1_2_3.PCIeFunction

Description The Subsystem Vendor ID of this PCIe function.
Type string or null
Read Only True
Added iLO6 1.05

VendorId

Member of PCIeFunction.v1_2_3.PCIeFunction

Description The Vendor ID of this PCIe function.
Type string or null
Read Only True
Added iLO6 1.05

PCIeFunctionCollection

@odata.type: "#PCIeFunctionCollection.PCIeFunctionCollection"

The collection of PCIeFunction Resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/pciedevices/{item}/pciefunctions GET

Links to other Resources

Link Name Destination type
Members[] PCIeFunction

Members (array)

Member of PCIeFunctionCollection.PCIeFunctionCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of PCIeFunctionCollection.PCIeFunctionCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of PCIeFunctionCollection.PCIeFunctionCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

PCIeSlots

@odata.type: "#PCIeSlots.v1_3_0.PCIeSlots"

The PCIeSlots schema describes PCIe slot properties.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/pcieslots GET

Slots (array)

Member of PCIeSlots.v1_3_0.PCIeSlots

Slots is an array containing elements of:

Slots[{item}].HotPluggable Member of PCIeSlots.v1_3_0.PCIeSlots

Description An indication of whether this PCIe slot supports hotplug.
Type boolean or null
Read Only True
Added iLO6 1.05

Slots[{item}].Lanes Member of PCIeSlots.v1_3_0.PCIeSlots

Description The number of PCIe lanes supported by this slot.
Type integer or null
Read Only True
Added iLO6 1.05

Slots[{item}].Location Slots[{item}].Location.PartLocation Slots[{item}].Location.PartLocation.LocationOrdinalValue Member of PCIeSlots.v1_3_0.PCIeSlots

Description The number that represents the location of the part. If LocationType is slot and this unit is in slot 2, the LocationOrdinalValue is 2.
Type integer or null
Read Only True
Added iLO6 1.05

Slots[{item}].Location.PartLocation.LocationType Member of PCIeSlots.v1_3_0.PCIeSlots

Description The location types for PartLocation.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
Slot The slot as the type of location.
Bay The bay as the type of location.
Connector The connector as the type of location.
Socket The socket as the type of location.
Embedded Embedded within a part.

Slots[{item}].Location.PartLocation.Orientation Member of PCIeSlots.v1_3_0.PCIeSlots

Description The orientation for the ordering of the part location ordinal value.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
FrontToBack The ordering for LocationOrdinalValue is front to back.
BackToFront The ordering for the LocationOrdinalValue is back to front.
TopToBottom The ordering for the LocationOrdinalValue is top to bottom.
BottomToTop The ordering for LocationOrdinalValue is bottom to top.
LeftToRight The ordering for the LocationOrdinalValue is left to right.
RightToLeft The ordering for the LocationOrdinalValue is right to left.

Slots[{item}].Location.PartLocation.Reference Member of PCIeSlots.v1_3_0.PCIeSlots

Description The reference area for the location of the part.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
Top The part is in the top of the unit.
Bottom The part is in the bottom of the unit.
Front The part is in the front of the unit.
Rear The part is in the rear of the unit.
Left The part is on the left side of of the unit.
Right The part is on the right side of the unit.
Middle The part is in the middle of the unit.

Slots[{item}].Location.PartLocation.ServiceLabel Member of PCIeSlots.v1_3_0.PCIeSlots

Description The label of the part location, such as a silk-screened name or a printed label.
Type string or null
Read Only True
Added iLO6 1.05

Slots[{item}].Location.Placement Slots[{item}].Location.Placement.AdditionalInfo Member of PCIeSlots.v1_3_0.PCIeSlots

Description Area designation or other additional info.
Type string or null
Read Only False
Added iLO6 1.05

Slots[{item}].Location.Placement.Rack Member of PCIeSlots.v1_3_0.PCIeSlots

Description The name of a rack location within a row.
Type string or null
Read Only False
Added iLO6 1.05

Slots[{item}].Location.Placement.RackOffset Member of PCIeSlots.v1_3_0.PCIeSlots

Description The vertical location of the item, in terms of RackOffsetUnits.
Type integer or null
Read Only False
Added iLO6 1.05

Slots[{item}].Location.Placement.RackOffsetUnits Member of PCIeSlots.v1_3_0.PCIeSlots

Description The type of rack unit in use.
Type string or null
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
OpenU A rack unit that is equal to 48 mm (1.89 in).
EIA_310 A rack unit that is equal to 1.75 in (44.45 mm).

Slots[{item}].Location.Placement.Row Member of PCIeSlots.v1_3_0.PCIeSlots

Description The name of the row.
Type string or null
Read Only False
Added iLO6 1.05

Slots[{item}].PCIeType Member of PCIeSlots.v1_3_0.PCIeSlots

Description The PCIe specification supported by this slot.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Gen1 A PCIe v1.0 slot.
Gen2 A PCIe v2.0 slot.
Gen3 A PCIe v3.0 slot.
Gen4 A PCIe v4.0 slot.
Gen5 A PCIe v5.0 slot.

Slots[{item}].SlotType Member of PCIeSlots.v1_3_0.PCIeSlots

Description The PCIe slot type for this slot.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
FullLength Full-Length PCIe slot.
HalfLength Half-Length PCIe slot.
LowProfile Low-Profile or Slim PCIe slot.
Mini Mini PCIe slot.
M2 PCIe M.2 slot.
OEM An OEM-specific slot.
OCP3Small Open Compute Project 3.0 small form factor slot.
OCP3Large Open Compute Project 3.0 large form factor slot.
U2 PCIe U.2 slot or bay

Slots[{item}].Status Member of PCIeSlots.v1_3_0.PCIeSlots See the Redfish standard schema and specification for information on common Status object.

Port

@odata.type: "#Port.v1_12_0.Port"

A Port represents a discrete physical port capable of connecting to a network.

The Data Source is either DCi or RDE. HPE OEM section shall be present only for DCi Data Source.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/networkadapters/{item}/ports/{item} GET POST PATCH
/redfish/v1/chassis/{item}/networkadapters/{item}/ports/{item}/settings GET PATCH
/redfish/v1/fabrics/{item}/switches/{item}/Ports/{item} GET POST
/redfish/v1/managers/{item}/dedicatednetworkports/{item} GET PATCH
/redfish/v1/managers/{item}/sharednetworkports/{item} GET PATCH
/redfish/v1/systems/{item}/networkinterfaces/{item}/ports/{item} GET POST PATCH
/redfish/v1/systems/{item}/networkinterfaces/{item}/ports/{item}/settings GET PATCH
/redfish/v1/systems/{item}/storage/{item}/controllers/{item}/ports/{item} GET PATCH
/redfish/v1/systems/{item}/storage/{item}/storagecontrollers/{item}/ports/{item} GET PATCH

Links to other Resources

Link Name Destination type
settings Port

@Redfish.Settings

Member of Port.v1_12_0.Port See the Redfish standard schema and specification for information on common @Redfish properties.

ActiveWidth

Member of Port.v1_12_0.Port

Description The number of active lanes for this interface.
Type integer
Read Only True
Added iLO6 1.05

CapableProtocolVersions (array)

Member of Port.v1_12_0.Port

CapableProtocolVersions is an array containing elements of:

CapableProtocolVersions[{item}] Member of Port.v1_12_0.Port

Type string or null
Read Only True
Added iLO6 1.05

CurrentProtocolVersion

Member of Port.v1_12_0.Port

Description The protocol version being sent over this port.
Type string or null
Read Only True
Added iLO6 1.05

CurrentSpeedGbps

Member of Port.v1_12_0.Port

Description The current speed of this port.
Type integer or null
Read Only True
Added iLO6 1.05

Enabled

Member of Port.v1_12_0.Port

Description An indication of whether this port is enabled.
Type boolean
Read Only False
Added iLO6 1.05

Ethernet

Ethernet.AssociatedMACAddresses (array) Member of Port.v1_12_0.Port

AssociatedMACAddresses is an array containing elements of:

AssociatedMACAddresses[{item}] Member of Port.v1_12_0.Port

Type string or null
Read Only True
Added iLO6 1.05

Ethernet.EEEEnabled Member of Port.v1_12_0.Port

Description Indicates whether IEEE 802.3az Energy-Efficient Ethernet (EEE) is enabled on this port.
Type boolean or null
Read Only False
Added iLO6 1.05

Ethernet.FlowControlConfiguration Member of Port.v1_12_0.Port

Description The locally configured 802.3x flow control setting for this port.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
None No IEEE 802.3x flow control is enabled on this port.
TX IEEE 802.3x flow control may be initiated by this station.
RX IEEE 802.3x flow control may be initiated by the link partner.
TX_RX IEEE 802.3x flow control may be initiated by this station or the link partner.

Ethernet.FlowControlStatus Member of Port.v1_12_0.Port

Description The 802.3x flow control behavior negotiated with the link partner for this port.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
None No IEEE 802.3x flow control is enabled on this port.
TX IEEE 802.3x flow control may be initiated by this station.
RX IEEE 802.3x flow control may be initiated by the link partner.
TX_RX IEEE 802.3x flow control may be initiated by this station or the link partner.

Ethernet.LLDPEnabled Member of Port.v1_12_0.Port

Description Enable/disable LLDP for this port.
Type boolean
Read Only False
Added iLO6 1.05

Ethernet.LLDPReceive Ethernet.LLDPReceive.ChassisId Member of Port.v1_12_0.Port

Description Link Layer Data Protocol (LLDP) chassis ID received from the remote partner across this link.
Type string or null
Read Only True
Added iLO6 1.05

Ethernet.LLDPReceive.ChassisIdSubtype Member of Port.v1_12_0.Port

Description The type of identifier used for the chassis ID received from the remote partner across this link.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
ChassisComp Chassis component, based in the value of entPhysicalAlias in RFC4133.
IfAlias Interface alias, based on the ifAlias MIB object.
PortComp Port component, based in the value of entPhysicalAlias in RFC4133.
MacAddr MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802.
NetworkAddr Network address, based on an agent detected network address.
IfName Interface name, based on the ifName MIB object.
AgentId Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC3046.
LocalAssign Locally assigned, based on a alpha-numeric value locally assigned.
NotTransmitted No data to be sent to/received from remote partner.

Ethernet.LLDPReceive.ManagementAddressIPv4 Member of Port.v1_12_0.Port

Description The IPv4 management address received from the remote partner across this link.
Type string or null
Read Only True
Added iLO6 1.05

Ethernet.LLDPReceive.ManagementAddressIPv6 Member of Port.v1_12_0.Port

Description The IPv6 management address received from the remote partner across this link.
Type string or null
Read Only True
Added iLO6 1.05

Ethernet.LLDPReceive.ManagementAddressMAC Member of Port.v1_12_0.Port

Description The management MAC address received from the remote partner across this link.
Type string or null
Read Only True
Added iLO6 1.05

Ethernet.LLDPReceive.ManagementVlanId Member of Port.v1_12_0.Port

Description The management VLAN ID received from the remote partner across this link.
Type integer or null
Read Only True
Added iLO6 1.05

Ethernet.LLDPReceive.PortId Member of Port.v1_12_0.Port

Description A colon delimited string of hexadecimal octets identifying a port.
Type string or null
Read Only True
Added iLO6 1.05

Ethernet.LLDPReceive.PortIdSubtype Member of Port.v1_12_0.Port

Description The port ID subtype received from the remote partner across this link.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
ChassisComp Chassis component, based in the value of entPhysicalAlias in RFC4133.
IfAlias Interface alias, based on the ifAlias MIB object.
PortComp Port component, based in the value of entPhysicalAlias in RFC4133.
MacAddr MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802.
NetworkAddr Network address, based on an agent detected network address.
IfName Interface name, based on the ifName MIB object.
AgentId Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC3046.
LocalAssign Locally assigned, based on a alpha-numeric value locally assigned.
NotTransmitted No data to be sent to/received from remote partner.

Ethernet.LLDPReceive.SystemCapabilities (array) Member of Port.v1_12_0.Port

SystemCapabilities is an array containing elements of:

SystemCapabilities[{item}] Member of Port.v1_12_0.Port

Type string
Read Only True
Added iLO6 1.63

The following are the supported values:

Value
None
Bridge
DOCSISCableDevice
Other
Repeater
Router
Station
Telephone
WLANAccessPoint

Ethernet.LLDPReceive.SystemDescription Member of Port.v1_12_0.Port

Description The system description received from the remote partner across this link.
Type string or null
Read Only True
Added iLO6 1.63

Ethernet.LLDPReceive.SystemName Member of Port.v1_12_0.Port

Description The system name received from the remote partner across this link.
Type string or null
Read Only True
Added iLO6 1.63

Ethernet.LLDPTransmit Ethernet.LLDPTransmit.ChassisId Member of Port.v1_12_0.Port

Description Link Layer Data Protocol (LLDP) chassis ID.
Type string or null
Read Only False
Added iLO6 1.05

Ethernet.LLDPTransmit.ChassisIdSubtype Member of Port.v1_12_0.Port

Description The type of identifier used for the chassis ID.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
ChassisComp Chassis component, based in the value of entPhysicalAlias in RFC4133.
IfAlias Interface alias, based on the ifAlias MIB object.
PortComp Port component, based in the value of entPhysicalAlias in RFC4133.
MacAddr MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802.
NetworkAddr Network address, based on an agent detected network address.
IfName Interface name, based on the ifName MIB object.
AgentId Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC3046.
LocalAssign Locally assigned, based on a alpha-numeric value locally assigned.
NotTransmitted No data to be sent to/received from remote partner.

Ethernet.LLDPTransmit.ManagementAddressIPv4 Member of Port.v1_12_0.Port

Description The IPv4 management address to be transmitted from this endpoint.
Type string or null
Read Only False
Added iLO6 1.05

Ethernet.LLDPTransmit.ManagementAddressIPv6 Member of Port.v1_12_0.Port

Description The IPv6 management address to be transmitted from this endpoint.
Type string or null
Read Only False
Added iLO6 1.05

Ethernet.LLDPTransmit.ManagementAddressMAC Member of Port.v1_12_0.Port

Description The management MAC address to be transmitted from this endpoint.
Type string or null
Read Only False
Added iLO6 1.05

Ethernet.LLDPTransmit.ManagementVlanId Member of Port.v1_12_0.Port

Description The management VLAN ID to be transmitted from this endpoint.
Type integer or null
Read Only False
Added iLO6 1.05

Ethernet.LLDPTransmit.PortId Member of Port.v1_12_0.Port

Description A colon delimited string of hexadecimal octets identifying a port to be transmitted from this endpoint.
Type string or null
Read Only False
Added iLO6 1.05

Ethernet.LLDPTransmit.PortIdSubtype Member of Port.v1_12_0.Port

Description The port ID subtype to be transmitted from this endpoint.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
ChassisComp Chassis component, based in the value of entPhysicalAlias in RFC4133.
IfAlias Interface alias, based on the ifAlias MIB object.
PortComp Port component, based in the value of entPhysicalAlias in RFC4133.
MacAddr MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802.
NetworkAddr Network address, based on an agent detected network address.
IfName Interface name, based on the ifName MIB object.
AgentId Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC3046.
LocalAssign Locally assigned, based on a alpha-numeric value locally assigned.
NotTransmitted No data to be sent to/received from remote partner.

Ethernet.LLDPTransmit.SystemCapabilities (array) Member of Port.v1_12_0.Port

SystemCapabilities is an array containing elements of:

SystemCapabilities[{item}] Member of Port.v1_12_0.Port

Type string
Read Only True
Added iLO6 1.63

The following are the supported values:

Value
None
Bridge
DOCSISCableDevice
Other
Repeater
Router
Station
Telephone
WLANAccessPoint

Ethernet.LLDPTransmit.SystemDescription Member of Port.v1_12_0.Port

Description The system description to be transmitted from this endpoint.
Type string or null
Read Only False
Added iLO6 1.63

Ethernet.LLDPTransmit.SystemName Member of Port.v1_12_0.Port

Description The system name to be transmitted from this endpoint.
Type string or null
Read Only False
Added iLO6 1.63

Ethernet.WakeOnLANEnabled Member of Port.v1_12_0.Port

Description Indicates whether Wake on LAN (WoL) is enabled on this port.
Type boolean or null
Read Only False
Added iLO6 1.05

FibreChannel

FibreChannel.AssociatedWorldWideNames (array) Member of Port.v1_12_0.Port

AssociatedWorldWideNames is an array containing elements of:

AssociatedWorldWideNames[{item}] Member of Port.v1_12_0.Port

Type string or null
Read Only True
Added iLO6 1.10

FibreChannel.FabricName Member of Port.v1_12_0.Port

Description The Fibre Channel Fabric Name provided by the switch.
Type string or null
Read Only True
Added iLO6 1.05

FibreChannel.NumberDiscoveredRemotePorts Member of Port.v1_12_0.Port

Description The number of ports not on the associated device that the associated device has discovered through this port.
Type integer or null
Read Only True
Added iLO6 1.05

FibreChannel.PortConnectionType Member of Port.v1_12_0.Port

Description The connection type of this port.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
NotConnected This port is not connected.
NPort This port connects through an N-Port to a switch.
PointToPoint This port connects in a Point-to-point configuration.
PrivateLoop This port connects in a private loop configuration.
PublicLoop This port connects in a public configuration.
Generic This port connection type is a generic fabric port.
ExtenderFabric This port connection type is an extender fabric port.
FPort This port connection type is a fabric port.
EPort This port connection type is an extender fabric port.
TEPort This port connection type is an trunking extender fabric port.
NPPort This port connection type is a proxy N port for N-Port virtualization.
GPort This port connection type is a generic fabric port.
NLPort This port connects in a node loop configuration.
FLPort This port connects in a fabric loop configuration.
EXPort This port connection type is an external fabric port.
UPort This port connection type is unassigned.
DPort This port connection type is a diagnostic port.

FunctionMaxBandwidth (array)

Member of Port.v1_12_0.Port

FunctionMaxBandwidth is an array containing elements of:

FunctionMaxBandwidth[{item}].AllocationPercent Member of Port.v1_12_0.Port

Description The maximum bandwidth allocation percentage allocated to the corresponding network device function instance.
Type integer or null
Read Only False
Added iLO6 1.05

FunctionMaxBandwidth[{item}].NetworkDeviceFunction The link to the network device function associated with this bandwidth setting of this network port. NetworkDeviceFunction is a link ("@odata.id": URI) to another resource.

FunctionMinBandwidth (array)

Member of Port.v1_12_0.Port

FunctionMinBandwidth is an array containing elements of:

FunctionMinBandwidth[{item}].AllocationPercent Member of Port.v1_12_0.Port

Description The minimum bandwidth allocation percentage allocated to the corresponding network device function instance.
Type integer or null
Read Only False
Added iLO6 1.05

FunctionMinBandwidth[{item}].NetworkDeviceFunction The link to the network device function associated with this bandwidth setting of this network port. NetworkDeviceFunction is a link ("@odata.id": URI) to another resource.

