Event definitions of iLO v1.10

Need a simple description here that could come from an eventshdr.md file.

Refer to the Redfish event service section for more information.

iLOEvents.PMMSecureEraseFailed

Description Secure Erase of Intel Optane PMem for HPE Module has failed.
Cleared By
Health Category Memory
Severity Critical
Resolution Retry Secure Erase. Please contact support if issue persists.

iLOEvents.AdapterConfigurationChange

Description The specified adapter has had a configuration change.
Cleared By
Health Category ServerBlade
Severity OK
Resolution None

iLOEvents.AutoShutdownCancelled

Description Management processor cancelled previously initiated automatic operating system shutdown.
Cleared By
Health Category Thermal
Severity OK
Resolution Check shutdown cause and the Integrated Management Log (IML) for additional information.

iLOEvents.AutoShutdownInitiated

Description Management processor initiated an automatic operating system shutdown.
Cleared By ServerPostDiscoveryComplete
Health Category None
Severity Critical
Resolution Check shutdown cause and the Integrated Management Log (IML) for additional information.

iLOEvents.BatteryBackupUnitError

Description Battery Backup Unit Error.
Cleared By BatteryBackupUnitErrorRepaired
Health Category Power
Severity Warning
Resolution Check error condition and the Integrated Management Log (IML) for additional information.

iLOEvents.BatteryBackupUnitErrorRepaired

Description Battery Backup Unit Error Repaired.
Cleared By
Health Category Power
Severity OK
Resolution None

iLOEvents.CorrectableOrUncorrectableMemoryErrors

Description Correctable or uncorrectable Memory Errors Detected. Correctable errors have been corrected, but the memory module should be replaced.
Cleared By
Health Category Memory
Severity Warning
Resolution Replace the failing memory module.

iLOEvents.DeviceDiscoveryStatusV2

Description The server device discovery status has changed.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.DrvArrAcceleratorFlashMemoryNotAttached

Description Flash memory component of the flash backed cache module is not attached.
Cleared By
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DrvArrControllerFailed

Description The drive array controller has failed.
Cleared By DrvArrControllerOK
Health Category Storage
Severity Critical
Resolution Reboot the server or replace the controller.

iLOEvents.DrvArrControllerOK

Description The drive array controller is operating properly.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DrvArrLogDrvBadConnect

Description A physical drive is not responding.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Critical
Resolution Replace the physical drive.

iLOEvents.DrvArrLogDrvErasing

Description The logical drive is currently being erased.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DrvArrLogDrvExpanding

Description The logical drive is currently undergoing a transformation.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DrvArrLogDrvFailed

Description The drive array logical drive has failed.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Critical
Resolution Data loss has occurred. Replace the failed physical drive(s).

iLOEvents.DrvArrLogDrvMultiPathAccessDegraded

Description All disk drives of this logical drive had more than one I/O path to the controller, but now one or more of them have only one I/O path.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DrvArrLogDrvNewLogDrvKeyRekeyRequestReceived

Description The logical drive is currently encrypted and has received a request to rekey all data with a new logical drive encryption key.The logical drive is online.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DrvArrLogDrvNoAccessEncryptedMissingKey

Description The logical drive is currently encrypted and cannot be accessed because the array controller has not yet received the encryption key from Management Processor.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Critical
Resolution Consult the HPE Secure Encryption Installation and User Guide for troubleshooting.

iLOEvents.DrvArrLogDrvNoAccessEncryptedWithControllerEncryptionNotEnabled

Description The logical drive is currently encrypted and cannot be accessed because the array controller does not have encryption enabled.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Critical
Resolution Consult the HPE Secure Encryption Installation and User Guide for troubleshooting.

iLOEvents.DrvArrLogDrvNotAvailable

Description The logical drive is currently unavailable.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DrvArrLogDrvOK

Description The logical drive is in normal operation mode.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DrvArrLogDrvOverheating

Description The drive array enclosure that contains the logical drive is overheating.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Warning
Resolution The drive array is still functioning, but should be shutdown.

iLOEvents.DrvArrLogDrvPredictiveSpareRebuildReady

Description The logical drive is ready to perform a predictive spare rebuild.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DrvArrLogDrvQueuedForExpansion

Description The logical drive is ready for transformation.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DrvArrLogDrvRapidParityInitializationInProgress

Description The logical drive is currently undergoing rapid parity initialization.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DrvArrLogDrvRapidParityInitializationPending

Description The logical drive is currently pending rapid parity initialization and will be unavailable.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DrvArrLogDrvReadyRebuild

Description The drive array logical drive is ready for Automatic Data Recovery.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Warning
Resolution The failed physical drive has been replaced, but the logical drive is still operating in Interim Recovery Mode.

iLOEvents.DrvArrLogDrvRebuilding

Description The drive array logical drive is currently doing Automatic Data Recovery.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DrvArrLogDrvRecovering

Description The drive array logical drive is using Interim Recovery Mode.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Warning
Resolution At least one physical drive has failed, but no data has been lost.

iLOEvents.DrvArrLogDrvRekeyInProgress

Description The logical drive is currently encrypted and all data is currently being rekeyed with a new logical drive key using the background capacity expansion transformation task.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DrvArrLogDrvShutdown

Description The drive array enclosure that contains the logical drive has overheated.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Critical
Resolution Ensure that the array enclosure is being cooled properly.

iLOEvents.DrvArrLogDrvUnconfigured

Description The drive array logical drive is not configured.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Critical
Resolution Run HPE array configuration utility

iLOEvents.DrvArrLogDrvUnencryptedToEncryptedTransformationInProgress

Description The logical drive is currently being transformed from unencrypted to encrypted and the volume is online.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DrvArrLogDrvUnencryptedToEncryptedTransformationNotStarted

Description The logical drive has received a request to transform from unencrypted to encrypted but this process has not yet started.The unencrypted logical drive is currently online.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DrvArrLogDrvWrongDrive

Description The wrong physical drive was replaced after a physical drive failure.
Cleared By DrvArrLogDrvOK
Health Category Storage
Severity Critical
Resolution Replace the physical drive.

iLOEvents.DrvArrPhysDrvEraseDone

Description The drive array physical drive has been erased and is is now in an offline state.
Cleared By
Health Category Storage
Severity Warning
Resolution None

iLOEvents.DrvArrPhysDrvEraseQueued

Description An erase operation is currently queued for the drive array physical drive.
Cleared By DrvArrPhysDrvEraseDone
Health Category Storage
Severity Warning
Resolution None

iLOEvents.DrvArrPhysDrvErasing

Description The drive array physical drive is being erased.
Cleared By DrvArrPhysDrvEraseDone
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DrvArrPhysDrvFailed

Description The drive array physical drive has failed.
Cleared By DrvArrPhysDrvOK
Health Category Storage
Severity Critical
Resolution Replace the drive.

iLOEvents.DrvArrPhysDrvNotAuthenticated

Description The drive array physical drive could not be authenticated as a genuine HPE hard drive.
Cleared By DrvArrPhysDrvOK
Health Category Storage
Severity Warning
Resolution Replace the drive with a genuine HPE hard drive.

iLOEvents.DrvArrPhysDrvOK

Description The drive array physical drive is functioning properly.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DrvArrPhysDrvPredictiveFailure

Description The drive array physical drive has a predictive failure error.
Cleared By DrvArrPhysDrvOK
Health Category Storage
Severity Warning
Resolution Replace the drive.

iLOEvents.DrvArrPhysDrvWearOut

Description The drive array physical drive is approaching the maximum usage limit for writes.
Cleared By DrvArrPhysDrvOK
Health Category Storage
Severity Warning
Resolution Replace the drive as soon as possible.

iLOEvents.DrvArrSolidStateDiskFiftySixDayThresholdPassed

Description The solid state disk will reach the maximum usage limit for writes (wear out) within fifty-six days.
Cleared By DrvArrSolidStateDiskWearOK
Health Category Storage
Severity Warning
Resolution Modify your write workload or plan to replace your SSD drive.

iLOEvents.DrvArrSolidStateDiskFivePercentThresholdPassed

Description The solid state disk has passed the five percent threshold and is at or below five percent of reaching the maximum usage limit for writes (wear out).
Cleared By DrvArrSolidStateDiskWearOK
Health Category Storage
Severity Warning
Resolution Plan to replace your SSD drive.

iLOEvents.DrvArrSolidStateDiskTwoPercentThresholdPassed

Description The solid state disk has passed the two percent threshold and is at or below five percent of reaching the maximum usage limit for writes (wear out).
Cleared By DrvArrSolidStateDiskWearOK
Health Category Storage
Severity Warning
Resolution Plan to replace your SSD drive.

iLOEvents.DrvArrSolidStateDiskWearOK

Description The solid state disk is not in any imminent danger of wear out.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DrvArrSolidStateDiskWearOut

