The logical drive is currently encrypted and has received a request to rekey all data with a new logical drive encryption key.The logical drive is online.
Cleared By
Health Category
Storage
Severity
OK
Resolution
None.
iLOEvents.DrvArrLogDrvNoAccessEncryptedMissingKey
Description
The logical drive is currently encrypted and cannot be accessed because the array controller has not yet received the encryption key from Management Processor.
At least one physical drive has failed, but no data has been lost.
iLOEvents.DrvArrLogDrvRekeyInProgress
Description
The logical drive is currently encrypted and all data is currently being rekeyed with a new logical drive key using the background capacity expansion transformation task.
The logical drive has received a request to transform from unencrypted to encrypted but this process has not yet started.The unencrypted logical drive is currently online.
Write cache operations have been permanently disabled because the number of cache lines experiencing excessive ECC errors has reached the preset limit.
Write cache operations have been permanently disabled because data could not be written to write cache memory in duplicate due to the detection of parity errors.
Write cache operations have been temporarily disabled because the cache module board has been configured but is not currently attached to the controller.
If configured for auto-recovery, the repair attempt will happen automatically. If not configured or if it does not succeed, then manual recovery is needed. If the anomaly was detected as part of OS boot time validation, then a manual recovery is needed.
iLOEvents.HeNvdimmControllerFirmwareError
Description
NVDIMM Error - Controller Firmware Error. The controller firmware has been corrupted. The OS will not use the NVDIMM.
Cleared By
Health Category
Memory
Severity
Critical
Resolution
Re-program the firmware to restore NVDIMM functionality.
iLOEvents.HeNvdimmLifecycleWarning
Description
NVDIMM Lifecycle Warning. NVDIMM lifetime has reached.
Cleared By
Health Category
Memory
Severity
Warning
Resolution
Backup NVDIMM contents to other media to preserve data and replace NVDIMM.
iLOEvents.HeNvdimmSanitizationOk
Description
NVDIMM Sanitization Ok. This NVDIMM-N was selected for Sanitizing/Erasing. All data saved in the NVDIMM has been erased.
Cleared By
Health Category
Memory
Severity
Warning
Resolution
Re-program the firmware to restore NVDIMM functionality.
iLOEvents.HoodRemoved
Description
System hood is removed or not in a properly installed state. This situation may result in improper cooling of the system due to air flow changes caused by the missing hood.
Ensure that the server chassis hood was intentionally removed and the server is secure. Replace the cover, ensuring it is properly installed. Verify the system is in working order.
iLOEvents.HoodRemovedOnPowerOff
Description
BIOS detected a system hood removal when server power was off.
Management Processor to Insight Remote Support or Insight Online communication failed.
Cleared By
Health Category
Remotesupport
Severity
Warning
Resolution
Please check the connectivity to Insight Remote Support or Insight Online Host.
iLOEvents.IPMIWatchdogTimerReset
Description
The Management processor detected a watchdog timer timeout. The failsafe timer was not periodically addressed after it was armed in the operating system.
Cleared By
Health Category
None
Severity
Warning
Resolution
Review management processor event logs and any relevant operating system history for additional information.
iLOEvents.IdeAtaSecureEraseFailed
Description
Secure Erase of SATA drive has failed.
Cleared By
Health Category
Storage
Severity
Critical
Resolution
Please refer the IML Troubleshooting guide or click on Learn More link for additional information and any necessary action to be taken.
iLOEvents.IndicatorLEDStateChanged
Description
The state of the indicator LED has changed
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.InterlockFailureErrorPowerOn
Description
The server had a power fault that occurred while attempting to power on.
Cleared By
Health Category
Power
Severity
Critical
Resolution
Refer to the Integrated Management Log for details. Remove and then reinstall the failed device. Attempt to boot the server.
iLOEvents.InterlockFailureErrorRuntime
Description
The server was shut down due to a power fault that occurred while it was powered on.
Cleared By
Health Category
Power
Severity
Critical
Resolution
Refer to the Integrated Management Log for details. Remove and then reinstall the failed device. Attempt to boot the server.
iLOEvents.InterlockFailureErrorStandby
Description
The server had a power fault that occurred while it was powered off.
Cleared By
Health Category
Power
Severity
Critical
Resolution
Refer to the Integrated Management Log for details. Remove and then reinstall the failed device. Attempt to boot the server.
iLOEvents.InterlockFailureErrorUnknown
Description
The server had a power fault but the reason is unknown.