InterfaceEnabled

Member of Port.v1_12_0.Port

Description An indication of whether the interface is enabled.
Type boolean or null
Read Only False
Added iLO6 1.05

LinkConfiguration (array)

Member of Port.v1_12_0.Port

LinkConfiguration is an array containing elements of:

LinkConfiguration[{item}].AutoSpeedNegotiationCapable Member of Port.v1_12_0.Port

Description An indication of whether the port is capable of autonegotiating speed.
Type boolean or null
Read Only True
Added iLO6 1.05

LinkConfiguration[{item}].AutoSpeedNegotiationEnabled Member of Port.v1_12_0.Port

Description Controls whether this port is configured to enable autonegotiating speed.
Type boolean or null
Read Only False
Added iLO6 1.05

LinkConfiguration[{item}].CapableLinkSpeedGbps (array) Member of Port.v1_12_0.Port

CapableLinkSpeedGbps is an array containing elements of:

CapableLinkSpeedGbps[{item}] Member of Port.v1_12_0.Port

Type integer or null
Read Only True
Added iLO6 1.05

LinkConfiguration[{item}].ConfiguredNetworkLinks (array) Member of Port.v1_12_0.Port

ConfiguredNetworkLinks is an array containing elements of:

ConfiguredNetworkLinks[{item}].ConfiguredLinkSpeedGbps Member of Port.v1_12_0.Port

Description The link speed per lane this port is configured to use for autonegotiation.
Type integer or null
Read Only False
Added iLO6 1.05

ConfiguredNetworkLinks[{item}].ConfiguredWidth Member of Port.v1_12_0.Port

Description The link width this port is configured to use for autonegotiation in conjunction with the link speed.
Type integer or null
Read Only False
Added iLO6 1.05

LinkNetworkTechnology

Member of Port.v1_12_0.Port

Description The link network technology capabilities of this port.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Ethernet The port is capable of connecting to an Ethernet network.
InfiniBand The port is capable of connecting to an InfiniBand network.
FibreChannel The port is capable of connecting to a Fibre Channel network.
GenZ The port is capable of connecting to a Gen-Z fabric.

LinkState

Member of Port.v1_12_0.Port

Description The desired link state for this interface.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
Enabled This link is enabled.
Disabled This link is disabled.

LinkStatus

Member of Port.v1_12_0.Port

Description The desired link status for this interface.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
LinkUp This link on this interface is up.
Starting This link on this interface is starting. A physical link has been established, but the port is not able to transfer data.
Training This physical link on this interface is training.
LinkDown The link on this interface is down.
NoLink No physical link detected on this interface.

LinkTransitionIndicator

Member of Port.v1_12_0.Port

Description The number of link state transitions for this interface.
Type integer
Read Only False
Added iLO6 1.05

Location

Location.PartLocation Location.PartLocation.LocationOrdinalValue Member of Port.v1_12_0.Port

Description The number that represents the location of the part. If LocationType is slot and this unit is in slot 2, the LocationOrdinalValue is 2.
Type integer or null
Read Only True
Added iLO6 1.05

Location.PartLocation.LocationType Member of Port.v1_12_0.Port

Description The location types for PartLocation.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
Slot The slot as the type of location.
Bay The bay as the type of location.
Connector The connector as the type of location.
Socket The socket as the type of location.
Embedded Embedded within a part.

Location.PartLocation.Orientation Member of Port.v1_12_0.Port

Description The orientation for the ordering of the part location ordinal value.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
FrontToBack The ordering for LocationOrdinalValue is front to back.
BackToFront The ordering for the LocationOrdinalValue is back to front.
TopToBottom The ordering for the LocationOrdinalValue is top to bottom.
BottomToTop The ordering for LocationOrdinalValue is bottom to top.
LeftToRight The ordering for the LocationOrdinalValue is left to right.
RightToLeft The ordering for the LocationOrdinalValue is right to left.

Location.PartLocation.Reference Member of Port.v1_12_0.Port

Description The reference area for the location of the part.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
Top The part is in the top of the unit.
Bottom The part is in the bottom of the unit.
Front The part is in the front of the unit.
Rear The part is in the rear of the unit.
Left The part is on the left side of of the unit.
Right The part is on the right side of the unit.
Middle The part is in the middle of the unit.

Location.PartLocation.ServiceLabel Member of Port.v1_12_0.Port

Description The label of the part location, such as a silk-screened name or a printed label.
Type string or null
Read Only True
Added iLO6 1.05

Location.Placement Location.Placement.AdditionalInfo Member of Port.v1_12_0.Port

Description Area designation or other additional info.
Type string or null
Read Only False
Added iLO6 1.05

Location.Placement.Rack Member of Port.v1_12_0.Port

Description The name of a rack location within a row.
Type string or null
Read Only False
Added iLO6 1.05

Location.Placement.RackOffset Member of Port.v1_12_0.Port

Description The vertical location of the item, in terms of RackOffsetUnits.
Type integer or null
Read Only False
Added iLO6 1.05

Location.Placement.RackOffsetUnits Member of Port.v1_12_0.Port

Description The type of rack unit in use.
Type string or null
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
OpenU A rack unit that is equal to 48 mm (1.89 in).
EIA_310 A rack unit that is equal to 1.75 in (44.45 mm).

Location.Placement.Row Member of Port.v1_12_0.Port

Description The name of the row.
Type string or null
Read Only False
Added iLO6 1.05

LocationIndicatorActive

Member of Port.v1_12_0.Port

Description An indicator allowing an operator to physically locate this resource.
Type boolean or null
Read Only False
Added iLO6 1.05

MaxFrameSize

Member of Port.v1_12_0.Port

Description The maximum frame size supported by the port.
Type integer or null
Read Only True
Added iLO6 1.05

MaxSpeedGbps

Member of Port.v1_12_0.Port

Description The maximum speed of this port as currently configured.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.AutoNegotiationCapable

Member of Port.v1_12_0.Port

Description Indicates the ability of this network port to autonegotiate link speed.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.ConfiguredNetworkLinks (array)

Member of Port.v1_12_0.Port

ConfiguredNetworkLinks is an array containing elements of:

ConfiguredNetworkLinks[{item}].ConfiguredLinkSpeedGbps Member of Port.v1_12_0.Port

Description The link speed per lane this port is configured to use for autonegotiation.
Type integer or null
Read Only False
Added iLO6 1.05

ConfiguredNetworkLinks[{item}].ConfiguredWidth Member of Port.v1_12_0.Port

Description The number of lanes this port is configured to use for autonegotiation. If this property is omitted, the lane count shall default to one.
Type integer or null
Read Only False
Added iLO6 1.05

Oem.Hpe.EvbData

Oem.Hpe.EvbData.Receiving Oem.Hpe.EvbData.Receiving.CdcpActive Member of Port.v1_12_0.Port

Description True if a currently active IEEE 802.1Qbg CDCP TLV has been received from the link partner.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Receiving.ChannelActive Member of Port.v1_12_0.Port

Description A currently unexpired HPE Channel Link Control or HPE Channel Description TLV has been received from the link partner.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Receiving.ChannelDescriptionLocalSequenceNumber Member of Port.v1_12_0.Port

Description The link partner's HPE Channel Description sequence number that was last successfully received and processed.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Receiving.ChannelDescriptionRemoteSequenceNumber Member of Port.v1_12_0.Port

Description The last HPE Channel Decsription sequence number sent on this link that was successfully received and processed by the link partner.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Receiving.ChannelDescriptionSubtype Member of Port.v1_12_0.Port

Description The header subtype field of the last received HPE Channel Description TLV.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Receiving.ChannelLinkControlLocalSequenceNumber Member of Port.v1_12_0.Port

Description The link partner's HPE Channel Link Control sequence number that was last successfully received and processed.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Receiving.ChannelLinkControlMCEnable Member of Port.v1_12_0.Port

Description The Feature Indicators field, Management Controller (MC) Channel (SCID 4094) enabled state in the HPE CLC TLV being received from the link partner on this port.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Receiving.ChannelLinkControlRemoteSequenceNumber Member of Port.v1_12_0.Port

Description The last HPE Channel Link control sequence number sent on this link that was successfully received and processed by the link partner.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Receiving.ChannelLinkControlSubtype Member of Port.v1_12_0.Port

Description The header subtype field of the last received HPE Channel Link Control TLV.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Receiving.Role Member of Port.v1_12_0.Port

Description The link partner's IEEE 802.1Qbg operating role.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
bridge Indicates the link partner is operating as a Bridge.
station Indicates the link partner is operating as a Station.

Oem.Hpe.EvbData.Receiving.SChannelAssignments (array) Member of Port.v1_12_0.Port

SChannelAssignments is an array containing elements of:

SChannelAssignments[{item}].Scid Member of Port.v1_12_0.Port

Description SCID value for this <SCID,SVID> S-Channel identifier pairreceived from the link partner on this port.
Type integer or null
Read Only True
Added iLO6 1.05

SChannelAssignments[{item}].Svid Member of Port.v1_12_0.Port

Description SVID assignment value for this <SCID,SVID> S-Channel identifier pair received from the link partner on this port. When 0 it indicates an assignment request is in progress.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Receiving.SChannelMaxCount Member of Port.v1_12_0.Port

Description Indicates the number of S-Channels the link partner can support on this physical link.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Receiving.SChannelsSupported Member of Port.v1_12_0.Port

Description When true this link supports S-Channels.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Receiving.VirtualLinkStatusVector Member of Port.v1_12_0.Port

Description A bit vector indicating S-Channel status received from the link partner, 1=up, 0=down. S-Channel status bits are ordered by SCID from lowest numbered (first) to highest (last).
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Transmitting Oem.Hpe.EvbData.Transmitting.ChannelDescriptionData (array) Member of Port.v1_12_0.Port

ChannelDescriptionData is an array containing elements of:

ChannelDescriptionData[{item}].Descriptor0BandwidthCirMbps Member of Port.v1_12_0.Port

Description The bandwidth Commited Information Rate (CIR) for this S-Channel, in Mbps.
Type integer or null
Read Only True
Added iLO6 1.05

ChannelDescriptionData[{item}].Descriptor0BandwidthPirMbps Member of Port.v1_12_0.Port

Description The bandwidth Peak Information Rate (PIR) for this S-Channel, in Mbps.
Type integer or null
Read Only True
Added iLO6 1.05

ChannelDescriptionData[{item}].Descriptor0ChannelTerminationType Member of Port.v1_12_0.Port

Description Indicates the termination provided for this S-Channel.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
primary-physical This S-Channel is presented to the host OS as a primary PCI physical function.
SR-IOV-virtual This S-Channel is presented to the host OS as a PCI SR-IOV virtual function.
secondary-physical This S-Channel is presented to the host OS as a secondary PCI physical function, i.e. a PCI physical function behind a bridge on the device.
vSwitch-port This S-Channel is mapped to a Virtual Switch port.
NCSI-port This S-Channel is mapped to the NCSI internal port for management.

ChannelDescriptionData[{item}].Descriptor0EthernetSupport Member of Port.v1_12_0.Port

Description When true, this S-Channel supports Ethernet.
Type boolean or null
Read Only True
Added iLO6 1.05

ChannelDescriptionData[{item}].Descriptor0FCoESupport Member of Port.v1_12_0.Port

Description When true, this S-Channel supports Fibre Channel over Ethernet (FCoE).
Type boolean or null
Read Only True
Added iLO6 1.05

ChannelDescriptionData[{item}].Descriptor0PcpSupport Member of Port.v1_12_0.Port

Description Indicates which IEEE 802.1Q Ethernet Priority Code Point (PCP) classes are supported on this S-Channel. When no PCPs are supported, the S-Channel makes no attempt to filter or control traffic class. A string of 1/0 characters indicating 1=enabled, 0=disabled. PCP classes are ordered from highest numbered 7 (first) to lowest 0 (last).
Type string or null
Read Only True
Added iLO6 1.05

ChannelDescriptionData[{item}].Descriptor0RoCEESupport Member of Port.v1_12_0.Port

Description When true, this S-Channel supports RDMA over Converged Enhanced Ethernet (RoCEE).
Type boolean or null
Read Only True
Added iLO6 1.05

ChannelDescriptionData[{item}].Descriptor0Scid Member of Port.v1_12_0.Port

Description The S-Channel identifier for this Descriptor0 instance.
Type integer or null
Read Only True
Added iLO6 1.05

ChannelDescriptionData[{item}].Descriptor0iSCSISupport Member of Port.v1_12_0.Port

Description When true, this S-Channel supports Internet SCSI (iSCSI).
Type boolean or null
Read Only True
Added iLO6 1.05

ChannelDescriptionData[{item}].Descriptor1ConnectionID Member of Port.v1_12_0.Port

Description A unique S-Channel identifer in UUID format.
Type string or null
Read Only True
Added iLO6 1.05

ChannelDescriptionData[{item}].Descriptor1Scid Member of Port.v1_12_0.Port

Description The S-Channel identifier for this Descriptor1 instance.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Transmitting.ChannelDescriptionLocalSequenceNumber Member of Port.v1_12_0.Port

Description This station's channel discovery local sequence number which will be transmitted to the link partner on this port.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Transmitting.ChannelDescriptionRemoteSequenceNumber Member of Port.v1_12_0.Port

Description The link partner's channel discovery local sequence number that was last successfully received and processed.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Transmitting.ChannelDescriptorCount Member of Port.v1_12_0.Port

Description The number of channel descriptor pairs being transmitted to the link partner on this port.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Transmitting.ChannelLinkControlLocalSequenceNumber Member of Port.v1_12_0.Port

Description This station's channel link control local sequence number which will be transmitted to the link partner on this port.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Transmitting.ChannelLinkControlMCEnable Member of Port.v1_12_0.Port

Description The Feature Indicators field, Management Controller (MC) Channel (SCID 4094) enabled state in the HPE CLC TLV being transmitted to the link partner on this port.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Transmitting.ChannelLinkControlRemoteSequenceNumber Member of Port.v1_12_0.Port

Description The link partner's channel link control local sequence number that was last successfully received and processed.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Transmitting.Role Member of Port.v1_12_0.Port

Description This port's IEEE 802.1Qbg role being advertised on the link.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
bridge Indicates this link is operating locally as a Bridge.
station Indicates this link is operating locally as a Station.

Oem.Hpe.EvbData.Transmitting.SChannelAssignments (array) Member of Port.v1_12_0.Port

SChannelAssignments is an array containing elements of:

SChannelAssignments[{item}].Scid Member of Port.v1_12_0.Port

Description SCID value for this <SCID,SVID> S-Channel identifier pair being transmitted to the link partner on this port.
Type integer or null
Read Only True
Added iLO6 1.05

SChannelAssignments[{item}].Svid Member of Port.v1_12_0.Port

Description SVID assignment value for this <SCID,SVID> S-Channel identifier pair being transmitted to the link partner on this port. When 0 it indicates an SVID assignment request to the link partner is in progress.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Transmitting.SChannelMaxCount Member of Port.v1_12_0.Port

Description The Channel Capacity value being advertised to the link partner. It indicates the number of S-Channels this station can support on this physical link.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Transmitting.SChannelsSupported Member of Port.v1_12_0.Port

Description When true, indicates that this physical link has S-Channel capability.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.EvbData.Transmitting.VirtualLinkStatusVector Member of Port.v1_12_0.Port

Description A bit vector indicating S-Channel status being transmitted on this link, 1=up, 0=down. S-Channel status bits are ordered by SCID from lowest numbered (first) to highest (last).
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData

Oem.Hpe.LldpData.Receiving Oem.Hpe.LldpData.Receiving.ChassisID Member of Port.v1_12_0.Port

Description The LLDP chassis ID received from the link partner.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.ChassisIDSubtype Member of Port.v1_12_0.Port

Description The IEEE 802.1AB-2009 chassis ID subtype received from the link partner.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
ChassisComp Chassis component, based in the value of entPhysicalAlias in IETF RFC 4133.
IfAlias Interface alias, based on the IfAlias MIB object.
PortComp Port component, based in the value of entPhysicalAlias in IETF RFC 4133.
MacAddr MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802.
NetworkAddr Network address, based on an agent detected network address.
IfName Interface name, based on the IfName MIB object.
AgentId Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC 3046.
LocalAssign Locally assigned, based on a alpha-numeric value locally assigned.

Oem.Hpe.LldpData.Receiving.Dcb Oem.Hpe.LldpData.Receiving.Dcb.ApplicationPriorityReceived Member of Port.v1_12_0.Port

Description True when an unexpired Data Center Bridging (DCB) Application Priority Table TLV has been received.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.Dcb.ApplicationPriorityTable (array) Member of Port.v1_12_0.Port

ApplicationPriorityTable is an array containing elements of:

ApplicationPriorityTable[{item}].ApplicationPriority Member of Port.v1_12_0.Port

Description Indicates which priority level is assigned for this application protocol.
Type integer or null
Read Only True
Added iLO6 1.05

ApplicationPriorityTable[{item}].ApplicationProtocol Member of Port.v1_12_0.Port

Description An integer value indicating application protocol identity, of the type described by DCBApplicationSelect.
Type integer or null
Read Only True
Added iLO6 1.05

ApplicationPriorityTable[{item}].ApplicationSelect Member of Port.v1_12_0.Port

Description Indentifies the type of the DCBApplicationProtocol property.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
reserved Reserved select value.
default-Ethertype Default priority. Use when priority not otherwise specified.
TCP-SCTP DCBApplicationProtocol value is a well known port over TCP or SCTP.
UDP-DCCP DCBApplicationProtocol value is a well known port over UDP or DCCP.
TCP-SCTP-UDP-DCCP DCBApplicationProtocol is a well known port over TCP, SCTP, SCTP, or DCCP.

Oem.Hpe.LldpData.Receiving.Dcb.Ets Oem.Hpe.LldpData.Receiving.Dcb.Ets.BandwidthAssignmentTable (array) Member of Port.v1_12_0.Port

BandwidthAssignmentTable is an array containing elements of:

BandwidthAssignmentTable[{item}] Member of Port.v1_12_0.Port

Description One entry in the DCB ETS Traffic Class (TC) Bandwidth Assignment Table.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.Dcb.Ets.CreditBasedShaper Member of Port.v1_12_0.Port

Description True if the link partner supports the Credit-based Shaper (CBS) transmmission selection algortithm.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.Dcb.Ets.MaximumTrafficClassCount Member of Port.v1_12_0.Port

Description The maximum number of traffic classes supported by the link partner.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.Dcb.Ets.PriorityAssignmentTable (array) Member of Port.v1_12_0.Port

PriorityAssignmentTable is an array containing elements of:

PriorityAssignmentTable[{item}] Member of Port.v1_12_0.Port

Description One entry in the DCB ETS Priority Assignment Table indicating this priority's Traffic Class assignment.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.Dcb.Ets.TlvReceived Member of Port.v1_12_0.Port

Description True when an unexpired DCB Enhanced Transmission Selection (ETS) TLV has been received.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.Dcb.Ets.TrafficSelectionAlgorithmTable (array) Member of Port.v1_12_0.Port

TrafficSelectionAlgorithmTable is an array containing elements of:

TrafficSelectionAlgorithmTable[{item}] Member of Port.v1_12_0.Port

Description An assignment of a Traffic Selection Algorithm (TSA) to a traffic class.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
strict Strict priority algorithm.
CBS Credit-Based Shaper algorithm.
ETS Enhanced Traffic Selection algorithm.
vendor Vendor specific algorithm for use with DCB.

Oem.Hpe.LldpData.Receiving.Dcb.Ets.Willing Member of Port.v1_12_0.Port

Description True if the link partner is willing to accept ETS configurations.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.Dcb.LocalEqualRemote Member of Port.v1_12_0.Port

Description True when the transmitted and received contents match for both DCB ETS and PFC TLVs.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.Dcb.Pfc Oem.Hpe.LldpData.Receiving.Dcb.Pfc.EnabledTrafficClasses Member of Port.v1_12_0.Port

Description A bit string indicating which priority levels have PFC enabled, 1=enabled. PFC levels are bit ordered from 7 (first) to 0 (last).
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.Dcb.Pfc.MacSecurityBypassCapability Member of Port.v1_12_0.Port

Description True when the link partner has the ability to bypass MAC security in order to improve PFC responsiveness.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.Dcb.Pfc.MaximumTrafficClassCount Member of Port.v1_12_0.Port

Description Indicates the maximum number of traffic classes that the link partner can simultaneously support.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.Dcb.Pfc.TlvReceived Member of Port.v1_12_0.Port

Description True when an unexpired DCB Priority Flow Control (PFC) TLV has been received.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.Dcb.Pfc.Willing Member of Port.v1_12_0.Port

Description True if the LLDP link partner is willing to accept PFC configurations.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.Dcb.Version Member of Port.v1_12_0.Port

Description The DCB version supported by the link partner.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
unknown Unknown
CEE Converged Enhanced Ethernet
IEEE IEEE 802.1Q

Oem.Hpe.LldpData.Receiving.ManagementAddress Member of Port.v1_12_0.Port

Description The management address received from the link partner.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.ManagementAddressOID Member of Port.v1_12_0.Port

Description An object identifier for the hardware or protocol entity associated with the management address.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.ManagementAddressReceived Member of Port.v1_12_0.Port

Description True when a currently unexpired management address TLV has been received from the link partner.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.ManagementAddressType Member of Port.v1_12_0.Port

Description The type of management address received from the link partner.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
IPv4 Type 1 (IP version 4).
IPv6 Type 2 (IP version 6).
all802 Type 6 (All 802 media plus Ethernet 'canonical format').