Description The solid state disk is approaching the maximum usage limit for writes (wear out).
Cleared By DrvArrSolidStateDiskWearOK
Health Category Storage
Severity Critical
Resolution Replace the drive.

iLOEvents.DrvArrSpareDriveActive

Description Automatic Data Recovery is complete.
Cleared By
Health Category Storage
Severity OK
Resolution None

iLOEvents.DrvArrSpareDriveBuilding

Description A physical drive has failed. Automatic Data Recovery is in progress to recover data to the on-line spare.
Cleared By DrvArrSpareDriveActive
Health Category Storage
Severity Critical
Resolution None.

iLOEvents.DrvArrSpareDriveFailed

Description The on-line spare has failed and is no longer available for use.
Cleared By
Health Category Storage
Severity Critical
Resolution Replace the drive.

iLOEvents.DrvArrSpareDriveInactive

Description An on-line spare is configured, but is not currently in use.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DrvArrayAccBoardBadData

Description The cache module board has lost backup power. If data was being stored in the cache module memory when the server lost power, that data has been lost.
Cleared By
Health Category Storage
Severity Critical
Resolution Verify that no data has been lost. Investigate the cause of the failure and take corrective action.

iLOEvents.DrvArrayAccBoardBatteryFailed

Description The cache module board backup power source has failed.
Cleared By
Health Category Storage
Severity Critical
Resolution Replace the backup power source.

iLOEvents.DrvArrayAccBoardEnabled

Description Cache operations are currently configured and enabled for at least one logical drive.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DrvArrayAccBoardInvalid

Description Cache module board is not installed in this system or is present but not configured.
Cleared By
Health Category Storage
Severity Warning
Resolution Install and/or configure the cache module board.

iLOEvents.DrvArrayAccBoardPermDisabled_BackupPowerSourceHotRemoved

Description Write cache operations have been permanently disabled because a backup power source has been hot removed.
Cleared By
Health Category Storage
Severity Critical
Resolution Consult the HPE Array Configuration Utility User Guide for troubleshooting.

iLOEvents.DrvArrayAccBoardPermDisabled_BadMirrorData

Description Write cache operations have been permanently disabled because the mirrored copies of data do not match.
Cleared By
Health Category Storage
Severity Warning
Resolution Data may have been lost, and you should service the board.

iLOEvents.DrvArrayAccBoardPermDisabled_BatteryNotSupported

Description Write cache operations have been permanently disabled because one or more attached batteries are not supported by the currently running firmware.
Cleared By
Health Category Storage
Severity Critical
Resolution Update the firmware.

iLOEvents.DrvArrayAccBoardPermDisabled_CapacitorChargeLow

Description Write cache operations have been temporarily disabled due to insufficient capacitor power.
Cleared By DrvArrayAccBoardEnabled
Health Category Storage
Severity Critical
Resolution None.

iLOEvents.DrvArrayAccBoardPermDisabled_CapacitorFailedToCharge

Description Write cache operations have been permanently disabled because the flash backed cache module capacitor has failed to charge.
Cleared By
Health Category Storage
Severity Critical
Resolution Replace the board.

iLOEvents.DrvArrayAccBoardPermDisabled_ChargerCircuitFailure

Description Write cache operations have been permanently disabled because the charger circuit on the flash backed cache module has failed.
Cleared By
Health Category Storage
Severity Critical
Resolution Replace the board.

iLOEvents.DrvArrayAccBoardPermDisabled_ConfigCommand

Description Write cache operations have been permanently disabled because the configuration of the logical drives has changed.
Cleared By
Health Category Storage
Severity Warning
Resolution Reconfigure the cache module board.

iLOEvents.DrvArrayAccBoardPermDisabled_ExcessiveECCErrors

Description Write cache operations have been permanently disabled because the number of cache lines experiencing excessive ECC errors has reached the preset limit.
Cleared By
Health Category Storage
Severity Critical
Resolution Replace the cache module board.

iLOEvents.DrvArrayAccBoardPermDisabled_FlashBackedBackupFailed

Description Write cache operations have been permanently disabled because because the flash backed cache module backup operation has failed.
Cleared By
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DrvArrayAccBoardPermDisabled_FlashBackedHardwareFailure

Description Write cache operations have been permanently disabled because the flash backed cache module has encountered a hardware failure.
Cleared By
Health Category Storage
Severity Critical
Resolution Replace the board.

iLOEvents.DrvArrayAccBoardPermDisabled_FlashBackedRestoreFailed

Description Write cache operations have been permanently disabled because because the flash backed cache module restore operation has failed.
Cleared By
Health Category Storage
Severity Critical
Resolution Service the board.

iLOEvents.DrvArrayAccBoardPermDisabled_IncompatibleCacheModule

Description Write cache operations have been permanently disabled because an incompatible cache module is being used.
Cleared By
Health Category Storage
Severity Critical
Resolution Replace the board.

iLOEvents.DrvArrayAccBoardPermDisabled_NoCapacitorAttached

Description Write cache operations have been permanently disabled because there are no capacitors attached to the flash backed cache module.
Cleared By
Health Category Storage
Severity Critical
Resolution Check the status of the flash backed cache module.

iLOEvents.DrvArrayAccBoardPermDisabled_NotEnoughBatteries

Description Write cache operations have been permanently disabled because there are not enough batteries attached to the controller.
Cleared By
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DrvArrayAccBoardPermDisabled_NotSupportedByFirmware

Description Write cache operations have been permanently disabled because the current cache module is not supported by the currently running firmware.
Cleared By
Health Category Storage
Severity Warning
Resolution Update the firmware.

iLOEvents.DrvArrayAccBoardPermDisabled_PostECCErrors

Description Write cache operations have been permanently disabled due to a large number of ECC errors detected while testing the cache during POST.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DrvArrayAccBoardPermDisabled_ReadFailure

Description Write cache operations have been permanently disabled because memory parity errors have occurred.
Cleared By
Health Category Storage
Severity Warning
Resolution Data has been lost, and you should service the board.

iLOEvents.DrvArrayAccBoardPermDisabled_WriteFailure

Description Write cache operations have been permanently disabled because data could not be written to write cache memory in duplicate due to the detection of parity errors.
Cleared By
Health Category Storage
Severity Warning
Resolution You should service the chache module board.

iLOEvents.DrvArrayAccBoardTempDisabled_BadConfiguration

Description Write cache operations have been temporarily disabled due to bad configuration.
Cleared By DrvArrayAccBoardEnabled
Health Category Storage
Severity Critical
Resolution Rerun the configuration utility and ensure that the board has been properly configured for this system.

iLOEvents.DrvArrayAccBoardTempDisabled_BoardNotConnected

Description Write cache operations have been temporarily disabled because the cache module board has been configured but is not currently attached to the controller.
Cleared By DrvArrayAccBoardEnabled
Health Category Storage
Severity Critical
Resolution Check the alignment of the board and connections.

iLOEvents.DrvArrayAccBoardTempDisabled_DisableCommandIssued

Description Write cache operations have been temporarily disabled by the driver.
Cleared By DrvArrayAccBoardEnabled
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DrvArrayAccBoardTempDisabled_ExpandInProgress

Description Write cache operations have been temporarily disabled due to an expand of a logical drive.
Cleared By DrvArrayAccBoardEnabled
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DrvArrayAccBoardTempDisabled_LowBatteryPower

Description Write cache operations have been temporarily disabled while the energy pack is charging.
Cleared By DrvArrayAccBoardEnabled
Health Category Storage
Severity Critical
Resolution No action needed. Write cache operations will be automatically enabled after the energy pack charges.

iLOEvents.DrvArrayAccBoardTempDisabled_MegaCellNotCabled

Description Write cache operations have been permanently disabled because the megacell is not cabled.
Cleared By
Health Category Storage
Severity Critical
Resolution None. (999)

iLOEvents.DrvArrayAccBoardTempDisabled_NoResourcesAvailable

Description Write cache operations have been temporarily disabled because the controller does not have sufficient resources to perform write cache operations.
Cleared By DrvArrayAccBoardEnabled
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DrvArrayAccBoardTempDisabledRAIDADG_EnablerModuleMissing

Description Write cache operations have been temporarily disabled because the RAID ADG Enabler Module is broken or missing.
Cleared By DrvArrayAccBoardEnabled
Health Category Storage
Severity Critical
Resolution Replace or install the ADG Enabler Module.

iLOEvents.DrvArrayAccBoardTempDisabled_RedundantCacheFailure

Description Write cache operations have been temporarily disabled because the cache on the redundant controller has failed.
Cleared By DrvArrayAccBoardEnabled
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DrvArrayAccBoardTempDisabled_RedundantLowBattery

Description Write cache operations have been temporarily disabled because redundant controller has insufficient cache battery power.
Cleared By DrvArrayAccBoardEnabled
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DrvArrayAccBoardTempDisabled_RedundantSizeMismatch