Cleared By
Health Category
Power
Severity
Critical
Resolution
Refer to the Integrated Management Log for details. Remove and then reinstall the failed device. Attempt to boot the server.
iLOEvents.IntrusionHWInstalled
Description
System intrusion alert hardware is installed.
Cleared By
Health Category
None
Severity
OK
Resolution
None.
iLOEvents.IntrusionHWRemoved
Description
System intrusion alert hardware is removed.
Cleared By
Health Category
None
Severity
OK
Resolution
There is no action required if the removal of the hardware is expected. If the hardware was not intentionally removed, please verify cable connection.
iLOEvents.MetricValueBelowLowerThreshold
Description
Metric value is below user defined lower threshold.
Cleared By
Health Category
None
Severity
Warning
Resolution
Please check the current configured server workload.
iLOEvents.MetricValueExceededUpperThreshold
Description
Metric value exceeded user defined upper threshold.
Cleared By
Health Category
None
Severity
Warning
Resolution
Please check the current configured server workload.
iLOEvents.MirroredMemoryEngaged
Description
Advanced Memory Protection Mirrored Memory Engaged. The Advanced Memory Protection subsystem has detected a memory fault. Mirrored Memory has been activated.
Cleared By
Health Category
Memory
Severity
Warning
Resolution
Replace the faulty memory.
iLOEvents.AlternateGPUManagementInterfaceActive
Description
Management Processor has detected a change in the management interface usage for health monitoring
Cleared By
Health Category
None
Severity
OK
Resolution
Schedule a server maintenance reboot. Also, collect and submit this server's AHS log to customer support.
iLOEvents.NoGPUManagementInterfaceActive
Description
Management Processor has detected a change in the management interface usage for health monitoring
Cleared By
Health Category
None
Severity
OK
Resolution
None.
iLOEvents.PrimaryGPUManagementInterfaceActive
Description
Management Processor has detected a change in the management interface usage for health monitoring
Cleared By
Health Category
None
Severity
OK
Resolution
None.
iLOEvents.NVMeSecureEraseFailed
Description
Secure Erase of NVMe drive has failed.
Cleared By
Health Category
Storage
Severity
Critical
Resolution
Please refer the IML Troubleshooting guide or click on Learn More link for additional information and any necessary action to be taken.
iLOEvents.NicAllLinksDown
Description
The physical adapter has had a function up at any point and transitions to having all of its functions down.
Check the connection to the adapter and validate the connectivity from the server to any external device, including the cabling. If no problems are found, the adapter or other connectivity device may need replacement.
iLOEvents.NicAllLinksDownRepaired
Description
The physical adapter has had a function up at any point and transitions to having all of its functions down and then has one if its functions return to up.
Cleared By
Health Category
Network
Severity
OK
Resolution
None.
iLOEvents.NicConnectivityLost
Description
The physical adapter in a single adapter configuration failed or at least one physical adapter in a logical adapter group failed.
Check the connection to the adapter and validate the connectivity from the server to any external device, including the cabling. If no problems are found, the adapter or other connectivity device may need replacement.
iLOEvents.NicConnectivityRestored
Description
The physical adapter in a single adapter configuration returns to the OK condition or at least one physical adapter in a logical adapter group returns to the OK condition.
One or more POST errors occurred. Power On Self-Test (POST) errors occur during the server restart process. Details of the POST error messages can be found in Integrated Management Log
Cleared By
Health Category
Logs
Severity
Warning
Resolution
Refer to the Integrated Management Log for details on the Power on self-test error.
iLOEvents.PciResetFail
Description
System is unable to perform a reset on the PCI controller in slot.
Refer to the Integrated Management Log for details. Try the following steps until the error no longer occurs: a) Remove the AC power, and then restore AC power. Attempt to boot the server. (b) Remove and then reinstall the failed device. Attempt to boot the server. (c) Swap the failed device with a known good device and attempt to boot the server.
iLOEvents.PowerFailureErrorBadFuse
Description
The server was shut down because one or more fuses tripped.
Refer to the Integrated Management Log for details. Try the following steps until the error no longer occurs: a) Remove the AC power, and then restore AC power. Attempt to boot the server. (b) Remove and then reinstall the failed device. Attempt to boot the server. (c) Swap the failed device with a known good device and attempt to boot the server.
iLOEvents.PowerFailureErrorInputPowerLoss
Description
The server was shut down because the input power source was removed.