Oem.Hpe.LldpData.Receiving.ManagementIFNumSubtype Member of Port.v1_12_0.Port

Description Management interface number subtype.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
unknown Interface number is not known.
ifIndex Interface number is based on the ifIndex MIB object.
sysPortNum Interface number is based on the system port numbering convention.

Oem.Hpe.LldpData.Receiving.ManagementIFNumber Member of Port.v1_12_0.Port

Description Management interface number received from the link partner represented as a colon delimited string of hexadecimal octets.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.ManagementVlanReceived Member of Port.v1_12_0.Port

Description True when a currently unexpired management address VID TLV has been received from the link partner.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.NearestBridgeTtlExpired Member of Port.v1_12_0.Port

Description True when the LLDP PDU most recently received from the link partner has expired.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.PortDescription Member of Port.v1_12_0.Port

Description The remote link partner's port description.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.PortID Member of Port.v1_12_0.Port

Description A colon delimited string of hexadecimal octets received from the link partner identifying its port.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Receiving.PortIDSubtype Member of Port.v1_12_0.Port

Description The port ID subtype enumeration from IEEE 802.1AB-2009 Table 8-3, which indicates the format for the PortID property.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
ChassisComp Chassis component, based in the value of entPhysicalAlias in IETF RFC 4133.
IfAlias Interface alias, based on the IfAlias MIB object.
PortComp Port component, based in the value of entPhysicalAlias in IETF RFC 4133.
MacAddr MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802.
NetworkAddr Network address, based on an agent detected network address.
IfName Interface name, based on the IfName MIB object.
AgentId Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC 3046.
LocalAssign Locally assigned, based on a alpha-numeric value locally assigned.

Oem.Hpe.LldpData.Receiving.SystemDescription Member of Port.v1_12_0.Port

Description The system description received from the link partner.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Transmitting Oem.Hpe.LldpData.Transmitting.ChassisID Member of Port.v1_12_0.Port

Description The Link Layer Data Protocol (LLDP) chassis ID being transmitted on this link.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Transmitting.ChassisIDSubtype Member of Port.v1_12_0.Port

Description The IEEE 802.1AB-2009 chassis ID subtype being transmitted on this link.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
ChassisComp Chassis component, based in the value of entPhysicalAlias in IETF RFC 4133.
IfAlias Interface alias, based on the IfAlias MIB object.
PortComp Port component, based in the value of entPhysicalAlias in IETF RFC 4133.
MacAddr MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802.
NetworkAddr Network address, based on an agent detected network address.
IfName Interface name, based on the IfName MIB object.
AgentId Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC 3046.
LocalAssign Locally assigned, based on a alpha-numeric value locally assigned.

Oem.Hpe.LldpData.Transmitting.ManagementAddresses (array) Member of Port.v1_12_0.Port

ManagementAddresses is an array containing elements of:

ManagementAddresses[{item}].ManagementIPAddress Member of Port.v1_12_0.Port

Description A management address.
Type string or null
Read Only True
Added iLO6 1.05

ManagementAddresses[{item}].ManagementIPAddressType Member of Port.v1_12_0.Port

Description The IANA type of this management address.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
IPv4 Type 1 (IP version 4).
IPv6 Type 2 (IP version 6).
all802 Type 6 (All 802 media plus Ethernet 'canonical format').

Oem.Hpe.LldpData.Transmitting.ManagementCvlanIDTransmitted Member of Port.v1_12_0.Port

Description When true, indicates that a management CVLAN ID is being transmitted on this link.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Transmitting.PortDescription Member of Port.v1_12_0.Port

Description An alphanumeric string describing this link.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Transmitting.PortID Member of Port.v1_12_0.Port

Description A colon delimited string of hexadecimal octets identifying this port.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.LldpData.Transmitting.PortIDSubtype Member of Port.v1_12_0.Port

Description The port ID subtype from IEEE 802.1AB-2009 Table 8-3.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
ChassisComp Chassis component, based in the value of entPhysicalAlias in IETF RFC 4133.
IfAlias Interface alias, based on the IfAlias MIB object.
PortComp Port component, based in the value of entPhysicalAlias in IETF RFC 4133.
MacAddr MAC address, based on an agent detected unicast source address as defined in IEEE Std. 802.
NetworkAddr Network address, based on an agent detected network address.
IfName Interface name, based on the IfName MIB object.
AgentId Agent circuit ID, based on the agent-local identifier of the circuit as defined in RFC 3046.
LocalAssign Locally assigned, based on a alpha-numeric value locally assigned.

Oem.Hpe.LldpData.Transmitting.SystemDescription Member of Port.v1_12_0.Port

Description A textual description of this system.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.PortDiagnosticEnableLocalLoopback

Member of Port.v1_12_0.Port

Description When true, local loopback is active on this port. PortDiagnosticsEnabled must first be true in order to set this property to true.
Type boolean or null
Read Only False
Added iLO6 1.05

Oem.Hpe.PortDiagnosticEnableRemoteLoopback

Member of Port.v1_12_0.Port

Description When true, remote loopback is active on this port. PortDiagnosticsEnabled must first be true in order to set this property to true.
Type boolean or null
Read Only False
Added iLO6 1.05

Oem.Hpe.PortDiagnosticLocalLoopbackCapable

Member of Port.v1_12_0.Port

Description When true, the port has local loopback capability.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.PortDiagnosticRemoteLoopbackCapable

Member of Port.v1_12_0.Port

Description When true, the port has remote loopback capability.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.PortDiagnosticsEnabled

Member of Port.v1_12_0.Port

Description When true, diagnostic features are enabled on this port.
Type boolean or null
Read Only False
Added iLO6 1.05

Oem.Hpe.VirtualFunctionAllocations (array)

Member of Port.v1_12_0.Port

VirtualFunctionAllocations is an array containing elements of:

VirtualFunctionAllocations[{item}].NetworkDeviceFunction The logical network device function to which this virtual function allocation applies. NetworkDeviceFunction is a link ("@odata.id": URI) to another resource.

VirtualFunctionAllocations[{item}].VirtualFunctionsAllocated Member of Port.v1_12_0.Port

Description The number of virtual functions allocated to this logical network device function instance.
Type integer or null
Read Only False
Added iLO6 1.05

PortId

Member of Port.v1_12_0.Port

Description The label of this port on the physical package for this port.
Type string or null
Read Only True
Added iLO6 1.05

PortMedium

Member of Port.v1_12_0.Port

Description The physical connection medium for this port.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Electrical This port has an electrical cable connection.
Optical This port has an optical cable connection.

PortProtocol

Member of Port.v1_12_0.Port

Description The protocol being sent over this port.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Ethernet Ethernet.
FC Fibre Channel.
FCoE Fibre Channel over Ethernet (FCoE).
GenZ GenZ.
InfiniBand InfiniBand.
SAS Serial Attached SCSI.
MultiProtocol Multiple Protocols.
PCIe PCI Express.
AHCI Advanced Host Controller Interface (AHCI).
UHCI Universal Host Controller Interface (UHCI).
SATA Serial AT Attachment.
USB Universal Serial Bus (USB).
NVMe Non-Volatile Memory Express (NVMe).
iSCSI Internet SCSI.
FCP Fibre Channel Protocol for SCSI.
FICON FIbre CONnection (FICON).
NVMeOverFabrics NVMe over Fabrics.
SMB Server Message Block (SMB). Also known as the Common Internet File System (CIFS).
NFSv3 Network File System (NFS) version 3.
NFSv4 Network File System (NFS) version 4.
HTTP Hypertext Transport Protocol (HTTP).
HTTPS Hypertext Transfer Protocol Secure (HTTPS).
FTP File Transfer Protocol (FTP).
SFTP SSH File Transfer Protocol (SFTP).
iWARP Internet Wide Area RDMA Protocol (iWARP).
RoCE RDMA over Converged Ethernet Protocol.
RoCEv2 RDMA over Converged Ethernet Protocol Version 2.
I2C Inter-Integrated Circuit Bus.
TCP Transmission Control Protocol (TCP).
UDP User Datagram Protocol (UDP).
TFTP Trivial File Transfer Protocol (TFTP).
NVLink NVLink.
OEM OEM-specific.
DisplayPort DisplayPort.
HDMI HDMI.
VGA VGA.
DVI DVI.

PortType

Member of Port.v1_12_0.Port

Description The type of this port.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
UpstreamPort This port connects to a host device.
DownstreamPort This port connects to a target device.
InterswitchPort This port connects to another switch.
ManagementPort This port connects to a switch manager.
BidirectionalPort This port connects to any type of device.
UnconfiguredPort This port has not yet been configured.

SignalDetected

Member of Port.v1_12_0.Port

Description An indication of whether a signal is detected on this interface.
Type boolean or null
Read Only True
Added iLO6 1.05

Status

Member of Port.v1_12_0.Port See the Redfish standard schema and specification for information on common Status object.

Width

Member of Port.v1_12_0.Port

Description The number of lanes, phys, or other physical transport links that this port contains.
Type integer or null
Read Only True
Added iLO6 1.05

Actions

Port.Reset Member of Port.v1_12_0.Port

Parameters:

target (string)

Link to invoke action

ResetValue (string)

Reset Port

Value Description
GracefulRestart Shut down gracefully and restart the system.
GracefulShutdown Shut down gracefully and power off.
PowerCycle Power cycle the unit. Behaves like a full power removal, followed by a power restore to the resource.
On Turn on the unit.
ForceOff Turn off the unit immediately (non-graceful shutdown).
PushPowerButton Simulate the pressing of the physical power button on this unit.
ForceOn Turn on the unit immediately.
ForceRestart Shut down immediately and non-gracefully and restart the system.
Nmi Generate a diagnostic interrupt, which is usually an NMI on x86 systems, to stop normal operations, complete diagnostic actions, and, typically, halt the system.

PortCollection

@odata.type: "#PortCollection.PortCollection"

A Collection of Port resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/networkadapters/{item}/ports GET
/redfish/v1/fabrics/{item}/switches/{item}/Ports GET
/redfish/v1/managers/{item}/dedicatednetworkports GET
/redfish/v1/managers/{item}/sharednetworkports GET
/redfish/v1/systems/{item}/networkinterfaces/{item}/ports GET POST PATCH
/redfish/v1/systems/{item}/storage/{item}/storagecontrollers/{item}/ports GET POST

Links to other Resources

Link Name Destination type
Members[] Port

Members (array)

Member of PortCollection.PortCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of PortCollection.PortCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of PortCollection.PortCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

Power

@odata.type: "#Power.v1_7_1.Power"

The Power resource describes the Power Metrics. It represents the properties for Power Consumption and Power Limiting.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/power GET PATCH

Links to other Resources

Link Name Destination type
Oem/Hpe/Links/FederatedGroupCapping HpeiLOFederatedGroupCapping
Oem/Hpe/Links/PowerMeter HpePowerMeter
Redundancy[]/RedundancySet[] Power
Oem/Hpe/Links/FastPowerMeter HpePowerMeter

Oem.Hpe.BatteryBackedUnits (array)

Member of Power.v1_7_1.Power

BatteryBackedUnits is an array containing elements of:

BatteryBackedUnits[{item}].BBUStatus BatteryBackedUnits[{item}].BBUStatus.Health Member of Power.v1_7_1.Power

Description This represents the health state of this resource in the absence of its dependent resources.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
OK Normal
Warning A condition exists that requires attention
Critical A critical condition exists that requires immediate attention

BatteryBackedUnits[{item}].BBUStatus.HealthRollup Member of Power.v1_7_1.Power

Description This represents the overall health state from the view of this resource.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
OK Normal
Warning A condition exists that requires attention
Critical A critical condition exists that requires immediate attention

BatteryBackedUnits[{item}].BBUStatus.State Member of Power.v1_7_1.Power

Description This indicates the known state of the resource, such as if it is enabled.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
Enabled This function or resource has been enabled.
Disabled This function or resource has been disabled.
StandbyOffline This function or resource is enabled, but awaiting an external action to activate it.
StandbySpare This function or resource is part of a redundancy set and is awaiting a failover or other external action to activate it.
InTest This function or resource is undergoing testing.
Starting This function or resource is starting.
Absent This function or resource is not present or not detected.
UnavailableOffline This function or resource is present but cannot be used.
Deferring The element will not process any commands but will queue new requests.
Quiesced The element is enabled but only processes a restricted set of commands.
Updating The element is updating and may be unavailable or degraded.

BatteryBackedUnits[{item}].BayNumber Member of Power.v1_7_1.Power

Description Bay number of the battery backed unit.
Type integer
Read Only True
Added iLO6 1.05

BatteryBackedUnits[{item}].CapacityWatts Member of Power.v1_7_1.Power

Description Total capacity (in Watts) of the battery backed unit.
Type integer
Read Only True
Added iLO6 1.05

BatteryBackedUnits[{item}].CutOffSetPointmAh Member of Power.v1_7_1.Power

Description Cut off threshold (mAh) where battery backed unit stops supplying power to the server.
Type integer
Read Only True
Added iLO6 1.05

BatteryBackedUnits[{item}].FirmwareVersion Member of Power.v1_7_1.Power

Description Firmware version of the battery backed unit.
Type string
Read Only True
Added iLO6 1.05

BatteryBackedUnits[{item}].PercentCharge Member of Power.v1_7_1.Power

Description Percentage charge remaining for the battery backed unit.
Type integer
Read Only True
Added iLO6 1.05

BatteryBackedUnits[{item}].RemainingCapacitymAh Member of Power.v1_7_1.Power

Description Remaining capacity (mAh) of the battery backed unit.
Type integer
Read Only True
Added iLO6 1.05

BatteryBackedUnits[{item}].SerialNumber Member of Power.v1_7_1.Power

Description Serial number of the battery backed unit.
Type string
Read Only True
Added iLO6 1.05

BatteryBackedUnits[{item}].TimeToCutOffSeconds Member of Power.v1_7_1.Power

Description Run time (in seconds) available with the battery backed unit until cut off. This is detected only when battery is charging or discharging, otherwise set to 0.
Type integer
Read Only True
Added iLO6 1.05

BatteryBackedUnits[{item}].TimeToFullChargeMinutes Member of Power.v1_7_1.Power

Description Time required (in minutes) to fully charge the battery backed unit. This is detected only when battery is charging or discharging, otherwise set to 0.
Type integer
Read Only True
Added iLO6 1.05

BatteryBackedUnits[{item}].UsableCapacitymAh Member of Power.v1_7_1.Power

Description Usable capacity (mAh) of the battery backed unit.
Type integer
Read Only True
Added iLO6 1.05

Oem.Hpe.BbuPowerSupply

Member of Power.v1_7_1.Power

Description Battery Backup Unit Power Supply action determines what will occur when a server is running on battery power.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
DoNothing No action will be taken when a server switches to battery power.
MomentaryPowerButtonPress Momentary virtual power button press which should shutdown host operating system when pressed.
HostShutdown Shutdown message sent to host operating system with installed management software to initiate a shutdown.

Oem.Hpe.BrownoutRecoveryEnabled

Member of Power.v1_7_1.Power

Description When a brownout condition occurs in the server, this setting will determine if the server should recover from it.
Type boolean or null
Read Only False
Added iLO6 1.05

Oem.Hpe.Domains (array)

Member of Power.v1_7_1.Power

Domains is an array containing elements of:

Domains[{item}].DomainName Member of Power.v1_7_1.Power

Description Power Supply Domain Name.
Type string
Read Only True
Added iLO6 1.10

The following are the supported values:

Value
System
GPU
GPU1
GPU2

Domains[{item}].HighEfficiencyMode Member of Power.v1_7_1.Power

Description The redundant power supply mode that will be used when redundant power supplies are configured.
Type string or null
Read Only True
Added iLO6 1.10

The following are the supported values:

Value
Null
Auto
Balanced
Even
Odd
NoSupport

Domains[{item}].PowerSupplies (array) Member of Power.v1_7_1.Power

PowerSupplies is an array containing elements of:

PowerSupplies[{item}].@odata.id Member of Power.v1_7_1.Power

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Domains[{item}].PowerSupplyRedundancy Member of Power.v1_7_1.Power

Description This indicates if the Power Supply is redundant or not.
Type string
Read Only True
Added iLO6 1.10

The following are the supported values:

Value Description
Redundant The power supplies are Redundant.
NonRedundant The power supplies are not Redundant.
FailedRedundant The Redundant power supply has failed.
Unknown The Redundant state is unknown.

Domains[{item}].Status Member of Power.v1_7_1.Power See the Redfish standard schema and specification for information on common Status object.

Oem.Hpe.FanPowerRequirement

Member of Power.v1_7_1.Power

Description Cooling challenge bucket definition.
Type integer
Read Only True
Added iLO6 1.05

Oem.Hpe.FanPowerRequirementErrors

Member of Power.v1_7_1.Power

Description Cooling challenge errors.
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.FanPowerRequirementVersion

Member of Power.v1_7_1.Power

Description Version of the Synergy cooling table bucket definitions.
Type integer
Read Only True
Added iLO6 1.05

Oem.Hpe.HasCpuPowerMetering

Member of Power.v1_7_1.Power

Description Indicates if the system has CPU power metering.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.HasDimmPowerMetering

Member of Power.v1_7_1.Power

Description Indicates if the system has DIMM power metering.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.HasFanPowerMetering

Member of Power.v1_7_1.Power

Description Indicates if the system has fan power metering.
Type boolean
Read Only True
Added iLO6 1.63

Oem.Hpe.HasGpuPowerMetering

Member of Power.v1_7_1.Power

Description Indicates if the system has GPU power metering.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.HasPowerMetering

Member of Power.v1_7_1.Power

Description Indicates if the system has power metering.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.HighEfficiencyMode

Member of Power.v1_7_1.Power

Description The redundant power supply mode that will be used when redundant power supplies are configured.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
Null
Auto
Balanced
Even
Odd
NoSupport

Oem.Hpe.MinimumSafelyAchievableCap

Member of Power.v1_7_1.Power

Description Minimum Safely Achievable Cap is the lowest cap value that is safe for a group power manager to apply to a particular server. It can either be identical to or slightly greater than the 0 percent cap value calculated during ROM power burn.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.MinimumSafelyAchievableCapValid

Member of Power.v1_7_1.Power

Description Indicates if the msac is valid. msac is valid only if this is true.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.PowerMetric

Oem.Hpe.PowerMetric.AmbTemp Member of Power.v1_7_1.Power

Description Ambient temperature, in degrees Celsius.
Type integer or null
Read Only True
Added iLO6 1.51

Oem.Hpe.PowerMetric.Cap Member of Power.v1_7_1.Power

Description The applicable power cap in Watts at the time of this power sample.
Type integer or null
Read Only True
Added iLO6 1.51

Oem.Hpe.PowerMetric.CpuCapLim Member of Power.v1_7_1.Power

Description Measures the effect of the power cap on performance in percent.
Type integer or null
Read Only True
Added iLO6 1.51

Oem.Hpe.PowerMetric.CpuMax Member of Power.v1_7_1.Power

Description The percentage of time the CPU spent in its maximum power mode.
Type integer or null
Read Only True
Added iLO6 1.51

Oem.Hpe.PowerMetric.CpuPwrSavLim Member of Power.v1_7_1.Power

Description Measures the effect of CPU Power Regulator state switching on performance in percent.
Type integer or null
Read Only True
Added iLO6 1.51

Oem.Hpe.PowerMetric.CpuWatts Member of Power.v1_7_1.Power

Description The power consumed by the system CPUs in Watts.
Type integer or null
Read Only True
Added iLO6 1.51

Oem.Hpe.PowerMetric.DimmWatts Member of Power.v1_7_1.Power

Description The power consumed by the system memory DIMMs in Watts.
Type integer or null
Read Only True
Added iLO6 1.51

Oem.Hpe.PowerMetric.GpuWatts Member of Power.v1_7_1.Power

Description The power consumed by the GPU(s) in Watts. This will be 0 if no GPUs are installed or if the drivers are not loaded.
Type integer or null
Read Only True
Added iLO6 1.51

Oem.Hpe.PowerMetric.PrMode Member of Power.v1_7_1.Power

Description Power Regulator mode, which can be OS Control, Static High, Static Low or Dynamic.
Type string or null
Read Only True
Added iLO6 1.51

The following are the supported values:

Value Description
Null A value is temporarily unavailable
dyn Dynamic Mode - CPU power regulation is managed dynamically by the firmware.
min Minimum Mode - CPU power regulation is configured to save as much power as possible at the possible expense of performance.
max Maximum Mode - CPU power regulation is configured for maximum performance at the possible expense of power efficiency.
osc OS Control Mode - CPU power regulation is managed by the Operating System.