Description Write cache operations have been temporarily disabled because the cache sizes on the redundant controllers do not match.
Cleared By DrvArrayAccBoardEnabled
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DrvArrayAccBoardTempDisabled_SnapshotInProgress

Description Write cache operations have been temporarily disabled due to a snapshot operation that is queued up or in progress.
Cleared By DrvArrayAccBoardEnabled
Health Category Storage
Severity OK
Resolution None.

iLOEvents.EmbeddedMediaSecureEraseFailed

Description Secure Erase of the management processor's embedded media device has failed.
Cleared By
Health Category None
Severity Critical
Resolution Retry Secure Erase. Please contact HPE support if issue persists.

iLOEvents.FanDegraded

Description The specified fault tolerant fan is now in a degraded state.
Cleared By
Health Category Fan
Severity Critical
Resolution Replace the failing fan.

iLOEvents.FanFailed

Description The specified fault tolerant fan has failed.
Cleared By
Health Category Fan
Severity Critical
Resolution Replace the failed fan.

iLOEvents.FanInserted

Description A fault tolerant fan has been inserted into the specified fan location.
Cleared By
Health Category Fan
Severity OK
Resolution None.

iLOEvents.FanRedundancyLost

Description The fault tolerant fans have lost redundancy.
Cleared By FanRedundancyRestored
Health Category Fan
Severity Warning
Resolution Check the system fans for a failure.

iLOEvents.FanRedundancyRestored

Description The fault tolerant fans have returned to a redundant state.
Cleared By
Health Category Fan
Severity OK
Resolution None.

iLOEvents.FanRemoved

Description A fault tolerant fan has been removed from the specified fan location.
Cleared By FanInserted
Health Category Fan
Severity Warning
Resolution None.

iLOEvents.FirmwareFlashStatusChanged

Description The firmware flash status has changed
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.FirmwareIntegrityScanComplete

Description This event is generated when a firmware integrity issue is found during firmware scan irrespective of a recovery success or failure.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.IntelligentDiagnosticsEnabled

Description Intelligent Diagnostics Enabled: Server will attempt automated recovery.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.IntelligentDiagnosticsExit

Description Intelligent Diagnostics Exit: Automated server recovery has concluded.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.BIOSSafeModeEngaged

Description BIOS Safe Mode is engaged. System will boot in a minimal configuration.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.BIOSSafeModeExit

Description BIOS Safe Mode has successfully booted. System will resume boot in a minimal configuration.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.FirmwareRecoveryRequest

Description This event is generated when firmware recovery is requested.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.FirmwareValidationAutoRepairFailed

Description Integrated Lights-Out failed to automatically repair the integrity scan issue.
Cleared By
Health Category None
Severity Warning
Resolution The indicated firmware must be manually updated. The server should not be rebooted until this has been addressed.

iLOEvents.FirmwareValidationScanErrorRepaired

Description Firmware integrity scan or boot time validation issue reported has been repaired.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.FirmwareValidationScanFailed

Description The firmware integrity scan or boot time validation detected an anomaly that requires the firmware to be updated.
Cleared By FirmwareValidationScanErrorRepaired
Health Category None
Severity Critical
Resolution If configured for auto-recovery, the repair attempt will happen automatically. If not configured or if it does not succeed, then manual recovery is needed. If the anomaly was detected as part of OS boot time validation, then a manual recovery is needed.

iLOEvents.HeNvdimmControllerFirmwareError

Description NVDIMM Error - Controller Firmware Error. The controller firmware has been corrupted. The OS will not use the NVDIMM.
Cleared By
Health Category Memory
Severity Critical
Resolution Re-program the firmware to restore NVDIMM functionality.

iLOEvents.HeNvdimmLifecycleWarning

Description NVDIMM Lifecycle Warning. NVDIMM lifetime has reached.
Cleared By
Health Category Memory
Severity Warning
Resolution Backup NVDIMM contents to other media to preserve data and replace NVDIMM.

iLOEvents.HeNvdimmSanitizationOk

Description NVDIMM Sanitization Ok. This NVDIMM-N was selected for Sanitizing/Erasing. All data saved in the NVDIMM has been erased.
Cleared By
Health Category Memory
Severity Warning
Resolution Re-program the firmware to restore NVDIMM functionality.

iLOEvents.HoodRemoved

Description System hood is removed or not in a properly installed state. This situation may result in improper cooling of the system due to air flow changes caused by the missing hood.
Cleared By HoodReplaced
Health Category None
Severity Warning
Resolution Ensure that the server chassis hood was intentionally removed and the server is secure. Replace the cover, ensuring it is properly installed. Verify the system is in working order.

iLOEvents.HoodRemovedOnPowerOff

Description BIOS detected a system hood removal when server power was off.
Cleared By HoodReplaced
Health Category None
Severity Warning
Resolution Ensure that the server chassis hood was intentionally removed and that the server is secure.

iLOEvents.HoodReplaced

Description System hood has been replaced.
Cleared By
Health Category None
Severity OK
Resolution Ensure that the server chassis hood was intentionally replaced, and the server is secure.

iLOEvents.ILOToInsightRemoteSupportCommunicationFailure

Description Management Processor to Insight Remote Support or Insight Online communication failed.
Cleared By
Health Category Remotesupport
Severity Warning
Resolution Please check the connectivity to Insight Remote Support or Insight Online Host.

iLOEvents.IPMIWatchdogTimerReset

Description The Management processor detected a watchdog timer timeout. The failsafe timer was not periodically addressed after it was armed in the operating system.
Cleared By
Health Category None
Severity Warning
Resolution Review management processor event logs and any relevant operating system history for additional information.

iLOEvents.IdeAtaSecureEraseFailed

Description Secure Erase of SATA drive has failed.
Cleared By
Health Category Storage
Severity Critical
Resolution Please refer the IML Troubleshooting guide or click on Learn More link for additional information and any necessary action to be taken.

iLOEvents.IndicatorLEDStateChanged

Description The state of the indicator LED has changed
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.InterlockFailureErrorPowerOn

Description The server had a power fault that occurred while attempting to power on.
Cleared By
Health Category Power
Severity Critical
Resolution Refer to the Integrated Management Log for details. Remove and then reinstall the failed device. Attempt to boot the server.

iLOEvents.InterlockFailureErrorRuntime

Description The server was shut down due to a power fault that occurred while it was powered on.
Cleared By
Health Category Power
Severity Critical
Resolution Refer to the Integrated Management Log for details. Remove and then reinstall the failed device. Attempt to boot the server.

iLOEvents.InterlockFailureErrorStandby

Description The server had a power fault that occurred while it was powered off.
Cleared By
Health Category Power
Severity Critical
Resolution Refer to the Integrated Management Log for details. Remove and then reinstall the failed device. Attempt to boot the server.

iLOEvents.InterlockFailureErrorUnknown

Description The server had a power fault but the reason is unknown.
Cleared By
Health Category Power
Severity Critical
Resolution Refer to the Integrated Management Log for details. Remove and then reinstall the failed device. Attempt to boot the server.

iLOEvents.IntrusionHWInstalled

Description System intrusion alert hardware is installed.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.IntrusionHWRemoved

Description System intrusion alert hardware is removed.
Cleared By
Health Category None
Severity OK
Resolution There is no action required if the removal of the hardware is expected. If the hardware was not intentionally removed, please verify cable connection.

iLOEvents.MetricValueBelowLowerThreshold

Description Metric value is below user defined lower threshold.
Cleared By
Health Category None
Severity Warning
Resolution Please check the current configured server workload.

iLOEvents.MetricValueExceededUpperThreshold

Description Metric value exceeded user defined upper threshold.
Cleared By
Health Category None
Severity Warning
Resolution Please check the current configured server workload.

iLOEvents.MirroredMemoryEngaged

Description Advanced Memory Protection Mirrored Memory Engaged. The Advanced Memory Protection subsystem has detected a memory fault. Mirrored Memory has been activated.
Cleared By
Health Category Memory
Severity Warning
Resolution Replace the faulty memory.

iLOEvents.AlternateGPUManagementInterfaceActive

Description Management Processor has detected a change in the management interface usage for health monitoring
Cleared By
Health Category None
Severity OK
Resolution Schedule a server maintenance reboot. Also, collect and submit this server's AHS log to customer support.

iLOEvents.NoGPUManagementInterfaceActive

Description Management Processor has detected a change in the management interface usage for health monitoring
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.PrimaryGPUManagementInterfaceActive

Description Management Processor has detected a change in the management interface usage for health monitoring
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.NVMeSecureEraseFailed

Description Secure Erase of NVMe drive has failed.
Cleared By
Health Category Storage
Severity Critical
Resolution Please refer the IML Troubleshooting guide or click on Learn More link for additional information and any necessary action to be taken.

iLOEvents.NicAllLinksDown

Description The physical adapter has had a function up at any point and transitions to having all of its functions down.
Cleared By NicAllLinksDownRepaired
Health Category Network
Severity Critical
Resolution Check the connection to the adapter and validate the connectivity from the server to any external device, including the cabling. If no problems are found, the adapter or other connectivity device may need replacement.