Refer to the Integrated Management Log for details. Try the following steps until the error no longer occurs: a) Remove the AC power, and then restore AC power. Attempt to boot the server. (b) Remove and then reinstall the failed device. Attempt to boot the server. (c) Swap the failed device with a known good device and attempt to boot the server.
iLOEvents.PowerFailureErrorTempAboveCritical
Description
The server was shut down because a temperature sensor was above the critical threshold.
Refer to the Integrated Management Log for details. Try the following steps until the error no longer occurs: a) Remove the AC power, and then restore AC power. Attempt to boot the server. (b) Remove and then reinstall the failed device. Attempt to boot the server. (c) Swap the failed device with a known good device and attempt to boot the server.
iLOEvents.PowerFailurePowerOn
Description
The server had a power fault while attempting to power on.
Refer to the Integrated Management Log for details. Try the following steps until the error no longer occurs: a) Remove the AC power, and then restore AC power. Attempt to boot the server. (b) Remove and then reinstall the failed device. Attempt to boot the server. (c) Swap the failed device with a known good device and attempt to boot the server.
iLOEvents.PowerFailureRuntime
Description
The server was shut down due to a power fault that occurred while it was powered on.
Refer to the Integrated Management Log for details. Try the following steps until the error no longer occurs: a) Remove the AC power, and then restore AC power. Attempt to boot the server. (b) Remove and then reinstall the failed device. Attempt to boot the server. (c) Swap the failed device with a known good device and attempt to boot the server.
iLOEvents.PowerFailureStandby
Description
The server had a power fault that occurred while it was powered off.
Refer to the Integrated Management Log for details. Try the following steps until the error no longer occurs: a) Remove the AC power, and then restore AC power. Attempt to boot the server. (b) Remove and then reinstall the failed device. Attempt to boot the server. (c) Swap the failed device with a known good device and attempt to boot the server.
iLOEvents.PowerFailureUnknown
Description
The server had a power fault but the reason is unknown.
Refer to the Integrated Management Log for details. Try the following steps until the error no longer occurs: a) Remove the AC power, and then restore AC power. Attempt to boot the server. (b) Remove and then reinstall the failed device. Attempt to boot the server. (c) Swap the failed device with a known good device and attempt to boot the server.
iLOEvents.PowerProtectionFault
Description
System Board Power Protection Fault.
Cleared By
Health Category
None
Severity
Critical
Resolution
Check the Integrated Management Log (IML) for additional information.
iLOEvents.PowerRedundancyLost
Description
The fault tolerant power supplies have lost redundancy.
Processor status changed. Processor can be brought down to Stop state and removed from O.S Active set
Cleared By
Health Category
Processor
Severity
Warning
Resolution
Update the system firmware. If the issue persists, check the Integrated Management Log (IML) for recommended action.
iLOEvents.ProcessorStatusDisabled
Description
Processor status changed. Processor brought down to Stop state and removed from O.S Active set
Cleared By
Health Category
Processor
Severity
Warning
Resolution
Update the system firmware. If the issue persists, check the Integrated Management Log (IML) for recommended action.
iLOEvents.ProcessorStatusFailed
Description
Processor status changed. Processor brought down to Stop state and removed from O.S Active set
Cleared By
Health Category
Processor
Severity
Critical
Resolution
Update the system firmware. If the issue persists, check the Integrated Management Log (IML) for recommended action.
iLOEvents.ProcessorStatusOK
Description
Processor status changed. Processor brought back to Running state and made member of O.S Active set
Cleared By
Health Category
Processor
Severity
OK
Resolution
None.
iLOEvents.ProcessorStatusUnknown
Description
Processor status changed. Processor can be brought down to Stop state and removed from O.S Active set or Brought back to Running state and made member of O.S Active set
Cleared By
Health Category
Processor
Severity
Warning
Resolution
Update the system firmware. If the issue persists, check the Integrated Management Log (IML) for recommended action.
Check error condition and the Integrated Management Log (IML) for additional information.
iLOEvents.PwrSupplyErrorRepaired
Description
System Power Supply Error Repaired.
Cleared By
Health Category
Power
Severity
OK
Resolution
None
iLOEvents.ResourceAdded
Description
Resource added.
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.ResourceRemoved
Description
Resource removed.
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.ResourceStatusChanged
Description
Resource status changed.
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.ResourceUpdated
Description
Resource updated.
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.SEDPassPhraseFailed
Description
Device Encryption Error. Enabling or Disabling encryption/modifying pass phrase failed.