Oem.Hpe.PowerMetric.PunCap Member of Power.v1_7_1.Power

Description If true, CPU performance is being penalized by the current power cap.
Type boolean or null
Read Only True
Added iLO6 1.51

Oem.Hpe.PowerMetric.UnachCap Member of Power.v1_7_1.Power

Description If true, the configured power cap could not be achieved due to system power requirements.
Type boolean or null
Read Only True
Added iLO6 1.51

Oem.Hpe.SNMPPowerThresholdAlert

Oem.Hpe.SNMPPowerThresholdAlert.DurationInMin Member of Power.v1_7_1.Power

Description Sets the length of time, in minutes, that power consumption must remain above the warning threshold before an SNMP alert is triggered. The maximum duration is 240 minutes, and the duration must be a multiple of 5.
Type integer
Read Only False
Added iLO6 1.05

Oem.Hpe.SNMPPowerThresholdAlert.ThresholdWatts Member of Power.v1_7_1.Power

Description Sets the power consumption threshold (watts). If power consumption exceeds this value for the specified time duration, an SNMP alert is triggered.
Type integer
Read Only False
Added iLO6 1.05

Oem.Hpe.SNMPPowerThresholdAlert.Trigger Member of Power.v1_7_1.Power

Description Trigger determines whether alerts are based on peak power consumption, average power consumption, or if they are disabled. Trigger property can only be enabled if the ThresholdWatts and DurationInMin values are specified/configured.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value
Disabled
AveragePowerConsumption
PeakPowerConsumption

PowerControl (array)

Member of Power.v1_7_1.Power

PowerControl is an array containing elements of:

PowerControl[{item}].@odata.id Member of Power.v1_7_1.Power

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

PowerControl[{item}].MemberId Member of Power.v1_7_1.Power

Description This is the identifier for the member within the collection.
Type string
Read Only True
Added iLO6 1.05

PowerControl[{item}].PowerAllocatedWatts Member of Power.v1_7_1.Power

Description The total amount of power that has been allocated (or budegeted)to chassis resources.
Type integer or null
Read Only True
Added iLO6 1.05

PowerControl[{item}].PowerAvailableWatts Member of Power.v1_7_1.Power

Description The amount of power not already budgeted and therefore available for additional allocation. (powerCapacity - powerAllocated). This indicates how much reserve power capacity is left.
Type integer or null
Read Only True
Added iLO6 1.05

PowerControl[{item}].PowerCapacityWatts Member of Power.v1_7_1.Power

Description The total amount of power available to the chassis for allocation. This may the power supply capacity, or power budget assigned to the chassis from an up-stream chassis.
Type integer or null
Read Only True
Added iLO6 1.05

PowerControl[{item}].PowerConsumedWatts Member of Power.v1_7_1.Power

Description The actual power being consumed by the chassis.
Type integer or null
Read Only True
Added iLO6 1.05

PowerControl[{item}].PowerLimit PowerControl[{item}].PowerLimit.CorrectionInMs Member of Power.v1_7_1.Power

Description The time required for the limiting process to reduce power consumption to below the limit.
Type integer or null
Read Only True
Added iLO6 1.05

PowerControl[{item}].PowerLimit.LimitException Member of Power.v1_7_1.Power

Description The action that is taken if the power cannot be maintained below the LimitInWatts.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
NoAction Take no action when the limit is exceeded.
HardPowerOff Turn the power off immediately when the limit is exceeded.
LogEventOnly Log an event when the limit is exceeded, but take no further action.
Oem Take an OEM-defined action.

PowerControl[{item}].PowerLimit.LimitInWatts Member of Power.v1_7_1.Power

Description The Power limit in watts. Set to null to disable power capping.
Type integer or null
Read Only False
Added iLO6 1.05

PowerControl[{item}].PowerMetrics PowerControl[{item}].PowerMetrics.AverageConsumedWatts Member of Power.v1_7_1.Power

Description The average power level over the measurement window (the last IntervalInMin minutes).
Type integer or null
Read Only True
Added iLO6 1.05

PowerControl[{item}].PowerMetrics.IntervalInMin Member of Power.v1_7_1.Power

Description The time interval (or window) in which the PowerMetrics are measured over.
Type integer or null
Read Only True
Added iLO6 1.05

PowerControl[{item}].PowerMetrics.MaxConsumedWatts Member of Power.v1_7_1.Power

Description The highest power consumption level that has occured over the measurement window (the last IntervalInMin minutes).
Type integer or null
Read Only True
Added iLO6 1.05

PowerControl[{item}].PowerMetrics.MinConsumedWatts Member of Power.v1_7_1.Power

Description The lowest power consumption level over the measurement window (the last IntervalInMin minutes).
Type integer or null
Read Only True
Added iLO6 1.05

PowerControl[{item}].PowerRequestedWatts Member of Power.v1_7_1.Power

Description The potential power that the chassis resources are requesting which may be higher than the current level being consumed since requested power includes budget that the chassis resource wants for future use.
Type integer or null
Read Only True
Added iLO6 1.05

PowerControl[{item}].RelatedItem (array) Member of Power.v1_7_1.Power

RelatedItem is an array containing elements of:

RelatedItem[{item}].@odata.id Member of Power.v1_7_1.Power

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

PowerControl[{item}].Status Member of Power.v1_7_1.Power See the Redfish standard schema and specification for information on common Status object.

PowerSupplies (array)

Member of Power.v1_7_1.Power

PowerSupplies is an array containing elements of:

PowerSupplies[{item}].@odata.id Member of Power.v1_7_1.Power

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

PowerSupplies[{item}].FirmwareVersion Member of Power.v1_7_1.Power

Description The firmware version for this Power Supply
Type string or null
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].LastPowerOutputWatts Member of Power.v1_7_1.Power

Description The average power output of this Power Supply
Type integer or null
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].LineInputVoltage Member of Power.v1_7_1.Power

Description The line input voltage at which the Power Supply is operating
Type integer or null
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].LineInputVoltageType Member of Power.v1_7_1.Power

Description The line voltage type supported as an input to this Power Supply
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
Unknown The power supply line input voltage type cannot be determined.
ACLowLine 100-127V AC input.
ACMidLine 200-240V AC input.
ACHighLine 277V AC input.
DCNeg48V -48V DC input.
HighVoltageDC High Voltage DC input (380V).

PowerSupplies[{item}].Manufacturer Member of Power.v1_7_1.Power

Description This is the manufacturer of this power supply.
Type string or null
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].MemberId Member of Power.v1_7_1.Power

Description This is the identifier for the member within the collection.
Type string
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].Model Member of Power.v1_7_1.Power

Description The model number for this Power Supply
Type string or null
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].Oem.Hpe.AveragePowerOutputWatts Member of Power.v1_7_1.Power

Description The latest observed average power being drawn by the power supply (Watts). This is usually updated every 10 seconds but the period can vary in some circumstances.
Type integer
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].Oem.Hpe.BayNumber Member of Power.v1_7_1.Power

Description The power supply bay number.
Type integer
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].Oem.Hpe.Domain Member of Power.v1_7_1.Power

Description This indicates the domain of the specific power supply.
Type string
Read Only True
Added iLO6 1.10

The following are the supported values:

Value
System
GPU

PowerSupplies[{item}].Oem.Hpe.HotplugCapable Member of Power.v1_7_1.Power

Description If true, this power supply (and power supply bay) is capable of being hot-plugged.
Type boolean
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].Oem.Hpe.MaxPowerOutputWatts Member of Power.v1_7_1.Power

Description The latest observed maximum output power being drawn by the power supply (Watts). This is usually updated every 10 seconds but the period can vary in some circumstances.
Type integer
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].Oem.Hpe.Mismatched Member of Power.v1_7_1.Power

Description If true, this power supply is mismatched with others in the system.
Type boolean
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].Oem.Hpe.PowerSupplyStatus PowerSupplies[{item}].Oem.Hpe.PowerSupplyStatus.State Member of Power.v1_7_1.Power

Description Indicates the known state of the resource.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
Unknown
Ok
Degraded
Failed
OverVoltage
OverCurrent
OverTemperature
ACPowerLost
FanFailure
WarningHighInputVoltage
WarningLowInputVoltage
WarningHighOutputVoltage
WarningLowOutputVoltage
WarningInletTemperature
WarningInternalTemperature
WarningHighAuxiliaryVoltage
WarningLowAuxiliaryVoltage
PowerSupplyMismatch
GoodInStandby

PowerSupplies[{item}].Oem.Hpe.iPDU PowerSupplies[{item}].Oem.Hpe.iPDU.IPAddress Member of Power.v1_7_1.Power

Description The IP address of the iPDU connected to this power supply.
Type string or null
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].Oem.Hpe.iPDU.MacAddress Member of Power.v1_7_1.Power

Description The Ethernet MAC address of the iPDU connected to this power supply.
Type string or null
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].Oem.Hpe.iPDU.Model Member of Power.v1_7_1.Power

Description The model number of the iPDU connected to this power supply.
Type string
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].Oem.Hpe.iPDU.SerialNumber Member of Power.v1_7_1.Power

Description The serial number of the iPDU connected to this power supply.
Type string
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].Oem.Hpe.iPDU.iPDUStatus PowerSupplies[{item}].Oem.Hpe.iPDU.iPDUStatus.State Member of Power.v1_7_1.Power

Description Indicates the known state of the resource.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
Unknown
Ok
Degraded
Failed
OverVoltage
OverCurrent
OverTemperature
ACPowerLost
FanFailure
WarningHighInputVoltage
WarningLowInputVoltage
WarningHighOutputVoltage
WarningLowOutputVoltage
WarningInletTemperature
WarningInternalTemperature
WarningHighAuxiliaryVoltage
WarningLowAuxiliaryVoltage
PowerSupplyMismatch
GoodInStandby

PowerSupplies[{item}].Oem.Hpe.iPDUCapable Member of Power.v1_7_1.Power

Description If true, this power supply is capable of being connected to an iPDUs.
Type boolean
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].PartNumber Member of Power.v1_7_1.Power

Description The part number for this Power Supply
Type string or null
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].PowerCapacityWatts Member of Power.v1_7_1.Power

Description The maximum capacity of this Power Supply
Type integer or null
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].PowerSupplyType Member of Power.v1_7_1.Power

Description The Power Supply type (AC or DC)
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
Unknown The power supply type cannot be determined
AC Alternating Current (AC) power supply
DC Direct Current (DC) power supply

PowerSupplies[{item}].Redundancy Member of Power.v1_7_1.Power See the Redfish standard schema and specification for information on common Redundancy object.

PowerSupplies[{item}].RelatedItem (array) Member of Power.v1_7_1.Power

RelatedItem is an array containing elements of:

RelatedItem[{item}].@odata.id Member of Power.v1_7_1.Power

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

PowerSupplies[{item}].SerialNumber Member of Power.v1_7_1.Power

Description The serial number for this Power Supply
Type string or null
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].SparePartNumber Member of Power.v1_7_1.Power

Description The spare part number for this Power Supply
Type string or null
Read Only True
Added iLO6 1.05

PowerSupplies[{item}].Status Member of Power.v1_7_1.Power See the Redfish standard schema and specification for information on common Status object.

Redundancy

Member of Power.v1_7_1.Power See the Redfish standard schema and specification for information on common Redundancy object.

Status

Member of Power.v1_7_1.Power See the Redfish standard schema and specification for information on common Status object.

Voltages (array)

Member of Power.v1_7_1.Power

Voltages is an array containing elements of:

Voltages[{item}].@odata.id Member of Power.v1_7_1.Power

Type string
Read Only True
Added iLO6 1.57
Format uri-reference

Voltages[{item}].LowerThresholdCritical Member of Power.v1_7_1.Power

Description Below normal range but not yet fatal.
Type number or null
Read Only True
Added iLO6 1.57

Voltages[{item}].LowerThresholdFatal Member of Power.v1_7_1.Power

Description Below normal range and is fatal
Type number or null
Read Only True
Added iLO6 1.57

Voltages[{item}].LowerThresholdNonCritical Member of Power.v1_7_1.Power

Description Below normal range
Type number or null
Read Only True
Added iLO6 1.57

Voltages[{item}].MaxReadingRange Member of Power.v1_7_1.Power

Description Maximum value for CurrentReading
Type integer or null
Read Only True
Added iLO6 1.57

Voltages[{item}].MemberId Member of Power.v1_7_1.Power

Description This is the identifier for the member within the collection.
Type string
Read Only True
Added iLO6 1.57

Voltages[{item}].MinReadingRange Member of Power.v1_7_1.Power

Description Minimum value for CurrentReading
Type integer or null
Read Only True
Added iLO6 1.57

Voltages[{item}].PhysicalContext Member of Power.v1_7_1.Power

Description Describes the area or device to which this voltage measurement applies.
Type string or null
Read Only True
Added iLO6 1.57

The following are the supported values:

Value Description
Null A value is temporarily unavailable
Room The room
Intake The intake point of the chassis
Exhaust The exhaust point of the chassis
Front The front of the chassis
Back The back of the chassis
Upper The upper portion of the chassis
Lower The lower portion of the chassis
CPU A Processor (CPU)
GPU A Graphics Processor (GPU)
Backplane A backplane within the chassis
SystemBoard The system board (PCB)
PowerSupply A power supply
VoltageRegulator A voltage regulator device
StorageDevice A storage device
NetworkingDevice A networking device
ComputeBay Within a compute bay
StorageBay Within a storage bay
NetworkBay Within a networking bay
ExpansionBay Within an expansion bay
PowerSupplyBay Within a power supply bay

Voltages[{item}].ReadingVolts Member of Power.v1_7_1.Power

Description The current value of the voltage sensor.
Type number or null
Read Only True
Added iLO6 1.57

Voltages[{item}].RelatedItem (array) Member of Power.v1_7_1.Power

RelatedItem is an array containing elements of:

RelatedItem[{item}].@odata.id Member of Power.v1_7_1.Power

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Voltages[{item}].SensorNumber Member of Power.v1_7_1.Power

Description A numerical identifier to represent the voltage sensor
Type integer or null
Read Only True
Added iLO6 1.57

Voltages[{item}].Status Member of Power.v1_7_1.Power See the Redfish standard schema and specification for information on common Status object.

Voltages[{item}].UpperThresholdCritical Member of Power.v1_7_1.Power

Description Above normal range but not yet fatal.
Type number or null
Read Only True
Added iLO6 1.57

Voltages[{item}].UpperThresholdFatal Member of Power.v1_7_1.Power

Description Above normal range and is fatal
Type number or null
Read Only True
Added iLO6 1.57

Voltages[{item}].UpperThresholdNonCritical Member of Power.v1_7_1.Power

Description Above normal range
Type number or null
Read Only True
Added iLO6 1.57

Processor

@odata.type: "#Processor.v1_8_2.Processor"

The Processor resource describes the Processor resource. It represents the properties of a processor attached to a System.

Resource Instances

Uri HTTP Allow
/redfish/v1/systems/{item}/processors/{item} GET

EnvironmentMetrics

The link to the environment metrics for this processor. EnvironmentMetrics is a link ("@odata.id": URI) to another resource.

InstructionSet

Member of Processor.v1_8_2.Processor

Description The instruction set of the processor
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
x86 x86 32-bit
x86-64 x86 64-bit
IA-64 Intel IA-64
ARM-A32 ARM 32-bit
ARM-A64 ARM 64-bit
MIPS32 MIPS 32-bit
MIPS64 MIPS 64-bit
OEM OEM-defined

Manufacturer

Member of Processor.v1_8_2.Processor

Description The processor manufacturer
Type string or null
Read Only True
Added iLO6 1.05

MaxSpeedMHz

Member of Processor.v1_8_2.Processor

Description The maximum clock speed of the processor
Type integer or null
Read Only True
Added iLO6 1.05

Metrics

This property shall contain a link to a resource of type ProcessorMetrics that contains the metrics associated with this processor. Metrics is a link ("@odata.id": URI) to another resource.

Model

Member of Processor.v1_8_2.Processor

Description The product model number of this device
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.AssetTag

Member of Processor.v1_8_2.Processor

Description The processor asset tag.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.Cache (array)

Member of Processor.v1_8_2.Processor

Cache is an array containing elements of:

Cache[{item}].Associativity Member of Processor.v1_8_2.Processor

Description The associativity of the cache.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
DirectMapped Direct Mapped
2waySetAssociative 2-way Set-Associative
4waySetAssociative 4-way Set-Associative
FullyAssociative Fully Associative
8waySetAssociative 8-way Set-Associative
16waySetAssociative 16-way Set-Associative
12waySetAssociative 12-way Set-Associative
24waySetAssociative 24-way Set-Associative
32waySetAssociative 32-way Set-Associative
48waySetAssociative 48-way Set-Associative
64waySetAssociative 64-way Set-Associative
20waySetAssociative 20-way Set-Associative
None

Cache[{item}].CacheSpeedns Member of Processor.v1_8_2.Processor

Description The cache speed (ns).
Type integer or null
Read Only True
Added iLO6 1.05

Cache[{item}].CurrentSRAMType (array) Member of Processor.v1_8_2.Processor

CurrentSRAMType is an array containing elements of:

CurrentSRAMType[{item}] Member of Processor.v1_8_2.Processor

Description The array of supported SRAM attributes currently used by the cache.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
NonBurst Non-Burst
Burst Burst
PipelineBurst Pipeline Burst
Synchronous Synchronous
Asynchronous Asynchronous

Cache[{item}].EccType Member of Processor.v1_8_2.Processor

Description The cache memory ECC type.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
None None
Parity Parity
SingleBitECC Single-bit ECC
MultiBitECC Multi-bit ECC

Cache[{item}].InstalledSizeKB Member of Processor.v1_8_2.Processor

Description The installed cache size (KB).
Type integer or null
Read Only True
Added iLO6 1.05

Cache[{item}].Location Member of Processor.v1_8_2.Processor

Description The cache location (internal or external).
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Internal Internal
External External

Cache[{item}].MaximumSizeKB Member of Processor.v1_8_2.Processor

Description The maximum cache size (KB).
Type integer or null
Read Only True
Added iLO6 1.05

Cache[{item}].Policy Member of Processor.v1_8_2.Processor

Description The caching policy.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
WriteThrough Write through
WriteBack Write back
Varies Varies with memory address

Cache[{item}].Socketed Member of Processor.v1_8_2.Processor

Description If true, the cache is a socketed component.
Type boolean or null
Read Only True
Added iLO6 1.05

Cache[{item}].Status Member of Processor.v1_8_2.Processor See the Redfish standard schema and specification for information on common Status object.