iLOEvents.NicAllLinksDownRepaired

Description The physical adapter has had a function up at any point and transitions to having all of its functions down and then has one if its functions return to up.
Cleared By
Health Category Network
Severity OK
Resolution None.

iLOEvents.NicConnectivityLost

Description The physical adapter in a single adapter configuration failed or at least one physical adapter in a logical adapter group failed.
Cleared By NicConnectivityRestored
Health Category Network
Severity Warning
Resolution Check the connection to the adapter and validate the connectivity from the server to any external device, including the cabling. If no problems are found, the adapter or other connectivity device may need replacement.

iLOEvents.NicConnectivityRestored

Description The physical adapter in a single adapter configuration returns to the OK condition or at least one physical adapter in a logical adapter group returns to the OK condition.
Cleared By
Health Category Network
Severity OK
Resolution None.

iLOEvents.NoPowerSupplyDetected

Description Power Supply or Power Backplane Detection Error.
Cleared By ServerPostDiscoveryComplete
Health Category Power
Severity Critical
Resolution Ensure that system CPLD and, if applicable, chassis firmware is up to date.

iLOEvents.NvdimmArmingError

Description NVDIMM Error - Arming Error. NVDIMM could not be armed and future backups are not possible.
Cleared By
Health Category Memory
Severity Critical
Resolution Save NVDIMM contents to other media to preserve data and then replace the NVDIMM.

iLOEvents.NvdimmBackupError

Description NVDIMM Error - Backup Error detected. Persistent data backup failed and data is not available.
Cleared By
Health Category Memory
Severity Critical
Resolution Save NVDIMM contents to other media to preserve data and then replace the NVDIMM.

iLOEvents.NvdimmBackupPowerError

Description NVDIMM Error - Backup Power Error. Backup power is not available and a future backup is not possible.
Cleared By
Health Category Memory
Severity Critical
Resolution Ensure backup power is available. Backup NVDIMM contents to other media to preserve data.

iLOEvents.NvdimmBatteryNotChargedwithNoWait

Description Smart battery is not charged sufficiently to support the NVDIMMs installed in the system.
Cleared By
Health Category Memory
Severity Warning
Resolution None.

iLOEvents.NvdimmBatteryNotChargedwithWait

Description Smart battery is not charged sufficiently to support the NVDIMMs installed in the system.
Cleared By
Health Category Memory
Severity Warning
Resolution None.

iLOEvents.NvdimmConfigurationError

Description One or more NVDIMM Configuration errors occurred. Details of the NVDIMM Configuration error messages can be found in Integrated Management Log
Cleared By
Health Category Memory
Severity Critical
Resolution Refer to the Integrated Management Log for details on NVDIMM Configuration error.

iLOEvents.NvdimmControllerError

Description NVDIMM Error - NVDIMM Controller Error. An error was found with the NVDIMM controller. The OS will not use the NVDIMM.
Cleared By
Health Category Memory
Severity Critical
Resolution Update the NVDIMM FW. If issue persists, replace the NVDIMM.

iLOEvents.NvdimmEraseError

Description NVDIMM Error - Erase Error. NVDIMM could not be erased and future backups are not possible.
Cleared By
Health Category Memory
Severity Critical
Resolution Save NVDIMM contents to other media to preserve data and then replace the NVDIMM.

iLOEvents.NvdimmEventNotifyError

Description NVDIMM Error - Unable to set event notification for this NVDIMM.
Cleared By
Health Category Memory
Severity Critical
Resolution Update the NVDIMM FW. If issue persists, replace the NVDIMM.

iLOEvents.NvdimmInitializationError

Description Persistent Memory Address Range Scrub has detected an error.
Cleared By
Health Category Memory
Severity Warning
Resolution Update System ROM and Innovation Engine firmware to latest supported revision. Contact support if issue persists.

iLOEvents.NvdimmInterleaveOff

Description NVDIMM Error - Controller Interleave Off. Received a memory initialization or uncorrectable error. All NVDIMMs on Processor are disabled.
Cleared By
Health Category Memory
Severity Critical
Resolution Sanitize all NVDIMMs on the processor. If problem persists, replace the NVDIMM.

iLOEvents.NvdimmInterleaveOn

Description NVDIMM Error - Controller Interleave On. Received a memory initialization or uncorrectable error. All NVDIMMs on Processor are disabled.
Cleared By
Health Category Memory
Severity Critical
Resolution Sanitize all NVDIMMs on the processor. If problem persists, replace the NVDIMM.

iLOEvents.NvdimmLogicalNvdimmError

Description One or more Logical NVDIMM errors occurred. Details of the Logical NVDIMM error messages can be found in Integrated Management Log
Cleared By
Health Category Memory
Severity Warning
Resolution Refer to the Integrated Management Log for details on Logical NVDIMM Errors.

iLOEvents.NvdimmMemoryMapChanged

Description Uncorrectable Memory Error. The failed memory module could not be determined.
Cleared By
Health Category Memory
Severity Warning
Resolution Refer to the Integrated Management Log for details on NVDIMM error.

iLOEvents.NvdimmPersistantMemoryAddressError

Description Persistent Memory Address Range Scrub has detected an error.
Cleared By
Health Category Memory
Severity Critical
Resolution If the Operating System is unable to recover, check the Integrated Management Log (IML) for additional information.

iLOEvents.NvdimmPersistencyLost

Description NVDIMM Error - Persistency Lost. NVDIMM Persistency is lost and future data backup is not available.
Cleared By NvdimmPersistencyRestored
Health Category Memory
Severity Critical
Resolution Backup the data and replace the NVDIMM.

iLOEvents.NvdimmPersistencyRestored

Description NVDIMM - Persistency Restored. NVDIMM Persistency is restored and future data backup is available.
Cleared By
Health Category Memory
Severity OK
Resolution None.

iLOEvents.NvdimmRestoreError

Description NVDIMM Error - Restore Error detected. Persistent data restore failed and data is not available.
Cleared By
Health Category Memory
Severity Critical
Resolution Replace NVDIMM if issue persists.

iLOEvents.NvdimmSanitizationError

Description NVDIMM Error - Sanitization Error. This NVDIMM-N was selected for Sanitizing/Erasing, but this process was not successful.
Cleared By HeNvdimmSanitizationOk
Health Category Memory
Severity Critical
Resolution Save NVDIMM contents to other media to preserve data and then replace the NVDIMM.

iLOEvents.NvdimmUncorrectableMemoryError

Description NVDIMM Error - Uncorrectable Memory Error detected. This NVDIMM will not be available to the operating system.
Cleared By
Health Category Memory
Severity Critical
Resolution Replace the NVDIMM.

iLOEvents.OSSecurityScan

Description HPE Trusted OS Security found an OS Kernel Corruption.
Cleared By
Health Category
Severity Critical
Resolution Shutdown server and determine the cause of the corruption.

iLOEvents.OSSecurityAdd

Description HPE Trusted OS Security found a new module was added.
Cleared By
Health Category
Severity Critical
Resolution Verify module was a valid new module.

iLOEvents.OSSecurityRemove

Description HPE Trusted OS Security found an OS Kernel module was removed.
Cleared By
Health Category
Severity Critical
Resolution Verify module removal was valid.

iLOEvents.OSSecurityHeartbeat

Description HPE Trusted OS Security heartbeat timeout.
Cleared By
Health Category
Severity Critical
Resolution Verify security scanning software is installed and operating properly. Possible intrusion disabled scanning software.

iLOEvents.OSSecurityPIDCOW

Description HPE Trusted OS Security found a copy on write issue with process.
Cleared By
Health Category
Severity Critical
Resolution Verify process change was approved.

iLOEvents.OSSecurityPIDHeartbeat

Description HPE Trusted OS Security found a heartbeat issue with process.
Cleared By
Health Category
Severity Critical
Resolution Verify process is running and approved version.

iLOEvents.OSSecurityPIDMemfd

Description HPE Trusted OS Security found a memfd library issue with process.
Cleared By
Health Category
Severity Critical
Resolution Verify process is running and approved version.

iLOEvents.OSSecurityPIDPath

Description HPE Trusted OS Security found a lib path issue with process.
Cleared By
Health Category
Severity Critical
Resolution Verify process is running and approved version.

iLOEvents.OSSecurityPIDInject

Description HPE Trusted OS Security found a library injection issue with process.
Cleared By
Health Category
Severity Critical
Resolution Verify process is running and approved version.

iLOEvents.OSSecurityPIDDel

Description HPE Trusted OS Security found a library deleted or renamed in process.
Cleared By
Health Category
Severity Critical
Resolution Verify process is running and approved version.

iLOEvents.OSSecurityPIDEnvar

Description HPE Trusted OS Security found a possible malicious enviroment variable in process.
Cleared By
Health Category
Severity Critical
Resolution Verify environment variables have not been compromised.