Cleared By
Health Category
None
Severity
Critical
Resolution
Retry with correct pass phrase. If issue persists contact HPE support.
iLOEvents.SEDUnlockFailed
Description
Three wrong attempts were made to unlock Self Encrypting Device. The device will be locked until the next reboot.
Cleared By
Health Category
None
Severity
Warning
Resolution
Reboot server and retry.
iLOEvents.SNMPAuthenticationFailure
Description
An unauthorized user attempted to access the Management Processor via SNMP
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.SPISecureEraseFailed
Description
Secure Erase of System Firmware Configuration has failed.
Cleared By
Health Category
None
Severity
Critical
Resolution
Retry Secure Erase. Please contact HPE Support if issue persists.
iLOEvents.SecureBootAuthCertFail
Description
Secure Boot Authentication Failure - The image was not authorized due to revoked certificate(s) and was not executed.
Cleared By
Health Category
None
Severity
Warning
Resolution
Update the image to a new version where the certificate used to sign the image and the image hash are not in the Secure Boot forbidden database (DBX).
iLOEvents.PMMHealthFailure
Description
An Intel Optane PMem for HPE Module has experienced an issue and is no longer operational/resilient.
Cleared By
Health Category
Memory
Severity
Critical
Resolution
Backup Intel Optane PMem for HPE contents to other media to preserve data and replace the PMem.
iLOEvents.PMMLessUsageRemainingAlert
Description
An Intel Optane PMem for HPE Module Percentage Remaining Alert. The Intel Optane PMem for HPE Module has less usage remaining. Future errors on this Persistent Memory Module may result in loss of data.
Cleared By
Health Category
Memory
Severity
Critical
Resolution
Backup Persistent Memory Module contents to other media to preserve data immediately and replace the PMem.
iLOEvents.PMMConfigError
Description
One or more PMem Configuration errors occurred.
Cleared By
Health Category
Memory
Severity
Critical
Resolution
Review documentation for more information on supported configurations.
iLOEvents.PMMShutdownWarning
Description
Intel Optane PMem for HPE Module Health Warning. Intel Optane PMem for HPE Module reported an unsafe shutdown.
Cleared By
Health Category
Memory
Severity
Critical
Resolution
Check Integrated Management Log (IML) for additional information. If the issue persists, check if the system firmware is latest, including the system programmable logic device and system ROM. Check power supply and replace if needed.
iLOEvents.SecureBootAuthFail
Description
Secure Boot Authentication Failure - The image failed authentication and was not executed.
Cleared By
Health Category
None
Severity
Warning
Resolution
Update the image to known good trusted version. If current image is trusted, then update the Secure Boot allowed database (DB) with the certificate or image hash.
iLOEvents.SecurityOverrideDisengaged
Description
Security override disengaged. Management Processor firmware has detected the security override jumper has been toggled to the disengaged position.
Cleared By
Health Category
None
Severity
OK
Resolution
None.
iLOEvents.SecurityOverrideEngaged
Description
Security override engaged. Management Processor firmware has detected the security override jumper has been toggled to the engaged position.
Cleared By
Health Category
None
Severity
OK
Resolution
None.
iLOEvents.ServerHardwareSignatureChanged
Description
The server hardware signature has changed. This can be caused by addition or removal of Mezziane cards or relocation of the server.
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.ServerOperational
Description
The server is operational again. The server has previously been shutdown due to a thermal anomaly on the server and has just become operational again.
Cleared By
Health Category
Thermal
Severity
Warning
Resolution
None.
iLOEvents.ServerPostComplete
Description
The server has reached Power On Self Test complete.
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.ServerPostDiscoveryComplete
Description
The server has completed device discovery.
Cleared By
Health Category
Security
Severity
OK
Resolution
None.
iLOEvents.ServerPowerOnFailure
Description
A request was made to power on the server, however the server could not be powered on due to a failure condition.
Shutdown the storage system as soon as possible. Ensure that the storage system environment is being cooled properly and that no components are overheated.
iLOEvents.StorageSystemTemperatureFailed
Description
The storage system temperature could permanently damage the system.The storage system will automatically shutdown.
Shutdown the storage system as soon as possible. Ensure that the storage system environment is being cooled properly and that no components are overheated.
iLOEvents.StorageSystemTemperatureOK
Description
The storage system temperature is within normal operating range.
Cleared By
Health Category
Thermal
Severity
OK
Resolution
None.
iLOEvents.StorageSystemNotConnected
Description
The storage system is not connected to the controller.
Re-seat the processor and update to the latest firmware. If the issue persists contact support.
iLOEvents.iLODriveComponentAdded
Description
A component was added to the iLO Drive.