Cache[{item}].SupportedSRAMType (array) Member of Processor.v1_8_2.Processor

SupportedSRAMType is an array containing elements of:

SupportedSRAMType[{item}] Member of Processor.v1_8_2.Processor

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
NonBurst Non-Burst
Burst Burst
PipelineBurst Pipeline Burst
Synchronous Synchronous
Asynchronous Asynchronous

Cache[{item}].SystemCacheType Member of Processor.v1_8_2.Processor

Description The cache type (unified, instructions, or data).
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Instruction Instruction
Data Data
Unified Unified

Oem.Hpe.Characteristics (array)

Member of Processor.v1_8_2.Processor

Characteristics is an array containing elements of:

Characteristics[{item}] Member of Processor.v1_8_2.Processor

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
64Bit 64-bit Capable
MultiCore Multi-Core
HwThread Hardware Thread
ExecuteProtection Execute Protection
EnhancedVirtualization Enhanced Virtualization
PowerPerfControl Power/Performance Control

Oem.Hpe.ConfigStatus

Oem.Hpe.ConfigStatus.Populated Member of Processor.v1_8_2.Processor

Description True if the processor socket is populated with a CPU.
Type boolean or null
Read Only True
Added iLO6 1.05

Oem.Hpe.ConfigStatus.State Member of Processor.v1_8_2.Processor

Description The current state of the processor.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Enabled CPU Enabled
DisabledByUser CPU Disabled by User through BIOS Setup
DisabledByBios CPU Disabled By BIOS (POST Error)
Idle CPU is Idle, waiting to be enabled.

Oem.Hpe.CoresEnabled

Member of Processor.v1_8_2.Processor

Description The number of enabled cores in the processor.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.DOTState

Member of Processor.v1_8_2.Processor

Description Provides current ownership state of NVidia CPU ERoT
Type string or null
Read Only True
Added iLO6 1.62

The following are the supported values:

Value Description
Unknown CAK Keys are not yet installed on the module or the CAK Test failed
Unlocked The NVidia CPU ERoT is not locked with LAK Keys
Locked The NVidia CPU ERoT has been locked with CAK & LAK Keys

Oem.Hpe.ExternalClockMHz

Member of Processor.v1_8_2.Processor

Description The processor external clock frequency (MHZ), for example, 1000 = 1 GHZ.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.MicrocodePatches (array)

Member of Processor.v1_8_2.Processor

MicrocodePatches is an array containing elements of:

MicrocodePatches[{item}].CpuId Member of Processor.v1_8_2.Processor

Description The microcode patch CPUID.
Type string
Read Only True
Added iLO6 1.05

MicrocodePatches[{item}].Date Member of Processor.v1_8_2.Processor

Description The microcode patch date.
Type string
Read Only True
Added iLO6 1.05
Format date-time

MicrocodePatches[{item}].PatchId Member of Processor.v1_8_2.Processor

Description The microcode patch ID.
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.NVLinkState

Member of Processor.v1_8_2.Processor

Description The Link between CPU and GPU .
Type string or null
Read Only True
Added iLO6 1.61

The following are the supported values:

Value Description
Inactive The link between CPU and GPU is inactive
Active The link between CPU and GPU is active
Error There is an error while establishing link between CPU and GPU

Oem.Hpe.PartNumber

Member of Processor.v1_8_2.Processor

Description The processor part number.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.RatedSpeedMHz

Member of Processor.v1_8_2.Processor

Description The speed of the processor (in MHz) as of the last system boot, for example, 1000 = 1GHz.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.SerialNumber

Member of Processor.v1_8_2.Processor

Description The processor serial number.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.VoltageVoltsX10

Member of Processor.v1_8_2.Processor

Description The processor voltage multiplied by 10, for example, 3.3v = 33.
Type integer or null
Read Only True
Added iLO6 1.05

PartNumber

Member of Processor.v1_8_2.Processor

Description The processor part number.
Type string or null
Read Only True
Added iLO6 1.05

ProcessorArchitecture

Member of Processor.v1_8_2.Processor

Description The architecture of the processor
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
x86 x86 or x86-64
IA-64 Intel Itanium
ARM ARM
MIPS MIPS
OEM OEM-defined

ProcessorId

ProcessorId.EffectiveFamily Member of Processor.v1_8_2.Processor

Description The effective Family for this processor
Type string or null
Read Only True
Added iLO6 1.05

ProcessorId.EffectiveModel Member of Processor.v1_8_2.Processor

Description The effective Model for this processor
Type string or null
Read Only True
Added iLO6 1.05

ProcessorId.IdentificationRegisters Member of Processor.v1_8_2.Processor

Description The contents of the Identification Registers (CPUID) for this processor
Type string or null
Read Only True
Added iLO6 1.05

ProcessorId.MicrocodeInfo Member of Processor.v1_8_2.Processor

Description The Microcode Information for this processor
Type string or null
Read Only True
Added iLO6 1.05

ProcessorId.Step Member of Processor.v1_8_2.Processor

Description The Step value for this processor
Type string or null
Read Only True
Added iLO6 1.05

ProcessorId.VendorId Member of Processor.v1_8_2.Processor

Description The Vendor Identification for this processor
Type string or null
Read Only True
Added iLO6 1.05

ProcessorType

Member of Processor.v1_8_2.Processor

Description The type of processor
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
CPU A Central Processing Unit
GPU A Graphics Processing Unit
FPGA A Field Programmable Gate Array
DSP A Digital Signal Processor
Accelerator An Accelerator
OEM An OEM-defined Processing Unit

SerialNumber

Member of Processor.v1_8_2.Processor

Description The processor serial number.
Type string or null
Read Only True
Added iLO6 1.05

Socket

Member of Processor.v1_8_2.Processor

Description The socket or location of the processor
Type string or null
Read Only True
Added iLO6 1.05

Status

Member of Processor.v1_8_2.Processor See the Redfish standard schema and specification for information on common Status object.

TotalCores

Member of Processor.v1_8_2.Processor

Description The total number of cores contained in this processor
Type integer or null
Read Only True
Added iLO6 1.05

TotalThreads

Member of Processor.v1_8_2.Processor

Description The total number of execution threads supported by this processor
Type integer or null
Read Only True
Added iLO6 1.05

ProcessorCollection

@odata.type: "#ProcessorCollection.ProcessorCollection"

A Collection of Processor resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/systems/{item}/processors GET

Links to other Resources

Link Name Destination type
Members[] Processor

Members (array)

Member of ProcessorCollection.ProcessorCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of ProcessorCollection.ProcessorCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of ProcessorCollection.ProcessorCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

ProcessorMetrics

@odata.type: "#ProcessorMetrics.v1_6_4.ProcessorMetrics"

The ProcessorMetrics schema contains usage and health statistics for a processor.

Resource Instances

Uri HTTP Allow
/redfish/v1/systems/{item}/processors/{item}/processormetrics GET

BandwidthPercent

Member of ProcessorMetrics.v1_6_4.ProcessorMetrics

Description The bandwidth usage of this processor as a percentage.
Type number or null
Read Only True
Added iLO6 1.61

Oem.Hpe.EDPViolationStateType

Member of ProcessorMetrics.v1_6_4.ProcessorMetrics

Description EDP violation.
Type string or null
Read Only True
Added iLO6 1.61

The following are the supported values:

Value Description
Normal The value is within the range
OutOfRange The value is outside the range

Oem.Hpe.MemorySpareChannelPresence

Member of ProcessorMetrics.v1_6_4.ProcessorMetrics

Description The memory spare channel presence state.
Type boolean or null
Read Only True
Added iLO6 1.61

Oem.Hpe.PCIeConnectionLinksStatus (array)

Member of ProcessorMetrics.v1_6_4.ProcessorMetrics

PCIeConnectionLinksStatus is an array containing elements of:

PCIeConnectionLinksStatus[{item}] Member of ProcessorMetrics.v1_6_4.ProcessorMetrics

Type string or null
Read Only True
Added iLO6 1.61

The following are the supported values:

Value Description
Connected This channel between GPU and CPU is connected
Disconnected This channel between GPU and CPU is not connected

Oem.Hpe.PerformanceState

Member of ProcessorMetrics.v1_6_4.ProcessorMetrics

Description The performance state
Type string or null
Read Only True
Added iLO6 1.61

The following are the supported values:

Value Description
Degraded The entity is operating at a degraded functional level
Normal The entity is operating at a full functional level at full speed
Throttled The entity is operating at a full functional level at reduced speed

Oem.Hpe.PowerBreakPerformanceState

Member of ProcessorMetrics.v1_6_4.ProcessorMetrics

Description The power break performance state
Type string or null
Read Only True
Added iLO6 1.61

The following are the supported values:

Value Description
Degraded The entity is operating at a degraded functional level
Normal The value is within the range
Throttled The value is outside the range

Pump

@odata.type: "#Pump.v1_1_0.Pump"

The Pump schema describes a pump unit for a cooling system or similar device.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/thermalsubsystem/pumps/{item} GET

Links to other Resources

Link Name Destination type
Assembly Assembly

Assembly

The link to the summary of assembly for this subsystem. Assembly is a link ("@odata.id": URI) to another resource.

PhysicalContext

Member of Pump.v1_1_0.Pump

Description The area or device associated with this pump.
Type string or null
Read Only True
Added iLO6 1.63

The following are the supported values:

Value Description
Null A value is temporarily unavailable
Room The room
Intake The intake point of the chassis
Exhaust The exhaust point of the chassis
Front The front of the chassis
Back The back of the chassis
Upper The upper portion of the chassis
Lower The lower portion of the chassis
CPU A Processor (CPU)
GPU A Graphics Processor (GPU)
Backplane A backplane within the chassis
SystemBoard The system board (PCB)
PowerSupply A power supply
VoltageRegulator A voltage regulator device
StorageDevice A storage device
NetworkingDevice A networking device
ComputeBay Within a compute bay
StorageBay Within a storage bay
NetworkBay Within a networking bay
ExpansionBay Within an expansion bay
PowerSupplyBay Within a power supply bay

PumpSpeedPercent

PumpSpeedPercent.DataSourceUri Member of Pump.v1_1_0.Pump

Description The link to the resource that provides the data for this sensor.
Type string or null
Read Only True
Added iLO6 1.63

PumpSpeedPercent.Reading Member of Pump.v1_1_0.Pump

Description The sensor value.
Type number or null
Read Only True
Added iLO6 1.63

PumpSpeedPercent.SpeedRPM Member of Pump.v1_1_0.Pump

Description The rotational speed.
Type number or null
Read Only True
Added iLO6 1.63

Status

Member of Pump.v1_1_0.Pump See the Redfish standard schema and specification for information on common Status object.

PumpCollection

@odata.type: "#PumpCollection.PumpCollection"

The collection of Pump resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/thermalsubsystem/pumps GET

Links to other Resources

Link Name Destination type
Members[] Pump

Members (array)

Member of PumpCollection.PumpCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of PumpCollection.PumpCollection

Type string
Read Only True
Added iLO6 1.63
Format uri-reference

Members@odata.count

Member of PumpCollection.PumpCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.63

Role

@odata.type: "#Role.v1_2_1.Role"

This resource defines a user role to be used in conjunction with a Manager Account.

Resource Instances

Uri HTTP Allow
/redfish/v1/accountservice/roles/{item} GET PATCH

AssignedPrivileges (array)

Member of Role.v1_2_1.Role

AssignedPrivileges is an array containing elements of:

AssignedPrivileges[{item}] Member of Role.v1_2_1.Role

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Login Able to log into the service and read resources.
ConfigureManager Able to configure Manager resources.
ConfigureUsers Able to configure Users and their Accounts.
ConfigureSelf Able to change the password for the current user Account.
ConfigureComponents Able to configure components managed by this service.

IsPredefined

Member of Role.v1_2_1.Role

Description This property is used to indicate if the Role is one of the Redfish Predefined Roles vs a Custom role.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.GroupDn

Member of Role.v1_2_1.Role

Description The complete or shortened distinguished name of the directory group.
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.GroupSid

Member of Role.v1_2_1.Role

Description The security identifier of the directory group (for kerberos authentication and Active Directory integration only).
Type string or null
Read Only True
Added iLO6 1.05

OemPrivileges (array)

Member of Role.v1_2_1.Role

OemPrivileges is an array containing elements of:

OemPrivileges[{item}] Member of Role.v1_2_1.Role

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
RemoteConsolePriv Able to remotely access the host system Remote Console, including video, keyboard, and mouse control.
VirtualMediaPriv Able to use the Virtual Media feature on the host system.
VirtualPowerAndResetPriv Able to power-cycle or reset the host system. These activities interrupt system availability. A user with this privilege can diagnose the system by using the Generate NMI to System button.
HostBIOSConfigPriv Able to configure Host BIOS Settings.
HostNICConfigPriv Able to configure Host NIC Settings.
HostStorageConfigPriv Able to configure Host Storage Settings.
SystemRecoveryConfigPriv Able to manage the critical recovery firmware images on the Manager's Repository.

RoleId

Member of Role.v1_2_1.Role

Description This property contains the name of the Role.
Type string
Read Only True
Added iLO6 1.05

RoleCollection

@odata.type: "#RoleCollection.RoleCollection"

A Collection of Role resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/accountservice/roles GET

Links to other Resources

Link Name Destination type
Members[] Role

Members (array)

Member of RoleCollection.RoleCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of RoleCollection.RoleCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of RoleCollection.RoleCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

SecureBoot

@odata.type: "#SecureBoot.v1_1_0.SecureBoot"

This resource contains UEFI Secure Boot information. It represents properties for managing the UEFI Secure Boot functionality of a system.

Resource Instances

Uri HTTP Allow
/redfish/v1/systems/{item}/secureboot GET PATCH

Links to other Resources

Link Name Destination type
securebootdatabases Collection of SecureBootDatabase

SecureBootCurrentBoot

Member of SecureBoot.v1_1_0.SecureBoot

Description Secure Boot state during the current boot cycle.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Enabled Secure Boot is currently enabled.
Disabled Secure Boot is currently disabled.

SecureBootDatabases

A link to the collection of UEFI Secure Boot databases. SecureBootDatabases is a link ("@odata.id": URI) to another resource.

SecureBootEnable

Member of SecureBoot.v1_1_0.SecureBoot

Description Enable or disable UEFI Secure Boot (takes effect on next boot).
Type boolean or null
Read Only False
Added iLO6 1.05

SecureBootMode

Member of SecureBoot.v1_1_0.SecureBoot

Description Current Secure Boot Mode.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
SetupMode Secure Boot is currently in Setup Mode.
UserMode Secure Boot is currently in User Mode.
AuditMode Secure Boot is currently in Audit Mode.
DeployedMode Secure Boot is currently in Deployed Mode.

Actions

SecureBoot.ResetKeys Member of SecureBoot.v1_1_0.SecureBoot Action to perform reset of the Secure Boot Keys.

Parameters:

ResetKeysType (string)

This parameter specifies what type of reset action to perform.

Value Description
ResetAllKeysToDefault Reset to default Secure Boot keys on next boot.
DeletePK Delete Secure Boot platform keys on next boot.
DeleteAllKeys Delete all Secure Boot keys on next boot.

SecureBootDatabase

@odata.type: "#SecureBootDatabase.v1_0_0.SecureBootDatabase"

The SecureBootDatabase schema describes a UEFI Secure Boot database used to store certificates or hashes.

Resource Instances

Uri HTTP Allow
/redfish/v1/Systems/{item}/SecureBoot/SecureBootDatabases/PK GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/db GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbdefault GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbr GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbrdefault GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbt GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbtdefault GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbx GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbxdefault GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kek GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/kekdefault GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/pkdefault GET

Links to other Resources

Link Name Destination type
Certificates Collection of Certificate
Signatures Collection of Signature

Certificates

A link to the collection of certificates contained in this UEFI Secure Boot database. Certificates is a link ("@odata.id": URI) to another resource.

DatabaseId

Member of SecureBootDatabase.v1_0_0.SecureBootDatabase

Description This property contains the name of the UEFI Secure Boot database.
Type string
Read Only True
Added iLO6 1.10

Signatures

A link to the collection of signatures contained in this UEFI Secure Boot database. Signatures is a link ("@odata.id": URI) to another resource.

Actions

SecureBootDatabase.ResetKeys Member of SecureBootDatabase.v1_0_0.SecureBootDatabase Action to perform reset of the Secure Boot Database Keys.

Parameters:

ResetKeysType (string)

This parameter specifies what type of reset action to perform.

Value Description
ResetAllKeysToDefault Reset to default Secure Boot Database keys on next boot.
DeleteAllKeys Delete all Secure Boot Database keys on next boot.

SecureBootDatabaseCollection

@odata.type: "#SecureBootDatabaseCollection.SecureBootDatabaseCollection"

The collection of SecureBootDatabase resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/systems/{item}/secureboot/securebootdatabases GET

Links to other Resources

Link Name Destination type
Members[] SecureBootDatabase

Members (array)

Member of SecureBootDatabaseCollection.SecureBootDatabaseCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of SecureBootDatabaseCollection.SecureBootDatabaseCollection

Type string
Read Only True
Added iLO6 1.10
Format uri-reference

Members@odata.count

Member of SecureBootDatabaseCollection.SecureBootDatabaseCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.10

Sensor

@odata.type: "#Sensor.v1_10_0.Sensor"

The Sensor schema describes a sensor and its properties.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/sensors/{item} GET PATCH

Oem.Hpe.LocationXmm

Member of Sensor.v1_10_0.Sensor

Description The location of the sensor, in millimeters, along the X axis from the logical reference point.
Type integer
Read Only True
Added iLO6 1.63

Oem.Hpe.LocationYmm

Member of Sensor.v1_10_0.Sensor

Description The location of the sensor, in millimeters, along the Y axis from the logical reference point.
Type integer
Read Only True
Added iLO6 1.63

PhysicalContext

Member of Sensor.v1_10_0.Sensor

Description The area or device to which this sensor measurement applies.
Type string or null
Read Only True
Added iLO6 1.63

The following are the supported values:

Value Description
Null A value is temporarily unavailable
Room The room
Intake The intake point of the chassis
Exhaust The exhaust point of the chassis
Front The front of the chassis
Back The back of the chassis
Upper The upper portion of the chassis
Lower The lower portion of the chassis
CPU A Processor (CPU)
GPU A Graphics Processor (GPU)
Backplane A backplane within the chassis
SystemBoard The system board (PCB)
PowerSupply A power supply
VoltageRegulator A voltage regulator device
StorageDevice A storage device
NetworkingDevice A networking device
ComputeBay Within a compute bay
StorageBay Within a storage bay
NetworkBay Within a networking bay
ExpansionBay Within an expansion bay
PowerSupplyBay Within a power supply bay

Reading

Member of Sensor.v1_10_0.Sensor

Description The sensor value.
Type number or null
Read Only True
Added iLO6 1.61

Status

Member of Sensor.v1_10_0.Sensor See the Redfish standard schema and specification for information on common Status object.

Thresholds

Thresholds.LowerCaution Thresholds.LowerCaution.Activation Member of Sensor.v1_10_0.Sensor

Description The direction of crossing that activates this threshold.
Type string
Read Only True
Added iLO6 1.63

The following are the supported values:

Value Description
Increasing Value increases above the threshold.
Decreasing Value decreases below the threshold.
Either Value crosses the threshold in either direction.

Thresholds.LowerCaution.DwellTime Member of Sensor.v1_10_0.Sensor

Description The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated.
Type string or null
Read Only False
Added iLO6 1.63

Thresholds.LowerCaution.Reading Member of Sensor.v1_10_0.Sensor

Description The threshold value.
Type integer or null
Read Only False
Added iLO6 1.63

Thresholds.LowerCritical Thresholds.LowerCritical.Activation Member of Sensor.v1_10_0.Sensor

Description The direction of crossing that activates this threshold.
Type string
Read Only True
Added iLO6 1.63

The following are the supported values:

Value Description
Increasing Value increases above the threshold.
Decreasing Value decreases below the threshold.
Either Value crosses the threshold in either direction.