iLOEvents.OSSecurityPIDMisc

Description HPE Trusted OS Security found a miscellaneous issue in process.
Cleared By
Health Category
Severity Critical
Resolution Verify system has not been compromised.

iLOEvents.OSSecurityCfgChange

Description HPE Trusted OS Security configuration change.
Cleared By
Health Category
Severity Critical
Resolution Verify configuration change to software verification settings is valid.

iLOEvents.OSSecurityUnexpectedChange

Description HPE Trusted OS Security detected an unexpected configuration change in OS Kernel.
Cleared By
Health Category
Severity Critical
Resolution Verify changes made to kernel modules or kernel settings are valid.

iLOEvents.OSSecurityKernelModuleCorrection

Description HPE Trusted OS Security detected an unexpected correction in OS Kernel Module
Cleared By
Health Category
Severity Critical
Resolution Verify that the correction for Kernel Module is intentional and done by authorized administrator on Host OS.

iLOEvents.OSSecurityUpdateTimeout

Description HPE Trusted OS Security update timeout.
Cleared By
Health Category
Severity Critical
Resolution Reload host driver to reinitialize scan tables.

iLOEvents.OverallSecStateAtRisk

Description The overall security state of the system is at risk.
Cleared By
Health Category None
Severity Warning
Resolution Refer to iLO User Manual or iLO Security Dashboard help page.

iLOEvents.OverallSecStatusChange

Description Overall security status changed.
Cleared By
Health Category None
Severity Warning
Resolution Refer to iLO User Manual or iLO Security Dashboard help page.

iLOEvents.PCIeDiskTemperatureFailed

Description The temperature of the disk has crossed the upper critical threshold.
Cleared By PCIeDiskTemperatureOk
Health Category Storage
Severity Critical
Resolution Check the system for hardware failures and verify the environment is properly cooled.

iLOEvents.PCIeDiskTemperatureOk

Description The PCIe Disk`s temperature has returned to the normal operating range.
Cleared By
Health Category Storage
Severity OK
Resolution None

iLOEvents.PCIeDriveAddedOrPowerOn

Description A PCI device has been added to the system or powered on.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.PCIeDriveConditionDegraded

Description PCIe disk status is degraded.
Cleared By PCIeDriveConditionOk
Health Category Storage
Severity Warning
Resolution Plan to replace the drive.

iLOEvents.PCIeDriveConditionFailed

Description PCIe disk status is failed.
Cleared By PCIeDriveConditionOk
Health Category Storage
Severity Critical
Resolution Replace the drive.

iLOEvents.PCIeDriveConditionOk

Description PCIe disk status is ok.
Cleared By
Health Category Storage
Severity OK
Resolution None

iLOEvents.PCIeDriveRemovedOrPowerOff

Description A PCI device has been removed from the system or powered off.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.PCIeDriveWearStatusFiftySixDayThreshold

Description PCIe disk wear status threshold is FiftySixDayThreshold.
Cleared By PCIeDriveWearStatusOk
Health Category Storage
Severity Warning
Resolution Plan to replace the disk.

iLOEvents.PCIeDriveWearStatusFivePercentThreshold

Description PCIe disk wear status threshold is FivePercentThreshold.
Cleared By PCIeDriveWearStatusOk
Health Category Storage
Severity Warning
Resolution Plan to replace the disk.

iLOEvents.PCIeDriveWearStatusOk

Description PCIe disk wear status is ok.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.PCIeDriveWearStatusTwoPercentThreshold

Description PCIe disk wear status threshold is TwoPercentThreshold.
Cleared By PCIeDriveWearStatusOk
Health Category Storage
Severity Warning
Resolution Plan to replace the disk.

iLOEvents.PCIeDriveWearStatusWearOut

Description PCIe disk wear status threshold is wear out.
Cleared By PCIeDriveWearStatusOk
Health Category Storage
Severity Critical
Resolution Replace the disk the status indicate wear out.

iLOEvents.POSTErrorsOccurred

Description One or more POST errors occurred. Power On Self-Test (POST) errors occur during the server restart process. Details of the POST error messages can be found in Integrated Management Log
Cleared By
Health Category Logs
Severity Warning
Resolution Refer to the Integrated Management Log for details on the Power on self-test error.

iLOEvents.PciResetFail

Description System is unable to perform a reset on the PCI controller in slot.
Cleared By ServerPostDiscoveryComplete
Health Category Storage
Severity Critical
Resolution Update pci Configuration controller firmware and retry the secure erase operation. If the issue persists, contact HPE support.

iLOEvents.PowerDegradedEventDetected

Description A degraded power event has been detected and the server system board should be replaced.
Cleared By ServerPostDiscoveryComplete
Health Category Power
Severity Critical
Resolution Power down and remove the server from power to have the server system board replaced.

iLOEvents.PowerFailureCpuThermalTrip

Description The server was shut down because the CPU temperature sensor was above the allowed threshold.
Cleared By ServerPostDiscoveryComplete
Health Category Power
Severity Critical
Resolution Refer to the Integrated Management Log for details. Try the following steps until the error no longer occurs: a) Remove the AC power, and then restore AC power. Attempt to boot the server. (b) Remove and then reinstall the failed device. Attempt to boot the server. (c) Swap the failed device with a known good device and attempt to boot the server.

iLOEvents.PowerFailureErrorBadFuse

Description The server was shut down because one or more fuses tripped.
Cleared By ServerPostDiscoveryComplete
Health Category Power
Severity Critical
Resolution Refer to the Integrated Management Log for details. Try the following steps until the error no longer occurs: a) Remove the AC power, and then restore AC power. Attempt to boot the server. (b) Remove and then reinstall the failed device. Attempt to boot the server. (c) Swap the failed device with a known good device and attempt to boot the server.

iLOEvents.PowerFailureErrorInputPowerLoss

Description The server was shut down because the input power source was removed.
Cleared By ServerPostDiscoveryComplete
Health Category Power
Severity Critical
Resolution Refer to the Integrated Management Log for details. Try the following steps until the error no longer occurs: a) Remove the AC power, and then restore AC power. Attempt to boot the server. (b) Remove and then reinstall the failed device. Attempt to boot the server. (c) Swap the failed device with a known good device and attempt to boot the server.

iLOEvents.PowerFailureErrorTempAboveCritical

Description The server was shut down because a temperature sensor was above the critical threshold.
Cleared By ServerPostDiscoveryComplete
Health Category Power
Severity Critical
Resolution Refer to the Integrated Management Log for details. Try the following steps until the error no longer occurs: a) Remove the AC power, and then restore AC power. Attempt to boot the server. (b) Remove and then reinstall the failed device. Attempt to boot the server. (c) Swap the failed device with a known good device and attempt to boot the server.

iLOEvents.PowerFailurePowerOn

Description The server had a power fault while attempting to power on.
Cleared By ServerPostDiscoveryComplete
Health Category Power
Severity Critical
Resolution Refer to the Integrated Management Log for details. Try the following steps until the error no longer occurs: a) Remove the AC power, and then restore AC power. Attempt to boot the server. (b) Remove and then reinstall the failed device. Attempt to boot the server. (c) Swap the failed device with a known good device and attempt to boot the server.

iLOEvents.PowerFailureRuntime

Description The server was shut down due to a power fault that occurred while it was powered on.
Cleared By ServerPostDiscoveryComplete
Health Category Power
Severity Critical
Resolution Refer to the Integrated Management Log for details. Try the following steps until the error no longer occurs: a) Remove the AC power, and then restore AC power. Attempt to boot the server. (b) Remove and then reinstall the failed device. Attempt to boot the server. (c) Swap the failed device with a known good device and attempt to boot the server.

iLOEvents.PowerFailureStandby

Description The server had a power fault that occurred while it was powered off.
Cleared By ServerPostDiscoveryComplete
Health Category Power
Severity Critical
Resolution Refer to the Integrated Management Log for details. Try the following steps until the error no longer occurs: a) Remove the AC power, and then restore AC power. Attempt to boot the server. (b) Remove and then reinstall the failed device. Attempt to boot the server. (c) Swap the failed device with a known good device and attempt to boot the server.

iLOEvents.PowerFailureUnknown

Description The server had a power fault but the reason is unknown.
Cleared By ServerPostDiscoveryComplete
Health Category Power
Severity Critical
Resolution Refer to the Integrated Management Log for details. Try the following steps until the error no longer occurs: a) Remove the AC power, and then restore AC power. Attempt to boot the server. (b) Remove and then reinstall the failed device. Attempt to boot the server. (c) Swap the failed device with a known good device and attempt to boot the server.

iLOEvents.PowerProtectionFault

Description System Board Power Protection Fault.
Cleared By
Health Category None
Severity Critical
Resolution Check the Integrated Management Log (IML) for additional information.