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.SecurityStateChange
Description
Security state changed.
Cleared By
Health Category
None
Severity
OK
Resolution
No Action
iLOEvents.iLOReset
Description
Management Processor reset pending
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.iLORestServicesStarted
Description
RESTful services started.
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.RemoteSupportUnregistrationComplete
Description
The server was unregistered from Remote Support.
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.RemoteSupportRegistrationComplete
Description
The server was registered to Remote Support.
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.EnclosureManagerFirmwareMismatch
Description
The Enclosure Manager firmware version is below the minimum supported version.
Cleared By
Health Category
None
Severity
Critical
Resolution
Update the firmware.
iLOEvents.InletAmbientPreCautionThresAlert
Description
Inlet Ambient temperature sensor user defined Pre-Caution threshold level exceeded.
Cleared By
Health Category
Severity
Warning
Resolution
None.
iLOEvents.LiquidCoolingModuleFailed
Description
The specified Liquid Cooling module has failed.
Cleared By
Health Category
Thermal
Severity
Critical
Resolution
Check Server documentation to be sure the liquid cooling module configuration meets the functional requirements of the server and replace the Module accordingly.
iLOEvents.LiquidCoolingModuleDegraded
Description
The specified Liquid cooling Module is now in a degraded state.
Cleared By
Health Category
Thermal
Severity
Critical
Resolution
Check Server documentation to be sure the liquid cooling module configuration meets the functional requirements of the server and replace the Module accordingly.
HPE Compute Ops Manager connection status is changed to Connected.
Cleared By
Health Category
None
Severity
OK
Resolution
None.
iLOEvents.ComputeOpsManagerConnectionInterrupted
Description
Connection to HPE Compute Ops Manager is interrupted.
Cleared By
Health Category
None
Severity
Warning
Resolution
Please check the DNS and proxy server settings. Reset the management processor for re-initiating the connection immediately. Refer User Guide for more information.
iLOEvents.BundleUpdateFailed
Description
Bundle update failed.
Cleared By
Health Category
None
Severity
Warning
Resolution
Verify the contents of the install set file and retry the Bundle Update.
HPE Compute Ops Manager activation is not complete.
Cleared By
Health Category
None
Severity
Warning
Resolution
Visit cloud.hpe.com and confirm that the serial number and productID of this Management Processor has been added correctly to the device inventory and retry this operation OR Check the proxy settings. Contact support if the problem persists.
iLOEvents.SSLCertEnrollSuccess
Description
SSL certificate enrollment succeeded.
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.SSLCertRenewalSuccess
Description
SSL certificate renewal succeeded.
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.CertEnrollmentServerConnectionFailed
Description
Connection to the Certificate enrollment server failed.
Cleared By
Health Category
Severity
Warning
Resolution
Check the server URL, CA certificate imported and DNS settings are correct. Re-enable (disable and enable) the certificate enrollment service to trigger the process again. Contact support if the problem persists.
iLOEvents.CertEnrollmentCACertValidationFailed
Description
Validation of CA certificate failed.
Cleared By
Health Category
Severity
Warning
Resolution
Check the server URL, CA certificate imported and DNS settings are correct. Re-enable (disable and enable) the certificate enrollment service to trigger the process again. Contact support if the problem persists.
iLOEvents.CertEnrollmentConfigSettingChanged
Description
Certificate enrollment configuration setting is changed.
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.CertEnrollmentServiceState
Description
Certificate enrollment service state changed.
Cleared By
Health Category
Severity
OK
Resolution
None.
iLOEvents.IssuingSSLCertFailed
Description
Certificate enrollment Server denied to issue the certificate.
Cleared By
Health Category
Severity
Warning
Resolution
1. Check if challenge password is correct. 2. Check server logs for more information on the error. Re-enable (disable and enable) the certificate enrollment service to trigger the process again. Contact support if the problem persists.
iLOEvents.SSLCertValFailed
Description
Validation of issued SSL certificate failed.
Cleared By
Health Category
Severity
Warning
Resolution
Check the server CA settings to ensure signing hash algorithms are compliant with the configured iLO security state. Re-enable (disable and enable) the certificate enrollment service to trigger the process again. Contact support if the problem persists.
iLOEvents.CSRGenerationFailed
Description
Failed to generate CSR.
Cleared By
Health Category
Severity
Warning
Resolution
Check the CSR subject values are correct. Re-enable (disable and enable) the certificate enrollment service to trigger the process again. Contact support if the problem persists.