Thresholds.LowerCritical.DwellTime Member of Sensor.v1_10_0.Sensor

Description The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated.
Type string or null
Read Only False
Added iLO6 1.63

Thresholds.LowerCritical.Reading Member of Sensor.v1_10_0.Sensor

Description The threshold value.
Type integer or null
Read Only False
Added iLO6 1.63

Thresholds.UpperCaution Thresholds.UpperCaution.Activation Member of Sensor.v1_10_0.Sensor

Description The direction of crossing that activates this threshold.
Type string
Read Only True
Added iLO6 1.63

The following are the supported values:

Value Description
Increasing Value increases above the threshold.
Decreasing Value decreases below the threshold.
Either Value crosses the threshold in either direction.

Thresholds.UpperCaution.DwellTime Member of Sensor.v1_10_0.Sensor

Description The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated.
Type string or null
Read Only False
Added iLO6 1.63

Thresholds.UpperCaution.Reading Member of Sensor.v1_10_0.Sensor

Description The threshold value.
Type integer or null
Read Only False
Added iLO6 1.63

Thresholds.UpperCautionUser Thresholds.UpperCautionUser.Reading Member of Sensor.v1_10_0.Sensor

Description The threshold value.
Type integer or null
Read Only False
Added iLO6 1.63

Thresholds.UpperCritical Thresholds.UpperCritical.Activation Member of Sensor.v1_10_0.Sensor

Description The direction of crossing that activates this threshold.
Type string
Read Only True
Added iLO6 1.63

The following are the supported values:

Value Description
Increasing Value increases above the threshold.
Decreasing Value decreases below the threshold.
Either Value crosses the threshold in either direction.

Thresholds.UpperCritical.DwellTime Member of Sensor.v1_10_0.Sensor

Description The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated.
Type string or null
Read Only False
Added iLO6 1.63

Thresholds.UpperCritical.Reading Member of Sensor.v1_10_0.Sensor

Description The threshold value.
Type integer or null
Read Only False
Added iLO6 1.63

Thresholds.UpperCriticalUser Thresholds.UpperCriticalUser.Reading Member of Sensor.v1_10_0.Sensor

Description The threshold value.
Type integer or null
Read Only False
Added iLO6 1.63

Thresholds.UpperFatal Thresholds.UpperFatal.Activation Member of Sensor.v1_10_0.Sensor

Description The direction of crossing that activates this threshold.
Type string
Read Only True
Added iLO6 1.63

The following are the supported values:

Value Description
Increasing Value increases above the threshold.
Decreasing Value decreases below the threshold.
Either Value crosses the threshold in either direction.

Thresholds.UpperFatal.DwellTime Member of Sensor.v1_10_0.Sensor

Description The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated.
Type string or null
Read Only False
Added iLO6 1.63

Thresholds.UpperFatal.Reading Member of Sensor.v1_10_0.Sensor

Description The threshold value.
Type integer or null
Read Only False
Added iLO6 1.63

SensorCollection

@odata.type: "#SensorCollection.SensorCollection"

The collection of Sensor resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/sensors GET

Links to other Resources

Link Name Destination type
Members[] Sensor

Members (array)

Member of SensorCollection.SensorCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of SensorCollection.SensorCollection

Type string
Read Only True
Added iLO6 1.61
Format uri-reference

Members@odata.count

Member of SensorCollection.SensorCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.61

SerialInterface

@odata.type: "#SerialInterface.v1_1_7.SerialInterface"

This is the schema definition for the Serial Interface.

Resource Instances

Uri HTTP Allow
/redfish/v1/managers/{item}/serialinterfaces/{item} GET PATCH

BitRate

Member of SerialInterface.v1_1_7.SerialInterface

Description The receive and transmit rate of data flow, typically in bits per second (bit/s), over the serial connection.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
9600 A bit rate of 9600 bit/s.
19200 A bit rate of 19200 bit/s.
38400 A bit rate of 38400 bit/s.
57600 A bit rate of 57600 bit/s.
115200 A bit rate of 115200 bit/s.

InterfaceEnabled

Member of SerialInterface.v1_1_7.SerialInterface

Description An indication of whether this interface is enabled.
Type boolean or null
Read Only False
Added iLO6 1.05

SerialInterfaceCollection

@odata.type: "#SerialInterfaceCollection.SerialInterfaceCollection"

A Collection of SerialInterface resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/managers/{item}/serialinterfaces GET

Links to other Resources

Link Name Destination type
Members[] SerialInterface

Members (array)

Member of SerialInterfaceCollection.SerialInterfaceCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of SerialInterfaceCollection.SerialInterfaceCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of SerialInterfaceCollection.SerialInterfaceCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

Session

@odata.type: "#Session.v1_0_0.Session"

The Session resource describes a single connection (session) between a client and a Redfish service instance.

Resource Instances

Uri HTTP Allow
/redfish/v1/sessionservice/sessions/{item} GET DELETE

Oem.Hpe.AccessTime

Member of Session.v1_0_0.Session

Description User session last-access time
Type string
Read Only True
Added iLO6 1.05
Format date-time

Oem.Hpe.LoginTime

Member of Session.v1_0_0.Session

Description User session login time
Type string
Read Only True
Added iLO6 1.05
Format date-time

Oem.Hpe.MySession

Member of Session.v1_0_0.Session

Description Indicates whether this is a session I own.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.Privileges

Oem.Hpe.Privileges.HostBIOSConfigPriv Member of Session.v1_0_0.Session

Description This privilege enables a user to configure Host Bios Settings.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.Privileges.HostNICConfigPriv Member of Session.v1_0_0.Session

Description This privilege enables a user to configure Host NIC Settings.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.Privileges.HostStorageConfigPriv Member of Session.v1_0_0.Session

Description This privilege enables a user to configure Host Storage Settings.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.Privileges.LoginPriv Member of Session.v1_0_0.Session

Description This privilege enables a user to log in to the management processor. All local accounts have the login privilege. This privilege is added automatically if it is not specified.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.Privileges.RemoteConsolePriv Member of Session.v1_0_0.Session

Description This privilege enables a user to remotely access the host system Remote Console, including video, keyboard, and mouse control.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.Privileges.SystemRecoveryConfigPriv Member of Session.v1_0_0.Session

Description This privilege enables a user to manage the critical recovery firmware images on the iLO Repository.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.Privileges.UserConfigPriv Member of Session.v1_0_0.Session

Description This privilege enables a user to add, edit, and delete local management processor user accounts. A user with this privilege can change privileges for all users.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.Privileges.VirtualMediaPriv Member of Session.v1_0_0.Session

Description This privilege enables a user to use the Virtual Media feature on the host system.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.Privileges.VirtualPowerAndResetPriv Member of Session.v1_0_0.Session

Description This privilege enables a user to power-cycle or reset the host system. These activities interrupt system availability. A user with this privilege can diagnose the system by using the Generate NMI to System button.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.Privileges.iLOConfigPriv Member of Session.v1_0_0.Session

Description This privilege enables a user to configure most management processor settings, including security settings, and to remotely update the management processor firmware. This privilege does not enable local user account administration.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.UserAccount

Member of Session.v1_0_0.Session

Description Login details of the user
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.UserDistinguishedName

Member of Session.v1_0_0.Session

Description LDAP user is identified by its distinguished name (DN).
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.UserExpires

Member of Session.v1_0_0.Session

Description User session expire time
Type string
Read Only True
Added iLO6 1.05
Format date-time

Oem.Hpe.UserIP

Member of Session.v1_0_0.Session

Description IP address of the user
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.UserTag

Member of Session.v1_0_0.Session

Description Session source
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
Web UI
RBSU
Remote Console
SSH
IPMI/RMCP
SM-CLP
RIBCL
RESTHost
RIBCLHost
WSMgmt
Telnet
Federation
USBFrontPort
REST
Unknown

Oem.Hpe.UserType

Member of Session.v1_0_0.Session

Description User type
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
Local
Directory
Single Sign On
Kerberos
Trusted Key
Security Override
System
Federation

UserName

Member of Session.v1_0_0.Session

Description Name to use to log in to the management processor.
Type string
Read Only True
Added iLO6 1.05

SessionCollection

@odata.type: "#SessionCollection.SessionCollection"

A Collection of Session resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/sessionservice/sessions GET POST

Links to other Resources

Link Name Destination type
Oem/Hpe/Links/MySession Session
Members[] Session

Members (array)

Member of SessionCollection.SessionCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of SessionCollection.SessionCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of SessionCollection.SessionCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

SessionService

@odata.type: "#SessionService.v1_0_0.SessionService"

The SessionService resource describes the BMC Redfish Session Service. It represents the properties for the service itself and has links to the actual list of sessions.

Resource Instances

Uri HTTP Allow
/redfish/v1/sessionservice GET PATCH

Links to other Resources

Link Name Destination type
Sessions Collection of Session

ServiceEnabled

Member of SessionService.v1_0_0.SessionService

Description This indicates whether this service is enabled.
Type boolean or null
Read Only True
Added iLO6 1.05

SessionTimeout

Member of SessionService.v1_0_0.SessionService

Description This is the number of seconds of inactivity that a session may have before the session service closes the session due to inactivity. Here the value 0 means no timeout or infinite timeout.
Type integer
Read Only False
Added iLO6 1.05

Sessions

This property references a Collection resource of Sessions. Sessions is a link ("@odata.id": URI) to another resource.

Status

Member of SessionService.v1_0_0.SessionService See the Redfish standard schema and specification for information on common Status object.

Signature

@odata.type: "#Signature.v1_0_2.Signature"

The Signature schema describes a signature or a hash.

Resource Instances

Uri HTTP Allow
/redfish/v1/systems/{item}/secureboot/securebootdatabases/db/signatures/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbdefault/signatures/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbr/signatures/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbrdefault/signatures/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbt/signatures/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbtdefault/signatures/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbx/signatures/{item} GET DELETE
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbxdefault/signatures/{item} GET DELETE

SignatureString

Member of Signature.v1_0_2.Signature

Description The string for the signature.
Type string
Read Only False
Added iLO6 1.10

SignatureType

Member of Signature.v1_0_2.Signature

Description The format of the signature.
Type string
Read Only False
Added iLO6 1.10

SignatureTypeRegistry

Member of Signature.v1_0_2.Signature

Type string
Read Only False
Added iLO6 1.10

The following are the supported values:

Value Description
UEFI A signature defined in the UEFI Specification.

UefiSignatureOwner

Member of Signature.v1_0_2.Signature

Description The UEFI signature owner for this signature.
Type string or null
Read Only True
Added iLO6 1.10

SignatureCollection

@odata.type: "#SignatureCollection.SignatureCollection"

The collection of Signature resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/systems/{item}/secureBoot/securebootdatabases/dbdefault/signatures GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/db/signatures GET POST
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbr/signatures GET POST
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbrdefault/signatures GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbt/signatures GET POST
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbtdefault/signatures GET
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbx/signatures GET POST
/redfish/v1/systems/{item}/secureboot/securebootdatabases/dbxdefault/signatures GET

Links to other Resources

Link Name Destination type
Members[] Signature

Members (array)

Member of SignatureCollection.SignatureCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of SignatureCollection.SignatureCollection

Type string
Read Only True
Added iLO6 1.10
Format uri-reference

Members@odata.count

Member of SignatureCollection.SignatureCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.10

SoftwareInventory

@odata.type: "#SoftwareInventory.v1_2_0.SoftwareInventory"

The SoftwareInventory resource describes the inventory of software or firmware components.

Resource Instances

Uri HTTP Allow
/redfish/v1/updateservice/firmwareinventory/{item} GET
/redfish/v1/updateservice/softwareinventory/{item} GET

LowestSupportedVersion

Member of SoftwareInventory.v1_2_0.SoftwareInventory

Description The lowest supported version of this software.
Type string or null
Read Only True
Added iLO6 1.61

Manufacturer

Member of SoftwareInventory.v1_2_0.SoftwareInventory

Description The manufacturer or producer of this software.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.DeviceClass

Member of SoftwareInventory.v1_2_0.SoftwareInventory

Description DeviceType GUID rendered by iLO for certain items iLO knows how to flash, and omitted for all other items.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.DeviceContext

Member of SoftwareInventory.v1_2_0.SoftwareInventory

Description Friendly text string - same as 'Location' in fw inventory - omitted if not available.
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.DeviceInstance

Member of SoftwareInventory.v1_2_0.SoftwareInventory

Description UEFI Device Path if a PCI Device - omitted otherwise.
Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.Targets (array)

Member of SoftwareInventory.v1_2_0.SoftwareInventory

Targets is an array containing elements of:

Targets[{item}] Member of SoftwareInventory.v1_2_0.SoftwareInventory

Description A GUID indicating iLO's knowledge of a possible correlation GUIDs vs. components.
Type string or null
Read Only True
Added iLO6 1.05

Oem.Hpe.Version

Member of SoftwareInventory.v1_2_0.SoftwareInventory

Description NVIDIA CEC Firmware version
Type string or null
Read Only True
Added iLO6 1.30

RelatedItem (array)

Member of SoftwareInventory.v1_2_0.SoftwareInventory

RelatedItem is an array containing elements of:

RelatedItem[{item}].@odata.id Member of SoftwareInventory.v1_2_0.SoftwareInventory

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

RelatedItem@odata.count

Member of SoftwareInventory.v1_2_0.SoftwareInventory

Description The number of items in a collection.
Type integer
Read Only True
Added iLO6 1.05

SoftwareId

Member of SoftwareInventory.v1_2_0.SoftwareInventory

Description The implementation-specific label that identifies this software.
Type string
Read Only True
Added iLO6 1.05

Status

Member of SoftwareInventory.v1_2_0.SoftwareInventory See the Redfish standard schema and specification for information on common Status object.

Updateable

Member of SoftwareInventory.v1_2_0.SoftwareInventory

Description This is true if the item is updatable.
Type boolean or null
Read Only True
Added iLO6 1.05

Version

Member of SoftwareInventory.v1_2_0.SoftwareInventory

Description same as 'VersionString' in existing FwSwVersionInventory
Type string or null
Read Only True
Added iLO6 1.05

SoftwareInventoryCollection

@odata.type: "#SoftwareInventoryCollection.SoftwareInventoryCollection"

A Collection of SoftwareInventory resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/updateservice/firmwareinventory GET
/redfish/v1/updateservice/softwareinventory GET

Links to other Resources

Link Name Destination type
Members[] SoftwareInventory

Members (array)

Member of SoftwareInventoryCollection.SoftwareInventoryCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of SoftwareInventoryCollection.SoftwareInventoryCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of SoftwareInventoryCollection.SoftwareInventoryCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

Switch

@odata.type: "#Switch.v1_9_1.Switch"

The Switch schema contains properties that describe a fabric switch.

Resource Instances

Uri HTTP Allow
/redfish/v1/fabrics/{item}/switches/{item} GET POST

Links to other Resources

Link Name Destination type
Members[] PortCollection

DomainID

Member of Switch.v1_9_1.Switch

Description The domain ID for this switch.
Type integer or null
Read Only True
Added iLO6 1.54

FirmwareVersion

Member of Switch.v1_9_1.Switch

Description The firmware version of this switch.
Type string or null
Read Only True
Added iLO6 1.54

Manufacturer

Member of Switch.v1_9_1.Switch

Description The manufacturer of this switch.
Type string or null
Read Only True
Added iLO6 1.55

Model

Member of Switch.v1_9_1.Switch

Description The product manufacturer-provided model number of this switch.
Type string or null
Read Only True
Added iLO6 1.54

Ports

The link to the collection ports for this switch. Ports is a link ("@odata.id": URI) to another resource.

SerialNumber

Member of Switch.v1_9_1.Switch

Description The serial number for this switch.
Type string or null
Read Only True
Added iLO6 1.55

SupportedProtocols (array)

Member of Switch.v1_9_1.Switch

SupportedProtocols is an array containing elements of:

SupportedProtocols[{item}] Member of Switch.v1_9_1.Switch

Type string or null
Read Only True
Added iLO6 1.54

The following are the supported values:

Value Description
PCIe PCI Express.
AHCI Advanced Host Controller Interface (AHCI).
UHCI Universal Host Controller Interface (UHCI).
SAS Serial Attached SCSI.
SATA Serial AT Attachment.
USB Universal Serial Bus (USB).
NVMe Non-Volatile Memory Express (NVMe).
FC Fibre Channel.
iSCSI Internet SCSI.
FCoE Fibre Channel over Ethernet (FCoE).
FCP Fibre Channel Protocol for SCSI.
FICON FIbre CONnection (FICON).
NVMeOverFabrics NVMe over Fabrics.
SMB Server Message Block (SMB). Also known as the Common Internet File System (CIFS).
NFSv3 Network File System (NFS) version 3.
NFSv4 Network File System (NFS) version 4.
HTTP Hypertext Transport Protocol (HTTP).
HTTPS Hypertext Transfer Protocol Secure (HTTPS).
FTP File Transfer Protocol (FTP).
SFTP SSH File Transfer Protocol (SFTP).
iWARP Internet Wide Area RDMA Protocol (iWARP).
RoCE RDMA over Converged Ethernet Protocol.
RoCEv2 RDMA over Converged Ethernet Protocol Version 2.
I2C Inter-Integrated Circuit Bus.
TCP Transmission Control Protocol (TCP).
UDP User Datagram Protocol (UDP).
TFTP Trivial File Transfer Protocol (TFTP).
GenZ GenZ.
MultiProtocol Multiple Protocols.
InfiniBand InfiniBand.
Ethernet Ethernet.
NVLink NVLink.
OEM OEM-specific.
DisplayPort DisplayPort.
HDMI HDMI.
VGA VGA.
DVI DVI.
CXL Compute Express Link.

SwitchType

Member of Switch.v1_9_1.Switch

Description The protocol being sent over this switch.
Type string or null
Read Only True
Added iLO6 1.55

SwitchCollection

@odata.type: "#SwitchCollection.SwitchCollection"

A Collection of Switch Resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/fabrics/{item}/switches GET DELETE

Links to other Resources

Link Name Destination type
Members[] Collection of SwitchCollection

Members (array)

Member of SwitchCollection.SwitchCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of SwitchCollection.SwitchCollection

Type string
Read Only True
Added iLO6 1.54
Format uri-reference

Members@odata.count

Member of SwitchCollection.SwitchCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.54

Task

@odata.type: "#Task.v1_3_0.Task"

The Task resource describes a specific Task scheduled by or being executed by a Redfish service's Task Service.

Resource Instances

Uri HTTP Allow
/redfish/v1/taskservice/tasks/{item} GET

EndTime

Member of Task.v1_3_0.Task

Description The date-time stamp that the task was last completed.
Type string
Read Only True
Added iLO6 1.05
Format date-time

Messages (array)

Member of Task.v1_3_0.Task

Messages is an array containing elements of:

Messages[{item}].Message Member of Task.v1_3_0.Task

Description This is the human readable message, if provided.
Type string or null
Read Only True
Added iLO6 1.05

Messages[{item}].MessageArgs (array) Member of Task.v1_3_0.Task

MessageArgs is an array containing elements of:

MessageArgs[{item}] Member of Task.v1_3_0.Task

Type string
Read Only True
Added iLO6 1.05

Messages[{item}].MessageId Member of Task.v1_3_0.Task

Description This is the key for this message which can be used to look up the message in a message registry.
Type string
Read Only True
Added iLO6 1.05

Messages[{item}].RelatedProperties (array) Member of Task.v1_3_0.Task

RelatedProperties is an array containing elements of:

RelatedProperties[{item}] Member of Task.v1_3_0.Task

Type string
Read Only True
Added iLO6 1.05

Messages[{item}].Resolution Member of Task.v1_3_0.Task

Description Used to provide suggestions on how to resolve the situation that caused the error.
Type string or null
Read Only True
Added iLO6 1.05

Messages[{item}].Severity Member of Task.v1_3_0.Task

Description This is the severity of the event.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
OK Normal
Warning A condition exists that requires attention
Critical A critical condition exists that requires immediate attention

Payload

Payload.HttpHeaders (array) Member of Task.v1_3_0.Task

HttpHeaders is an array containing elements of:

HttpHeaders[{item}] Member of Task.v1_3_0.Task

Type string
Read Only True
Added iLO6 1.05

Payload.HttpOperation Member of Task.v1_3_0.Task

Description The HTTP operation to perform to execute this Task.
Type string
Read Only True
Added iLO6 1.05

Payload.JsonBody Member of Task.v1_3_0.Task

Description This property contains the JSON payload to use in the execution of this Task.
Type string
Read Only True
Added iLO6 1.05

Payload.TargetUri Member of Task.v1_3_0.Task

Description The URI of the target for this task.
Type string
Read Only True
Added iLO6 1.05
Format uri-reference

StartTime

Member of Task.v1_3_0.Task

Description The date-time stamp that the task was last started.
Type string
Read Only True
Added iLO6 1.05
Format date-time

TaskMonitor

Member of Task.v1_3_0.Task

Description The URI of the Task Monitor for this task.
Type string or null
Read Only True
Added iLO6 1.05
Format uri-reference

TaskState

Member of Task.v1_3_0.Task

Description The state of the task.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
New A new task.
Starting Task is starting.
Running Task is running normally.
Suspended Task has been suspended.
Interrupted Task has been interrupted.
Pending Task is pending and has not started.
Stopping Task is in the process of stopping.
Completed Task has completed.
Killed Task was terminated.
Exception Task has stopped due to an exception condition.
Service Task is running as a service.