iLOEvents.PowerRedundancyLost

Description The fault tolerant power supplies have lost redundancy.
Cleared By PowerRedundancyRestored
Health Category Power
Severity Warning
Resolution Check the system power supplies for a failure.

iLOEvents.PowerRedundancyRestored

Description The fault tolerant power supplies have returned to a redundant state.
Cleared By
Health Category Power
Severity OK
Resolution None.

iLOEvents.PowerSupplyACPowerLoss

Description Power supply AC power loss for the specified power bay location.
Cleared By PowerSupplyOK
Health Category Power
Severity Critical
Resolution Check the power source for the specified power supply.

iLOEvents.PowerSupplyDegraded

Description The fault tolerant power supply in the specified bay location is degraded.
Cleared By PowerSupplyOK
Health Category Power
Severity Critical
Resolution Replace the failing power supply.

iLOEvents.PowerSupplyFailed

Description The fault tolerant power supply in the specified bay location has failed.
Cleared By PowerSupplyOK
Health Category Power
Severity Critical
Resolution Replace the failed power supply.

iLOEvents.PowerSupplyInserted

Description A fault tolerant power supply has been inserted into the specified bay location.
Cleared By
Health Category Power
Severity OK
Resolution None.

iLOEvents.PowerSupplyOK

Description The fault tolerant power supply in the specified bay location is orperating normally.
Cleared By
Health Category Power
Severity OK
Resolution None.

iLOEvents.PowerSupplyRemoved

Description A fault tolerant power supply has been removed from the specified bay location.
Cleared By PowerSupplyInserted
Health Category Power
Severity Warning
Resolution None.

iLOEvents.PowerThresholdBreach

Description Power threshold exceeded.
Cleared By
Health Category Power
Severity Warning
Resolution Check the power threshold settings.

iLOEvents.ProcessorStatusDegraded

Description Processor status changed. Processor can be brought down to Stop state and removed from O.S Active set
Cleared By
Health Category Processor
Severity Warning
Resolution Update the system firmware. If the issue persists, check the Integrated Management Log (IML) for recommended action.

iLOEvents.ProcessorStatusDisabled

Description Processor status changed. Processor brought down to Stop state and removed from O.S Active set
Cleared By
Health Category Processor
Severity Warning
Resolution Update the system firmware. If the issue persists, check the Integrated Management Log (IML) for recommended action.

iLOEvents.ProcessorStatusFailed

Description Processor status changed. Processor brought down to Stop state and removed from O.S Active set
Cleared By
Health Category Processor
Severity Critical
Resolution Update the system firmware. If the issue persists, check the Integrated Management Log (IML) for recommended action.

iLOEvents.ProcessorStatusOK

Description Processor status changed. Processor brought back to Running state and made member of O.S Active set
Cleared By
Health Category Processor
Severity OK
Resolution None.

iLOEvents.ProcessorStatusUnknown

Description Processor status changed. Processor can be brought down to Stop state and removed from O.S Active set or Brought back to Running state and made member of O.S Active set
Cleared By
Health Category Processor
Severity Warning
Resolution Update the system firmware. If the issue persists, check the Integrated Management Log (IML) for recommended action.

iLOEvents.PwrSupplyError

Description System Power Supply Error.
Cleared By PwrSupplyErrorRepaired
Health Category Power
Severity Warning
Resolution Check error condition and the Integrated Management Log (IML) for additional information.

iLOEvents.PwrSupplyErrorRepaired

Description System Power Supply Error Repaired.
Cleared By
Health Category Power
Severity OK
Resolution None

iLOEvents.ResourceAdded

Description Resource added.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.ResourceRemoved

Description Resource removed.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.ResourceStatusChanged

Description Resource status changed.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.ResourceUpdated

Description Resource updated.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.SEDPassPhraseFailed

Description Device Encryption Error. Enabling or Disabling encryption/modifying pass phrase failed.
Cleared By
Health Category None
Severity Critical
Resolution Retry with correct pass phrase. If issue persists contact HPE support.

iLOEvents.SEDUnlockFailed

Description Three wrong attempts were made to unlock Self Encrypting Device. The device will be locked until the next reboot.
Cleared By
Health Category None
Severity Warning
Resolution Reboot server and retry.

iLOEvents.SNMPAuthenticationFailure

Description An unauthorized user attempted to access the Management Processor via SNMP
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.SPISecureEraseFailed

Description Secure Erase of System Firmware Configuration has failed.
Cleared By
Health Category None
Severity Critical
Resolution Retry Secure Erase. Please contact HPE Support if issue persists.

iLOEvents.SecureBootAuthCertFail

Description Secure Boot Authentication Failure - The image was not authorized due to revoked certificate(s) and was not executed.
Cleared By
Health Category None
Severity Warning
Resolution Update the image to a new version where the certificate used to sign the image and the image hash are not in the Secure Boot forbidden database (DBX).

iLOEvents.PMMHealthFailure

Description An Intel Optane PMem for HPE Module has experienced an issue and is no longer operational/resilient.
Cleared By
Health Category Memory
Severity Critical
Resolution Backup Intel Optane PMem for HPE contents to other media to preserve data and replace the PMem.

iLOEvents.PMMLessUsageRemainingAlert

Description An Intel Optane PMem for HPE Module Percentage Remaining Alert. The Intel Optane PMem for HPE Module has less usage remaining. Future errors on this Persistent Memory Module may result in loss of data.
Cleared By
Health Category Memory
Severity Critical
Resolution Backup Persistent Memory Module contents to other media to preserve data immediately and replace the PMem.

iLOEvents.PMMConfigError

Description One or more PMem Configuration errors occurred.
Cleared By
Health Category Memory
Severity Critical
Resolution Review documentation for more information on supported configurations.

iLOEvents.PMMShutdownWarning

Description Intel Optane PMem for HPE Module Health Warning. Intel Optane PMem for HPE Module reported an unsafe shutdown.
Cleared By
Health Category Memory
Severity Critical
Resolution Check Integrated Management Log (IML) for additional information. If the issue persists, check if the system firmware is latest, including the system programmable logic device and system ROM. Check power supply and replace if needed.

iLOEvents.SecureBootAuthFail

Description Secure Boot Authentication Failure - The image failed authentication and was not executed.
Cleared By
Health Category None
Severity Warning
Resolution Update the image to known good trusted version. If current image is trusted, then update the Secure Boot allowed database (DB) with the certificate or image hash.

iLOEvents.SecurityOverrideDisengaged

Description Security override disengaged. Management Processor firmware has detected the security override jumper has been toggled to the disengaged position.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.SecurityOverrideEngaged

Description Security override engaged. Management Processor firmware has detected the security override jumper has been toggled to the engaged position.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.ServerHardwareSignatureChanged

Description The server hardware signature has changed. This can be caused by addition or removal of Mezziane cards or relocation of the server.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.ServerOperational

Description The server is operational again. The server has previously been shutdown due to a thermal anomaly on the server and has just become operational again.
Cleared By
Health Category Thermal
Severity Warning
Resolution None.

iLOEvents.ServerPostComplete

Description The server has reached Power On Self Test complete.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.ServerPostDiscoveryComplete

Description The server has completed device discovery.
Cleared By
Health Category Security
Severity OK
Resolution None.

iLOEvents.ServerPowerOnFailure

Description A request was made to power on the server, however the server could not be powered on due to a failure condition.
Cleared By ServerPostDiscoveryComplete
Health Category Power
Severity Critical
Resolution Refer to the Integrated Management Log for details on why the server could not be powered on.

iLOEvents.ServerPoweredOff

Description The server has been powered off.
Cleared By
Health Category Power
Severity OK
Resolution None.

iLOEvents.ServerPoweredOn

Description The server has been powered on.
Cleared By
Health Category Power
Severity OK
Resolution None.

iLOEvents.ServerResetDetected

Description Server Reset Detected. Management Processor firmware has detected a server reset.
Cleared By
Health Category DeviceBay
Severity Warning
Resolution Refer to the Integrated Management Log for details on the cause of the server reset.

iLOEvents.SmartArraySecureEraseFailed

Description Secure Erase of Smart Array has failed.
Cleared By
Health Category Storage
Severity Critical
Resolution Retry Secure Erase. Please contact HPE Support if issue persists.

iLOEvents.RefreshSystemInventory

Description Refresh system Software and Firmware Inventory.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.StorageSystemFanDegraded

Description At least one storage system fan has failed, but there is still sufficient cooling capacity to allow the system to continue.
Cleared By StorageSystemFanOK
Health Category Fan
Severity Critical
Resolution Replace the failing fan(s).

iLOEvents.StorageSystemFanFailed

Description One or more storage system fans have failed.
Cleared By StorageSystemFanOK
Health Category Fan
Severity Critical
Resolution Replace the failing fan(s) immediately to avoid hardware damage.

iLOEvents.StorageSystemFanOK

Description All storage system fan are working normally.
Cleared By
Health Category Fan
Severity OK
Resolution None.