TaskStatus

Member of Task.v1_3_0.Task

Description This is the completion status of the task.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
OK Normal.
Warning A condition exists that requires attention.
Critical A critical condition exists that requires immediate attention.

TaskCollection

@odata.type: "#TaskCollection.TaskCollection"

A Collection of Task resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/taskservice/tasks GET

Links to other Resources

Link Name Destination type
Members[] Task

Members (array)

Member of TaskCollection.TaskCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of TaskCollection.TaskCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of TaskCollection.TaskCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

TaskService

@odata.type: "#TaskService.v1_1_1.TaskService"

The TaskService resource describes the Task service. It represents the properties for the service itself and has links to the actual list of tasks.

Resource Instances

Uri HTTP Allow
/redfish/v1/taskservice GET

Links to other Resources

Link Name Destination type
Tasks Collection of Task

CompletedTaskOverWritePolicy

Member of TaskService.v1_1_1.TaskService

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Manual Completed tasks are not automatically overwritten.
Oldest Oldest completed tasks are overwritten.

DateTime

Member of TaskService.v1_1_1.TaskService

Description The current DateTime (with offset) setting that the task service is using.
Type string or null
Read Only True
Added iLO6 1.05
Format date-time

LifeCycleEventOnTaskStateChange

Member of TaskService.v1_1_1.TaskService

Description Send an Event upon Task State Change.
Type boolean
Read Only True
Added iLO6 1.05

ServiceEnabled

Member of TaskService.v1_1_1.TaskService

Description This indicates whether this service is enabled.
Type boolean or null
Read Only True
Added iLO6 1.05

Status

Member of TaskService.v1_1_1.TaskService See the Redfish standard schema and specification for information on common Status object.

Tasks

This property references a resource of type Collection with a MemberType of TaskCollection. Tasks is a link ("@odata.id": URI) to another resource.

TelemetryService

@odata.type: "#TelemetryService.v1_0_0.TelemetryService"

The TelemetryService resource describes the Metrics Service.

Telemetry not supported on AMD platforms

Telemetry Service is supported only on Intel platform. On AMD systems, performing GET on /redfish/v1/TelemetryService will return 400 Error Operation not supported.

Resource Instances

Uri HTTP Allow
/redfish/v1/telemetryservice GET

Links to other Resources

Link Name Destination type
MetricReports Collection of MetricReport
MetricReportDefinitions Collection of MetricDefinition
Triggers Collection of Triggers

MaxReports

Member of TelemetryService.v1_0_0.TelemetryService

Description The maximum number of metric reports supported by this service.
Type integer or null
Read Only True
Added iLO6 1.05

MetricDefinitions

A link to the collection of Metric Definitions. MetricDefinitions is a link ("@odata.id": URI) to another resource.

MetricReportDefinitions

A link to the collection of Metric Reports. MetricReportDefinitions is a link ("@odata.id": URI) to another resource.

MetricReports

A link to the collection of Metric Reports. MetricReports is a link ("@odata.id": URI) to another resource.

MinCollectionInterval

Member of TelemetryService.v1_0_0.TelemetryService

Description The minimum time interval between collections supported by this service.
Type string or null
Read Only True
Added iLO6 1.05

Status

Member of TelemetryService.v1_0_0.TelemetryService See the Redfish standard schema and specification for information on common Status object.

SupportedCollectionFunctions (array)

Member of TelemetryService.v1_0_0.TelemetryService

SupportedCollectionFunctions is an array containing elements of:

SupportedCollectionFunctions[{item}] Member of TelemetryService.v1_0_0.TelemetryService

Description An operation to perform over the sample.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Average An averaging function.
Maximum A maximum function.
Minimum A minimum function.
Summation A summation function.

Triggers

A link to the collection of Triggers, which apply to metrics. Triggers is a link ("@odata.id": URI) to another resource.

Thermal

@odata.type: "#Thermal.v1_7_1.Thermal"

The Thermal resource describes the system thermal metrics. It represents the properties for temperature and cooling.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/thermal GET PATCH

Fans (array)

Member of Thermal.v1_7_1.Thermal

Fans is an array containing elements of:

Fans[{item}].@odata.id Member of Thermal.v1_7_1.Thermal

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Fans[{item}].CorrelatableID Member of Thermal.v1_7_1.Thermal

Description The CorrelatableID for this fan.
Type string or null
Read Only True
Added iLO6 1.05

Fans[{item}].LowerThresholdCritical Member of Thermal.v1_7_1.Thermal

Description Below normal range but not yet fatal.
Type integer or null
Read Only True
Added iLO6 1.05

Fans[{item}].LowerThresholdFatal Member of Thermal.v1_7_1.Thermal

Description Below normal range and is fatal.
Type integer or null
Read Only True
Added iLO6 1.05

Fans[{item}].LowerThresholdNonCritical Member of Thermal.v1_7_1.Thermal

Description Below normal range.
Type integer or null
Read Only True
Added iLO6 1.05

Fans[{item}].MaximumValue Member of Thermal.v1_7_1.Thermal

Description Maximum value for CurrentReading.
Type integer or null
Read Only True
Added iLO6 1.05

Fans[{item}].MemberId Member of Thermal.v1_7_1.Thermal

Description This is the identifier for the member within the collection.
Type string
Read Only True
Added iLO6 1.05

Fans[{item}].MinimumValue Member of Thermal.v1_7_1.Thermal

Description Minimum value for CurrentReading.
Type integer or null
Read Only True
Added iLO6 1.05

Fans[{item}].Oem.Hpe.HotPluggable Member of Thermal.v1_7_1.Thermal

Description Indicates if the fan can be replaced while server is running.
Type boolean
Read Only True
Added iLO6 1.05

Fans[{item}].Oem.Hpe.IsLiquidCooling Member of Thermal.v1_7_1.Thermal

Description Indicates that the device is Liquid cooling device or not.
Type boolean
Read Only True
Added iLO6 1.05

Fans[{item}].Oem.Hpe.Location Member of Thermal.v1_7_1.Thermal

Description Indicates the component (i.e. CPU, Memory, and Storage) that the fan is being used to cool.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
System
System Board
I/O Board
CPU
Memory
Storage
Removable Media
Power Supply
Ambient
Chassis
Bridge Board
Exhaust
Processor Bay
IO Bay
Blade Slot
Virtual

Fans[{item}].Oem.Hpe.Redundant Member of Thermal.v1_7_1.Thermal

Description Indicates if the fan is in a redundant configuration.
Type boolean
Read Only True
Added iLO6 1.05

Fans[{item}].PhysicalContext Member of Thermal.v1_7_1.Thermal

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Room The room
Intake The intake point of the chassis
Exhaust The exhaust point of the chassis
Front The front of the chassis
Back The back of the chassis
Upper The upper portion of the chassis
Lower The lower portion of the chassis
CPU A Processor (CPU)
GPU A Graphics Processor (GPU)
Backplane A backplane within the chassis
SystemBoard The system board (PCB)
PowerSupply A power supply
VoltageRegulator A voltage regulator device
StorageDevice A storage device
NetworkingDevice A networking device
ComputeBay Within a compute bay
StorageBay Within a storage bay
NetworkBay Within a networking bay
ExpansionBay Within an expansion bay
PowerSupplyBay Within a power supply bay

Fans[{item}].Reading Member of Thermal.v1_7_1.Thermal

Description The current speed of the fan.
Type integer or null
Read Only True
Added iLO6 1.05

Fans[{item}].ReadingUnits Member of Thermal.v1_7_1.Thermal

Description Units for the CurrentReading.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value
Null
Percent

Fans[{item}].Status Member of Thermal.v1_7_1.Thermal See the Redfish standard schema and specification for information on common Status object.

Fans[{item}].UpperThresholdCritical Member of Thermal.v1_7_1.Thermal

Description Above normal range but not yet fatal.
Type integer or null
Read Only True
Added iLO6 1.05

Fans[{item}].UpperThresholdFatal Member of Thermal.v1_7_1.Thermal

Description Above normal range and is fatal.
Type integer or null
Read Only True
Added iLO6 1.05

Fans[{item}].UpperThresholdNonCritical Member of Thermal.v1_7_1.Thermal

Description Above normal range.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.FanPercentAdjust

Member of Thermal.v1_7_1.Thermal

Description System-wide setting for fan +/- percentage adjustment.
Type integer
Read Only False
Added iLO6 1.05

Oem.Hpe.FanPercentMinimum

Member of Thermal.v1_7_1.Thermal

Description System-wide setting for fan speed minimum percentage.
Type integer
Read Only False
Added iLO6 1.05

Oem.Hpe.ThermalConfiguration

Member of Thermal.v1_7_1.Thermal

Description The value of this property selects the fan cooling method for the system.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
OptimalCooling Provides the most efficient solution by configuring fan speeds to the minimum required to provide adequate cooling
IncreasedCooling Operates fans at a higher speed.
MaximumCooling Provides the maximum cooling available for the system.
EnhancedCooling Provides additional cooling to the processors, which can improve performance.
AcousticMode Edgeline-only option. Prioritizes minimizing noise from the enclosure.

Status

Member of Thermal.v1_7_1.Thermal See the Redfish standard schema and specification for information on common Status object.

Temperatures (array)

Member of Thermal.v1_7_1.Thermal

Temperatures is an array containing elements of:

Temperatures[{item}].@odata.id Member of Thermal.v1_7_1.Thermal

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Temperatures[{item}].CorrelatableID Member of Thermal.v1_7_1.Thermal

Description The CorrelatableID for this temperature sensor.
Type string or null
Read Only True
Added iLO6 1.05

Temperatures[{item}].LowerThresholdCritical Member of Thermal.v1_7_1.Thermal

Description Below normal range but not yet fatal.
Type integer or null
Read Only True
Added iLO6 1.05

Temperatures[{item}].LowerThresholdFatal Member of Thermal.v1_7_1.Thermal

Description Below normal range and is fatal.
Type integer or null
Read Only True
Added iLO6 1.05

Temperatures[{item}].LowerThresholdNonCritical Member of Thermal.v1_7_1.Thermal

Description Below normal range.
Type integer or null
Read Only True
Added iLO6 1.05

Temperatures[{item}].MaximumValue Member of Thermal.v1_7_1.Thermal

Description Maximum value for CurrentReading.
Type integer or null
Read Only True
Added iLO6 1.05

Temperatures[{item}].MemberId Member of Thermal.v1_7_1.Thermal

Description This is the identifier for the member within the collection.
Type string
Read Only True
Added iLO6 1.05

Temperatures[{item}].MinimumValue Member of Thermal.v1_7_1.Thermal

Description Minimum value for CurrentReading.
Type integer or null
Read Only True
Added iLO6 1.05

Temperatures[{item}].Oem.Hpe.CriticalTempUserThreshold Member of Thermal.v1_7_1.Thermal

Description User provided temperature threshold value for the sensor that results in a critical alert.
Type integer
Read Only True
Added iLO6 1.05

Temperatures[{item}].Oem.Hpe.LocationXmm Member of Thermal.v1_7_1.Thermal

Description The location of the sensor, in millimeters, along the X axis from the logical reference point.
Type integer
Read Only True
Added iLO6 1.05

Temperatures[{item}].Oem.Hpe.LocationYmm Member of Thermal.v1_7_1.Thermal

Description The location of the sensor, in millimeters, along the Y axis from the logical reference point.
Type integer
Read Only True
Added iLO6 1.05

Temperatures[{item}].Oem.Hpe.LocationZmm Member of Thermal.v1_7_1.Thermal

Description The location of the sensor, in millimeters, along the Z axis from the logical reference point.
Type integer
Read Only True
Added iLO6 1.05

Temperatures[{item}].Oem.Hpe.MainSensorName Member of Thermal.v1_7_1.Thermal

Description Sensor name of main temperature sensor that has atleast one sub sensor
Type string
Read Only True
Added iLO6 1.20

Temperatures[{item}].Oem.Hpe.WarningTempUserThreshold Member of Thermal.v1_7_1.Thermal

Description User provided temperature threshold value for the sensor that results in a warning alert.
Type integer
Read Only True
Added iLO6 1.05

Temperatures[{item}].PhysicalContext Member of Thermal.v1_7_1.Thermal

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Room The room.
Intake The air intake point or points or region of the chassis.
Exhaust The air exhaust point or points or region of the chassis.
LiquidInlet The liquid inlet point of the chassis.
LiquidOutlet The liquid outlet point of the chassis.
Front The front of the chassis.
Back The back of the chassis.
Upper The upper portion of the chassis.
Lower The lower portion of the chassis.
CPU A processor (CPU).
CPUSubsystem The entire processor (CPU) subsystem.
GPU A graphics processor (GPU).
GPUSubsystem The entire graphics processor (GPU) subsystem.
FPGA An FPGA.
Accelerator An accelerator.
ASIC An ASIC device, such as a networking chip or chipset component.
Backplane A backplane within the chassis.
SystemBoard The system board (PCB).
PowerSupply A power supply.
PowerSubsystem The entire power subsystem.
VoltageRegulator A voltage regulator device.
Rectifier A rectifier device.
StorageDevice A storage device.
NetworkingDevice A networking device.
ComputeBay Within a compute bay.
StorageBay Within a storage bay.
NetworkBay Within a networking bay.
ExpansionBay Within an expansion bay.
PowerSupplyBay Within a power supply bay.
Memory A memory device.
MemorySubsystem The entire memory subsystem.
Chassis The entire chassis.
Fan A fan.
CoolingSubsystem The entire cooling, or air and liquid, subsystem.
Motor A motor.
Transformer A transformer.
ACUtilityInput An AC utility input.
ACStaticBypassInput An AC static bypass input.
ACMaintenanceBypassInput An AC maintenance bypass input.
DCBus A DC bus.
ACOutput An AC output.
ACInput An AC input.
TrustedModule A trusted module.
Board A circuit board.
Transceiver A transceiver.
Battery A battery.
Pump A pump.

Temperatures[{item}].ReadingCelsius Member of Thermal.v1_7_1.Thermal

Description The current reading of the temperature sensor.
Type integer or null
Read Only True
Added iLO6 1.05

Temperatures[{item}].SensorNumber Member of Thermal.v1_7_1.Thermal

Description A numerical identifier to represent the temperature sensor.
Type integer or null
Read Only True
Added iLO6 1.05

Temperatures[{item}].Status Member of Thermal.v1_7_1.Thermal See the Redfish standard schema and specification for information on common Status object.

Temperatures[{item}].UpperThresholdCritical Member of Thermal.v1_7_1.Thermal

Description Above normal range but not yet fatal.
Type integer or null
Read Only True
Added iLO6 1.05

Temperatures[{item}].UpperThresholdFatal Member of Thermal.v1_7_1.Thermal

Description Above normal range and is fatal.
Type integer or null
Read Only True
Added iLO6 1.05

Temperatures[{item}].UpperThresholdNonCritical Member of Thermal.v1_7_1.Thermal

Description The noncritical temperature threshold.
Type integer or null
Read Only True
Added iLO6 1.05

Actions

HpeThermalExt.SetUserTempThreshold Member of Thermal.v1_7_1.Thermal The action to set a user defined threshold for a PCIe slot temperature sensor.

Parameters:

AlertType (string)

Alert type thrown when user defined temperature threshold is exceeded.

Value Description

|Warning|Generate a warning alert when user threshold exceeded.|

SensorNumber (integer)

Sensor number of the sensor to be monitored.

ThresholdValue (integer)

Temperature thershold that once passed will issue an alert.

ThermalMetrics

@odata.type: "#ThermalMetrics.v1_3_1.ThermalMetrics"

The ThermalMetrics schema represents the thermal metrics of a chassis.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/thermalsubsystem/thermalmetrics GET

PowerWatts

PowerWatts.Reading Member of ThermalMetrics.v1_3_1.ThermalMetrics

Description The sensor value
Type number or null
Read Only True
Added iLO6 1.63

TemperatureReadingsCelsius (array)

Member of ThermalMetrics.v1_3_1.ThermalMetrics

TemperatureReadingsCelsius is an array containing elements of:

TemperatureReadingsCelsius[{item}].DeviceName Member of ThermalMetrics.v1_3_1.ThermalMetrics

Description The name of the device.
Type string or null
Read Only True
Added iLO6 1.63

TemperatureReadingsCelsius[{item}].PhysicalContext Member of ThermalMetrics.v1_3_1.ThermalMetrics

Description Describes the area or device to which this voltage measurement applies.
Type string or null
Read Only True
Added iLO6 1.63

The following are the supported values:

Value Description
Null A value is temporarily unavailable
Room The room
Intake The intake point of the chassis
Exhaust The exhaust point of the chassis
Front The front of the chassis
Back The back of the chassis
Upper The upper portion of the chassis
Lower The lower portion of the chassis
CPU A Processor (CPU)
GPU A Graphics Processor (GPU)
Backplane A backplane within the chassis
SystemBoard The system board (PCB)
PowerSupply A power supply
VoltageRegulator A voltage regulator device
StorageDevice A storage device
NetworkingDevice A networking device
ComputeBay Within a compute bay
StorageBay Within a storage bay
NetworkBay Within a networking bay
ExpansionBay Within an expansion bay
PowerSupplyBay Within a power supply bay

TemperatureReadingsCelsius[{item}].Reading Member of ThermalMetrics.v1_3_1.ThermalMetrics

Description The sensor value.
Type integer or null
Read Only True
Added iLO6 1.63

TemperatureReadingsCelsius@odata.count

Member of ThermalMetrics.v1_3_1.ThermalMetrics

Description The number of items in a collection.
Type integer
Read Only True
Added iLO6 1.63

TemperatureSummaryCelsius

TemperatureSummaryCelsius.Ambient TemperatureSummaryCelsius.Ambient.DataSourceUri Member of ThermalMetrics.v1_3_1.ThermalMetrics

Description The link to the resource that provides the data for this sensor.
Type string or null
Read Only True
Added iLO6 1.63

TemperatureSummaryCelsius.Ambient.Reading Member of ThermalMetrics.v1_3_1.ThermalMetrics

Description The sensor value
Type integer or null
Read Only True
Added iLO6 1.63

ThermalSubsystem

@odata.type: "#ThermalSubsystem.v1_3_2.ThermalSubsystem"

This ThermalSubsystem schema contains the definition for the thermal subsystem of a chassis.

Resource Instances

Uri HTTP Allow
/redfish/v1/chassis/{item}/thermalsubsystem GET PATCH

Links to other Resources

Link Name Destination type
Fans Collection of Fan

Fans

The link to the summary of Fan Collection for this subsystem. Fans is a link ("@odata.id": URI) to another resource.

Oem.Hpe.FanPercentAdjust

Member of ThermalSubsystem.v1_3_2.ThermalSubsystem

Description System-wide setting for fan +/- percentage adjustment.
Type integer
Read Only False
Added iLO6 1.63

Oem.Hpe.FanPercentMinimum

Member of ThermalSubsystem.v1_3_2.ThermalSubsystem

Description System-wide setting for fan speed minimum percentage.
Type integer
Read Only False
Added iLO6 1.63

Oem.Hpe.ThermalConfiguration

Member of ThermalSubsystem.v1_3_2.ThermalSubsystem

Description The value of this property selects the fan cooling method for the system.
Type string
Read Only False
Added iLO6 1.63

The following are the supported values:

Value Description
OptimalCooling Provides the most efficient solution by configuring fan speeds to the minimum required to provide adequate cooling
IncreasedCooling Operates fans at a higher speed.
MaximumCooling Provides the maximum cooling available for the system.
EnhancedCooling Provides additional cooling to the processors, which can improve performance.
AcousticMode Edgeline-only option. Prioritizes minimizing noise from the enclosure.

Pumps

A link to the pumps for this equipment. Pumps is a link ("@odata.id": URI) to another resource.

ThermalMetrics

The link to the summary of thermal metrics for this subsystem. ThermalMetrics is a link ("@odata.id": URI) to another resource.

Triggers

@odata.type: "#Triggers.v1_0_0.Triggers"

The Triggers resource describes the a metric trigger, which apply to metrics.

Resource Instances

Uri HTTP Allow
/redfish/v1/telemetryservice/triggers/{item} GET PATCH

MetricProperties (array)

Member of Triggers.v1_0_0.Triggers

MetricProperties is an array containing elements of:

MetricProperties[{item}] Member of Triggers.v1_0_0.Triggers

Type string or null
Read Only True
Added iLO6 1.05

MetricType

Member of Triggers.v1_0_0.Triggers

Description Specifies the type of metric for which the trigger is configured.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Numeric The trigger is for numeric sensor.
Discrete The trigger is for a discrete sensor.

NumericThresholds

NumericThresholds.LowerCritical NumericThresholds.LowerCritical.Activation Member of Triggers.v1_0_0.Triggers

Description The direction of crossing that activates this threshold.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Increasing Value increases above the threshold.
Decreasing Value decreases below the threshold.
Either Value crosses the threshold in either direction.

NumericThresholds.LowerCritical.DwellTime Member of Triggers.v1_0_0.Triggers

Description The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated.
Type string or null
Read Only False
Added iLO6 1.05

NumericThresholds.LowerCritical.Reading Member of Triggers.v1_0_0.Triggers

Description The threshold value.
Type integer or null
Read Only False
Added iLO6 1.05

NumericThresholds.LowerWarning NumericThresholds.LowerWarning.Activation Member of Triggers.v1_0_0.Triggers

Description The direction of crossing that activates this threshold.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Increasing Value increases above the threshold.
Decreasing Value decreases below the threshold.
Either Value crosses the threshold in either direction.

NumericThresholds.LowerWarning.DwellTime Member of Triggers.v1_0_0.Triggers

Description The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated.
Type string or null
Read Only False
Added iLO6 1.05

NumericThresholds.LowerWarning.Reading Member of Triggers.v1_0_0.Triggers

Description The threshold value.
Type integer or null
Read Only False
Added iLO6 1.05

NumericThresholds.UpperCritical NumericThresholds.UpperCritical.Activation Member of Triggers.v1_0_0.Triggers

Description The direction of crossing that activates this threshold.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Increasing Value increases above the threshold.
Decreasing Value decreases below the threshold.
Either Value crosses the threshold in either direction.

NumericThresholds.UpperCritical.DwellTime Member of Triggers.v1_0_0.Triggers

Description The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated.
Type string or null
Read Only False
Added iLO6 1.05

NumericThresholds.UpperCritical.Reading Member of Triggers.v1_0_0.Triggers

Description The threshold value.
Type integer or null
Read Only False
Added iLO6 1.05

NumericThresholds.UpperWarning NumericThresholds.UpperWarning.Activation Member of Triggers.v1_0_0.Triggers

Description The direction of crossing that activates this threshold.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Increasing Value increases above the threshold.
Decreasing Value decreases below the threshold.
Either Value crosses the threshold in either direction.

NumericThresholds.UpperWarning.DwellTime Member of Triggers.v1_0_0.Triggers

Description The time interval over which the sensor reading must have passed through this Threshold value before the threshold is considered to be violated.
Type string or null
Read Only False
Added iLO6 1.05

NumericThresholds.UpperWarning.Reading Member of Triggers.v1_0_0.Triggers

Description The threshold value.
Type integer or null
Read Only False
Added iLO6 1.05

Status

Member of Triggers.v1_0_0.Triggers See the Redfish standard schema and specification for information on common Status object.

TriggerActions (array)

Member of Triggers.v1_0_0.Triggers

TriggerActions is an array containing elements of:

TriggerActions[{item}] Member of Triggers.v1_0_0.Triggers

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
LogToLogService Upon a trigger, record in a log.
RedfishEvent Upon a trigger, send a Redfish Event message of type MetricReport.

TriggersCollection

@odata.type: "#TriggersCollection.TriggersCollection"

A Collection of Triggers resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/telemetryservice/triggers GET

Links to other Resources

Link Name Destination type
Members[] Triggers

Members (array)

Member of TriggersCollection.TriggersCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of TriggersCollection.TriggersCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of TriggersCollection.TriggersCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05

UpdateService

@odata.type: "#UpdateService.v1_2_1.UpdateService"

The UpdateService resource describes the Update Service. It represents the properties for the service itself and has links to collections of firmware and software inventory.

Resource Instances

Uri HTTP Allow
/redfish/v1/updateservice GET PATCH

Links to other Resources

Link Name Destination type
Oem/Hpe/InstallSets Collection of HpeComponentInstallSet
Oem/Hpe/ComponentRepository Collection of HpeComponent
FirmwareInventory Collection of SoftwareInventory
SoftwareInventory Collection of SoftwareInventory
Oem/Hpe/UpdateTaskQueue Collection of HpeComponentUpdateTask

FirmwareInventory

Link to Firmware Inventory. FirmwareInventory is a link ("@odata.id": URI) to another resource.

HttpPushUri

Member of UpdateService.v1_2_1.UpdateService

Description The URI to which a client may POST an update image.
Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Oem.Hpe.Accept3rdPartyFirmware

Member of UpdateService.v1_2_1.UpdateService

Description Enable or disable support for 3rd party firmware update packages.
Type boolean
Read Only False
Added iLO6 1.05

Oem.Hpe.BundleUpdateReport

Link to the Bundle Update report. BundleUpdateReport is a link ("@odata.id": URI) to another resource.

Oem.Hpe.Capabilities

Oem.Hpe.Capabilities.BundleDowngradeSupport Member of UpdateService.v1_2_1.UpdateService

Description Indicates whether iLO supports downgrade capability for cloud based updates.
Type boolean
Read Only True
Added iLO6 1.10

Oem.Hpe.Capabilities.COMBootToUefiShellSupport Member of UpdateService.v1_2_1.UpdateService

Description Indicates whether iLO supports booting to Uefi shell for cloud based updates.
Type boolean
Read Only True
Added iLO6 1.40

Oem.Hpe.Capabilities.COMVCSupport Member of UpdateService.v1_2_1.UpdateService

Description Indicates whether iLO supports pending reset for bundle update.
Type boolean
Read Only True
Added iLO6 1.40

Oem.Hpe.Capabilities.HostPoweroffSupport Member of UpdateService.v1_2_1.UpdateService

Description Indicates whether iLO supports HOST power off.
Type boolean
Read Only True
Added iLO6 1.56

Oem.Hpe.Capabilities.OfflineRuntimeBundleUpdate Member of UpdateService.v1_2_1.UpdateService

Description Indicates whether iLO supports offline type D installation.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
ProductionMode iLO supports offline type D installation in production security state only.
ProductionAndHighSecurityMode iLO supports offline type D installation in Production and High security state only.
AllModes iLO supports offline type D installation in all security states viz, Production, High security, FIPS and CNSA.

Oem.Hpe.Capabilities.PLDMFirmwareUpdate Member of UpdateService.v1_2_1.UpdateService

Description Indicates whether iLO supports PLDM firmware updates.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.Capabilities.UpdateFWPKG Member of UpdateService.v1_2_1.UpdateService

Description Indicates whether iLO supports FWPKG 2.0 firmware images.
Type boolean
Read Only True
Added iLO6 1.05

Oem.Hpe.ComponentRepository

Link to the Component Repository. ComponentRepository is a link ("@odata.id": URI) to another resource.

Oem.Hpe.CurrentTime

Member of UpdateService.v1_2_1.UpdateService

Description ISO 8601 Redfish-style time string of the current iLO time (the reference for all scheduling)
Type string
Read Only True
Added iLO6 1.05
Format date-time

Oem.Hpe.DowngradePolicy

Member of UpdateService.v1_2_1.UpdateService

Description Can be used to restrict the firmware downgrade.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
AllowDowngrade Downgrading firmware is allowed.
RecoveryDowngrade Downgrading firmware is allowed by a user with the Recovery Set privilege.
NoDowngrade Downgrading firmware is not allowed. This is a permanent setting and cannot be undone.

Oem.Hpe.FirmwareIntegrity

Oem.Hpe.FirmwareIntegrity.EnableBackgroundScan Member of UpdateService.v1_2_1.UpdateService

Description Enables or disables background scan of critical firmware.
Type boolean
Read Only False
Added iLO6 1.05

Oem.Hpe.FirmwareIntegrity.LastFailedImageUri Member of UpdateService.v1_2_1.UpdateService

Description This is a link to the binary image of the firmware that failed an integrity check and is intended for diagnostic purposes.
Type string or null
Read Only True
Added iLO6 1.05
Format uri-reference

Oem.Hpe.FirmwareIntegrity.LastScanResult Member of UpdateService.v1_2_1.UpdateService

Description The firmware integrity scan engine status.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
OK The last firmware integrity scan completed without finding any issues.
Repaired The last firmware integrity scan successfully repaired an issue. Refer to the event log for details.
Failure The last firmware integrity scan failed to complete or repair an issue. Refer to the event log for details.
Stopped The last firmware integrity scan was stopped prior to completion. Refer to the event log for details.

Oem.Hpe.FirmwareIntegrity.LastScanTime Member of UpdateService.v1_2_1.UpdateService

Description The time stamp of the last firmware integrity scan.
Type string or null
Read Only True
Added iLO6 1.05
Format date-time

Oem.Hpe.FirmwareIntegrity.OnIntegrityFailure Member of UpdateService.v1_2_1.UpdateService

Description Sets the policy for how the firmware integrity check handles integrity failures.
Type string
Read Only False
Added iLO6 1.05

The following are the supported values:

Value Description
LogOnly Log failures to the iLO event log but do not automatically attempt to repair.
LogAndRepairAutomatically Log failures to the iLO event log and automatically attempt to repair.

Oem.Hpe.FirmwareIntegrity.ScanEveryDays Member of UpdateService.v1_2_1.UpdateService

Description Sets the interval between firmware integrity scans in 24 hour increments.
Type integer or null
Read Only False
Added iLO6 1.05

Oem.Hpe.FlashProgressPercent

Member of UpdateService.v1_2_1.UpdateService

Description This is the percent complete for an iLO flash operation. It is only valid when State is Updating.
Type integer or null
Read Only True
Added iLO6 1.05

Oem.Hpe.InstallSets

Link to the Install Sets collection. InstallSets is a link ("@odata.id": URI) to another resource.

Oem.Hpe.InvalidImageRepository

Link to the Invalid Image Repository. InvalidImageRepository is a link ("@odata.id": URI) to another resource.

Oem.Hpe.MaintenanceWindows

Link to the Maintenance Windows. MaintenanceWindows is a link ("@odata.id": URI) to another resource.

Oem.Hpe.Result

Oem.Hpe.Result.MessageArgs (array) Member of UpdateService.v1_2_1.UpdateService

MessageArgs is an array containing elements of:

MessageArgs[{item}] Member of UpdateService.v1_2_1.UpdateService

Type string
Read Only True
Added iLO6 1.05

Oem.Hpe.Result.MessageId Member of UpdateService.v1_2_1.UpdateService

Description The key for this message that can be used to look up the message in a message registry.
Type string
Read Only False
Added iLO6 1.05

Oem.Hpe.State

Member of UpdateService.v1_2_1.UpdateService

Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Idle The update service is idle.
Uploading The update service is receiving a new component.
Verifying The update service is verifying the integrity of a new component.
Writing The update service is writing a new component to the iLO Repository.
Updating The update service is updating (flashing) firmware.
Complete The update service has completed up upload or update operation.
Error The upload service encountered an error. See Result for detail.

Oem.Hpe.UpdateTaskQueue

Link to the Update Task Queue. UpdateTaskQueue is a link ("@odata.id": URI) to another resource.

Oem.Hpe.UploadCurrentEtag

Member of UpdateService.v1_2_1.UpdateService

Description client-supplied etag (during component upload) indicating to what UploadStatus is reporting upon.
Type string
Read Only True
Added iLO6 1.05

ServiceEnabled

Member of UpdateService.v1_2_1.UpdateService

Description Indicates if the Update Service is enabled.
Type boolean or null
Read Only True
Added iLO6 1.05

SoftwareInventory

Link to Software Inventory. This is only available when the Agentless Management Service is running. SoftwareInventory is a link ("@odata.id": URI) to another resource.

Actions

UpdateService.SimpleUpdate Member of UpdateService.v1_2_1.UpdateService

Parameters:

Username (string)

The username credential required for authentication to fetch image.

TransferProtocol (string)

Value Description
HTTP Hypertext Transfer Protocol
HTTPS HTTP Secure protocol

ImageURI (string)

Password (string)

The password credential required for authentication to fetch image.

Targets (array)

Target Redfish URI

HpeiLOUpdateServiceExt.DeleteInstallSets Member of UpdateService.v1_2_1.UpdateService

Parameters:

IncludeRecoverySet (boolean)

HpeiLOUpdateServiceExt.DeleteUnlockedComponents Member of UpdateService.v1_2_1.UpdateService There are no parameters for this action.

HpeiLOUpdateServiceExt.DeleteMaintenanceWindows Member of UpdateService.v1_2_1.UpdateService There are no parameters for this action.

HpeiLOUpdateServiceExt.AddFromUri Member of UpdateService.v1_2_1.UpdateService

Parameters:

UpdateTarget (boolean)

If true the action will flash the target.

UpdateRecoverySet (boolean)

If true the action will update the system recovery set if it contains a matching target after the repository is updated.

UploadCurrentEtag (string)

client-supplied etag (during component upload) indicating to what UploadStatus is reporting upon.

VirtualMedia

@odata.type: "#VirtualMedia.v1_3_0.VirtualMedia"

The VirtualMedia resource describes the BMC virtual media feature.

Resource Instances

Uri HTTP Allow
/redfish/v1/managers/{item}/virtualmedia/{item} GET PATCH

ConnectedVia

Member of VirtualMedia.v1_3_0.VirtualMedia

Description Specifies how the virtual media is connected to the server.
Type string or null
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
Null A value is temporarily unavailable
NotConnected No current connection.
URI Connected to a URI location.
Applet Connected to a client application.

Image

Member of VirtualMedia.v1_3_0.VirtualMedia

Description The valid URI indicating the image that is mounted on this server. A null value indicates that no image exists.
Type string or null
Read Only False
Added iLO6 1.05
Format uri-reference

ImageName

Member of VirtualMedia.v1_3_0.VirtualMedia

Description The name of the image that is mounted on this server. This is usually provided when a URL image is mounted through scripted virtual media.
Type string or null
Read Only True
Added iLO6 1.05

Inserted

Member of VirtualMedia.v1_3_0.VirtualMedia

Description Indicates whether the virtual media is mounted on the server.
Type boolean or null
Read Only False
Added iLO6 1.05

MediaTypes (array)

Member of VirtualMedia.v1_3_0.VirtualMedia

MediaTypes is an array containing elements of:

MediaTypes[{item}] Member of VirtualMedia.v1_3_0.VirtualMedia

Description The array of supported media types for this connection.
Type string
Read Only True
Added iLO6 1.05

The following are the supported values:

Value Description
CD A CD-ROM format (ISO) image.
Floppy A floppy disk image.
USBStick An emulation of a USB storage device.
DVD A DVD-ROM format image.

Oem.Hpe.BootOnNextServerReset

Member of VirtualMedia.v1_3_0.VirtualMedia

Description If set to true, the server will boot to this image on the next server reboot. The image will be ejected automatically on the second server reboot so that the server does not boot to this image twice.
Type boolean
Read Only False
Added iLO6 1.05

TransferProtocolType

Member of VirtualMedia.v1_3_0.VirtualMedia

Description Network Protocol to use with the image
Type string
Read Only True
Added iLO6 1.10

The following are the supported values:

Value Description
CIFS Common Internet File System protocol.
FTP File Transfer Protocol.
SFTP Secure File Transfer Protocol.
HTTP Hypertext Transfer Protocol.
HTTPS HTTP Secure protocol.
NFS Network File System protocol.
SCP Secure File Copy protocol.
TFTP Trivial File Transfer Protocol.
OEM A protocol defined by the manufacturer.

WriteProtected

Member of VirtualMedia.v1_3_0.VirtualMedia

Description Indicates whether the virtual media is protected against write operations.
Type boolean or null
Read Only False
Added iLO6 1.05

Actions

VirtualMedia.InsertMedia Member of VirtualMedia.v1_3_0.VirtualMedia

Parameters:

TransferProtocolType (string)

Network Protocol to use with the image

Value Description
FTP File Transfer Protocol.
HTTP Hypertext Transfer Protocol.
CIFS Common Internet File System protocol.
HTTPS HTTP Secure protocol.
SFTP Secure File Transfer Protocol.
NFS Network File System protocol.
OEM A protocol defined by the manufacturer.
TFTP Trivial File Transfer Protocol.
SCP Secure File Copy protocol.

Image (string)

The URI of the remote media to attach to the virtual media.

WriteProtected (boolean)

Indicates whether the virtual media is protected against write operations. If this parameter is not provided by the client, the service shall default this value to be true.

Inserted (boolean)

Indicates if the image is to be treated as inserted upon completion of the action. If this parameter is not provided by the client, the service shall default this value to be true.

VirtualMedia.EjectMedia Member of VirtualMedia.v1_3_0.VirtualMedia There are no parameters for this action.

HpeiLOVirtualMedia.InsertVirtualMedia Member of VirtualMedia.v1_3_0.VirtualMedia

Parameters:

Certificate (string)

A PEM encoded X509 certificate used to validate the https server.

Image (string)

A URL for an ISO, BIN, or IMG file locating the virtual media image.

Intent (string)

A text description of the reason for this action invocation.

Signature (string)

A RSA2048 SHA-256 signature validating the provided Intent (Base64 encoded).

WriteProtected (boolean)

Indicates whether the virtual media is protected against write operations.

HpeiLOVirtualMedia.EjectVirtualMedia Member of VirtualMedia.v1_3_0.VirtualMedia

Parameters:

Intent (string)

A text description of the reason for this action invocation.

Signature (string)

A RSA2048 SHA-256 signature validating the provided Intent (Base64 encoded).

VirtualMediaCollection

@odata.type: "#VirtualMediaCollection.VirtualMediaCollection"

A Collection of VirtualMedia resource instances.

Resource Instances

Uri HTTP Allow
/redfish/v1/managers/{item}/virtualmedia GET

Links to other Resources

Link Name Destination type
Members[] VirtualMedia

Members (array)

Member of VirtualMediaCollection.VirtualMediaCollection

Members is an array containing elements of:

Members[{item}].@odata.id Member of VirtualMediaCollection.VirtualMediaCollection

Type string
Read Only True
Added iLO6 1.05
Format uri-reference

Members@odata.count

Member of VirtualMediaCollection.VirtualMediaCollection

Description The total number of collection members.
Type integer
Read Only True
Added iLO6 1.05