iLOEvents.StorageSystemNoFan

Description This unit does not support fan monitoring.
Cleared By StorageSystemFanOK
Health Category Fan
Severity Warning
Resolution None.

iLOEvents.StorageSystemNoPwrSupply

Description The storage system does not support fault tolerant power supply monitoring.
Cleared By StorageSystemPwrSupplyOK
Health Category Power
Severity Warning
Resolution None.

iLOEvents.StorageSystemNoTemperature

Description The storage system does not support temperature monitoring.
Cleared By StorageSystemTemperatureOK
Health Category Thermal
Severity Warning
Resolution None.

iLOEvents.StorageSystemPwrSupplyDegraded

Description One of the power supply units in the fault tolerant power supply in the storage system has failed.
Cleared By StorageSystemPwrSupplyOK
Health Category Power
Severity Critical
Resolution Restore power or replace the failed power supply.

iLOEvents.StorageSystemPwrSupplyOK

Description The power supplies in the storage system are working normally.
Cleared By
Health Category Power
Severity OK
Resolution None.

iLOEvents.StorageSystemTemperatureDegraded

Description The storage system temperature is outside of normal operating range.
Cleared By StorageSystemTemperatureOK
Health Category Thermal
Severity Critical
Resolution Shutdown the storage system as soon as possible. Ensure that the storage system environment is being cooled properly and that no components are overheated.

iLOEvents.StorageSystemTemperatureFailed

Description The storage system temperature could permanently damage the system.The storage system will automatically shutdown.
Cleared By StorageSystemTemperatureOK
Health Category Thermal
Severity Critical
Resolution Shutdown the storage system as soon as possible. Ensure that the storage system environment is being cooled properly and that no components are overheated.

iLOEvents.StorageSystemTemperatureOK

Description The storage system temperature is within normal operating range.
Cleared By
Health Category Thermal
Severity OK
Resolution None.

iLOEvents.StorageSystemNotConnected

Description The storage system is not connected to the controller.
Cleared By StorageSystemConnected
Health Category Storage
Severity Critical
Resolution Please restore the connectivity of storage system to the adapter.

iLOEvents.StorageSystemNotSupported

Description This unit does not support connected controller.
Cleared By StorageSystemConnected
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.StorageSystemConnected

Description The storage system connection to controller is working normally.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.SystemBatteryFailed

Description The system energy pack has either failed or met a pre-failure warning condition for the specified location.
Cleared By
Health Category Battery
Severity Warning
Resolution Replace the failed energy pack.

iLOEvents.SystemBatteryRemoved

Description The system energy pack has been removed in the specified location.
Cleared By
Health Category Battery
Severity Warning
Resolution Refer to the Smart Storage energy pack issues section in Troubleshooting Guide for HPE ProLiant servers for further troubleshooting.

iLOEvents.SystemPowerAllocationNotOptimized

Description Error in setting server power throttle. Server enclosure power request has increased. Server power allocation is not optimized.
Cleared By
Health Category Power
Severity Critical
Resolution Refer to the Integrated Management Log on the Management Processor for details. Power down & reinsert the server blade.

iLOEvents.SystemPowerOnDenied

Description One of the Field Replacement Units(FRU) is not allowing the system to power on.
Cleared By ServerPostDiscoveryComplete
Health Category Power
Severity Critical
Resolution Refer to the Integrated Management Log on the Management Processor for details. Power down & reinsert the server blade.

iLOEvents.TPMSecureEraseFailed

Description Trusted Platform Module has failed the Secure Erase Operation.
Cleared By
Health Category Storage
Severity Critical
Resolution Update Trusted Platform Module firmware and retry the secure erase operation. If the issue persists, contact HPE support.

iLOEvents.TestAlert

Description This is a test alert.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.ThermalStatusDegradedSysContinue

Description The server's temperature is outside of the normal operating range in the specified location. The server will continue operation.
Cleared By ThermalStatusOK
Health Category Thermal
Severity Critical
Resolution Check the system for hardware failures and verify the environment is properly cooled.

iLOEvents.ThermalStatusDegradedSysShutdown

Description The server's temperature is outside of the normal operating range in the specified location. The server will be shutdown.
Cleared By ServerOperational
Health Category Thermal
Severity Critical
Resolution Check the system for hardware failures and verify the environment is properly cooled.

iLOEvents.ThermalStatusFailure

Description The temperature status has been set to failed in the specified chassis and location.
Cleared By ThermalStatusOK
Health Category Thermal
Severity Critical
Resolution Check the system for hardware failures and verify the environment is properly cooled.

iLOEvents.ThermalStatusOK

Description The server's temperature has returned to the normal operating range in the specified location.
Cleared By
Health Category Thermal
Severity OK
Resolution None.

iLOEvents.USBStorageDeviceReadError

Description A read error occurred on the USB storage device attached to the system.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.USBStorageDeviceRedundancyLost

Description Redundancy is lost on the USB storage device attached to the system.
Cleared By USBStorageDeviceRedundancyRestored
Health Category Storage
Severity Warning
Resolution Replace the failed USB Storage Device.

iLOEvents.USBStorageDeviceRedundancyRestored

Description Redundancy is restored on a USB storage device attached to the system.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.USBStorageDeviceSyncFailed

Description Sync operation to restore redundancy failed on a USB storage device attached to the system.
Cleared By
Health Category Storage
Severity Warning
Resolution Replace the failed USB Storage Device.

iLOEvents.USBStorageDeviceWriteError

Description A write error occurred on the USB storage device attached to the system.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.UnauthorizedLoginAttempts

Description Management Processor firmware has detected multiple unauthorized login attempts.
Cleared By
Health Category None
Severity OK
Resolution Check the Management Processor event log for more information on the login failure.

iLOEvents.UpdateTaskStateChanged

Description An update task has changed state.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.SeCpuUncorrectableError

Description Uncorrectable processor error was detected.
Cleared By ServerPostDiscoveryComplete
Health Category Processor
Severity Critical
Resolution Re-seat the processor and update to the latest firmware. If the issue persists contact support.

iLOEvents.iLODriveComponentAdded

Description A component was added to the iLO Drive.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.SecurityStateChange

Description Security state changed.
Cleared By
Health Category None
Severity OK
Resolution No Action

iLOEvents.iLOReset

Description Management Processor reset pending
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.iLORestServicesStarted

Description RESTful services started.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.RemoteSupportUnregistrationComplete

Description The server was unregistered from Remote Support.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.RemoteSupportRegistrationComplete

Description The server was registered to Remote Support.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.EnclosureManagerFirmwareMismatch

Description The Enclosure Manager firmware version is below the minimum supported version.
Cleared By
Health Category None
Severity Critical
Resolution Update the firmware.

iLOEvents.InletAmbientPreCautionThresAlert

Description Inlet Ambient temperature sensor user defined Pre-Caution threshold level exceeded.
Cleared By
Health Category
Severity Warning
Resolution None.

iLOEvents.LiquidCoolingModuleFailed

Description The specified Liquid Cooling module has failed.
Cleared By
Health Category Thermal
Severity Critical
Resolution Check Server documentation to be sure the liquid cooling module configuration meets the functional requirements of the server and replace the Module accordingly.

iLOEvents.LiquidCoolingModuleDegraded

Description The specified Liquid cooling Module is now in a degraded state.
Cleared By
Health Category Thermal
Severity Critical
Resolution Check Server documentation to be sure the liquid cooling module configuration meets the functional requirements of the server and replace the Module accordingly.

iLOEvents.LiquidCoolingModuleRedundancyLost

Description The Liquid Cooling Module has lost redundancy.
Cleared By LiquidCoolingModuleRedundancyRestored
Health Category Thermal
Severity Warning
Resolution Add or Replace the Liquid Cooling Module.

iLOEvents.LiquidCoolingModuleRedundancyRestored

Description The liquid cooling modules have returned to a redundant state.
Cleared By
Health Category Thermal
Severity OK
Resolution None.

iLOEvents.DriveSmartError2

Description The ATA drive has a error predictive failure error.
Cleared By DriveOk2
Health Category Storage
Severity Critical
Resolution Replace the drive.

iLOEvents.DriveFailed2

Description The ATA drive has failed.
Cleared By DriveOk2
Health Category Storage
Severity Critical
Resolution Replace the drive.

iLOEvents.DriveOk2

Description The ATA drive is functioning properly.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DriveWearOut2

Description The ATA drive is approaching the maximum usage limit for writes.
Cleared By DriveOk2
Health Category Storage
Severity Warning
Resolution Replace the drive as soon as possible.

iLOEvents.DriveRemoved2

Description The ATA drive has been removed from the specified location.
Cleared By DriveOk2
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DriveInserted2

Description The ATA drive has been inserted into the specified location.
Cleared By
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DriveWearStatusWearOut2

Description The ATA drive wear status threshold is wear out.
Cleared By DriveWearStatusOk2
Health Category Storage
Severity Critical
Resolution Replace the drive the status indicate wear out.

iLOEvents.DriveWearStatusFiftySixDayThreshold2

Description The ATA drive wear status threshold is FiftySixDayThreshold.
Cleared By DriveWearStatusOk2
Health Category Storage
Severity Warning
Resolution Plan to replace the drive.

iLOEvents.DriveWearStatusFivePercentThreshold2

Description The ATA drive wear status threshold is FivePercentThreshold.
Cleared By DriveWearStatusOk2
Health Category Storage
Severity Warning
Resolution Plan to replace the drive.

iLOEvents.DriveWearStatusTwoPercentThreshold2

Description The ATA drive wear status threshold is TwoPercentThreshold.
Cleared By DriveWearStatusOk2
Health Category Storage
Severity Warning
Resolution Plan to replace the drive.

iLOEvents.DriveWearStatusOk2

Description The ATA Drive wear status is ok.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DriveSmartError

Description The ATA drive has a error predictive failure error.
Cleared By DriveOk
Health Category Storage
Severity Critical
Resolution Replace the drive.

iLOEvents.DriveFailed

Description The ATA drive has failed.
Cleared By DriveOk
Health Category Storage
Severity Critical
Resolution Replace the drive.

iLOEvents.DriveOk

Description The ATA drive is functioning properly.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.DriveWearOut

Description The ATA drive is approaching the maximum usage limit for writes.
Cleared By DriveOk
Health Category Storage
Severity Warning
Resolution Replace the drive as soon as possible.

iLOEvents.DriveRemoved

Description The ATA drive has been removed from the specified location.
Cleared By
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DriveInserted

Description The ATA drive has been inserted into the specified location.
Cleared By
Health Category Storage
Severity Warning
Resolution None.

iLOEvents.DriveWearStatusWearOut

Description The ATA drive wear status threshold is wear out.
Cleared By DriveWearStatusOk
Health Category Storage
Severity Critical
Resolution Replace the drive the status indicate wear out.

iLOEvents.DriveWearStatusFiftySixDayThreshold

Description The ATA drive wear status threshold is FiftySixDayThreshold.
Cleared By DriveWearStatusOk
Health Category Storage
Severity Warning
Resolution Plan to replace the drive.

iLOEvents.DriveWearStatusFivePercentThreshold

Description The ATA drive wear status threshold is FivePercentThreshold.
Cleared By DriveWearStatusOk
Health Category Storage
Severity Warning
Resolution Plan to replace the drive.

iLOEvents.DriveWearStatusTwoPercentThreshold

Description The ATA drive wear status threshold is TwoPercentThreshold.
Cleared By DriveWearStatusOk
Health Category Storage
Severity Warning
Resolution Plan to replace the drive.

iLOEvents.DriveWearStatusOk

Description The ATA Drive wear status is ok.
Cleared By
Health Category Storage
Severity OK
Resolution None.

iLOEvents.UnsupportedPowerSupplyUnitDetected

Description Power supply installed is not supported by the processor.
Cleared By UnsupportedPowerSupplyUnitRemoved
Health Category Power
Severity Critical
Resolution Replace the unsupported Power Supply.

iLOEvents.UnsupportedPowerSupplyUnitRemoved

Description Unsupported Power supply unit is removed.
Cleared By
Health Category Power
Severity OK
Resolution None.

iLOEvents.UserDefThresholdWarningAlert

Description User defined caution temperature threshold has been exceeded.
Cleared By
Health Category
Severity Warning
Resolution None.

iLOEvents.UserDefThresholdCriticalAlert

Description User defined critical temperature threshold has been exceeded.
Cleared By
Health Category
Severity Critical
Resolution None.

iLOEvents.ComputeOpsManagerConnectionInitiated

Description Connection to HPE Compute Ops Manager has been initiated.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.ComputeOpsManagerDisabledByUser

Description User has disabled connection to HPE Compute Ops Manager.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.ComputeOpsManagerDisabledBySecureErase

Description Connection to HPE Compute Ops Manager has been disabled due to secure erase.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.ComputeOpsManagerDisabledByFactoryDefaults

Description Connection to HPE Compute Ops Manager has been disabled due to Factory defaults.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.ComputeOpsManagerConnectionSuccessful

Description Connection to HPE Compute Ops Manager is successful.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.ComputeOpsManagerConnectionNotEnabled

Description HPE Compute Ops Manager connection status is changed to Not Enabled.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.ComputeOpsManagerConnectionInProgress

Description HPE Compute Ops Manager connection status is changed to In Progress.
Cleared By ComputeOpsManagerConnected
Health Category None
Severity OK
Resolution None.

iLOEvents.ComputeOpsManagerConnectionFailed

Description HPE Compute Ops Manager connection status is changed to Failed.
Cleared By ComputeOpsManagerConnected
Health Category None
Severity Warning
Resolution None.

iLOEvents.ComputeOpsManagerConnected

Description HPE Compute Ops Manager connection status is changed to Connected.
Cleared By
Health Category None
Severity OK
Resolution None.

iLOEvents.ComputeOpsManagerConnectionInterrupted

Description Connection to HPE Compute Ops Manager is interrupted.
Cleared By
Health Category None
Severity Warning
Resolution Please check the DNS and proxy server settings. Reset the management processor for re-initiating the connection immediately. Refer User Guide for more information.

iLOEvents.BundleUpdateFailed

Description Bundle update failed.
Cleared By
Health Category None
Severity Warning
Resolution Verify the contents of the install set file and retry the Bundle Update.

iLOEvents.ComputeOpsManagerActivationFailedCertError

Description HPE Compute Ops Manager activation is incomplete.
Cleared By
Health Category None
Severity Warning
Resolution Please check the Management Processor's date/time and proxy settings. Contact support if the problem persists.

iLOEvents.ComputeOpsManagerActivationFailedRDAConnectionError

Description HPE Compute Ops Manager activation is not complete due to RDA connectivity issue.
Cleared By
Health Category None
Severity Warning
Resolution Please check the DNS and proxy configuration settings. Contact support if the problem persists.

iLOEvents.ComputeOpsManagerActivationFailedCCSConnectionError

Description HPE Compute Ops Manager activation is not complete due to CCS connectivity issue.
Cleared By
Health Category None
Severity Warning
Resolution Please check the DNS and proxy configuration settings. Contact support if the problem persists.

iLOEvents.ComputeOpsManagerActivationFailedCCSErrors

Description HPE Compute Ops Manager activation is not complete.
Cleared By
Health Category None
Severity Warning
Resolution Visit cloud.hpe.com and confirm that the serial number and productID of this Management Processor has been added correctly to the device inventory and retry this operation OR Check the proxy settings. Contact support if the problem persists.

iLOEvents.SSLCertEnrollSuccess

Description SSL certificate enrollment succeeded.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.SSLCertRenewalSuccess

Description SSL certificate renewal succeeded.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.CertEnrollmentServerConnectionFailed

Description Connection to the Certificate enrollment server failed.
Cleared By
Health Category
Severity Warning
Resolution Check the server URL, CA certificate imported and DNS settings are correct. Re-enable (disable and enable) the certificate enrollment service to trigger the process again. Contact support if the problem persists.

iLOEvents.CertEnrollmentCACertValidationFailed

Description Validation of CA certificate failed.
Cleared By
Health Category
Severity Warning
Resolution Check the server URL, CA certificate imported and DNS settings are correct. Re-enable (disable and enable) the certificate enrollment service to trigger the process again. Contact support if the problem persists.

iLOEvents.CertEnrollmentConfigSettingChanged

Description Certificate enrollment configuration setting is changed.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.CertEnrollmentServiceState

Description Certificate enrollment service state changed.
Cleared By
Health Category
Severity OK
Resolution None.

iLOEvents.IssuingSSLCertFailed

Description Certificate enrollment Server denied to issue the certificate.
Cleared By
Health Category
Severity Warning
Resolution 1. Check if challenge password is correct. 2. Check server logs for more information on the error. Re-enable (disable and enable) the certificate enrollment service to trigger the process again. Contact support if the problem persists.

iLOEvents.SSLCertValFailed

Description Validation of issued SSL certificate failed.
Cleared By
Health Category
Severity Warning
Resolution Check the server CA settings to ensure signing hash algorithms are compliant with the configured iLO security state. Re-enable (disable and enable) the certificate enrollment service to trigger the process again. Contact support if the problem persists.

iLOEvents.CSRGenerationFailed

Description Failed to generate CSR.
Cleared By
Health Category
Severity Warning
Resolution Check the CSR subject values are correct. Re-enable (disable and enable) the certificate enrollment service to trigger the process again. Contact support if the problem persists.

iLOEvents.ServerFirmwareInventoryComplete

Description The server firmware inventory has been completed.
Cleared By
Health Category
Severity OK
Resolution None.